Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RECEIVING SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Waveform emission location determination systems and associated methods

Waveform emission location determination systems and associated methods are described. According to one aspect, a waveform emission location determination system includes a plurality of detectors configured to receive a waveform emitted by a source and to generate electrical signals corresponding to the waveform, processing circuitry configured to access data corresponding to the electrical signals generated by the detectors, use the data to determine a plurality of spheres, and wherein a surface of each of the spheres contains a location of the source when the waveform was emitted by the source, determine an intersection of the spheres, and use the intersection of the spheres to determine the location of the source when the waveform was emitted by the source.

Hughes, Michael S.↗

Financing Storage as a Transmission Asset: Initial Considerations for an Emerging Use Case

Deploying energy storage as an electric transmission system asset is a unique use case that, despite a body of policy and regulatory support, has received little attention or investment in the United States. The benefits of using storage on the transmission system—and the remaining barriers to that use—have been explored elsewhere. This paper complements that body of research by exploring the finance implications of using energy storage as a transmission asset (SATA). Because transmission infrastructure in the U.S. is generally subject to rate-of-return regulation, in which asset owners receive both a return of their invested capital and a return on that capital, storage assets deployed for that use are not subject to market volatility and have a much lower risk profile overall. That lower risk profile would, in theory, correspond to lower interest rates and other more favorable financing terms relative to a storage project deployed in a market setting. This paper draws from corollaries in other markets to estimate the expected finance impacts of SATA projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino, Rafael [Unlisted]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Secure hierarchical processing using a secure ledger

Disclosed is a system and method for processing data using blockchain technology. The system includes a memory having programmable instructions stored thereon that, when executed by a processor, cause the system to: authenticate one or more sensors in anticipation of receiving component data; receive component data, upon successful authentication; store the component data locally or to a cloud-based server and/or calculate a root value for the component data; store or embed the root value with the stored component data; condense the component data and link the condensed component data to the stored component data via the root value. The system further includes instructions to log the condensed data, including the root value, to a ledger, and to identify a tag or transaction id corresponding to the logging event for subsequent retrieval of the condensed data using the tag or transaction id.

Zhao, Wenbing↗

Elevating SolTrace's Capabilities for the Next Generation of Concentrating Solar Analysis

SolTrace is an open-source Monte Carlo ray tracing software developed at NREL. SolTrace can characterize concentrating solar thermal (CST) collector optical performance and is CST technology agnostic. Shown in Fig. 1, SolTrace is a foundational tool in NREL's CST system and component modeling suite. SolTrace's generic surface elements can flexibly model novel collector and receiver designs to predict spatial and temporal flux distributions - critical to understand for CST component design, performance prediction, and system integration. Since its initial development, SolTrace has over 1,650 references on Google Scholar, over 9,800 downloads since 2017, and has served the CST research and development community as a benchmark of 3rd party verification. SolTrace provides users with many options for defining surface shape and boundaries. However, SolTrace provides limited documentation which can result in a steep learning curve for new users. Additionally, SolTrace lacks the computational performance required to evaluate optical performance of a CST system over the course of a year and/or iteratively over design parameters in a timely manner. To address this, we are working towards a new release of SolTrace that enables increased computational throughput by implementing ray tracing acceleration structures and enabling GPU parallelization. Additionally, we are working to improve SolTrace's usability, accessibility, and maintainability by (1) automating solar position time-dependent simulation processes, (2) creating general CST collector templates of grouped elements, (3) updating the user interface to better visualize model inputs and outputs, and (4) creating a user support network through forums, "how to" videos, and documentation.

14 SOLAR ENERGY↗

PLC Vulnerabilities and Mitigations

Programmable Logic Controllers (PLCs) are used extensively in many high-importance industrial and nonindustrial settings including controlling elevators, manufacturing machines, and utility facilities such as power and natural gas, however cybersecurity protection for them has been neglected. Within recent years, PLCs have been put under more security scrutiny and experts have advocated for changes from the addition of protocol encryption and network segmentation to intrusion detection systems on the PLCs themselves. While PLC security is critical, a large portion of the PLCs available today will never receive these changes due to being legacy or the difficulty of overhauling the security on existing systems. Due to the infeasibility of applying many recommended security measures towards currently available machines, we aim to provide realistic and affordable best practices for hardening PLCs. We will first conduct security analysis and consider attack vectors within our target PLC. Once we’ve analyzed the device’s security, we will evaluate a variety of mitigation methods and create guidelines to effectively reduce the threat posed by PLC attacks with minimal disruption to operations.

42 ENGINEERING↗

​​Updates to Anaerobic Digestion Pathways for Animal Manure in R&D GREET 2025​

Livestock and poultry manure management in the U.S. is a greenhouse gas (GHG) intensive process, emitting 81.7 MMT CO 2 e in 2022 (1.5% of net U.S. GHG emissions). The primary GHG is methane (CH 4 ), with 2,312 kt released in 2022 (9% of U.S. CH 4 emissions). Manure management methods are commonly categorized by whether they are anaerobic (“wet”) or aerobic (“dry”) techniques. Although dry methods manage the largest share of manure, the majority of GHG emissions are generated during storage of manure in anaerobic conditions – typically in water-filled tanks, pits, or lagoons. There has been a 65% increase in emissions from 1990, primarily due to an increasing cattle population. Also, this rise in population has been coupled with a rise in animal confinement and density, which typically adopt wet manure management methods. Within wet methods, anaerobic bacteria proliferate and decompose volatile solids (VS) within the manure in a process called anaerobic digestion to produce roughly equal mixtures of CH 4 and carbon dioxide (CO 2 ). These GHGs are fugitive, in that they are assumed to be released to the atmosphere and contribute to GHGs within U.S. GHG inventories. If the methane is captured and purified (i.e., “upgraded”) this simultaneously mitigates GHGs that would have otherwise been released and produces a valuable energy product known colloquially as Renewable Natural Gas (RNG). Such processes are acknowledged by U.S. policy through programs such as the U.S. Renewable Fuels Standard (RFS), the federal Clean Fuel Production Credit (45Z), and state clean fuel standards (CFS). In the 45Z and CFS schemes, the GHG emissions of the business-as-usual (BAU) manure management system is taken as a baseline, and credits are received based on GHG reductions relative to this baseline. Thus, estimating the GHG emissions of the BAU scenario (also known as the “counterfactual”) is necessary.

09 BIOMASS FUELS↗

Controls Status for Fermilab’s PIP-II Project

Testing of Cryomodule first articles at PIP-II's on-site Cryomodule Test Facility (CMTF), where EPICS based controls are already being used, has been invaluable to the project. In addition to validating hardware and controls components, it has provided opportunities to build buy-in and illicit meaningful feedback early-on. A device naming convention has also been significantly refined with an internal working group and the PIP-II integration team. Compressed air and Process Control Water (PCW) systems have been installed, and operations has been engaged in Phoebus display development in preparation for a transition to operations for these systems by 2026. Cryoplant hardware has been put in place, and collaboration between controls and PIP-IIs cryo group for IOC and display development is well underway for commissioning of cryoplant systems to begin early 2026. The project has also received beneficial occupancy of the High-Bay Building in October 2025, keeping us on schedule for Warm Front End commissioning to begin in 2027.

Crisp, Dan [Fermilab]↗

Digital Grid Twin–Direct Communication Scheme Test Bed for Assessing Relay-to-Relay Radio Antenna and Optical Fiber Performance and Misoperations

This study introduces a novel “Digital Grid Twin–Direct Communication Scheme” test bed. This advanced platform evaluates point-to-point communication between transmitter and receiver relays with optical fiber and radio omnidirectional antenna systems, implemented at the Advanced Protection lab in the Grid Research Innovation and Development Center at Oak Ridge National Laboratory.

99 GENERAL AND MISCELLANEOUS↗

Performance Evaluation of an Additively Manufactured ultra-High Operating Temperature SiC Solar-Thermal Air Receiver (HOTSSTAR) Test Module

Increasing operating temperatures of solar receivers is paramount to the efficiency of concentrated solar thermal and solar power systems. GE Aerospace Research in collaboration with Heliogen Inc and Sandia National Laboratories (SNL) is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing. HOTSSTAR goal is to demonstrate SiC receiver with air exit temperatures up to 1100oC. We discuss fabrication and on-sun test results of a prototype 50kWth test module. The receiver architecture is based on a radial airflow design and consists of a series of radial SiC receiver sectors organized around central absorber. These components were fabricated using binder-jet printed SiC followed by melt-infiltration reaction bonding process. To enhance the thermo-mechanical reliability of SiC test articles in thermal gradient/ shock environment of the application, the components were laminated with GE’s MI SiC CMC. A dedicated test facility was constructed at SNL Solar Tower to evaluate the operational performance of HOTSSTAR module under solar fluxes >200 W/cm2. We report on our final 50kW test module fabrication, integration at the test facility at Sandia, and discuss on-sun test results. We compare the performance of HOTSSTAR module relative to our model predictions.

14 SOLAR ENERGY↗

Frontier system-on-chip (SoC) technology for microwave diagnostics (invited)

The next generation of fusion reactors, exemplified by projects such as the Demonstration Power Plant following the International Thermonuclear Experimental Reactor, faces the monumental challenge of proving the viability of generating electricity through thermonuclear fusion. This pursuit introduces heightened complexities in diagnostic methodologies, particularly in microwave-based diagnostics. The increased neutron fluence necessitates significant reductions in vessel penetrations and the elimination of internal diagnostics, posing substantial challenges. SoC technology offers a promising solution by enabling the miniaturization, modularization, integration, and enhancing the reliability of microwave systems. After seven years of research, our team successfully pioneered the V- and W-band system-on-chip approach, leading to the development of active transmitters and passive receiver modules applied in practical settings, notably within the DIII-D tokamak project. Arrays of these modules have supported microwave imaging diagnostics. New physics measurement results from the Electron Cyclotron Emission Imaging system on DIII-D provide compelling evidence of improved diagnostics following the adoption of SoC technology. Furthermore, we achieved a breakthrough in developing an F-band SoC, advancing higher frequency capabilities for fusion devices. These achievements represent a significant leap forward in fusion diagnostic technology, marking substantial progress toward establishing reliable and efficient plasma diagnostics for future fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring DAOS as a Burst Buffer for a 100 Gbps DAQ Real-Time Streaming System

We present an experimental evaluation of a burst buffer for a real-time DAQ streaming system designed to transmit instrument data to remote data centers. The system is based on EJ-FAT, a load balancing system capable of Nx 100Gbps streams, distributing data from event sources to processing nodes. We explore applying the DAOS system as a burst buffer to serve a number of purposes: improve resiliency, elasticity and add new functions into the processing pipeline. In the evaluation a sender transmits events over a 100Gbps network to a receiver integrated with DAOS to store the reassembled events using DAOS APIs. We evaluate the system for possible bottlenecks and provide end-to-end evaluation with a burst buffer using DAOS storage abstractions. We show that a receiver node can support 38.1 Gbps. This proves the viability of our approach and allows us to extend this work to investigate scale-out properties and new streaming optimizations.

Mei, Xinxin↗

Autonomous Hydrogen Fueling Station

This project “Autonomous Hydrogen Fueling Station” covered the autonomous refueling with both gaseous hydrogen and liquid hydrogen. The part on gaseous hydrogen focused on the development of an autonomous robotic fueling arm that would couple to a fuel cell engine for hydrogen refueling without guidance from the forklift operator and budget period. Research was also covered for the robotic fueling with a commercial vehicle. The second phase of the project created the baseline for an autonomous liquid hydrogen transfer system that would minimize boil off losses by operating at thermodynamically efficient state points. For the development of the robotic fueling arm, testing was conducted to establish a baseline measurement of the accuracy and repeatability of a human operator positioning a lift truck in front of a dispenser. The goal was to establish the range of motion required for an autonomous fueling mechanism to mate a hydrogen nozzle with a receptacle on a fuel cell system installed in a forklift. The final design comprised a selective compliance articulated robot arm (SCARA)-type mechanism with two arms for horizontal motion and a ball screw for vertical movement and color and LIDAR cameras were used for marker identification and proximity awareness to guide the robotic arm to its target receptacle. Initial tests resulted in 199 out of 200 successful attempts at autonomous coupling of the dispensing coupler and a fuel cell engine, without hydrogen. The dispenser prototype was modified to include tubing for both hydrogen fuel and air purge lines, but subsequent tests were confounded by the shoulder motor over current errors which limited the robot from getting to the fully inserted position to achieve a positive latch. Robotic hydrogen refueling was successfully demonstrated over 1.5 hours of testing, Plug completed 29 successful latches with an average number of 4 sequential latches before failure. However, a robot capable of placing the nozzle with more force is required for higher reliability. For budget period two, a small scale (10 kg / transfer) automated control system was designed that would operate valves to control pressure and flow of liquid nitrogen between a source and receiving tank with an aim to minimize boil off losses by operating at the most thermodynamically efficient state points. Control system logic flow and a P&ID were developed prior to system safety characterization via HAZOP. A control narrative and system state points were defined. Delays in approval for a change of project objective and procurement issues precluded the construction and test of the final prototype system.

08 HYDROGEN↗

From Coherence to Function: Exploring the Connection in Chemical Systems

The role of quantum mechanical coherences or coherent superposition states in excited state processes has received considerable attention in the last two decades largely due to advancements in ultrafast laser spectroscopy. These coherence effects hold promise for enhancing the efficiency and robustness of functionally relevant processes, even when confronted with energy disorder and environmental fluctuations. Understanding coherence deeply drives us to unravel mechanisms and dynamics controlled by order and synchronization at a quantum mechanical level, envisioning optical control of coherence to enhance functions or create new ones in molecular and material systems. In this frontier, the interplay between electronic and vibrational dynamics, specifically the influence of vibrations in directing electronic dynamics, has emerged as the leading principle. Here, two energetically disparate quantum degrees of freedom work in-sync to dictate the trajectory of an excited state reaction. Moreover, with the vibrational degree being directly related to the structural composition of molecular or material systems, new molecular designs could be inspired by tailoring certain structural elements. In the realm of chemical kinetics, our understanding of the dynamics of chemical transformations is underpinned by fundamental theories, such as transition state theory, activated rate theory, and Marcus theory. These theories elucidate reaction rates by considering the energy barriers that must be overcome for reactants to transform into products. Those barriers are surmounted by the stochastic nature of energy gap fluctuations within reacting systems, emphasizing that the reaction coordinate, the pathway from reactants to products, is not rigidly defined by a specific vibrational motion but encompasses a diverse array of molecular motions. While less is known about the involvement of specific intramolecular vibrational modes, their significance in certain cases cannot be overlooked. In this Account, we summarize key experimental findings that offer deeper insights into the complex electronic–vibrational trajectories encompassing excited states afforded from state-of-the-art ultrafast laser spectroscopy in three exemplary processes: photoinduced electron transfer, singlet–triplet intersystem crossing, and intramolecular vibrational energy flow in molecular systems. We delve into the rapid decoherence, or loss of phase and amplitude correlations, of vibrational coherences along promoter vibrations during subpicosecond intersystem crossing dynamics in a series of binuclear platinum complexes. This rapid decoherence illustrates the vibration-driven reactive pathways from the Franck–Condon state to the curve crossing region. We also explore the generation of new vibrational coherences induced by impulsive reaction dynamics rather than by the laser pulse in these systems, which sheds light on specific energy dissipation pathways and thereby on the progression of the reaction trajectory in the vicinity of the curve crossing on the product side. Another property of vibrational coherences, amplitude, reveals how energy can flow from one vibration to another in the electronic excited state of a terpyridine–molybdenum complex hosting a nonreactive dinitrogen substrate. In conclusion, a slight change in vibrational energy triggers a quasi-resonant interaction, leading to constructive wavepacket interference and ultimately intramolecular vibrational redistribution from a Franck–Condon active terpyridine vibration to a dinitrogen stretching vibration, energizing the dinitrogen bond.

Electrical energy↗

Quasi-optical beam tracing module development for millimeter-wave high-wavenumber collective scattering on the NSTX-U and EAST tokamaks

A Python3-based beam tracing code utilizing Quasi-Optics has been developed to track both incident and receiving beams in high-k collective millimeter wave scattering systems within magnetic fusion plasmas. In contrast to existing ray tracing codes that solely consider refraction, this beam tracing code incorporates diffraction phenomena, providing a more comprehensive calculation. Here, this enhanced capability allows for a more accurate calculation of the scattering volume and spatial resolution in high-k collective scattering systems, crucial for evaluating system performance and facilitating data analysis. Unlike Geometrical Optics, Quasi-Optics employs the complex eikonal method, representing a Gaussian beam as a collection of coupled rays to accurately preserve diffraction characteristics. The developed code is intended for application in NSTX-Upgrade and EAST high-k beam tracing analyses, targeting frequencies of 693 GHz and 270 GHz, respectively. The high-k system's primary objective is the observation of electron-scale instabilities. Employing a symplectic integrator, the code ensures numerical accuracy, assessed through the conservation of the Hamiltonian. With its precision and efficiency, the code facilitates rapid inter-shot analyses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗