Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Residential Building Energy Use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Addressing the split incentive challenge for rooftop solar PV and battery energy storage in multifamily rental buildings (CRADA 638 Final Report)

This project advances the understanding of how roof solar PV systems and battery energy storage systems (BESS) can be effectively deployed in multifamily residential buildings, a sector that has historically faced barriers due to misaligned incentives between landlords and tenants. By leveraging high-resolution building stock data and simulation tools, the research demonstrates how energy consumption patterns vary across building types, climates, and occupant characteristics, and how these variations influence the optimal sizing and operation of distributed energy resources. A key contribution is the development of a publicly accessible, web-based tool named RESIDE (Residential Energy Systems & Infrastructure Data Evaluation) that allows users to explore building energy use and evaluate solar and battery configurations without requiring specialized expertise. This significantly lowers the barrier to entry for stakeholders such as property owners, utilities, and policymakers. From a technical perspective, the project shows that integrating rooftop solar PV with battery energy storage can substantially reduce electricity costs and peak demand through strategies such as energy arbitrage and peak shaving. The modeling framework incorporates real-world constraints, including time-of-use electricity pricing and battery degradation, providing realistic and actionable insights. Economically, the results indicate that properly sized systems can deliver meaningful cost savings, improving the feasibility of energy investments in multifamily housing. More broadly, the project benefits the public by supporting the transition to affordable and reliable energy, particularly in rental multifamily housing where adoption has traditionally lagged.

14 SOLAR ENERGY↗

An Assessment of Actual and Potential Building Climate Zone Change and Variability From the Last 30 Years Through 2100 Using NASA's MERRA and CMIP5 Simulations

Background: In the US, residential and commercial building infrastructure combined consumes about 40% of total energy usage and emits about 39% of total CO2 emission (DOE/EIA "Annual Energy Outlook 2013"). Building codes, as used by local and state enforcement entities are typically tied to the dominant climate within an enforcement jurisdiction classified according to various climate zones. These climate zones are based upon a 30-year average of local surface observations and are developed by DOE and ASHRAE. Establishing the current variability and potential changes to future building climate zones is very important for increasing the energy efficiency of buildings and reducing energy costs and emissions in the future. Objectives: This paper demonstrates the usefulness of using NASA's Modern Era Retrospective-analysis for Research and Applications (MERRA) atmospheric data assimilation to derive the DOE/ASHRAE building climate zone maps and then using MERRA to define the last 30 years of variability in climate zones for the Continental US. An atmospheric assimilation is a global atmospheric model optimized to satellite, atmospheric and surface in situ measurements. Using MERRA as a baseline, we then evaluate the latest Climate Model Inter-comparison Project (CMIP) climate model Version 5 runs to assess potential variability in future climate zones under various assumptions. Methods: We derive DOE/ASHRAE building climate zones using surface and temperature data products from MERRA. We assess these zones using the uncertainties derived by comparison to surface measurements. Using statistical tests, we evaluate variability of the climate zones in time and assess areas in the continental US for statistically significant trends by region. CMIP 5 produced a data base of over two dozen detailed climate model runs under various greenhouse gas forcing assumptions. We evaluate the variation in building climate zones for 3 different decades using an ensemble and quartile statistics to provide an assessment of potential building climate zone changes relative to the uncertainties demonstrated using MERRA. Findings and Conclusions: These results show that there is a statistically significant increase in the area covered by warmer climate zones and a tendency for a reduction of area in colder climate zones in some limited regions. The CMIP analysis shows that models vary from relatively little building climate zone change for the least sensitive and conservation assumptions to a warming of at most 3 zones for certain areas, particularly the north central US by the end of the 21st century.

Stackhouse, Paul W., Jr.↗

End Use Load Profile (EULP) of US Building Sector resulting from mass GHP retrofits

This collection of datasets describes the change (difference) in hourly energy consumption of the U.S. residential and commercial building stock while replacing existing HVAC systems with ground source heat pumps for all the balancing areas in the US, for all buildings eligible for ground source heat pump replacement. Additional county-level data may be requested from the DOE Project Lead.

15 GEOTHERMAL ENERGY↗

Potential Heating Energy and Cost Savings of Dual Fuel Heat Pump Controls as a Residential Building Equipment Retrofit in the U.S.

This study investigated the energy and cost savings potential by modeling a dual fuel heat pump system with its control for a residential building in (5A) cold climate in U.S. The simulation analysis showed that the application of the DFHP system and its control to the target building can save the heating energy by 42% over a gas furnace system (baseline system). Although the HP-only system can save more heating energy (i.e., 53%) over the baseline system than DFHP system does, the DFHP with its control demonstrated the higher cost savings when a time of use electricity rate was considered.

Yoon, Yeobeom↗

ResStock Dataset 2024.1 Documentation

Public ResStock datasets provide credible, relevant, and accessible information on energy use and related non-energy metrics to a variety of stakeholders in the residential buildings space. The current public datasets include baseline building characteristics, timeseries (15-minute) energy consumption, and timeseries carbon emissions for the baseline (existing) U.S. housing stock and the U.S. housing stock with 10 "what-if" energy measure packages applied. This report documents a new public ResStock dataset to complement and build upon the existing public datasets. This dataset is specifically intended to be a resource for state and local decision-makers considering options for energy retrofits for their housing stock to reduce carbon emissions, energy use, and/or utility bills. These data consist of housing stock characteristics and modeled full-year energy consumption, carbon emission, energy bill, and energy burden data for the baseline U.S. housing stock as well as the U.S. housing stock with 260 "what-if" energy measure packages applied. These measure packages include measures related to the building envelope, appliances, pools and spas, lighting, water heating, and HVAC (including efficiency improvements and fuel switching with equipment at a range of performance levels) in a variety of combinations. This report provides methodology information on the generation of this dataset and serves as a key part of the dataset's public documentation.

buildings↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock (TM) is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Variable-Speed Geothermal Heat Pump (GHP). This document provides the relevant new modeling information for variable-speed systems not previously covered in either the single-stage or two-stage documents. Variable-speed GHPs represent the most efficient option available for this technology: They provide the most savings, with up to 46% for the applicable portion of the housing stock, compared to 31% for less efficient single-stage GHPs. Additional results shown here detail how the savings change for sections of the housing stock with different base heating fuels and in different climate zones, and they show the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

Design Heating and Cooling Load Calculation Versus Building Load Simulation for Cold Climate Heat Pumps: Understanding the "Gap"

This report explores the differences between Manual J-equivalent block load calculations and building HVAC energy simulation results using EnergyPlus™ calculations when designing cold climate heat pump systems for residential use. This study will help HVAC researchers and advanced designers understand the impacts of oversizing heat pumps on home energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hierarchical Model-Free Transactive Control of Building Loads to Support Grid Services

Residential buildings consume 4.4 quads of electricity annually, approximately 37% of the total electricity consumption in the United States. This represents a vast resource that can be used for demand management and other ancillary services. This project aims to develop a robust, scalable hierarchical transactional control mechanism incorporating elements of model-free control (MFC) and game theory to harness buildings to provide ancillary services to the grid. This approach is being taken to address the challenges of incorporating traditional transactional control schemes into existing buildings. The challenges include small individual building sizes requiring aggregation of many buildings, unpredictable energy usage that makes model identification difficult, and satisfying the sensitive occupant comfort constraints. In the proposed approach, by separating the control mechanism into two layers above and below the load aggregator, MFC can be used below the aggregator to modulate flexible building loads in response to pricing signals with guaranteed performance. This allows the burden of identifying an accurate model of the system to be shifted to the above-aggregator layer, where fluctuations in individual building usage have less impact on predicted building system behavior. Game theory concepts can then be used to determine pricing curves and control signals among regional aggregators. Managing this control in a game-theoretic approach will allow us to build in financial incentives that increase customer engagement. Additionally, the usage of MFC necessitates less burdensome computational and communication requirements, thus, it is easily deployable on small, embedded devices. In a broader sense, developing a strategy capable of effectively incorporating residential and small commercial buildings will allow greater throughput of existing and emerging grid services in addition to future transactive energy grid management methods. Using MFC within a hierarchical control architecture will allow the shifting of existing forecasting challenges to an aggregate level, where dynamics are slower and more predictable. This will enable a smooth interface between the grid services requests of utilities and the reliable control required by participating buildings. MFC, which supports distributed control architecture, permits a scalable solution that can be deployed to neighborhood-size systems as well as individual buildings. This project focuses on three objectives: (1) developing the mathematical framework, algorithm toolkit, and software toolset of the two-layer transactive control testbed; (2) developing a scalable solution for application over many residential and small-size commercial buildings with sparse distributed communication; and (3) field testing and implementation on hardware of the control strategies developed in the previous two objectives. The research and development activities are focused and designed to be impactful within the relevant 2025 targets timeframe. An open-source control framework for exploiting variability and dispatchability of building loads will be delivered as the outcome of the project. This capability enables greater participation of loads in electricity markets and ancillary services that are both useful for the utility and financially beneficial for building owners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Digital System-On-Chip CO 2 Sensor (Final Report)

The overall goal of the project was to build a low-cost digital CO 2 sensor made of N5’s patented sensing architecture using a digital application specific integrated circuit (ASIC) to reduce the amount of energy usage in residential and commercial buildings. The proposed small form-factor CO 2 monitoring device contains a molecular sieve membrane filter capable of monitoring indoor air quality which indicates the content of CO 2 inside a residential or commercial building.

36 MATERIALS SCIENCE↗

Design, evaluation and recommedation effort relating to the modification of a residential 3-ton absorption cycle cooling unit for operation with solar energy

The possible use of solar energy powered absorption units to provide cooling and heating of residential buildings is studied. Both, the ammonia-water and the water-lithium bromide cycles, are considered. It is shown that the air cooled ammonia water unit does not meet the criteria for COP and pump power on the cooling cycle and the heat obtained from it acting as a heat pump is at too low a temperature. If the ammonia machine is water cooled it will meet the design criteria for cooling but can not supply the heating needs. The water cooled lithium bromide unit meets the specified performance for cooling with appreciably lower generator temperatures and without a mechanical solution pump. It is recommeded that in the demonstration project a direct expansion lithium bromide unit be used for cooling and an auxiliary duct coil using the solar heated water be employed for heating.

Merrick, R. H.↗

Integration of Thermoelectric Modules to Vapor Compression Systems

This paper describes the technology of a thermoelectric (TE) integrated heat pump. It uses a TE heat pump to subcool the refrigerant liquid before entering the evaporator to enlarge the evaporating capacity; and elevate the heat in the refrigerant flow to a supplemental heating coil and discharge the capacity to the indoor air flow. Using the DOE/ORNL Heat Pump Design Model, four system configurations were modelled on a baseline two-speed heat pump, the baseline heat pump with adding a supplemental coil, the TE integrated heat pump having one stage TE heating to control a 20R liquid refrigerant temperature drop; and having two stages TE heating to control up to 40R temperature drop. The system models were used to produce performance curves for EnergyPlus building energy simulations. We selected template residential buildings, poorly insulated: pre-1990 buildings, and well-insulated: IECC2021 buildings; in five cold climate zones: 5A, 5B, 6A, 6B, 7. The building energy simulations demonstrated energy saving potentials, utility cost reductions and estimated payback periods.

Shen, Bo↗

Market potential for solar heating and cooling in buildings

The use of solar heating and cooling for buildings as a method of conserving fossil fuels is discussed. The residential and commercial end use consumption of energy is tabulated. A survey to project the energy requirements for home and industry heating and cooling is developed. The survey indicates that there is a market potential for solar heating and cooling of buildings. A prediction of three to five billion dollars per year as the potential for solar heating and cooling is made.

Source record↗

Simulation, Challenge Testing & Validation of Occupancy Recognition & CO 2 Technologies (Final Project Report)

This final report covers the results of the development of testing methods of occupancy sensor systems connected to HVAC controls. This project focused on the development of test methods to evaluate the performance of HVAC-connected occupancy sensor systems, including occupancy presence, occupancy counting, and CO 2 sensor systems in commercial and residential buildings. This included evaluation of the reliability, ease of commissioning, and energy savings potential of these sensor systems. The results of this work help to standardize the methods used to evaluate performance, to enable the ability to compare sensor system performance following the same methods, to understand which sensor systems perform better or worse compared to others. The U.S. building stock’s energy usage can benefit substantially from having building system operations informed by reliable occupancy recognition and CO 2 measurements, however to date, standard methods have not been in place to ensure that sensor systems’ reported performance is uniformly evaluated. The results of this work support the development of a standard or guideline that outlines the developed methods of testing. This project also included the testing of both off-the-shelf and novel SENSOR team-developed low-cost occupancy sensor systems, using the developed methods of testing. The results of this testing helped to inform further development and improvement of new low-cost sensor systems that will benefit from being used in residential and commercial buildings throughout the country.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Interior Cellular Shades in a Residential Building

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope and sometimes from unwanted solar heat gain. Window attachments can help to mitigate this demand by controlling the solar heat gains and enhancing the thermal resistance of the windows. In this study, the energy savings potential of cellular shades in residential homes is studied using experimental testing and energy simulations. The energy performance of the shading devices was experimentally tested during the heating season from December 2019 to May 2020 with a focus on cellular shades. Five shading devices—three single and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal (venetian) blinds using two nearly identical sideby-side rooms in a residential building with their exterior window facing east. Another objective of the experimental testing was to evaluate any impact of the side-channel of the shading device on energy savings. To observe the impact of the side-channels on energy savings, from shades in two of the test cases, cellular shades with side-channels were used. From the experimental testing, daily energy savings in the range of 9% to 23% were observed by considering data from 6 p.m. until 6 a.m. of the next day.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart thermostat data-driven U.S. residential occupancy schedules and development of a U.S. residential occupancy schedule simulator

Occupancy schedule is one of the key inputs in Building Energy Modeling (BEM) to reflect the interaction between buildings and occupants. Over the past decades, standardized occupancy schedules, developed mainly by engineering rule-of-thumb, have been widely used in BEM due to its simplicity and lack of real measured occupancy data. However, the BEM community has recognized their association with uncertainty and reliability in simulation results from BEM. This study introduces representative occupancy schedules in the U.S. residential buildings, derived from a large smart thermostat dataset and time-series K-means clustering, and an open-source tool to generate a stochastic residential occupancy schedule. Over 90,000 residential occupancy schedules were estimated from the ecobee Donate Your Data dataset. Then, the representative occupancy schedules were identified through clustering. This study further investigated the impacts of three parameters (day, house type, and state) on residential occupancy schedules. Then, a tool, the Residential Occupancy Schedule Simulator (ROSS), is developed using the representative occupancy schedules derived in this study. Details of this tool are presented in this paper. In conclusion, the derived representative occupancy schedules and the ROSS tool can help improve the energy modeling of residential buildings.

42 ENGINEERING↗

Nova Analysis: Holistically Valuing the Contributions of Residential Efficiency, Solar and Storage

Policies to address climate change and grid modernization, in combination with cost reductions and technological advancements in energy efficiency (EE) and distributed energy resources (DER), are driving rapid deployment of building electrification and energy efficiency retrofits, rooftop solar photovoltaics (PV), smart thermostats, smart water heaters, and battery energy storage. In residential buildings, there are multiple stakeholders (occupant, utility, aggregator, society at large) that are each focused on different value streams. This project uses a suite of metrics intended to all of these value streams to try to holistically analyze the benefits that come from solar, storage, and energy efficiency. To demonstrate the value of these metrics, a semi annual study was performed simulating hundreds of homes across the U.S. under several different upgrade scenarios.

14 SOLAR ENERGY↗

Analysis of Building Model Forecasts using Autonomous HVAC Optimization System for Residential Neighborhood

Heating, ventilation, and air conditioning (HVAC) systems account for the highest share of home energy consumption in the United States. Optimized HVAC control can provide thermal improved comfort to the occupants, improve energy efficiency, reduce energy cost, and support grid services. In this paper, we discuss a multi-agent and cloud-based software framework that has been deployed in occupied residential neighborhood. This system enables automatic data collection, learning, optimization, and dispatches signals to neighborhood devices. HVAC optimization is based on model predictive control (MPC). Since the operational performance of MPC depends on model forecasting accuracy, it is crucial to evaluate the model continuously and modify or retrain it as necessary. In this research, we developed an automated workflow to evaluate the performance of temperature and power forecasts based on measured data in the real world. This will provide researchers with a deeper understanding of the model and how it can be improved.

Lebakula, Viswadeep↗

End-Use Load Profiles for the U.S. Building Stock

The United States is embarking on an ambitious transition to a 100% clean energy economy by 2050, which will require improving the flexibility of electric grids. One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High quality end-use load profiles (EULPs) provide this information, and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation. To help fill this gap, the U.S. Department of Energy (DOE) funded a three-year project, End-Use Load Profiles for the U.S. Building Stock, that culminated in this publicly available dataset of calibrated and validated 15-minute resolution load profiles for all major residential and commercial building types and end uses, across all climate regions in the United States. These EULPs were created by calibrating the ResStock and ComStock physics-based building stock models using many different measured datasets, as described in the "Technical Report Documenting Methodology" linked in the submission.

Array↗