Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

High Power Solid Target for Positron Source at CEBAF

The progress in the development of a polarized positron injector for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is presented. The polarized positron beam is generated by a high current polarized electron beam (>1 mA @ 120 MeV) via bremsstrahlung radiation and e+e- pair production in the tungsten target. The simulations show that using an optimized target and positron beamline, the positron injector can provide a cw positron beam with a current larger than 50 nA and a polarization as large as 60%. Injected into the North Linac of CEBAF at an energy of 123 MeV, the positron beam can reach a maximum energy of 12 GeV to perform a rich experimental program. The results of the thermal and structural FEA analysis of the heat load in the target are presented, as well as the simulation results of radiation damage in the target. The performed and planned target material fatigue and radiation damage tests are discussed. This work is supported by the U.S. DOE, Office of Science, Office of Nuclear Physics, Contract No. DE-AC05-06OR23177 and the European Union?s Horizon 2020 research and innovation program under grant agreement No. 824093.

Ushakov, Andriy↗

TTDAQ: A Continuous Flow, Timing and Trigger DAQ System

Final Scientific/Technical Report for DOE Award DE-SC0019581, “TTDAQ: A Continuous Flow, Timing and Trigger DAQ System.” The report summarizes Telluric Labs’ Phase II STTR work developing silicon-photonic building blocks for a software-defined, continuous-flow, trigger-less data acquisition system for next-generation high-energy and nuclear-physics detectors. The project focused on radiation-hard photonic integrated circuits, remote optical illumination, dense wavelength-division multiplexing, and a differential microring-resonator transceiver architecture designed to improve high-speed optical link stability and bandwidth. The report describes project objectives, technical accomplishments, AIM Photonics tape-outs, bench characterization, radiation-hardness testing, deferred integration work, and potential applications beyond physics readout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radial radio frequency (RF) electron guns

Radial radio frequency (RF) electron guns and radial RF electron gun systems are provided that are capable of generating an electron beam that can propagate either radially inward, towards the axis of a cylinder, or radially outward from the axis. A beam source capable of generating a radially inwardly propagating electron beam, while perhaps not particularly useful as a source for a higher-energy accelerator, offers potential advantages for materials processing, as the geometry allows irradiation from all sides of an enclosed material flow with a single structure. Other potential applications include, but are not limited to, atmospheric plasma generation, radiation damage testing, and possibly, novel electron lens-type devices for hadron accelerators.

Lewellen, John↗

Evaluation of Oak Ridge National Laboratory Health Physics Research Reactor Operation Data for Critical Benchmark Creation [Abstract]

The Oak Ridge National Laboratory (ORNL) Health Physics Research Reactor (HPRR) was a research reactor designed and built at ORNL in 1961. The critical assembly was using a highly enriched uranium and molybdenum alloy as the fuel, and it could be operated in steady-state or burst modes. The reactor was used for about 25 years to produce a lot of publications related to dosimetry, radiobiology and radiation detectors testing before its decommissioning in 1987. In recent years, the idea of using legacy operation data from the to create a valuable critical accident alarm system shielding benchmark arose. Such a benchmark has been submitted to the International Criticality Safety Benchmark Experiment Project (ICSBEP) Technical Review Group for a potential inclusion in the 2022 version of the handbook. Another way to use the valuable data from the operation of the HPRR is to evaluate the feasibility of the creation of a subcritical or prompt supercritical benchmark for inclusion in the ICSBEP or the International Reactor Physics Experiments Evaluation Project (IRPhEP) handbooks. To initiate a burst, the HPRR had to be operated in a slightly subcritical state for a few minutes. Then, the insertion of the burst control rod would greatly increase the reactivity of the system and start the burst. No critical configuration of the HPRR critical assembly could be located. The only information available concerns stable subcritical and prompt supercritical states, found in a burst experiments’ logbook. In the recovered logbook pages, information about 8 different bursts is available. The information includes the rods positions before and during a burst, the recorded subcritical reactor period and reactivity, and the burst fission yield derived from the temperature elevation sulfur pellet irradiation analysis. By using the HPRR logbook information and the as-built drawings of the critical assembly, a highly detailed model of the HPRR was created with SCALE 6.2.4/KENO-VI. Eight KENO-VI models were created to replicate the sub-critical assembly configurations described in the eight bursts from the recovered logbook pages. KENO-VI calculates k eff and it can be linked to a reactivity value in cents by using the delayed neutron fraction B eff , also calculated by KENO-VI. KENO-VI can also be used to model the prompt super-critical configurations of the HPRR and to assess the similarity with the burst measurements by comparing the calculated k eff and the measured fission yields between each burst. Unfortunately, high uncertainty exist and the obtained discrepancies between experiments and calculation results are high, compromising the creation of a valuable critical benchmark from HPRR operation data. The reasons of the discrepancies and potential ways to solve them are explored.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fundamental Phenomena and Applications of Swift Heavy Ion Irradiations

This review concentrates on the specific properties and characteristics of damage structures generated with high-energy ions in the electronic energy loss regime. Irradiation experiments with so-called swift heavy ions (SHIs) find applications in many different fields, with examples presented in ion-track nanotechnology, radiation hardness analysis of functional materials, and laboratory tests of cosmic radiation. The basics of the SHI-solid interaction are described with special attention to processes in the electronic subsystem. The broad spectrum of damage phenomena is exemplified for various materials and material classes, along with a description of typical characterization techniques. This review also presents state-of-the-art modeling efforts that try to account for the complexity of the coupled processes of the electronic and atomic subsystems. Lastly, a brief discussion at the end of this review on SHI phenomena induced by fission fragments in nuclear materials will highlight the relevance of energetic ion irradiation in nuclear technology applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scenario optimization for the tokamak ramp-down phase in RAPTOR: Part A. Analysis and model validation on ASDEX Upgrade

We discuss how the combination of experimental observations and rapid modeling has enabled to improve understanding of the tokamak ramp-down phase in ASDEX Upgrade. A series of dedicated experiments has been performed, to disentangle the effect of individual actuators like plasma current, auxiliary heating and plasma shaping. Optimized discharge termination strategies with increased margin with respect to radiative and vertical stability limits are proposed and tested in experiment. Radiative collapse of the edge $T$ $e$ profile after the HL back-transition is avoided by initially maintaining auxiliary heating during L-mode, showing beneficial effects even after the auxiliary heating is turned off. The capability of the RAPTOR code to model the time evolution of the internal inductance $\ell$ $i3$ has been validated, including the effect of a change in the $I$ $p$ ramp-down rate and the HL transition timing. The reduction of $\ell$ $i3$ caused by rapid compression of the plasma cross-section has been quantitatively recovered in simulations. Successful modeling of the $\ell$ $i3$ time evolution is essential to optimize ramp-down scenarios for future fusion reactors, for which vertical stability and power balance control will be more challenging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam Test Results of the RADiCAL—A Radiation Hard Innovative EM Calorimeter

High-performance calorimetry conducted at future hadron colliders, such as the FCC-hh, poses a significant challenge for applying current detector technologies due to unprecedented beam luminosities and radiation fields. Solutions include developing scintillators that are capable of separating events at the sub-fifty picosecond level while also maintaining performance after extreme and constant neutron and ionizing radiation exposure. The radiation-hard innovative calorimeter (RADiCAL) is an approach that incorporates radiation tolerant materials in a sampling “shashlik”-style calorimeter configuration, using quartz capillaries filled with organic liquid or polymer-based wavelength shifters embedded in layers of tungsten plates and lutetium-yttrium oxyorthosilicate (LYSO) crystals. Here, this novel design intends to address the priority research directions (PRD) for calorimetry listed in the DOE basic research needs (BRN) workshop for high energy physics (HEP) instrumentation. Here we report preliminary results from an experimental run at the Fermilab Test Beam Facility (FTBF) in June 2022. These tests demonstrate that the RADiCAL concept is capable of ¡50 ps timing resolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Neutrino-Induced Neutral Current Delta Radiative Decay in MicroBooNE and a First Test of the MiniBooNE Low Energy Excess Under a Single Photon Hypothesis (submitted to PRL)

We report results from a search for neutrino-induced neutral current (NC) resonant Δ(1232) baryon production followed by Δ radiative decay, with a h0.8i GeV neutrino beam. Data corresponding to MicroBooNE’s first three years of operations (6.80×10 20 protons on target) are used to select single-photon events with one or zero protons and without charged leptons in the final state (1γ1p and 1γ0p, respectively). The background is constrained via an in-situ high-purity measurement of NC π 0 events, made possible via dedicated 2γ1p and 2γ0p selections. A total of 16 and 153 events are observed for the 1γ1p and 1γ0p selections, respectively, compared to a constrained background prediction of 20.5 ± 3.65(sys.) and 145.1 ± 13.8(sys.) events. The data lead to a bound on an anomalous enhancement of the normalization of NC Δ radiative decay of less than 2.3 times the predicted nominal rate for this process at the 90% confidence level (CL). The measurement disfavors a candidate photon interpretation of the MiniBooNE low-energy excess as a factor of 3.18 times the nominal NC Δ radiative decay rate at the 94.8% CL, in favor of the nominal prediction, and represents a greater than 50-fold improvement over the world’s best limit on single-photon production in NC interactions in the sub-GeV neutrino energy range.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Extreme radiation emission regime for electron beams in strong focusing ion channels and undulators

A fundamental comparison between a magnetic undulator and an ion channel, or betatron, radiation from relativistic electrons is presented. While conventional theories nominally range from the undulator (𝐾 <1) to the wiggler (𝐾 >1) regime, they are only applicable for sufficiently large Lorentz factors (𝛾 0 ≫𝐾). They therefore do not account for high 𝐾/𝛾 0 cases, for which we show that particle trajectories and radiation characteristics strongly deviate from the linear predictions in both magnetic undulators and ion channels. This problem arises from the fundamental differences between a magnetostatically and electrostatically induced oscillation. A reformulation of both the ion channel betatron wavelength and amplitude, as well as the same parameters in a magnetic undulator, permits us to compare cases with equivalent oscillation period and amplitude in the two different scenarios. The notable differences in spectral features of the two radiation mechanisms can then be addressed via numerical simulations of single particle as well as full beam dynamics. Additionally, we identify and quantify a novel transverse orbit precession effect in ion channels for particles with initial angular momentum relative to the device axis. This effect, which is significant in cases of strong transverse kinetic energy oscillations, alters both the radiation divergence and the beam emittance. In this paper, we present this new theoretical framework and compare its results with numerical simulation applied to realizable experimental tests of such radiation sources.

Frazzitta, Andrea [University of Rome “La Sapienza↗

01-07 Reactor Supplemental Shielding For the NRIC DOME Test Bed 01-07 Reactor Supplemental Shielding For the NRIC DOME Test Bed 2

A radiation shielding system is needed to protect personnel and equipment from harsh neutron and photon fluxes during: Reactor operations Post shut down operations Disassembly Decommissioning Examples of RSS driving requirements Radiological Controls Operating dose rate: the dose rate during normal reactor operations shall be <0.5 mrem/hr at the exterior wall of DOME containment Outdoor radiation limit: shielding shall provide the dose to a facility worker outside of DOME to <0.05 mrem/hr at 50 ft from the exterior wall of the DOME Temperature Reactors may have operating temperatures up to 800C The RSS shall be capable of removing up to 100 KW of heat during normal operating conditions the concrete structure has an upper temperature limit of 100°C

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Thermo-Mechanical Shock, X-Ray Transport and Radiation Response Analysis Experiments on NIF

The study of x-ray induced rapid heating and the resulting material responses - (thermomechanical shock (TMS) and thermo-structural response (TSR)) - is important to our understanding of material behavior in extreme environments. A series of high conversion efficiency (XRCE) x-ray sources have been developed for the NIF laser facility ranging in fluence and spectral content. In conjunction with source development, we have developed a new XTRRA (X-ray Transport and Radiation Response Analysis) test cassette to hold a set of samples, each at equal distance from target chamber center (TCC) where the x-ray source is placed. Design and performance details of the x-ray sources is discussed elsewhere. Here, we describe the development and use of this TMS XTRRA test cassette. The XTRRA test cassette is a snout mounted on a NIF Diagnostic Instrument Manipulator (DIM) designed to position six samples equidistant from the x-ray source to assure uniform irradiation of all samples. Photon Displacement interferometry (PDI) is used to measure the displacement of the rear surface of each sample resulting from x-ray exposure on the front of the sample. This will help determine the x-ray generated impulse on the sample. The samples are retrieved from the snout after the shot for inspection and post-shot analysis including the measurement of sample ablated mass and engineering tests examining changes in the material structure. The data from experiments are compared to predictions from LLNL’s ASC codes and used to inform models implemented in these codes. Thus, XRCE x-ray sources with the XTRRA snout at the National Ignition Facility (NIF) laser at the Lawrence Livermore National Laboratory provide the ability to expose a broad range of material samples directly to high x-ray fluence, measure shock transits, and recover the sample for further analysis post-shot.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗