Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Invited Article: High resolution angle resolved photoemission with tabletop 11 eV laser

We developed a table-top vacuum ultraviolet (VUV) laser with 113.778 nm wavelength (10.897 eV) and demonstrated its viability as a photon source for high resolution angle-resolved photoemission spectroscopy (ARPES). This sub-nanosecond pulsed VUV laser operates at a repetition rate of 10 MHz, provides a flux of 2 × 10{sup 12} photons/s, and enables photoemission with energy and momentum resolutions better than 2 meV and 0.012 Å{sup −1}, respectively. Space-charge induced energy shifts and spectral broadenings can be reduced below 2 meV. The setup reaches electron momenta up to 1.2 Å{sup −1}, granting full access to the first Brillouin zone of most materials. Control over the linear polarization, repetition rate, and photon flux of the VUV source facilitates ARPES investigations of a broad range of quantum materials, bridging the application gap between contemporary low energy laser-based ARPES and synchrotron-based ARPES. We describe the principles and operational characteristics of this source and showcase its performance for rare earth metal tritellurides, high temperature cuprate superconductors, and iron-based superconductors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution measurements of the DT neutron spectrum using new CD foils in the Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility

The Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility measures the DT neutron spectrum from cryogenically layered inertial confinement fusion implosions. Yield, areal density, apparent ion temperature, and directional fluid flow are inferred from the MRS data. This paper describes recent advances in MRS measurements of the primary peak using new, thinner, reduced-area deuterated plastic (CD) conversion foils. The new foils allow operation of MRS at yields 2 orders of magnitude higher than previously possible, at a resolution down to ∼200 keV FWHM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving the off-axis spatial resolution and dynamic range of the NIF X-ray streak cameras (invited)

We report simulations and experiments that demonstrate an increase in spatial resolution of the NIF core diagnostic x-ray streak cameras by at least a factor of two, especially off axis. A design was achieved by using a corrector electron optic to flatten the field curvature at the detector plane and corroborated by measurement. In addition, particle in cell simulations were performed to identify the regions in the streak camera that contribute the most to space charge blurring. These simulations provide a tool for convolving synthetic pre-shot spectra with the instrument function so signal levels can be set to maximize dynamic range for the relevant part of the streak record.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of crystal growth rates during rapid solidification of polycrystalline aluminum by nano-scale spatio-temporal resolution in situ transmission electron microscopy

In situ investigations of rapid solidification in polycrystalline Al thin films were conducted using nano-scale spatio-temporal resolution dynamic transmission electron microscopy. Differences in crystal growth rates and asymmetries in melt pool development were observed as the heat extraction geometry was varied by controlling the proximity of the laser-pulse irradiation and the associated induced melt pools to the edge of the transmission electron microscopy support grid, which acts as a large heat sink. Experimental parameters have been established to maximize the reproducibility of the material response to the laser-pulse-related heating and to ensure that observations of the dynamical behavior of the metal are free from artifacts, leading to accurate interpretations and quantifiable measurements with improved precision. Interface migration rate measurements revealed solidification velocities that increased consistently from ∼1.3 m s{sup −1} to ∼2.5 m s{sup −1} during the rapid solidification process of the Al thin films. Under the influence of an additional large heat sink, increased crystal growth rates as high as 3.3 m s{sup −1} have been measured. The in situ experiments also provided evidence for development of a partially melted, two-phase region prior to the onset of rapid solidification facilitated crystal growth. Using the experimental observations and associated measurements as benchmarks, finite-element modeling based calculations of the melt pool evolution after pulsed laser irradiation have been performed to obtain estimates of the temperature evolution in the thin films.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-resolution anisotropy studies of ultrahigh-energy cosmic rays detected at the Pierre Auger Observatory

Here, we report a multi-resolution search for anisotropies in the arrival directions of cosmic rays detected at the Pierre Auger Observatory with local zenith angles up to 80(o) and energies in excess of 4 EeV (4 × 10 18 eV). This search is conducted by measuring the angular power spectrum and performing a needlet wavelet analysis in two independent energy ranges. Both analyses are complementary since the angular power spectrum achieves a better performance in identifying large-scale patterns while the needlet wavelet analysis, considering the parameters used in this work, presents a higher efficiency in detecting smaller-scale anisotropies, potentially providing directional information on any observed anisotropies. No deviation from isotropy is observed on any angular scale in the energy range between 4 and 8 EeV. Above 8 EeV, an indication for a dipole moment is captured, while no other deviation from isotropy is observed for moments beyond the dipole one. The corresponding p-values obtained after accounting for searches blindly performed at several angular scales, are 1.3 × 10 -5 in the case of the angular power spectrum, and 2.5 × 10 -3 in the case of the needlet analysis. While these results are consistent with previous reports making use of the same data set, they provide extensions of the previous works through the thorough scans of the angular scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Distinguishing one from many using super-resolution compressive sensing

We present that distinguishing whether a signal corresponds to a single source or a limited number of highly overlapping point spread functions (PSFs) is a ubiquitous problem across all imaging scales, whether detecting receptor-ligand interactions in cells or detecting binary stars. Super-resolution imaging based upon compressed sensing exploits the relative sparseness of the point sources to successfully resolve sources which may be separated by much less than the Rayleigh criterion. However, as a solution to an underdetermined system of linear equations, compressive sensing requires the imposition of constraints which may not always be valid. One typical constraint is that the PSF is known. However, the PSF of the actual optical system may reflect aberrations not present in the theoretical ideal optical system. Even when the optics are well characterized, the actual PSF may reflect factors such as non-uniform emission of the point source (e.g. fluorophore dipole emission). As such, the actual PSF may differ from the PSF used as a constraint. Similarly, multiple different regularization constraints have been suggested including the l 1 -norm, l 0 -norm, and generalized Gaussian Markov random fields (GGMRFs), each of which imposes a different constraint. Other important factors include the signal-to-noise ratio of the point sources and whether the point sources vary in intensity. In this work, we explore how these factors influence super-resolution image recovery robustness, determining the sensitivity and specificity. In conclusion, we determine an approach that is more robust to the types of PSF errors present in actual optical systems.

42 ENGINEERING↗

Achieving Large-Scale, High-Resolution, Full Shell Replicated X-Ray Optics: Budgeting for Sources of Spatial Resolution Errors

Technology for a large-area, high-angular resolution mirror module for a future Great Observatory x-ray mission is progressing along different paths. To date, none of these are fully developed. Work at the Marshall Space Flight Center (MSFC) seeks to leverage the benefits of full shell optics while exploring the limits of using shell replication technology for optics production. Here, we provide an updated accounting of spatial-resolution-constraining error terms to give context to recent improvements in MSFC replicated optics, as well as guidance and justification for current and future directions of research. Content includes strawman error allocations for an optical system that is parametrically Lynx-like, where the replicated-optics technology stands relative to these allocations, and methodology for mapping development plans to efficiently identify the limiting factors and approaches to overcoming these.

error budget↗

High-resolution photography of clouds from the surface: Retrieval of optical depth of thin clouds down to centimeter scales: High-Resolution Photography of Clouds

This article describes the approach and presents initial results, for a period of several minutes in north central Oklahoma, of an examination of clouds by high resolution digital photography from the surface looking vertically upward. A commercially available camera having 35-mm equivalent focal length up to 1200 mm (nominal resolution as fine as 6 µrad, which corresponds to 9 mm for cloud height 1.5 km) is used to obtain a measure of zenith radiance of a 30 m × 30 m domain as a two-dimensional image consisting of 3456 × 3456 pixels (12 million pixels). Downwelling zenith radiance varies substantially within single images and between successive images obtained at 4-s intervals. Variation in zenith radiance found on scales down to about 10 cm is attributed to variation in cloud optical depth (COD). Attention here is directed primarily to optically thin clouds, COD less than about 2. A radiation transfer model used to relate downwelling zenith radiance to COD and to relate the counts in the camera image to zenith radiance, permits determination of COD on a pixel-by-pixel basis. COD for thin clouds determined in this way exhibits considerable variation, for example, an order of magnitude within 15 m, a factor of 2 within 4 m, and 25% (0.12 to 0.15) over 14 cm. In conclusion, this approach, which examines cloud structure on scales 3 to 5 orders of magnitude finer than satellite products, opens new avenues for examination of cloud structure and evolution.

54 ENVIRONMENTAL SCIENCES↗

Imaging the Thickness of Passivation Layers for Crystalline Silicon with Micron‐Scale Spatial Resolution Using Spectral Photoluminescence

Thin films deposited on crystalline silicon surfaces are critical components of many silicon‐based devices, including high‐efficiency photovoltaic cells. Knowledge of their optical and electronic properties is important in designing and fabricating efficient solar cells, especially as the device complexity increases and includes micron‐scale features. Here, a camera‐based photoluminescence (PL) technique is developed to image the thickness of specific passivating films on silicon wafers. The technique is entirely contactless and nondestructive, requires minimal sample preparation, and provides a large dynamic range in terms of field of view, with micron‐scale spatial resolution possible. It retains the advantages of PL imaging, a mainstream technique for photovoltaic material and device characterization, and it has some extra capabilities similar to those of ellipsometry. This newly developed technique is demonstrated on hydrogenated amorphous silicon and silicon nitride films, two important passivation technologies for high‐efficiency silicon solar cells.

Nguyen, Hieu T.↗

Use of Fisher's Ratio assisted multivariate curve resolution- alternating least squares for discovery-based analysis using ultrahigh pressure liquid chromatography-high resolution mass spectrometry

Non-targeted analysis of complex chemical mixtures can be difficult considering the convoluted nature of the matrix and the potential unknown chemical differences between samples or classes of samples. Ultrahigh pressure liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-QTOF) is an ideal technique to probe chemical differences for a wide variety of samples. While UHPLC-QTOF can discover minute chemical differences down to low part per billion (ppb) concentrations with a high degree of confidence, the application of high-resolution mass spectrometry can yield massive amounts of information (∼ 10 gb per sample) that cannot be analyzed manually. Therefore, the application of chemometric techniques is mandatory for the interrogation of complex samples. Fisher's ratio (FR) assisted multivariate curve resolution-alternating least squares (MCR-ALS) was used to the discover and identify the chemical differences between two classes of materials: 1) a pond water matrix and 2) the matrix spiked with a pharmaceutical standard mix containing 17 compounds. Thirteen of the seventeen spiked compounds were discovered using FR analysis, and then five were successfully deconvoluted using MCR-ALS wherein the number of curves chosen were automatically determined using singular value decomposition (SVD). In conclusion, the use of an automated FR assisted MCR-ALS will aid in discovering trace levels of chemical components without the need for the researcher to provide potentially biased input which will aid in non-targeted workflow.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A study of the conformational isomerism of 1-iodobutane by high resolution rotational spectroscopy

The first microwave study of 1-iodobutane, performed by Steinmetz et al.in 1977) led to the determination of the B + C parameter for the anti-anti­and gauche-anti-conformers. Nearly 40 years later, this reinvestigation of 1- iodobutane, by high-resolution microwave spectroscopy, led to the determina­tion of rotational constants, centrifugal distortion constants, nuclear quadrupole coupling constants (NQCCs), and nuclear-sp rotation constants belonging to both of the two previously mentioned conformers, in addition to the gauche­ gauche-conformer, which was observed in this frequency regime for the first time. Comparisons between the three conformers of 1-iodobutanc and other iodo- and bromoalkanes are made, specifically through an analysis of the nuclear quadrupole coupling constants belonging to the iodine and bromine atoms in the respective chemical environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polar Liquid Cloud Base Detection Algorithms for High Spectral Resolution or Micropulse Lidar Data

Liquid layers in clouds affect their microphysical processes, as well as the atmospheric energy budget. However, explicit liquid cloud base height (LCBH) detection algorithms using ground-based instruments (e.g., lidars) are currently absent in the literature. Most studies use either fixed lidar parameter thresholds or cloud base height data products that do not distinguish between ice and liquid, all of which might introduce inconsistencies and errors in the resolved LCBHs. In this paper, two LCBH detection algorithms are presented; the first algorithm uses the high spectral resolution lidar (HSRL) data, and yields satisfactory results. The second algorithm incorporates micropulse lidar (MPL) data for the LCBH detection. A 1-year long comparison of data gathered at Barrow, Alaska, and McMurdo Station, Antarctica, which includes other cloud base detection methodologies (ceilometer, MPL value-added product cloud base height, LCBHs detected using a fixed MPL depolarization threshold) emphasize the merits of the MPL algorithm.

Silber, Israel↗

Vertical variation of turbulent entrainment mixing processes in marine stratocumulus clouds using high-resolution digital holography

Marine stratocumulus clouds contribute signi?cantly to the Earth’s radiation budget due to their extensive coverage and high albedo. Yet, subgrid variability in cloud properties such as aerosol concentration, droplet number and precipitation rates lead to considerable errors in global climate models. While these clouds usually have small vertical ex-tent, turbulent entrainment-mixing and precipitation can generate signi?cant variations in droplet number, size and relative dispersion with altitude. In this paper, we analyze turbulent entrainment-mixing processes and the variability in cloud microphysical properties as a function of height within a warm marine stratocumulus cloud layer over the Eastern North Atlantic. We use high resolution airborne holographic measurements and compare them with local turbulence measurements. We ?nd that entrainment-mixing is primarily inhomogeneous near cloud top leading to larger droplet sizes and homogeneous near cloud base leading to smaller droplet sizes. Further analysis of Damk¨ohler number measurements are able to explain the mixing mechanisms at di?erent cloud heights, reinforcing the importance of turbulent mixing and microphysical time scales in deter-mining cloud microphysics.

Desai, Neel↗

Mesoscale Convective Systems Represented in High Resolution E3SMv2 and Impact of New Cloud and Convection Parameterizations

Mesoscale convective systems (MCSs) play an important role in modulating the global hydrological cycle, general circulation, and radiative energy budget. In this study, we evaluate MCS simulations in the second version of U.S. Department of Energy (DOE) Energy Exascale Earth System Model (E3SMv2). E3SMv2 atmosphere model (EAMv2) is run at the uniform 0.25? horizontal resolution. We track MCSs consistently in the model and observations using the PyFLEXTRKR algorithm, which defines MCS based on both cloud-top brightness temperature (Tb) and surface precipitation. Results from using Tb only to define MCS, commonly used in previous studies, are also discussed. Furthermore, sensitivity experiments are performed to examine the impact of new cloud and convection parameterizations developed for EAMv3 on simulated MCSs. Our results show that EAMv2 simulated MCS precipitation is largely underestimated in the tropics and contiguous United States. This is mainly attributed to the underestimated precipitation intensity in EAMv2. In contrast, the simulated MCS frequency becomes more comparable to observations if MCSs are defined only based on cloud-top Tb. The Tb-based MCS tracking method, however, includes many cloud systems with very weak precipitation which conflicts with the MCS definition. This result illustrates the importance of accounting for precipitation in evaluating simulated MCSs. We also find that the new physics parameterizations help increase the relative contribution of convective precipitation to total precipitation in the tropics, but the simulated MCS properties are generally not improved. This suggests that simulating MCSs will remain a challenge for the next version of E3SM.

Zhang, Meng↗

High-resolution studies of the Majorana atomic chain platform

Ordered assemblies of magnetic atoms on the surface of conventional superconductors can be used to engineer topological superconducting phases and realize Majorana fermion quasiparticles (MQPs) in a condensed matter setting. Recent experiments have shown that chains of Fe atoms on Pb generically have the required electronic characteristics to form a one-dimensional topological superconductor and have revealed spatially resolved signatures of localized MQPs at the ends of such chains. Here we report higher-resolution measurements of the same atomic chain system performed using a dilution refrigerator scanning tunnelling microscope (STM). With significantly better energy resolution than previous studies, we show that the zero-bias peak (ZBP) in Fe chains has no detectable splitting from hybridization with other states. The measurements also reveal that the ZBP exhibits a distinctive ‘double eye’ spatial pattern on nanometre length scales. Theoretically we show that this is a general consequence of STM measurements of MQPs with substantial spectral weight in the superconducting substrate, a conclusion further supported by measurements of Pb overlayers deposited on top of the Fe chains. Lastly, we report experiments performed with superconducting tips in search of the particle–hole symmetric MQP signature expected in such measurements.

Electronic properties and materials↗

Probing charge density in materials with atomic resolution in real space

The charge distribution in materials at the nanoscale can often explain the origin of macroscopic properties such as localized conductivity or the plasmonic response and illuminate more fundamental changes in the microscopic structure such as changes in chemical bonding characteristics. Previously, direct visualization of the charge density with high spatial resolution was often a missing link in the formation of structure–property relationships, especially in heterogeneous materials systems. Furthermore, recent advancements in microscopy technology have enabled researchers to visualize the charge distribution in materials down to subatomic length scales. In this Technical Review, we discuss the developments in high-resolution real-space charge distribution imaging using diffraction techniques and electron microscopy, with a focus on the recent advancement of four-dimensional scanning transmission electron microscopy, electron holography, and applications to materials interfaces.

Electronic properties and materials↗