Charging and ExB rotation of ablation clouds surrounding refueling pellets in hot fusion plasmas

The finite resistivity magnetohydrodynamic code FRONTIER-MHD[R. Samulyak et al., Nucl. Fusion 47, 103 (2007)] is used to simulate the ablation rate of refueling pellets, including the novel effect of electrostatically induced ExB rotation of the ablation cloud about its symmetry axis parallel to the magnetic field. The key finding is that the centrifugal force of cloud rotation pushes the cloud density radially outwards, creating a more ''transparent'' ablation channel. With reduced shielding, the steady state ablation rate of a deuterium pellet significantly increases from {approx}35% to 100%, depending on the B-field strength. This new effect brings the ablation rate into better accord with a known theoretical scaling law, which agrees with most current experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Core and Refueling Design Studies for the Advanced High Temperature Reactor

The Advanced High Temperature Reactor (AHTR) is a design concept for a central generating station type [3400 MW(t)] fluoride-salt-cooled high-temperature reactor (FHR). The overall goal of the AHTR development program is to demonstrate the technical feasibility of FHRs as low-cost, large-size power producers while maintaining full passive safety. This report presents the current status of ongoing design studies of the core, in-vessel structures, and refueling options for the AHTR. The AHTR design remains at the notional level of maturity as important material, structural, neutronic, and hydraulic issues remain to be addressed. The present design space exploration, however, indicates that reasonable options exist for the AHTR core, primary heat transport path, and fuel cycle provided that materials and systems technologies develop as anticipated. An illustration of the current AHTR core, reactor vessel, and nearby structures is shown in Fig. ES1. The AHTR core design concept is based upon 252 hexagonal, plate fuel assemblies configured to form a roughly cylindrical core. The core has a fueled height of 5.5 m with 25 cm of reflector above and below the core. The fuel assembly hexagons are {approx}45 cm across the flats. Each fuel assembly contains 18 plates that are 23.9 cm wide and 2.55 cm thick. The reactor vessel has an exterior diameter of 10.48 m and a height of 17.7 m. A row of replaceable graphite reflector prismatic blocks surrounds the core radially. A more complete reactor configuration description is provided in Section 2 of this report. The AHTR core design space exploration was performed under a set of constraints. Only low enrichment (<20%) uranium fuel was considered. The coated particle fuel and matrix materials were derived from those being developed and demonstrated under the Department of Energy Office of Nuclear Energy (DOE-NE) advanced gas reactor program. The coated particle volumetric packing fraction was restricted to at most 40%. The pressure drop across the core was restricted to no more than 1.5 atm during normal operation to minimize the upward force on the core. Also, the flow velocity in the core was restricted to 3 m/s to minimize erosion of the fuel plates. Section 3.1.1 of this report discusses the design restrictions in more detail.

Holcomb, David Eugene↗

Community Energy: Analysis of Hydrogen Distributed Energy Systems with Photovoltaics for Load Leveling and Vehicle Refueling

Energy storage could complement PV electricity generation at the community level. Because PV generation is intermittent, strategies must be implemented to integrate it into the electricity system. Hydrogen and fuel cell technologies offer possible PV integration strategies, including the community-level approaches analyzed in this report: (1) using hydrogen production, storage, and reconversion to electricity to level PV generation and grid loads (reconversion scenario); (2) using hydrogen production and storage to capture peak PV generation and refuel hydrogen fuel cell electric vehicles (FCEVs) (hydrogen fueling scenario); and (3) a comparison scenario using a battery system to store electricity for EV nighttime charging (electric charging scenario).

08 HYDROGEN↗

Venting losses from the LH 2 trailer at the refueling station

LH 2 trailers typically vent significant amounts of vapor following delivery at a refueling station. See for example the picture on Fig. 1 of the vapor cloud due to the depressurization of trailer #7016 at LLNL. That practice is possibly too conservative with regards to the Code of Federal Regulations.

25 ENERGY STORAGE↗

Refueling Station, Ethanol, Operation

This unit process includes the emissions from the operation of a refueling station for an ethanol and gasoline blended fuel. Electricity demand and emissions from fuel evaporation during station filling and vehicle filling are also included. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=1983FDBF-2320-46C2-A043-BF8A14B120B1

09 BIOMASS FUELS↗

Refueling Station, Diesel, Operation

This unit process includes the emissions from operation of a refueling station for diesel. Emissions from fuel evaporation during storage and tank loading and unloading operations are included. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=589BCDAD-F002-4373-A905-50C80B1CEF2E

02 PETROLEUM↗

Hydrogen Refueling Reference Station Lot Size Analysis for Urban Sites

Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) is a project initiated by the DOE in 2015 and executed by Sandia National Laboratories and the National Renewable Energy Laboratory to address R&D barriers to the deployment of hydrogen fueling infrastructure. One key barrier to the deployment of fueling stations is the land area they require (i.e. "footprint"). Space is particularly a constraint in dense urban areas where hydrogen demand is high but space for fueling stations is limited. This work presents current fire code requirements that inform station footprint, then identifies and quantifies opportunities to reduce footprint without altering the safety profile of fueling stations. Opportunities analyzed include potential new methods of hydrogen delivery, as well as alternative placements of station technologies (i.e. rooftop/underground fuel storage). As interest in heavy-duty fueling stations and other markets for hydrogen grows, this study can inform techniques to reduce the footprint of heavy-duty stations as well. This work characterizes generic designs for stations with a capacity of 600 kg/day hydrogen dispensed and 4 dispenser hoses. Three base case designs (delivered gas, delivered liquid, and on-site electrolysis production) have been modified in 5 different ways to study the impacts of recently released fire code changes, colocation with gasoline refueling, alternate delivery assumptions, underground storage of hydrogen, and rooftop storage of hydrogen, resulting in a total of 32 different station designs. The footprints of the base case stations range from 13,000 to 21,000 ft 2 . A significant focus of this study is the NFPA 2 requirements, especially the prescribed setback distances for bulk gaseous or liquid hydrogen storage. While the prescribed distances are large in some cases, these setback distances are found to have a nuanced impact on station lot size; considerations of the delivery truck path, traffic flow, parking, and convenience store location are also important. Station designs that utilize underground and rooftop storage can reduce footprint but may not be practical or economical. For example, burying hydrogen storage tanks underground can reduce footprint, but the cost savings they enable depend on the cost of burial and the cost land. Siting and economic analysis of station lot sizes illustrate the benefit of smaller station footprints in the flexibility and cost savings they can provide. This study can be used as a reference that provides examples of the key design differences that fueling stations can incorporate, the approximate sizes of generic station lots, and considerations that might be unique to particular designs.

08 HYDROGEN↗

The HyRIGHT Project: 700 bar Hydrogen Refueling Interface for Gaseous Heavy-Duty Trucks

Heavy duty truck fueling places additional constraints on the station. The HyRIGHT project was developed to evaluate a subset of key areas around precooling, communications, and safety risks that aims to:  Utilize a dynamic model that includes the relevant station components and vehicle to develop an optimized precooling strategy based on initial precooling status, real time communications that can support fueling protocol development.  Perform a techno economic cost assessment (TEA) related to effects of precooling including station storage and efficiency effects.  Develop a Cyber Vulnerability assessment and framework for refueling of HD vehicles with station communications.  Disseminate the results in support of the HD fueling protocol development to the relevant standards development organizations.

JAMES, Charles W.↗

Safety Codes and Standards Review and Gap Analysis for Applicability to Hydrogen Rail Refueling, Defueling, Maintenance, and Storage

Hydrogen-powered locomotives may present an alternative to diesel for achieving transportation-related decarbonization, energy security, and resilience goals. As an emerging technology, hydrogen locomotives may not have adequate representation in current safety codes and standards. NFPA 2 and other appropriate codes and standards were reviewed to identify technical gaps in the code for hydrogen rail defueling, refueling, maintenance, and storage. Several technical gaps pertaining to setback distances, allowable quantities, ventilation rates, and grounding have been identified. Fueling requirements can be informed by road vehicle standards but may need to be revised for larger quantity hydrogen locomotive systems. Since there are no hydrogen-specific locomotive design and safety standards, some aspects of diesel-based locomotive standards may apply. CGA G- 5.5 currently provides the most guidance on height, placement, orientation, and design of vent systems, while other standards emphasize the importance of shielding vent stacks and provide requirements for orientation of their discharge.

08 HYDROGEN↗

Quantitative Risk Assessment for Fuel Cell Electric Bus Hydrogen Storage and Refueling Facility

It is necessary to understand the safety implications and risk mitigation options for fuel cell electric bus fleet deployment, especially for related facilities responsible for operations such as production, storage, compression, and dispensing of hydrogen for use by the buses. In this report, we present a quantitative risk assessment for a potential fuel cell electric bus fleet that was motivated by efforts to improve resilience at the Portland International Airport but can be applicable to a range of hydrogen case studies and use cases. We estimated risk for a facility that produces, stores, compresses, and dispenses hydrogen for the fleet of buses, with a focus on individual risk to people in terms of annual frequency of fatality. We considered the frequency of hydrogen leaks that could result in harmful physical outcomes like jet fires or explosions, and the consequences of those outcomes for people. We created customized fault trees to calculate the frequencies of different sizes of leaks and event sequence diagrams to calculate ignition probabilities for the various leak sizes. We also leveraged the HyRAM+ toolkit to use these inputs to calculate overall risk for the facility, which we separated into one section responsible for producing, storing, and compressing hydrogen, and one section responsible for dispensing the hydrogen to the buses. We found that the dispensing area seemed to have a higher risk than the production/storage/compression area of the facility, largely because of the inclusion of a component with a high leak frequency (the heat exchanger used to cool the hydrogen before entering the vehicle, to prevent overheating and expansion of hydrogen in the onboard tank). For the example production and refueling facility we evaluated and the data we used for the analysis, the leak frequency had a larger impact on the risk differences between the two sections on the facility, compared to the physical outcome consequence, which was slightly different due to the varying fuel conditions, but not substantially different. Actions can be taken to prevent these hazards (e.g., lowering leak frequencies in system components) or to mitigate the consequences if they do occur (e.g., installing barriers to protect people if ignition events occur). The choice of which actions to take depends not only on safety considerations but also on space, time, staffing, feasibility, and financial constraints. Therefore, the quantitative risk assessment approach can help understand relative risk contributions from different components, leak sizes, consequences, and human actions, to prioritize risk reduction strategies and balance these parameters. The outcomes of this report may be useful for a variety of stakeholders working in the hydrogen, transportation, vehicle, and aviation sector, including those responsible for aspects like facility design, operations, and regulations. There is not a single value of risk that determines whether a hypothetical system is “safe” or not. The insights about risk mitigations may be leveraged, and the quantitative risk assessment approach can be applied to other case studies to understand risk priorities and contributions specific to different FCEB and hydrogen facility uses.

08 HYDROGEN↗

Human Factors Considerations for Hydrogen Rail Refueling and Maintenance

The Federal Railroad Administration (FRA) contracted Sandia National Laboratories to review the risks introduced specifically through human interactions within hydrogen rail refueling and maintenance activities and present recommendations for future system development and implementation. Due to the lack of domestic hydrogen-powered trains at the time of review, observational data was collected on analogous existing systems to consider various ways hydrogen might be implemented within future designs. The team developed 50 human factors design guidelines through analysis of human risk factors. Because hydrogen rail systems are still in the early design stage, the resulting human factors guidelines represent general best practices and do not include specific design features. The research team recommends design and regulatory agencies include a Human Factors Engineer in the design and review process to ensure the guidelines are appropriately implemented and verified.

08 HYDROGEN↗

Automatic Volume Balancing for Online Refueling in Molten Salt Reactor Simulations with SCALE

This work introduces recently implemented capabilities in the SCALE code system’s TRITON reactor physics sequence that improve molten salt reactor (MSR) modeling: (1) a volume balancing option, which automatically balances the volumes of the fed material with a corresponding material removal to maintain fixed mixture volumes in the neutron transport model and accurate densities, and (2) continuous feed from mixtures, which enables users to define material feed streams directly from salt mixture definitions rather than individual nuclides. The new capabilities were demonstrated via SCALE/TRITON simulations of two representative MSR concepts. Simulations of the 180 MWth molten chloride fast reactor—a system with a fixed fuel salt volume in the reactor core—applied continuous refueling with fresh fuel salt. The results confirm approximately constant reactivity when the new volume balancing capability is used. Additionally, excellent agreement with a manual feed-and-drain method for volume balancing further verified the new implementation. Simulations of the 400 MWth EIRENE reactor, an integral MSR in which the salt volume may grow over time within the reactor core, demonstrated the capability to represent growing salt volume within the TRITON depletion calculation. Compared with reference solutions, the results show consistent trends in reactivity and isotopic evolution, confirming that these new user-friendly capabilities provide accurate, physically consistent approaches for modeling MSRs in SCALE.

Elzohery, Rabab [ORNL] (ORCID:0000000160043633)↗

An analysis of ullage heat transfer in the orbital refueling system

The Orbital Refueling System was an experiment flown on Shuttle Mission STS 41-G in October, 1984. Liquid hydrazine fuel was transferred back and forth from one spherical bladder tank to another using pressurized nitrogen as the driving force. Compressive heating of the ullage gas in the receiving tank could lead to a hazardous situation if any hydrazine leaked through to the ullage side of the bladder and was heated above about 175 F, where it can undergo spontaneous exothermic decomposition. Early analysis of the flight data indicated that the ullage compression process was much closer to an isothermal than an adiabatic one. In this study, a thorough review of the pertinent literature was used to make an a priori best-estimate for the ullage gas heat transfer coefficient (defining the Nusselt Number as a function of Reynolds and Rayleigh Numbers). Experimental data from the flight were analyzed in detail. It is evident that there is considerably more heat transfer than can be accounted for by conduction alone, but the observed increases do not correlate well with Reynolds Number, Rayleigh Number or vehicle acceleration. There are large gaps in the present understanding of convective heat transfer in closed containers with internal heat generation, especially in the presence of vibrations or other random disturbances. A program of experiments to fill in these gaps is suggested, covering both ground and orbital environments.

Kauffman, D.↗

The dynamics of a space station tethered refueling facility

The fluid stored in a tethered orbital refueling facility is settled at the bottom of the storage tanks by gravity-gradient forces. The fluid motions (slosh) induced by outside disturbances must be limited to ensure the tank outlet is not uncovered during a fluid transfer. The dynamics of a LO2/LH2 TORF attached to the space station have been analyzed to identify design parameters necessary to limit fluid motion. Using the worst case disturbance of a shuttle docking at the space station, the fluid motion was found to be a function of tether length and allowable facility swing angle. Acceptable fluid behavior occurs for tether lengths of at least 1000 ft. To ensure motions induced by separate disturbances do not add to unacceptable values, a slosh damping coefficient of 5 percent is recommended.

Abbott, P.↗

Space Station tethered refueling facility operations

The space-based orbital transfer vehicle will require a large cryogenic fuel storage facility at the Space Station. An alternative to fuel storage onboard the Space Station, is on a tethered orbital refueling facility (TORF) which is separated from the Space Station by a sufficient distance to induce a gravity gradient to settle the propellants. Facility operations are a major concern associated with a tethered LO2/LH2 storage depot. A study was carried out to analyze these operations so as to identify the preferred TORF deployment direction (up or down) and whether the TORF should be permanently or intermittently deployed. The analyses considered safety, contamination, rendezvous, servicing, transportation rate, communication, and viewing. An upwardly, intermittently deployed facility is the preferred configuration for a tethered cryogenic fuel storage.

Kiefel, E. R.↗