Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

WE-EF-303-08: Proton Radiography Using Pencil Beam Scanning and Novel Micromegas Detectors

Purpose: While the energy of therapeutic proton beams can be adjusted to penetrate to any given depth in water, range uncertainties arise in patients due in part to imprecise knowledge of the stopping power of protons in human tissues. Proton radiography is one approach to reduce the beam range uncertainty, thereby allowing for a reduction in treatment margins and dose escalation. Methods: The authors have adapted a novel detector technology based on Micromesh Gaseous Structure (“Micromegas”) for proton therapy beams and have demonstrated fine spatial and time resolution of magnetically scanned proton pencil beams, as well as wide dynamic range for dosimetry. In this work, proton radiographs were obtained using Micromegas 2D planes positioned downstream of solid water assemblies. The position-sensitive monitor chambers in the IBA proton delivery nozzle provide the beam entrance position. Results: Radiography with Micromegas detectors and actively scanned beams provide spatial resolution of up to 300 µm and water-equivalent thickness (WET) resolution as good as 0.02% (60 µm out of 31 cm total thickness), with the dose delivered to the patient kept below 2 cGy. The spatial resolution as a function of sample rate and number of delivered protons is found to be near the theoretical Cramer-Rao lower bound. Using the CR bound, we argue that the imaging dose could be further lowered to 1 mGy, while still achieving sub-mm spatial resolution, by relatively simple instrumentation upgrades and beam delivery modifications. Conclusion: For proton radiography, high spatial and WET resolution can be achieved, with minimal additional dose to patient, by using magnetically scanned proton pencil beams and Micromegas detectors.

60 APPLIED LIFE SCIENCES↗

Operando X-ray tomography and sub-second radiography for characterizing transport in polymer electrolyte membrane electrolyzer

Utilizing hydrogen gas as an energy carrier and enabling a hydrogen economy is a promising step towards decarbonization. Water electrolysis is a key process in hydrogen generation, but electrolyzers face a couple technological hurdles before widespread integration could occur. Understanding morphology evolution and transport processes in an operating polymer electrolyte membrane (PEM) electrolyzer is key to reducing cost and increasing efficiency. In this study, combined operando X-ray computed tomography and radiography are used to study transport and degradation in PEM electrolyzers subject to applied current densities. Tomography enables three-dimensional steady-state imaging but does not capture transport subtleties. Radiography is limited to two-dimensions but does capture transient phenomena. The tomography results depict degradation of the catalyst layer on the anode side of the electrolyzer. The rate of degradation was observed to increase as the applied current density increased. The catalyst particle detachment is due to autonomous propulsion during the oxygen evolution reaction. Particles that mechanically rip off the membrane were observed to be redeposited into the porous transport layer. During radiography, sub-second exposure time is required to capture the transient behavior of oxygen evolution, even at the lower current densities (50-200 mAcm -2 ). Various flow regimes were observed in the channel ranging from bubbly to slug flow depending on current density. In conclusion, experimental observations agree with a model that an increase in current density increases oxygen bubble diameter and decreases bubble residence time within the electrolyzer channel.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-situ neutron radiography of pore-water movement in portland cement mortar under subzero temperature exposure: Insights from D 2 O-H 2 O systems

Neutron radiography was employed in this study to monitor real-time pore water movement in portland cement mortar exposed to subzero temperatures, providing novel insights into freeze-thaw (F-T) damage mechanisms. Deuterated water (D 2 O) was used to hydrate the cement in the mortar specimens, and the pore structure was saturated with water (H 2 O), allowing for a contrast that enabled detailed tracking of water movement predominantly in the pore structure. Furthermore, the mortar sample was placed on a chiller plate set to subzero temperatures, thereby providing a one-dimensional temperature gradient vertically in the sample. Neutron radiography revealed that unfrozen water migrated upward as the freezing front advanced, which can create hydraulic pressure within the mortar microstructure and may contribute to the initiation and propagation of microcracks during F-T cycles. Additional characterization of the concrete made with D 2 O showed a marked contrast to the samples made with H 2 O, including delayed hydration, diminished compressive strength, and greater porosity. Therefore, while mortar made with D 2 O allowed for greater neutron contrast to the pores filled with H 2 O, further study is required to produce mortars with similar properties to those made with H 2 O. In addition, further refinement is needed to the radiography experiment to allow for greater control of temperatures and potential quantification of the water concentration.

Air-void system↗

Fast-neutron/gamma-ray radiography using a broad-energy neutron source

Transmission radiography is a well-established nondestructive examination technique with widespread application to fields ranging from medicine to security. Traditionally, inspection is performed using a single particle type (such as x-rays). However, the information available using a single probe for traditional radiography is limited. The present work evaluates material discrimination via transmission radiography using the attenuation ratio of monoenergetic gamma rays to a broad spectrum of fast neutrons. Here, the method was assessed using an 241 Am/Be radioisotope source that provides both 4.4 MeV gamma rays and a spectrum of fast neutrons up to 12 MeV. A total of 14 object configurations were measured: seven different materials each with two thicknesses (2.5 cm and 5 cm). The ability to distinguish materials was evaluated and shows more significant variation among atomic numbers than for high-energy x-rays alone, making it easier to distinguish between classes such as low-, mid-, and high-Z materials. These results suggest that superior material discrimination is also possible using a combination of monoenergetic gamma rays and broad-spectrum fast neutrons from a variety of nuclear reactions, such as 11 B(d,nγ) 12 C, that could be implemented in future inspection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Resolution Neutron Radiography and Tomography of Hydrided Zircaloy-4 Cladding Materials

Neutron radiography for hydrogen analysis was performed with several Zircaloy-4 cladding samples with controlled hydrogen concentrations up to 1100 ppm. Hydrogen charging was performed in a process tube that was heated to facilitate hydrogen absorption by the metal. A correlation between the hydrogen concentration in the hydrided tubes and the neutron intensity was established, by which hydrogen content can be determined precisely in a small area (55 m x 55 m). Radiography analysis was also performed to evaluate the heating rate and its correlation with the hydrogen distribution through hydrided materials. In addition to radiography analysis, tomography experiments were performed on Zircaloy-4 tube samples to study the local hydrogen distribution. Through tomography analysis a 3D reconstruction of the tube was evaluated in which an uneven hydrogen distribution in the circumferential direction can be observed.

hydride↗

Applications of neutron radiography for the nuclear power industry

The World Conference on Neutron Radiography (WCNR) and International Topical Meeting on Neutron Radiography (ITMNR) series have been running over 35 years. The most recent event, ITMNR-8, focused on industrial applications and was the first time this series was hosted in China. In China, more than twenty new nuclear power plants are in construction and plans have been announced to increase the nuclear capacity further by a factor of three within fifteen years. There are additional prospects in many other nations. Neutron tests were vital during previous developments of materials and components for nuclear power applications, as reported in this conference series. For example a majority of the 140 papers in the Proceedings of the First WCNR are for the benefit of the nuclear power industry. Included are reviews of the diverse techniques being applied in Europe, Japan, the United States, and at many other centers. Many of those techniques are being utilized and advanced to the present time. Neutron radiography of irradiated nuclear fuel provides more comprehensive information about the internal condition of irradiated nuclear fuel than any other non-destructive technique to date. Applications include examination of nuclear waste, nuclear fuels, cladding, control elements, and other critical components. In this paper, the techniques developed and applied internationally for the nuclear power industry since the earliest years are reviewed, and the question is asked whether neutron test techniques can be of value in development of the present and future generations of nuclear power plants world-wide.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monochromatic x-ray radiography for areal-density measurement of inertial fusion energy fuel in fast ignition experiment

Ultrafast, two-dimensional x-ray imaging is an important diagnostics for the inertial fusion energy research, especially in investigating implosion dynamics at the final stage of the fuel compression. Although x-ray radiography was applied to observing the implosion dynamics, intense x-rays emitted from the high temperature and dense fuel core itself are often superimposed on the radiograph. This problem can be solved by coupling the x-ray radiography with monochromatic x-ray imaging technique. In the experiment, 2.8 or 5.2 keV backlight x-rays emitted from laser-irradiated polyvinyl chloride or vanadium foils were selectively imaged by spherically bent quartz crystals with discriminating the out-of-band emission from the fuel core. This x-ray radiography system achieved 24 {mu}m and 100 ps of spatial and temporal resolutions, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnifying lens for 800 MeV proton radiography

This article describes the design and performance of a magnifying magnetic-lens system designed, built, and commissioned at the Los Alamos National Laboratory (LANL) for 800 MeV flash proton radiography. The technique of flash proton radiography has been developed at LANL to study material properties under dynamic loading conditions through the analysis of time sequences of proton radiographs. The requirements of this growing experimental program have resulted in the need for improvements in spatial radiographic resolution. To meet these needs, a new magnetic lens system, consisting of four permanent magnet quadrupoles, has been developed. This new lens system was designed to reduce the second order chromatic aberrations, the dominant source of image blur in 800 MeV proton radiography, as well as magnifying the image to reduce the blur contribution from the detector and camera systems. The recently commissioned lens system performed as designed, providing nearly a factor of three improvement in radiographic resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Source characterization and modeling development for monoenergetic-proton radiography experiments on OMEGA

A monoenergetic proton source has been characterized and a modeling tool developed for proton radiography experiments at the OMEGA [T. R. Boehly et al., Opt. Comm. 133, 495 (1997)] laser facility. Multiple diagnostics were fielded to measure global isotropy levels in proton fluence and images of the proton source itself provided information on local uniformity relevant to proton radiography experiments. Global fluence uniformity was assessed by multiple yield diagnostics and deviations were calculated to be {approx}16% and {approx}26% of the mean for DD and D{sup 3}He fusion protons, respectively. From individual fluence images, it was found that the angular frequencies of Greater-Than-Or-Equivalent-To 50 rad{sup -1} contributed less than a few percent to local nonuniformity levels. A model was constructed using the Geant4 [S. Agostinelli et al., Nuc. Inst. Meth. A 506, 250 (2003)] framework to simulate proton radiography experiments. The simulation implements realistic source parameters and various target geometries. The model was benchmarked with the radiographs of cold-matter targets to within experimental accuracy. To validate the use of this code, the cold-matter approximation for the scattering of fusion protons in plasma is discussed using a typical laser-foil experiment as an example case. It is shown that an analytic cold-matter approximation is accurate to within Less-Than-Or-Equivalent-To 10% of the analytic plasma model in the example scenario.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Searching early bone metastasis on plain radiography by using digital imaging processing

Some authors mention that it is not possible to detect early bone metastasis on plain radiography. In this work we use digital imaging processing to analyze three radiographs taken from a patient with bone metastasis discomfort on the right shoulder. The time period among the first and second radiography was approximately one month and between the first and the third one year. This procedure is a first approach in order to know if in this particular case it was possible to detect an early bone metastasis. The obtained results suggest that by carrying out a digital processing is possible to detect the metastasis since the radiography contains the information although visually it is not possible to observe it.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Streaked radiography of an irradiated foam sample on the National Ignition Facility

Streaked x-ray radiography images of annular patterns in an evolving tantalum oxide foam under the influence of a driven, subsonic radiation wave were obtained on the National Ignition Facility. This is the first successful radiography measurement of the evolution of well-defined foam features under a driven, subsonic wave in the diffusive regime. A continuous record of the evolution was recorded on an x-ray streak camera, using a slot-apertured point-projection backlighter with an 8 ns nickel source (7.9 keV). Radiography images were obtained for four different annular patterns, which were corrected using a source-dependent flat-field image. The evolution of the foam features was well-modeled using the 3D KULL radiation hydrodynamics code. This experimental and modeling platform can be modified for scaled high-energy-density laboratory astrophysics experiments.

36 MATERIALS SCIENCE↗

Accelerator driven gamma and fast neutron radiography test-bed at Lawrence Livermore National Laboratory

Accelerator driven fusion gammas and fast neutrons could provide unique radiography capabilities due to their ability to produce both high and low energy mono-energetic gammas and neutrons compared with broadband bremsstrahlung based x-ray sources. The possibility of simultaneously obtaining both gamma and neutron radiographs using one source could allow complex objects composed of a large range of low to high Z materials to be imaged. In this paper we review a 4 MV RFQ accelerator driven radiography test-bed at LLNL designed to study the physics involved in applying these dual output fusion reactions for radiography applications. First experimental neutron images from a carbon target are presented.

43 PARTICLE ACCELERATORS↗

Study of pipe thickness loss using a neutron radiography method

The purpose of this preliminary work is to study for thickness changes in objects using neutron radiography. In doing the project, the technique for the radiography was studied. The experiment was done at NUR-2 facility at TRIGA research reactor in Malaysian Nuclear Agency, Malaysia. Test samples of varying materials were used in this project. The samples were radiographed using direct technique. Radiographic images were recorded using Nitrocellulose film. The films obtained were digitized to processed and analyzed. Digital processing is done on the images using software Isee!. The images were processed to produce better image for analysis. The thickness changes in the image were measured to be compared with real thickness of the objects. From the data collected, percentages difference between measured and real thickness are below than 2%. This is considerably very low variation from original values. Therefore, verifying the neutron radiography technique used in this project.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AXIS: An instrument for imaging Compton radiographs using the Advanced Radiography Capability on the NIF

Compton radiography is an important diagnostic for Inertial Confinement Fusion (ICF), as it provides a means to measure the density and asymmetries of the DT fuel in an ICF capsule near the time of peak compression. The AXIS instrument (ARC (Advanced Radiography Capability) X-ray Imaging System) is a gated detector in development for the National Ignition Facility (NIF), and will initially be capable of recording two Compton radiographs during a single NIF shot. The principal reason for the development of AXIS is the requirement for significantly improved detection quantum efficiency (DQE) at high x-ray energies. AXIS will be the detector for Compton radiography driven by the ARC laser, which will be used to produce Bremsstrahlung X-ray backlighter sources over the range of 50 keV–200 keV for this purpose. It is expected that AXIS will be capable of recording these high-energy x-rays with a DQE several times greater than other X-ray cameras at NIF, as well as providing a much larger field of view of the imploded capsule. AXIS will therefore provide an image with larger signal-to-noise that will allow the density and distribution of the compressed DT fuel to be measured with significantly greater accuracy as ICF experiments are tuned for ignition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Food consumption and digestion time estimation of spotted scat, Scatophagus argus, using X-radiography technique

The present study was conducted to investigate the food consumption pattern and gastric emptying time using x-radiography technique in scats fish, Scatophagus argus feeding to satiation in laboratory conditions. Prior to feeding experiment, fish of various sizes were examined their stomach volume, using freshly prepared stomachs ligatured at the tips of the burret, where the maximum amount of distilled water collected in the stomach were measured (ml). Stomach volume is correlated with maximum food intake (S{sub max}) and it can estimate the maximum stomach distension by allometric model i.e volume=0.0000089W{sup 2.93}. Gastric emptying time was estimated using a qualitative X-radiography technique, where the fish of various sizes were fed to satiation at different time since feeding. All the experimental fish was feed into satiation using radio-opaque barium sulphate (BaSO{sub 4}) paste injected in the wet shrimp in proportion to the body weight. The BaSO{sub 4} was found suitable to track the movement of feed/prey in the stomach over time and gastric emptying time of scats fish can be estimated. The results of qualitative X-Radiography observation of gastric motility, showed the fish (200 gm) that fed to maximum satiation meal (circa 11 gm) completely emptied their stomach within 30 - 36 hrs. The results of the present study will provide the first baseline information on the stomach volume, gastric emptying of scats fish in captivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MPRAD: A Monte Carlo and ray-tracing code for the proton radiography in high-energy-density plasma experiments

Proton radiography is used in various high-energy-density (HED) plasma experiments. In this paper, we describe a Monte Carlo and raytracing simulation tool called multimegaelectronvolt proton radiography (MPRAD) that can be used for modeling the deflection of proton beams in arbitrary three dimensional electromagnetic fields as well as the diffusion of the proton beams by Coulomb scattering and stopping power. Specifically, the Coulomb scattering and stopping power models in cold matter and fully ionized plasma are combined using interpolation. We discuss the application of MPRAD in a few setups relevant to HED plasma experiments where the plasma density can play a role in diffusing the proton beams and affecting the prediction and interpretation of the proton images. It is shown how the diffusion due to plasma density can affect the resolution and dynamical range of the proton radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-radiography of imploded shells on OMEGA based on additive-free multi-monochromatic continuum spectral analysis

Radiographs of pure-DT cryogenic imploding shells provide critical validation of progress toward ignition-scalable performance of inertial confinement fusion implosions. Cryogenic implosions on the OMEGA Laser System can be self-radiographed by their own core spectral emission near ≈2 keV. Utilizing the distinct spectral dependences of continuum emissivity and opacity, the projected optical-thickness distribution of imploded shells, i.e., the shell radiograph, can be distinguished from the structure of the core emission distribution in images.Importantly, this can be done without relying on spectral additives (shell dopants), as in previous applications of implosion self-radiography. Furthermore, demonstrations with simulated data show that this technique is remarkably well-suited to cryogenic implosions and can also be applied to self-radiography of imploded room-temperature CH shells at higher spectral energy (hv ≈ 3–5 keV) based on the very similar continuum spectrum of carbon. Experimental demonstration of additive-free self-radiography with warm CH shell implosions on OMEGA will provide an important proof of principle for future applications to cryogenic DT implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cosmic ray radiography of a human phantom

Cosmic ray muons that reach the earth's surface provide a natural source of radiation that is used for radiography. In this paper, we show that radiography using the cosmic radiation background provides a method that can be used to monitor bulk aspects of human anatomy. We describe a method that can be used to measure changes in patients as a function of time by cosmic ray muon radiography. Modeling shows muon tomography could provide hourly readouts of parameters such as lung density with sufficient sensitivity to detect the time changes in the inflammation of the lungs in, e.g., COVID patients.

60 APPLIED LIFE SCIENCES↗