Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Monte Carlo simulation of simultaneous radiation detection in the hybrid tomography system ClearPET-XPAD3/CT

Using the Geant4 based simulation framework SciFW1, a detailed simulation was performed for a detector array in the hybrid tomography prototype for small animals called ClearPET / XPAD, which was built in the Centre de Physique des Particules de Marseille. The detector system consists of an array of phoswich scintillation detectors: LSO (Lutetium Oxy-ortosilicate doped with cerium Lu{sub 2}SiO{sub 5}:Ce) and LuYAP (Lutetium Ortoaluminate of Yttrium doped with cerium Lu{sub 0.7}Y{sub 0.3}AlO{sub 3}:Ce) for Positron Emission Tomography (PET) and hybrid pixel detector XPAD for Computed Tomography (CT). Simultaneous acquisition of deposited energy and the corresponding time - position for each recorded event were analyzed, independently, for both detectors. interference between detection modules for PET and CT. Information about amount of radiation reaching each phoswich crystal and XPAD detector using a phantom in order to study the effectiveness by radiation attenuation and influence the positioning of the radioactive source {sup 22}Na was obtained. The simulation proposed will improve distribution of detectors rings and interference values will be taken into account in the new versions of detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Covariance Spectroscopy Applied to Nuclear Radiation Detection

Covariance spectroscopy is a method of processing second order moments of data to obtain information that is usually absent from average spectra. In nuclear radiation detection it represents a generalization of nuclear coincidence techniques. Correlations and fluctuations in data encode valuable information about radiation sources, transport media, and detection systems. Gaining access to the extra information can help to untangle complicated spectra, uncover overlapping peaks, accelerate source identification, and even sense directionality. Correlations existing at the source level are particularly valuable since many radioactive isotopes emit correlated gammas and neutrons. Correlations also arise from interactions within detector systems, and from scattering in the environment. In particular, correlations from Compton scattering and pair production within a detector array can be usefully exploited in scenarios where direct measurement of source correlations would be unfeasible. We present a covariance analysis of a few experimental data sets to illustrate the utility of the concept.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing and Evaluation of Passive Radiation Detection Equipment for Homeland Security

This article is concerned with test and evaluation methods for passive radiation detection equipment used in homeland security applications. The different types of equipment used in these applications are briefly reviewed and then test and evaluation methods discussed. The primary emphasis is on the test and evaluation standards developed by the American National Standards Institute’s N42 committees. Commonalities among the standards are then reviewed as well as examples of unique aspects for specific equipment types. Throughout, sample test configurations and results from testing and evaluation at Oak Ridge National Laboratory are given. The article concludes with a brief discussion of typical tests and evaluations not covered by the N42 standards and some examples of test and evaluation that involve the end users of the equipment.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Investigations of Cadmium Manganese Telluride Crystals for Room-temperature Radiation Detection

Cadmium manganese telluride (CMT) has high potential as a material for room-temperature nuclear-radiation detectors. We investigated indium-doped CMT crystals taken from the stable growth region of the ingot and compared its characteristics with that from the last-to-freeze region. We employed different techniques, including synchrotron white-beam x-ray topography (SWBXT), current-voltage (I-V) measurement, and low-temperature photoluminescence spectra, and we also assessed their responses as detectors of radiation exposure. The crystal from the stable growth region proved to be superior to that from the last-to-freeze region; it is a single-grain crystal, free of twins, and displayed a resistivity higher by one order of magnitude. The segregation of indium dopant in the ingot might be responsible for its better resistivity. Furthermore, we recorded a good response in the detector fabricated from the crystal taken from the stable growth region; its ({mu}{tau})e value was 2.6 x 10{sup -3} cm{sup 2}/V, which is acceptable for thin detectors, including their application in medicine.

36 MATERIALS SCIENCE↗

High-resolution radiation detection using Ni/SiO 2 /n-4H-SiC vertical metal-oxide-semiconductor capacitor

In this article, we demonstrate the radiation detection performance of vertical metal-oxide-semiconductor (MOS) capacitors fabricated on 20 μm thick n-4H-SiC epitaxial layers with the highest energy resolution ever reported. The 100 nm SiO2 layer was achieved on the Si face of n-4H-SiC epilayers using dry oxidation in air. The Ni/SiO2/n-4H-SiC MOS detectors not only demonstrated an excellent energy resolution of 0.42% (ΔE/E 100) for 5.48 MeV alpha particles but also caused a lower enhancement in the electronic noise components of the spectrometer compared with that observed for the best high-resolution Schottky barrier detectors. The MOS detectors also exhibited a high charge collection efficiency (CCE) of 96% at the optimized operating bias despite the presence of the oxide layer. A drift-diffusion model applied to the CCE vs gate bias voltage data revealed a minority (hole) carrier diffusion length of 24 μm. Capacitance mode deep level transient spectroscopy (C-DLTS) scans in the temperature range 84–800 K were carried out to identify the resolution limiting electrically active defects. Interestingly, the C-DLTS spectra revealed both positive and negative peaks, indicating the simultaneous presence of electron (majority) and hole (minority) trap centers. It has been inferred that at the steady-state bias for the C-DLTS measurement, the MOS detector operates in the inversion mode at certain device temperatures, causing holes to populate the minority trap centers and, hence, manifests minority carrier peaks as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

2023 Radiation Detection for Nuclear Security Summer School (Summary Report)

The Pacific Northwest National Laboratory (PNNL) hosted the 9th Radiation Detection for Nuclear Security Summer School 20-30 June 2023 in Richland, WA. The school provided students with an understanding of nuclear security challenges faced in the field and exposed them to the technical foundations and insight needed to contribute to this applied research and development area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared luminescence for real time ionizing radiation detection

Radio-luminescence (RL) optical fiber sensors enable a remote, punctual, and real time detection of ionizing radiation. However, the employment of such systems for monitoring extended radiation fields with energies above the Cerenkov threshold is still challenging, since a spurious luminescence, namely, the “stem effect,” is also generated in the passive fiber portion exposed to radiation. Here, we present experimental measurements on Yb-doped silica optical fibers irradiated with photon fields of different energies and sizes. The results demonstrate that the RL of Yb{sup 3+}, displaying a sharp emission line at about 975 nm, is free from any spectral superposition with the spurious luminescence. This aspect, in addition with the suitable linearity, reproducibility, and sensitivity properties of the Yb-doped fibers, paves the way to their use in applications where an efficient stem effect removal is required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Fabrication of a CdMnTe Nuclear Radiation Detection System

Cadmium manganese telluride (CdMnTe) is one of the ternary compounds of cadmium telluride (CdTe) that has shown great potential applications in the development of X-ray and gamma-ray detectors used in medical imaging and in the detection of radiological and nuclear threats. CdMnTe nuclear detectors are capable of operating at room temperature without cryogenic cooling. The goal of this project is to design and fabricate CdMnTe detection system that can be used in laboratory experiments for characterizing detector materials and for identification of radionuclides. The engineering design objectives include a spring-based sample holder, ability to measure electrical properties of CdTe-based semiconductor nuclear detectors, and the detection of nuclear radiations. This paper presents the design of the sample holder and the fabrication of a CdMnTe detector. The current-voltage characterization experimental results showed that the CdMnTe has the high resistivity needed for CdTe-based nuclear detectors. The results also include the response of the CdMnTe detector to the 59.5-keV gamma peak of Am-241 nuclear radiation source.

36 MATERIALS SCIENCE↗

Plastic scintillators modifications for a selective radiation detection

Recent developments of plastic scintillators are reviewed, from January 2000 to June 2015. All examples are distributed into the main application, i.e. how the plastic scintillator was modified to enhance the detection towards a given radiation particle. The main characteristics of these newly created scintillators and their detection properties are given. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method and system for calibrating gamma radiation flux levels in a solid state gamma radiation detection system

One aspect of the present disclosure comprises a method for calibrating a drive level of a non-radioactive calibration source. Another aspect of the present disclosure comprises a method for using a non-radioactive calibration source to verify correct operation of a radiation detector. Another aspect of the present disclosure comprises a radiation detection system that comprises a radiation detector and a non-radioactive calibration source that is used to verify correct operation of the radiation detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DC Ionization Conductivity of Amorphous Semiconductors for Radiation Detection Applications

DC ionization conductivity measurements were used to characterize the electrical response of amorphous semi-conductors to ionizing radiation. Two different glass systems were examined: a chalcopyrite glass (CdGexAs2; for x = 0.45-1.0) with a tetrahedrally coordinated structure and a chalcogenide glass (As40Se(60-x)Tex; where x = 0-12), with a layered or three dimensionally networked structure, depending on Te content. Changes in DC ionization current were measured as a function of the type of radiation (α or γ), dose rate, applied bias voltage, specimen thickness and temperature. These results demonstrate the potential of these materials for radiation detection applications.

36 MATERIALS SCIENCE↗

Understanding and quantifying the systematic effects of clutter within a radiation detection scene

Because of low signal-to-noise ratios, the main difficultly in real-world detection scenarios is distinguishing between benign sources and potentially-threatening radioactive materials. The variability in observed signal during a radiation detection search operation can be contributed to the stochastic nature of the underlying physics and the systematic errors inherent to the detection systems employed. This variability is compounded for dynamic detection scenarios, where objects, referred to as clutter, traverse through the primary detection scene, introducing potential suppressions in the observed signal due to the attenuation of background radiation. This study examines the impact that clutter, namely automobiles such as small utility vehicles, sedans, and trucks, produces on the observed signal in a 2 in. × 4 in. × 16 in. NaI(Tl) detector. The clutter is identified and tracked in the detection scene using a time-synced video camera and a 2-D light distance and ranging contextual sensors. Two experiments were performed on the Oak Ridge National Laboratory reservation: one using a distributed source within the scene to understand the systematics of detecting and analyzing the clutter, and the second experiment mimicking an urban environment with large buildings positioned on either side of a roadway. The experiments exhibited unique results in the amount of signal suppression and variability of the cluttered signal, both demonstrating an observable suppression from the clutter-free background. These results reveal a new potential category of signal noise intrinsic to real-world detection scenarios that should be considered when establishing detection thresholds based on expected values.

Stewart, Ian R.↗

Charge carrier mobility of halide perovskite single crystals for ionizing radiation detection

Halide perovskites have recently emerged as promising semiconductor materials for several applications including solar cells, light-emitting diodes (LEDs), and radiation detectors. The charge carrier transport properties, which could be evaluated by the mobility-lifetime (mu-tau or μ-г) product, serve an important role for the development of halide perovskites for radiation detection applications. In this perspective, we firstly explain the charge transport mechanism and the limiting factors that determine the intrinsic charge carrier mobility in halide perovskite single crystals. Then, we overview the techniques and methods that have been employed for evaluating the charge carrier mobility (for both electrons and holes). Lastly, we discuss the discrepancy between the experimentally determined carrier mobility from the literature for halide perovskite single crystals and a perspective on future developments for carrier mobility enhancement is provided.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation Detection Using Passive Surface Acoustic Wave (PSAW) Sensors

As humans venture to the Moon and beyond, the need for a small, highly sensitive and fast- responding radiation detection device is needed. Research conducted at KSC in collaboration with the University of Central Florida (UCF) and the small business Pegasense investigated the utilization of Passive Surface Acoustic Wave sensors (PSAWs) for radiation monitoring. PSAWs offer advantages over traditional methods of radiation monitoring techniques because of their low cost, compact size, high sensitivity and immediate response times.

Jacqueline W Quinn↗

Recommendations for Improving Consistency in the Radiation Fields Used During Testing of Radiation Detection Instruments for Homeland Security Applications

Several measurements and calculations were performed to illustrate the differences that can be observed in the determination of exposure rate or ambient dose equivalent rate used for testing radiation detection systems against consensus standards. The large variations observed support our recommendation that better consistency in the test radiation fields can be achieved by specifying the source activity and testing distance instead of the field strength.

47 OTHER INSTRUMENTATION↗