Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Lithium electric dipole polarizability

The electric dipole polarizability of the lithium atom in the ground state is calculated including relativistic and quantum electrodynamics corrections. The obtained result {alpha}{sub E}=164.0740(5) a.u. is in good agreement with the less accurate experimental value of 164.19(1.08) a.u. The small uncertainty of about 3 parts per 10{sup 6} comes from the approximate treatment of quantum electrodynamics corrections. Our theoretical result can be considered as a benchmark for more general atomic structure methods and may serve as a reference value for the relative measurement of polarizabilities of the other alkali-metal atoms.

74 ATOMIC AND MOLECULAR PHYSICS↗

Plasma focus ion beam fluence and flux—For various gases

A recent paper derived benchmarks for deuteron beam fluence and flux in a plasma focus (PF) [S. Lee and S. H. Saw, Phys. Plasmas 19, 112703 (2012)]. In the present work we start from first principles, derive the flux equation of the ion beam of any gas; link to the Lee Model code and hence compute the ion beam properties of the PF. The results show that, for a given PF, the fluence, flux, ion number and ion current decrease from the lightest to the heaviest gas except for trend-breaking higher values for Ar fluence and flux. The energy fluence, energy flux, power flow, and damage factors are relatively constant from H{sub 2} to N{sub 2} but increase for Ne, Ar, Kr and Xe due to radiative cooling and collapse effects. This paper provides much needed benchmark reference values and scaling trends for ion beams of a PF operated in any gas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-approach assessment of the spatial distribution of the specific yield: application to the Crau plain aquifer, France

Spatially distributed values of the specific yield, a fundamental parameter for transient groundwater mass balance calculations, were obtained by means of three independent methods for the Crau plain, France. In contrast to its traditional use to assess recharge based on a given specific yield, the water-table fluctuation (WTF) method, applied using major recharging events, gave a first set of reference values. Then, large infiltration processes recorded by monitored boreholes and caused by major precipitation events were interpreted in terms of specific yield by means of a one-dimensional vertical numerical model solving Richards’ equations within the unsaturated zone. Finally, two gravity field campaigns, at low and high piezometric levels, were carried out to assess the groundwater mass variation and thus alternative specific yield values. The range obtained by the WTF method for this aquifer made of alluvial detrital material was 2.9– 26%, in line with the scarce data available so far. The average spatial value of specific yield by the WTF method (9.1%) is consistent with the aquifer scale value from the hydro-gravimetric approach. In this investigation, an estimate of the hitherto unknown spatial distribution of the specific yield over the Crau plain was obtained using the most reliable method (the WTF method). A groundwater mass balance calculation over the domain using this distribution yielded similar results to an independent quantification based on a stable isotope-mixing model. This agreement reinforces the relevance of such estimates, which can be used to build a more accurate transient hydrogeological model.

58 GEOSCIENCES↗

Vertical detachment energies of ammonia cluster anions using self-interaction-corrected methods

Systems with weakly bound extra electrons impose great challenges to semilocal density functional approximations (DFAs), which suffer from self-interaction errors. Small ammonia clusters are one such example of weakly bound anions where the extra electron is weakly bound. We applied two self-interaction correction (SIC) schemes, viz., the well-known Perdew–Zunger and the recently developed locally scaled SIC (LSIC) with the local spin density approximation (LSDA), Perdew–Burke–Ernzerhof (PBE) generalized gradient approximation (GGA), and the SCAN meta-GGA functionals to calculate the vertical detachment energies (VDEs) of small ammonia cluster anions (NH3)n–. Our results show that the LSIC significantly reduces the errors in calculations of VDE with LSDA and PBE-GGA functionals leading to better agreement with the reference values calculated with coupled cluster singles and doubles with perturbative triples [CCSD(T)]. Accurate prediction of VDE as an absolute of the highest occupied molecular orbital (HOMO) is challenging for DFAs. Our results show that VDEs estimated from the negative of HOMO eigenvalues with the LSIC-LSDA and Perdew–Zunger SIC-PBE are within 11 meV of the reference CCSD(T) results. Here, the LSIC method performs consistently well for the VDE estimates, from both the total energy differences and the absolute HOMO eigenvalues.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measuring Rotation and Manure Effects in an Iowa Farm Soil Health Assessment

Core Ideas Farms with known management histories contribute to soil health research. Rotation‐based systems may increase soil organic carbon when combined with appropriate tillage. Inherent soil properties must be considered in soil health assessments. Rotation effects were more noticeable than manure effects on soil health groupings. Data from on‐farm sites with known management histories are needed to quantify soil biological, chemical, and physical properties influencing carbon stocks and soil health. Surface (0–15 cm) and deep core (0–122 cm) soil samples were collected from fields under two rotations in Boone County, IA. The first was a 5‐yr corn [ Zea mays (L.)], soybean [ Glycine max (L.) Merr.], corn, oat [ Avena sativa (L.)], and alfalfa [ Medicago sativa (L.)] rotation to which 0, 18, or 36 Mg ha −1 of a manure/biosolids mixture was applied prior to planting corn. The second was an 8‐yr rotation with 6 yr of mixed grass and legume pasture followed by corn and an oat crop within which the pasture mixture was reestablished. Soil samples were collected evenly across the predominant soil map units (SMUs). Bulk density (BD), soil organic C (SOC), water‐stable aggregates (WSA), microbial biomass carbon (MBC), pH, Mehlich‐3 and diethylenetriaminepentaacetic acid (DTPA) extractable nutrients, electrical conductivity (EC), and nitrogen (total‐, NH 4 –, and NO 3 –N) were measured. Surface SOC data were consistent with Soil Survey values for the various SMUs. Crop rotation effects were more noticeable than manure/biosolid application rate effects. Data from this study were combined with previously published SOC data in Iowa. Results suggest extended rotation systems or those with cover crops may increase SOC 8 ± 4 g kg −1 compared to corn–soybean rotations (33 vs. 25 g kg −1 ). This study provides on‐farm reference values for soil health assessment tools and draws attention to the importance of inherent soil properties for these assessments.

54 ENVIRONMENTAL SCIENCES↗

Nuclear data uncertainty propagation and modeling uncertainty impact evaluation in neutronics core simulation

Uncertainty analysis is a critical requirement in reactor simulation as it is used to quantify the reliability of best-estimate calculation. A comprehensive uncertainty analysis should characterize all sources of uncertainties in a computationally-feasible and scientifically-defendable manner. Here we employ a well-established reduced order modeling (ROM) based uncertainty quantification methodology to propagate uncertainties throughout neutronic calculations. ROM relies on recent advances in randomized data mining techniques applied to large data streams. In our proposed implementation, the nuclear data uncertainties are first propagated from multi-group level through lattice physics calculation to generate few-group parameter uncertainties, described using a vector of mean values and a covariance matrix. Employing an ROM-based compression of the covariance matrix, the few-group uncertainties are then propagated through downstream core simulation in a computationally efficient manner. This straightforward approach, albeit efficient as compared to brute force forward and/or adjoint-based methods, often employs a number of assumptions that have been unquestioned in the literature of neutronic uncertainty analysis. This manuscript argues that these assumptions could introduce another source of uncertainty referred to as modeling uncertainties, whose magnitude needs to be quantified in tandem with nuclear data uncertainties. Thus, our primary goal is to explore the interactions between these two uncertainty sources in order to assess whether modeling uncertainties have an impact on parameter uncertainties. To explore this endeavor, the impact of a number of modeling assumptions on core attributes uncertainties is quantified. The study employs a CANDU reactor model, with Serpent and NEWT as lattice physics solvers and NESTLE-C as core simulator. The modeling assumptions investigated include those related with the uncertainty propagation method employed, e.g., deterministic vs. stochastic, the few-group energy structure employed to represent the cross-sections, the resonance treatment in lattice physics calculation, the reference values for the cross-section, and the number of samples employed to render ROM compression. Results indicate that some of the modeling assumptions could have a non-negligible impact on the core responses propagated uncertainties, highlighting the need for a more comprehensive approach to combine parameter and modeling uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

How Accurate Is Density Functional Theory at Predicting Dipole Moments? An Assessment Using a New Database of 200 Benchmark Values

We present that dipole moments are a simple, global measure of the accuracy of the electron density of a polar molecule. Dipole moments also affect the interactions of a molecule with other molecules as well as electric fields. To directly assess the accuracy of modern density functionals for calculating dipole moments, we have developed a database of 200 benchmark dipole moments, using coupled cluster theory through triple excitations, extrapolated to the complete basis set limit. This new database is used to assess the performance of 88 popular or recently developed density functionals. The results suggest that double hybrid functionals perform the best, yielding dipole moments within about 3.6-4.5% regularized RMS error versus the reference values - which is not very different from the 4% regularized RMS error produced by coupled cluster singles and doubles. Many hybrid functionals also perform quite well, generating regularized RMS errors in the 5-6% range. Lastly, some functionals, however, exhibit large outliers, and local functionals in general perform less well than hybrids or double hybrids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of the effect of local atomic polarization on field-enhanced ion transport in insulating binary oxides: The case of CeO 2

Over the course of more than 70 years, several theoretical models for electric field-enhanced ion diffusion in crystalline insulators have been presented. However, there is no assessment of the validity of these models despite the urge to have a correct description of field-enhanced ion diffusion in several emerging technologies. Herein, an assessment of five models was carried out by computing the field-dependent migration enthalpy ΔH mig (E) for the oxide ion in CeO 2 . The input to these models is the zero-field and zero-temperature migration pathway and/or the activation barrier obtained from an interatomic potential. ΔH mig (E) from these models was compared with reference values obtained from a set of classical molecular-dynamics simulations in the temperature range of 1000 ≤ T ≤ 1600 K and the electric field range of 0 ≤ E ≤ 30 MV/cm. It is revealed that the most successful theoretical models are those that consider local polarization effects induced in the diffusing ion itself and its vicinity. However, all the models did not account for the effect of the electric field and finite temperature on the local polarization, leading to discrepancies between the predicted and the reference ΔH mig (E), particularly at high fields. By comparing results from a rigid-ion potential and a polarizable core-shell potential, it is concluded that an intraionic polarization degree of freedom in the polarizable potential is an important factor in predicting ΔH mig (E), regardless of the field-enhanced diffusion model particularly for low to moderate field. Finally, future more accurate treatments should consider the field- and temperature-dependent interionic and intraionic local polarization effects.

36 MATERIALS SCIENCE↗

Precipitable Water Vapor Characterization In The Gulf Of Cadiz Region (Southwestern Spain) Based On Sun Photometer, GPS And Radiosonde Data

Column integrated water vapor (IWV) data in the Gulf of Cádiz area (Southwestern Spain) are analyzed during the period 2001 to 2005 with two aims: 1) to establish the climatology over this area using three different techniques, such as Sun-Photometer (SP), Global Position System (GPS) and Radiosondes, and 2) to take advantage of this comparative process to assess the quality of radiometric IWV data collected at the RIMA-AERONET station. The 5 years of climatological series gives a mean value of about 2 cm (STD=0.72) and a clear seasonal behavior as a general feature, with the highest values in summer and the lowest in winter. In the multi-annual monthly means basis, the highest values are reached in August-September, with a mean value of 2.5-2.6 cm, whereas the lowest are obtained in January-February, with an average of 1.4-24 1.5. However the most relevant results for this area is the observed local minimum in July, occurring during the maximum of desert dust intrusions in the southern Iberian Peninsula. A comparison process allows us to evaluate the agreement of IWV data sets between these three different techniques at different temporal scales because of different time sampling. On a daily basis and taking GPS as the reference value we have a bias or difference between Radiosonde and GPS measurements for the entire data base of 0.07 cm (relative bias of 3%) and RMSE of 0.33. For SP-GPS we have a bias of 0.14 cm (about 7%) and RMSE of 0.37. On a monthly basis the differences between Radiosonde and GPS values varies from summer with 2% to winter with -8% and between SP and GPS values from 3% in summer to -14% in winter. The observed bias between GPS and SP varies during each SP operational period, with lower values at the beginning of the measurements and increasing until the end of its measurement term and with the bias values being quite dependent on each individual SP. The observed differences highlight the importance of drift in each Sun-Photometer, because of filter aging or other calibration problems. Hence the comparison with GPS appears to be a powerful tool to assess the quality of Sun-Photometer for IWV retrieval.

54 ENVIRONMENTAL SCIENCES↗

SU-D-BRD-03: Improving Plan Quality with Automation of Treatment Plan Checks

Purpose: To evaluate the effectiveness of an automated plan check tool to improve first-time plan quality as well as standardize and document performance of physics plan checks. Methods: The Plan Checker Tool (PCT) uses the Eclipse Scripting API to check and compare data from the treatment planning system (TPS) and treatment management system (TMS). PCT was created to improve first-time plan quality, reduce patient delays, increase efficiency of our electronic workflow, and to standardize and partially automate plan checks in the TPS. A framework was developed which can be configured with different reference values and types of checks. One example is the prescribed dose check where PCT flags the user when the planned dose and the prescribed dose disagree. PCT includes a comprehensive checklist of automated and manual checks that are documented when performed by the user. A PDF report is created and automatically uploaded into the TMS. Prior to and during PCT development, errors caught during plan checks and also patient delays were tracked in order to prioritize which checks should be automated. The most common and significant errors were determined. Results: Nineteen of 33 checklist items were automated with data extracted with the PCT. These include checks for prescription, reference point and machine scheduling errors which are three of the top six causes of patient delays related to physics and dosimetry. Since the clinical roll-out, no delays have been due to errors that are automatically flagged by the PCT. Development continues to automate the remaining checks. Conclusion: With PCT, 57% of the physics plan checklist has been partially or fully automated. Treatment delays have declined since release of the PCT for clinical use. By tracking delays and errors, we have been able to measure the effectiveness of automating checks and are using this information to prioritize future development. This project was supported in part by P01CA059827.

60 APPLIED LIFE SCIENCES↗

SU-F-P-51: Similarity Analysis of the Linear Accelerator Machines Based On Clinical Simulation

Purpose: To evaluate the clinical rationale for Truebeam and Trilogy Linac machines from Varian Medical System as exchangeable treatment modalities in the same radiation oncology department. Methods: Intensity Modulated Radiotherapy (IMRT) plans for different diseases were selected for this study. These disease sites included brain, head and neck, breast, lung, and prostate. The parameters selected for this study were the energy amount, Monitor Unit (MU); dose coverage of target reflected by prescription isodose volume(PIV); dose spillage described by the volume of 50% isodoseline of the prescription; and dose homogeneities represented by the maximum dose (MaxD) and the minimum dose (MinD) of target volume (TV) and critical structure (CS). Each percentage difference between the values of these parameters formed an element of a matrix, which was called Similarity Comparison Matrix(SCM). The elements of the SCM were then simplified by dimensional conversion algorithm, which was used to determine clinical similarity between two machines through a single value. Results: For the selected clinical cases in this study, the average percentage differences between Trilogy and Truebeam in MU was 0.28% with standard deviation(SD) 0.66%, PIV was 0.23% with SD 0.20%, Volume at 50% prescription dose was 0.31% with SD at 0.78%, MaxD at TV is 0.26% with SD 0.35%, MinD at TV is −0.04% with SD 0.51%, MaxD in CS is −0.53% with SD 0.92%, and MinD in CS 3.31%, with SD at 2.89%. The sum, product, geometric and harmonic mean for the matrix elements were 19.0%, 0.00%, 0.19%, and 0.00%. Conclusion: A method to compare two machines in clinical level was developed and some reference values were calculated for decision-making in clinical practice, and this strategy could be expanded to different clinical applications.

60 APPLIED LIFE SCIENCES↗

Evaluation of gold and silver leaching from printed circuit board of cellphones

Highlights: • Printed circuit boards (PCB) of mobile phones have large amounts of metals with high economic value such as gold and silver. • Dissolution of gold was done with a cyanide-based reagent and silver with nitric acid. • Leaching of PCB with Na{sub 2}S{sub 2}O{sub 3} and (NH{sub 4}){sub 2}S{sub 2}O{sub 3} to examine the feasibility of using these reagents was done. - Abstract: Electronic waste has been increasing proportionally with the technology. So, nowadays, it is necessary to consider the useful life, recycling, and final disposal of these equipment. Metals, such as Au, Ag, Cu, Sn and Ni can be found in the printed circuit boards (PCB). According to this, the aims of this work is to characterize the PCBs of mobile phones with aqua regia; obtaining “reference” values of leaching, to gold and silver, with cyanide and nitric acid, respectively; and study the process of leaching of these metals in alternative leaching with sodium thiosulfate and ammonium thiosulfate. The metals were characterized by digesting the sample with aqua regia for 1 and 2 h at 60 °C and 80 °C. The leaching of Au with a commercial reagent (cyanide) and the Ag with HNO{sub 3}were made. The leaching of Au and Ag with alternative reagents: Na{sub 2}S{sub 2}O{sub 3,} and (NH{sub 4}){sub 2}S{sub 2}O{sub 3} in 0.1 M concentration with the addition of CuSO{sub 4}, NH{sub 4}OH, and H{sub 2}O{sub 2}, was also studied. The results show that the digestion with aqua regia was efficient to characterize the metals present in the PCBs of mobile phones. However, the best method to solubilize silver was by digesting the sample with nitric acid. The leaching process using sodium thiosulfate was more efficient when an additional concentration of 0.015 and 0.030 M of the CuSO{sub 4} was added.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Proficiency Tests for Environmental Radioactivity Measurement Organized by an Accredited Laboratory

For 40 years, STEME (Environmental Sample Processing and Metrology Department) organized international proficiency testing (PT) exercises formerly for WHO (World Health Organization) and EC (European Community) and currently for ASN (French Nuclear Safety Authority). Five PT exercises are organized each year for the measurement of radionuclides (alpha, beta and gamma) in different matrixes (water, soil, biological and air samples) at environmental levels. ASN can deliver a French ministerial agreement to participate on environmental radioactivity measurements French network for laboratories asking it. Since 2006, November, STEME is the first French entity obtaining a COFRAC (French Committee of Accreditation) accreditation as 'Interlaboratory Comparisons' for the organization of proficiency tests for environmental radioactivity measurement according to standard International Standard Organization (ISO) 17025 and guide ISO 43-1. STEME has in charge to find, as far as possible, real sample or to create, by radionuclide adding, an adapted sample. STEME realizes the sampling, the samples preparation and the dispatching. STEME is also accredited according to Standard 17025 for radioactivity measurements in environmental samples and determines homogeneity, stability and reference values. After the reception of participating laboratories results, STEME executes statistical treatments in order to verify the normal distribution, to eliminate outliers and to evaluate laboratories performance.Laboratories participate with several objectives, to obtain French agreement, to prove the quality of their analytical performance in regards to standard 17025 or to validate new methods or latest developments. For 2 years, in addition to usual PT exercises, new PT about alpha or beta measurement in air filters, radioactive iodine in carbon cartridges or measurement of environmental dosimeters are organized. These PT exercises help laboratories to improve radioactive measurements and to rectify old mistakes. The PT exercises organized by STEME are becoming essential for French and some European laboratories working in radioactive measurements.The STEME organization, in respect of accreditation references, is presented.

54 ENVIRONMENTAL SCIENCES↗

Oral Reference Dose for ethylene glycol based on oxalate crystal-induced renal tubule degeneration as the critical effect

Several risk assessments have been conducted for ethylene glycol (EG). These assessments identified the kidney as the primary target organ for chronic effects. None of these assessments have incorporated the robust database of species-specific toxicokinetic and toxicodynamic studies with EG and its metabolites in defining uncertainty factors used in reference value derivation. Pertinent in vitro and in vivo studies related to one of these metabolites, calcium oxalate, and its role in crystal-induced nephropathy are summarized, and the weight of evidence to establish the mode of action for renal toxicity is reviewed. Previous risk assessments were based on chronic rat studies using a strain of rat that was later determined to be less sensitive to the toxic effects of EG. A recently published 12-month rat study using the more sensitive strain (Wistar) was selected to determine the point of departure for a new risk assessment. This approach incorporated toxicokinetic and toxicodynamic data and used Benchmark Dose methods to calculate a Human Equivalent Dose. Uncertainty factors were chosen, depending on the quality of the studies available, the extent of the database, and scientific judgment. The Reference Dose for long-term repeat oral exposure to EG was determined to be 15 mg/kg bw/d.

Snellings, William M.↗

Electronic excitations and spin interactions in chromium trihalides from embedded many-body wavefunctions

Although chromium trihalides are widely regarded as a promising class of two-dimensional magnets for next-generation devices, an accurate description of their electronic structure and magnetic interactions has proven challenging to achieve. Here, we quantify electronic excitations and spin interactions in CrX 3 (X = Cl, Br, I) using embedded many-body wavefunction calculations and fully generalized spin Hamiltonians. We find that the three trihalides feature comparable d-shell excitations, consisting of a high-spin 4 A 2 ($t^3_{2g}$$e^0_g$) ground state lying 1.5–1.7 eV below the first excited state 4 T 2 ($t^2_{2g}$$e^1_g$). CrCl 3 exhibits a single-ion anisotropy A sia = - 0.02 meV, while the Cr spin-3/2 moments are ferromagnetically coupled through bilinear and biquadratic exchange interactions of J 1 = - 0.97 meV and J 2 = - 0.05 meV, respectively. The corresponding values for CrBr 3 and CrI 3 increase to A sia = -0.08 meV and A sia = - 0.12 meV for the single-ion anisotropy, J 1 = -1.21 meV, J 2 = -0.05 meV and J 1 = -1.38 meV, J 2 = -0.06 meV for the exchange couplings, respectively. We find that the overall magnetic anisotropy is defined by the interplay between A sia and A dip due to magnetic dipole–dipole interaction that favors in-plane orientation of magnetic moments in ferromagnetic monolayers and bulk layered magnets. The competition between the two contributions sets CrCl 3 and CrI 3 as the easy-plane (A sia + A dip >0) and easy-axis (A sia + A dip <0) ferromagnets, respectively. The differences between the magnets trace back to the atomic radii of the halogen ligands and the magnitude of spin–orbit coupling. Our findings are in excellent agreement with recent experiments, thus providing reference values for the fundamental interactions in chromium trihalides.

36 MATERIALS SCIENCE↗

Atomization energies from coupled-cluster calculations augmented with explicitly-correlated perturbation theory.

The atomization energies of the 105 molecules in the test set of Bakowies [D. Bakowies, J. Chem. Phys. 127 (2007) 084105] have been computed with an estimated standard deviation (from the values compiled in the Active Thermochemical Tables) of {+-}0.1 kJ/mol per valence electron in the molecule. Equilibrium geometries and harmonic vibrational frequencies were calculated at the all-electron CCSD(T)/cc-pCVTZ level, that is, at the level of coupled-cluster theory with singles, doubles and non-iterative triples in a correlation-consistent polarized core-valence triple-zeta basis. Single-point energy calculations were performed at the all-electron CCSD(T) level in a correlation-consistent polarized core-valence quadruple-zeta basis (cc-pCVQZ), and several corrections were added: (i) a correction for the basis-set truncation error, obtained from second-order perturbation theory using Slater-type geminals (MP2-F12 theory), (ii) a correction for the effect of anharmonicity on the zero-point vibrational energy, (iii) a relativistic correction, (iv) a correction for the difference between the full CCSDT model (coupled-cluster theory with singles, doubles and triples) and the CCSD(T) approximation, and (v) a correction for connected quadruple excitations obtained from CCSDT(Q) calculations. The correction for the basis-set truncation error was obtained from MP2-F12 calculations by scaling the MP2 basis-set truncation error by an empirically optimized 'interference factor' of f{sub int} = 0.78. The reference values from the Active Thermochemical Tables for 73 molecules in the test set, the equilibrium geometries, the harmonic vibrational frequencies, and all of the energy corrections represent valuable data for performance assessments of additivity schemes that will be developed in the future, in which the basis-set truncation error will be calculated at the level of coupled-cluster theory using Slater-type geminals (CC-F12 theory). Such a scheme will be free of empirical corrections and scaling factors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Partial scan artifact reduction (PSAR) for the assessment of cardiac perfusion in dynamic phase-correlated CT

Purpose: Cardiac CT achieves its high temporal resolution by lowering the scan range from 2{pi} to {pi} plus fan angle (partial scan). This, however, introduces CT-value variations, depending on the angular position of the {pi} range. These partial scan artifacts are of the order of a few HU and prevent the quantitative evaluation of perfusion measurements. The authors present the new algorithm partial scan artifact reduction (PSAR) that corrects a dynamic phase-correlated scan without a priori information. Methods: In general, a full scan does not suffer from partial scan artifacts since all projections in [0, 2{pi}] contribute to the data. To maintain the optimum temporal resolution and the phase correlation, PSAR creates an artificial full scan p{sub n}{sup AF} by projectionwise averaging a set of neighboring partial scans p{sub n}{sup P} from the same perfusion examination (typically N{approx_equal}30 phase-correlated partial scans distributed over 20 s and n=1,...,N). Corresponding to the angular range of each partial scan, the authors extract virtual partial scans p{sub n}{sup V} from the artificial full scan p{sub n}{sup AF}. A standard reconstruction yields the corresponding images f{sub n}{sup P}, f{sub n}{sup AF}, and f{sub n}{sup V}. Subtracting the virtual partial scan image f{sub n}{sup V} from the artificial full scan image f{sub n}{sup AF} yields an artifact image that can be used to correct the original partial scan image: f{sub n}{sup C}=f{sub n}{sup P}-f{sub n}{sup V}+f{sub n}{sup AF}, where f{sub n}{sup C} is the corrected image. Results: The authors evaluated the effects of scattered radiation on the partial scan artifacts using simulated and measured water phantoms and found a strong correlation. The PSAR algorithm has been validated with a simulated semianthropomorphic heart phantom and with measurements of a dynamic biological perfusion phantom. For the stationary phantoms, real full scans have been performed to provide theoretical reference values. The improvement in the root mean square errors between the full and the partial scans with respect to the errors between the full and the corrected scans is up to 54% for the simulations and 90% for the measurements. Conclusions: The phase-correlated data now appear accurate enough for a quantitative analysis of cardiac perfusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First Simulations of Designing Stratospheric Sulfate Aerosol Geoengineering to Meet Multiple Simultaneous Climate Objectives

In this work, we describe the first simulations of stratospheric sulfate aerosol geoengineering using multiple injection locations to meet multiple simultaneous surface temperature objectives. Simulations were performed using CESM1(WACCM), a coupled atmosphere-ocean general circulation model with fully interactive stratospheric chemistry, dynamics (including an internally generated quasi-biennial oscillation), and a sophisticated treatment of sulfate aerosol formation, microphysical growth, and deposition. The objectives are defined as maintaining three temperature features at their 2020 levels against a background of the RCP8.5 scenario over the period 2020-2099. These objectives are met using a feedback mechanism in which the rate of sulfur dioxide injection at each of the four locations is adjusted independently every year of simulation. Even in the presence of uncertainties, nonlinearities, and variability, the objectives are met, predominantly by SO2 injection at 30°N and 30°S. By the last year of simulation, the feedback algorithm calls for a total injection rate of 51 Tg SO2 per year. The injections are not in the tropics, which results in a greater degree of linearity of the surface climate response with injection amount than has been found in many previous studies using injection at the equator. Because the objectives are defined in terms of annual mean temperature, the required geeongineering results in "overcooling" during summer and "undercooling" during winter. The hydrological cycle is also suppressed as compared to the reference values corresponding to the year 2020. The demonstration we describe in this study is an important step toward understanding what geoengineering can do and what it cannot do.

54 ENVIRONMENTAL SCIENCES↗