Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Relative accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Comparative accuracy of diffuse radiative properties computed using selected multiple scattering approximations

Computational results have been obtained for the spherical albedo, global transmission, and global absorption of plane-parallel layers composed of cloud droplets. These computations, obtained using the doubling method for the entire range of single scattering albedos and for optical depths between 0.1 and 100, are compared with corresponding results obtained using selected multiple scattering approximations. The spherical albedo and global absorption computed using asymptotic theory are found to be accurate to better than 5 percent for all values of the single scattering albedo, provided the optical thickness exceeds about 2. The diffuse two-stream approximations have relative accuracies that are much worse than 5 percent for the spherical albedo over most of the parameter space, yet are accurate to within 5 percent in the global absorption when the absorption is significant. The integrated delta-Eddington scheme appears to be the most suitable model over the entire range of variables, generally producing relative errors of less than 5 percent in both the spherical albedo and global absorption.

HARSHVARDHAN↗

Remote Distributed Vibration Sensing Through Opaque Media Using Permanent Magnets

Vibration sensing is critical for a variety of applications from structural fatigue monitoring to understanding the modes of airplane wings. In particular, remote sensing techniques are needed for measuring the vibrations of multiple points simultaneously, assessing vibrations inside opaque metal vessels, and sensing through smoke clouds and other optically challenging environments. Here, in this paper, we propose a method which measures high-frequency displacements remotely using changes in the magnetic field generated by permanent magnets. We leverage the unique nature of vibration tracking and use a calibrated local model technique developed specifically to improve the frequency-domain estimation accuracy. The results show that two-dimensional local models surpass the dipole model in tracking high-frequency motions. A theoretical basis for understanding the effects of electronic noise and error due to correlated variables is generated in order to predict the performance of experiments prior to implementation. Simultaneous measurements of up to three independent vibrating components are shown. The relative accuracy of the magnet-based displacement tracking with respect to the video tracking ranges from 40 to 190 μm when the maximum displacements approach ±5 mm and when sensor-to-magnet distances vary from 25 to 36 mm. Finally, vibration sensing inside an opaque metal vessel and mode shape changes due to damage on an aluminum beam are also studied using the wireless permanent-magnet vibration sensing scheme.

42 ENGINEERING↗

U-Pu and Ba-Cs isotopic measurements on Trinitite by laser ablation sampling on the Neoma MC-ICP-MS

In this study we present the results of combined U-Pu and Ba-Cs isotope measurements obtained by laser ablation (LA) sampling of two glassy debris fragments (‘Trinitite’) from the world's first atomic bomb detonation conducted in New Mexico on July 16, 1945. Our primary goal in conducting these measurements was to understand whether examination of the U-Pu and Ba-Cs systematics by direct sampling (e.g. without any chemical separation or purification prior to isotope ratio measurement) could yield meaningful information that would differentiate the Trinitite fragments from glassy material lacking a nuclear fission signature. These measurements were conducted on a ThermoFisher Scientific Neoma multi collector – inductively coupled plasma – mass spectrometer (MC-ICP-MS), which is a relatively new MC-ICP-MS platform, so we also examine the behavior of these isotope systems in standards sampled in solution and via LA. Unsurprisingly, the measurements made on purified solutions of the U, Pu, and Ba isotopic standards produce high precision isotope ratios. Furthermore, this extends to the U-Pu measurements made by LA sampling, with the expected degradation in precision and accuracy related to matrix effects and signal intensity fluctuation. However, the Ba-Cs data acquired by LA is of low precision across all of the matrices examined and bears evidence of complex mass fractionation that will require further investigation to resolve. In total, our results indicate that the observed U-Pu isotope data are of sufficient quality to accurately constrain the U and Pu isotopic composition of glass containing sub-ppm levels of these elements which in turn could be used to differentiate glass containing anthropogenic fission products from natural glass whereas the Ba-Cs LA data cannot be used for this purpose until further methodological refinement is performed.

Ba-Cs↗

Accuracy Analysis and Validation of the Mars Science Laboratory (MSL) Robotic Arm

The Mars Science Laboratory (MSL) Curiosity Rover is currently exploring the surface of Mars with a suite of tools and instruments mounted to the end of a five degree-of-freedom robotic arm. To verify and meet a set of end-to-end system level accuracy requirements, a detailed positioning uncertainty model of the arm was developed and exercised over the arm operational workspace. Error sources at each link in the arm kinematic chain were estimated and their effects propagated to the tool frames.A rigorous test and measurement program was developed and implemented to collect data to characterize and calibrate the kinematic and stiffness parameters of the arm. Numerous absolute and relative accuracy and repeatability requirements were validated with a combination of analysis and test data extrapolated to the Mars gravity and thermal environment. Initial results of arm accuracy and repeatability on Mars demonstrate the effectiveness of the modeling and test program as the rover continues to explore the foothills of Mount Sharp.

rovers↗

Evaluating the accuracy of common γ-Al 2 O 3 structure models by selected area electron diffraction from high-quality crystalline γ-Al 2 O 3

Single crystal and textured polycrystalline γ-Al 2 O 3 thin films were synthesized by oxidation of NiAl(110) in air at 850 °C for 1 and 2 hours, respectively, and used to evaluate the accuracy of two spinel-based and two nonspinel models by comparison of selected-area electron diffraction (SAED). The lattice interplanar distances derived from the polycrystalline SAED pattern most closely matched the cubic spinel γ-Al 2 O 3 model. The single-crystal SAED spot pattern reflected symmetry consistent with both the cubic spinel and tetragonal nonspinel models, yet, the Al cation distribution better matched the cubic spinel model based on the relative intensities of diffraction spots. Our work indicates that the traditional cubic spinel model is a more accurate model of γ-Al 2 O 3 than the other models considered. Furthermore, the spinel-based monoclinic model is more accurate than the monoclinic nonspinel model. The understanding of the relative accuracy of the different models is key for simulating γ-Al 2 O 3 containing systems and is of general interest for the metal oxide and ceramic communities.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Depth-resolved registration of transesophageal echo to x-ray fluoroscopy using an inverse geometry fluoroscopy system

Purpose: Image registration between standard x-ray fluoroscopy and transesophageal echocardiography (TEE) has recently been proposed. Scanning-beam digital x-ray (SBDX) is an inverse geometry fluoroscopy system designed for cardiac procedures. This study presents a method for 3D registration of SBDX and TEE images based on the tomosynthesis and 3D tracking capabilities of SBDX. Methods: The registration algorithm utilizes the stack of tomosynthetic planes produced by the SBDX system to estimate the physical 3D coordinates of salient key-points on the TEE probe. The key-points are used to arrive at an initial estimate of the probe pose, which is then refined using a 2D/3D registration method adapted for inverse geometry fluoroscopy. A phantom study was conducted to evaluate probe pose estimation accuracy relative to the ground truth, as defined by a set of coregistered fiducial markers. This experiment was conducted with varying probe poses and levels of signal difference-to-noise ratio (SDNR). Additional phantom and in vivo studies were performed to evaluate the correspondence of catheter tip positions in TEE and x-ray images following registration of the two modalities. Results: Target registration error (TRE) was used to characterize both pose estimation and registration accuracy. In the study of pose estimation accuracy, successful pose estimates (3D TRE < 5.0 mm) were obtained in 97% of cases when the SDNR was 5.9 or higher in seven out of eight poses. Under these conditions, 3D TRE was 2.32 ± 1.88 mm, and 2D (projection) TRE was 1.61 ± 1.36 mm. Probe localization error along the source-detector axis was 0.87 ± 1.31 mm. For the in vivo experiments, mean 3D TRE ranged from 2.6 to 4.6 mm and mean 2D TRE ranged from 1.1 to 1.6 mm. Anatomy extracted from the echo images appeared well aligned when projected onto the SBDX images. Conclusions: Full 6 DOF image registration between SBDX and TEE is feasible and accurate to within 5 mm. Future studies will focus on real-time implementation and application-specific analysis.

60 APPLIED LIFE SCIENCES↗

The generalized liquid drop model alpha-decay formula: Predictability analysis and superheavy element alpha half-lives

The predictive accuracy of the generalized liquid drop model (GLDM) formula for alpha-decay half-lives has been investigated in a detailed manner and a variant of the formula with improved coefficients is proposed. The method employs the experimental alpha half-lives of the well-known alpha standards to obtain the coefficients of the analytical formula using the experimental Q{sub {alpha}} values (the DSR-E formula), as well as the finite range droplet model (FRDM) derived Q{sub {alpha}} values (the FRDM-FRDM formula). The predictive accuracy of these formulae was checked against the experimental alpha half-lives of an independent set of nuclei (TEST) that span approximately the same Z, A region as the standards and possess reliable alpha spectroscopic data, and were found to yield good results for the DSR-E formula but not for the FRDM-FRDM formula. The two formulae were used to obtain the alpha half-lives of superheavy elements (SHE) and heavy nuclides where the relative accuracy was found to be markedly improved for the FRDM-FRDM formula, which corroborates the appropriateness of the FRDM masses and the GLDM prescription for high Z, A nuclides. Further improvement resulted, especially for the FRDM-FRDM formula, after a simple linear optimization over the calculated and experimental half-lives of TEST was used to re-calculate the half-lives of the SHE and heavy nuclides. The advantage of this optimization was that it required no re-calculation of the coefficients of the basic DSR-E or FRDM-FRDM formulae. The half-lives for 324 medium-mass to superheavy alpha decaying nuclides, calculated using these formulae and the comparison with experimental half-lives, are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A surrogate-model-based approach for estimating the first and second-order moments of offshore wind power

Power curve, the functional relationship that governs the process of converting a set of weather variables experienced by a wind turbine into electric power, is widely used in the wind industry to estimate power output for planning and operational purposes. Existing methods for power curve estimation have three main limitations: (i) they mostly rely on wind speed as the sole input, thus ignoring the secondary, yet possibly significant effects of other environmental factors, (ii) they largely overlook the complex marine environment in which offshore turbines operate, potentially compromising their value in offshore wind energy applications, and (ii) they solely focus on the first-order properties of wind power, with little (or null) information about the variation around the mean behavior, which is important for ensuring reliable grid integration, asset health monitoring, and energy storage, among others. In light of that, this study investigates the impact of several wind-and wave-related factors on offshore wind power variability, with the ultimate goal of accurately predicting its first two moments. Further, our approach couples OpenFAST—a multi-physics wind turbine simulator—with Gaussian Process (GP) regression to reveal the underlying relationships governing offshore weather-to-power conversion. We first find that a multi-input power curve which captures the combined impact of wind speed, direction, and air density, can provide double-digit improvements, in terms of prediction accuracy, relative to univariate methods which rely on wind speed as the sole explanatory variable (e.g. the standard method of bins). Wave-related variables are found not important for predicting the average power output, but interestingly, appear to be extremely relevant in describing the fluctuation of the offshore power around its mean. Tested on real-world data collected at the New York/New Jersey bight, our proposed multi-input models demonstrate a high explanatory power in predicting the first two moments of offshore wind generation, testifying their potential value to the offshore wind industry.

17 WIND ENERGY↗

Carbon Dioxide Active Remote Sensing Using Pulsed 2-µm Lidar

A pulsed 2-µm Integrate Path Differential Absorption (IPDA) lidar was developed at NASA Langley Research Center for high-accuracy and high-precision measurements of atmospheric carbon dioxide (CO 2 ). The instrument targets the R30 CO 2 absorption line and implements high-energy tunable on-line transmitter and advanced HgCdTe avalanche photodiode receiver. During 2019 airborne validation campaign, the IPDA was tested over the ocean for retrieving the weighted-average column dry-air volume mixing ratio of CO 2 (XCO 2 ) from 4.5 km altitude. XCO 2 measurement resulted in 404.43 ± 1.23 ppm using 10 s average, as compared to 405.49 ppm from prediction models. This translates to 0.26% and 0.30% relative accuracy and precision, respectively. Performance models were updated to scale the IPDA technology assuming operation from space platform. Results present XCO 2 measurements using the instrument capabilities considering different target scenarios for Earth’s surface. This demonstrates the potential for the IPDA technique and technology to achieve sustained global CO 2 measurement.

Active Remote Sensing↗

Carbon Dioxide Active Remote Sensing Using Pulsed 2-µm Lidar

A pulsed 2-µm Integrate Path Differential Absorption (IPDA) lidar was developed at NASA Langley Research Center for high-accuracy and high-precision measurements of atmospheric carbon dioxide (CO 2 ). The instrument targets the R30 CO 2 absorption line and implements high-energy tunable on-line transmitter and advanced HgCdTe avalanche photodiode receiver. During 2019 airborne validation campaign, the IPDA was tested over the ocean for retrieving the weighted-average column dry-air volume mixing ratio of CO 2 (XCO 2 ) from 4.5 km altitude. XCO 2 measurement resulted in 404.43 ± 1.23 ppm using 10 s average, as compared to 405.49 ppm from prediction models. This translates to 0.26% and 0.30% relative accuracy and precision, respectively. Performance models were updated to scale the IPDA technology assuming operation from space platform. Results present XCO 2 measurements using the instrument capabilities considering different target scenarios for Earth’s surface. This demonstrates the potential for the IPDA technique and technology to achieve sustained global CO 2 measurement.

Active Remote Sensing↗

DMSP-SSM/1 NASA algorithm validation using primarily LANDSAT and secondarily DMSP and/or AVHRR visible and thermal infrared satellite imagery

The approach to the DMSP SSMI (Defense Meteorological Satellite Program; Special Sensor Microwave Imager) sea-ice validation effort is to demonstrate a quantitative relationship between the SSMI-derived sea ice parameters and those same parameters derived from other data sets including visible and infrared satellite imagery, aerial photographic and high-resolution microwave aircraft imagery. The question to be addressed is to what accuracy (relative to these other observations) can the following ice parameters be determined: (1) position of the ice boundary; (2) total sea ice concentration; and (3) multiyear sea ice concentration. Specific tasks include: (1) a study of the interrelationship of surface information content and sensor spatial and spectral resolution in order to establish relationships between ice surface features and the manner in which they are expressed in the satellite observations; and (2) apply these relationships to map the sea ice features which can be used to evaluate NASA's proposed SSM/1 sea ice algorithms. Other key points to be addressed include the accuracy to which these parameters can be determined in different regions (marginal ice zone such as Bering Sea, Arctic ocean, such as Beaufort Sea); the accuracy of these parameters for different seasons; the accuracy of the algorithms weather filter under different weather conditions; and the effectiveness of the 85.5 GHz channels to locate the ice edge.

Steffen, K.↗

Multi-Parameter Aerosol Scattering Sensor

This work relates to the development of sensors that measure specific aerosol properties. These properties are in the form of integrated moment distributions, i.e., total surface area, total mass, etc., or mathematical combinations of these moment distributions. Specifically, the innovation involves two fundamental features: a computational tool to design and optimize such sensors and the embodiment of these sensors in actual practice. The measurement of aerosol properties is a problem of general interest. Applications include, but are not limited to, environmental monitoring, assessment of human respiratory health, fire detection, emission characterization and control, and pollutant monitoring. The objectives for sensor development include increased accuracy and/or dynamic range, the inclusion in a single sensor of the ability to measure multiple aerosol properties, and developing an overall physical package that is rugged, compact, and low in power consumption, so as to enable deployment in harsh or confined field applications, and as distributed sensor networks. Existing instruments for this purpose include scattering photometers, direct-reading mass instruments, Beta absorption devices, differential mobility analyzers, and gravitational samplers. The family of sensors reported here is predicated on the interaction of light and matter; specifically, the scattering of light from distributions of aerosol particles. The particular arrangement of the sensor, e.g. the wavelength(s) of incident radiation, the number and location of optical detectors, etc., can be derived so as to optimize the sensor response to aerosol properties of practical interest. A key feature of the design is the potential embodiment as an extremely compact, integrated microsensor package. This is of fundamental importance, as it enables numerous previously inaccessible applications. The embodiment of these sensors is inherently low maintenance and high reliability by design. The novel and unique features include the underlying computational underpinning that allows the optimization for specific applications, and the physical embodiment that affords the construction of a compact, durable, and reliable integrated package. The advantage appears in the form of increased accuracy relative to existing instruments, and the applications enabled by the physical attributes of the resulting configuration

Greenberg, Paul S.↗

Study of e{sup +}e{sup -}{yields}H{sup 0}A{sup 0} production and the constraint on dark matter density

This paper reports the results of a study of the supersymmetric neutral heavy Higgs boson production process e{sup +}e{sup -}{yields}H{sup 0}A{sup 0} at {radical}(s)=1 TeV performed using fully simulated and reconstructed events. The adopted parameters for the supersymmetric models are compatible with the relic dark matter density if this is due to neutralinos annihilating through the A{sup 0} boson in the early universe. The accuracies on the heavy Higgs boson masses, widths, and decay branching fractions are estimated to be {delta}M{sub A{sup 0}}/M{sub A{sup 0}}=0.0024 {delta}{gamma}{sub A{sup 0}}/{gamma}{sub A{sup 0}}=0.19, {delta}BR(A{sup 0}{yields}bb)/BR(A{sup 0}{yields}bb)=0.07, and {delta}BR(A{sup 0}{yields}{tau}{sup +}{tau}{sup -})/BR(A{sup 0}{yields}{tau}{sup +}{tau}{sup -})=0.15 These results, combined with other measurements from the LHC and an e{sup +}e{sup -} collider, allow the supersymmetric dark matter density to be inferred to a relative accuracy {delta}{omega}{sub {chi}}h{sup 2}/{omega}{sub {chi}}h{sup 2}=0.08.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accurate Measurements of the Dielectric Constant of Seawater at L Band

This report describes measurements of the dielectric constant of seawater at a frequency of 1.413 GHz that is at the center of the L-Sand radiometric protected frequency spectrum. Aquarius will be sensing the sea surface salinity from space in this band. The objective of the project is to refine the model function for the dielectric constant as a function of salinity and temperature so that remote sensing measurements can be made with the accuracy needed to meet the measurement goals (0.2 psu) of the Aquarius mission. The measurements were made, using a microwave cavity operated in the transmission configuration. The cavity's temperature was accurately regulated to 0.02 C by immersing it in a temperature controlled bath of distilled water and ethanol glycol. Seawater had been purchased from Ocean Scientific International Limited (OS1L) at salinities of 30, 35 and 38 psu. Measurements of these seawater samples were then made over a range of temperatures, from l0 C to 35 C in 5 C intervals. Repeated measurements were made at each temperature and salinity, Mean values and standard deviations were then computed. Total error budgets indicated that the real and imaginary parts of the dielectric constant had a relative accuracy of about l%.

Lang, Roger H.↗

Assessment of Evolving TRMM-Based Real-Time Precipitation Estimation Methods and Their Impacts on Hydrologic Prediction in a High-Latitude Basin

The real-time availability of satellite-derived precipitation estimates provides hydrologists an opportunity to improve current hydrologic prediction capability for medium to large river basins. Due to the availability of new satellite data and upgrades to the precipitation algorithms, the Tropical Rainfall Measuring Mission (TRMM) Multi-satellite Precipitation Analysis real-time estimates (TMPA-RT) have been undergoing several important revisions over the past ten years. In this study, the changes of the relative accuracy and hydrologic potential of TMPA-RT estimates over its three major evolving periods were evaluated and inter-compared at daily, monthly and seasonal scales in the high-latitude Laohahe basin in China. Assessment results show that the performance of TMPA-RT in terms of precipitation estimation and streamflow simulation was significantly improved after 3 February 2005. Overestimation during winter months was noteworthy and consistent, which is suggested to be a consequence from interference of snow cover to the passive microwave retrievals. Rainfall estimated by the new version 6 of TMPA-RT starting from 1 October 2008 to present has higher correlations with independent gauge observations and tends to perform better in detecting rain compared to the prior periods, although it suffers larger mean error and relative bias. After a simple bias correction, this latest dataset of TMPA-RT exhibited the best capability in capturing hydrologic response among the three tested periods. In summary, this study demonstrated that there is an increasing potential in the use of TMPA-RT in hydrologic streamflow simulations over its three algorithm upgrade periods, but still with significant challenges during the winter snowing events.

hydrologic prediction↗

A UNIFORM ASTEROSEISMIC ANALYSIS OF 22 SOLAR-TYPE STARS OBSERVED BY KEPLER

Asteroseismology with the Kepler space telescope is providing not only an improved characterization of exoplanets and their host stars, but also a new window on stellar structure and evolution for the large sample of solar-type stars in the field. We perform a uniform analysis of 22 of the brightest asteroseismic targets with the highest signal-to-noise ratio observed for 1 month each during the first year of the mission, and we quantify the precision and relative accuracy of asteroseismic determinations of the stellar radius, mass, and age that are possible using various methods. We present the properties of each star in the sample derived from an automated analysis of the individual oscillation frequencies and other observational constraints using the Asteroseismic Modeling Portal (AMP), and we compare them to the results of model-grid-based methods that fit the global oscillation properties. We find that fitting the individual frequencies typically yields asteroseismic radii and masses to {approx}1% precision, and ages to {approx}2.5% precision (respectively, 2, 5, and 8 times better than fitting the global oscillation properties). The absolute level of agreement between the results from different approaches is also encouraging, with model-grid-based methods yielding slightly smaller estimates of the radius and mass and slightly older values for the stellar age relative to AMP, which computes a large number of dedicated models for each star. The sample of targets for which this type of analysis is possible will grow as longer data sets are obtained during the remainder of the mission.

79 ASTRONOMY AND ASTROPHYSICS↗

Coupled high fidelity thermal hydraulics and neutronics for reactor safety simulations

This work is a continuation of previous work on the importance of accuracy in the simulation of nuclear reactor safety transients. This work is qualitative in nature and future work will be more quantitative. The focus of this work will be on a simplified single phase nuclear reactor primary. The transient of interest investigates the importance of accuracy related to passive (inherent) safety systems. The transient run here will be an Unprotected Loss of Flow (ULOF) transient. Here the coolant pump is turned off and the un’SCRAM’ed reactor transitions from forced to free convection (Natural circulation). Results will be presented that show the difference that the first order in time truncation physics makes on the transient. The purpose of this document is to illuminate a possible problem in traditional reactor simulation approaches. Detailed studies need to be done on each simulation code for each transient analyzed to determine if the first order truncation physics plays an important role.

99 GENERAL AND MISCELLANEOUS↗