Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Cryogenic readout techniques for germanium detectors

High Purity Germanium detectors are used in many applications, from nuclear and astro-particle physics, to homeland security or environment protection. Although quite standard configurations are often used, with cryostats, charge sensitive amplifiers and analog or digital acquisition systems all commercially available, it might be the case that a few specific applications, e.g. satellites, portable devices, cryogenic physics experiments, etc. also require the development of a few additional or complementary techniques. An interesting case is for sure GERDA, the Germanium Detector Array experiment, searching for neutrino-less double beta decay of {sup 76}Ge at the Gran Sasso National Laboratory of INFN - Italy. In GERDA the entire detector array, composed of semi-coaxial and BEGe naked crystals, is operated suspended inside a cryostat filled with liquid argon, that acts not only as cooling medium and but also as an active shield, thanks to its scintillation properties. These peculiar circumstances, together with the additional requirement of a very low radioactive background from all the materials adjacent to the detectors, clearly introduce significant constraints on the design of the Ge front-end readout electronics. All the Ge readout solutions developed within the framework of the GERDA collaboration, for both Phase I and Phase II, will be briefly reviewed, with their relative strength and weakness compared together and with respect to ideal Ge readout. Finally, the digital processing techniques developed by the GERDA collaboration for energy estimation of Ge detector signals will be recalled. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel 4x4 SiPM array readout with integrated preamplification stage, optimized for the PWO detectors of the EIC EEEMCal

Here we are reporting on a new readout circuit developed for the lead tungstate (PbWO4) scintillation detectors for the Electron Ion Collider (EIC) Electron Endcap Electromagnetic Calorimeter EEEMCal. The high magnetic field region precludes the use of photomultiplier tubes while the detector requirements specify good spectral resolution performance and fast pulse integration over a large dynamic range. We selected a silicon photomultiplier (SiPM) from Hamamatsu and produced a matrix of 4 x 4 sensors to cover the 20 mm x 20 mm scintillator coupling surface. Signal acquisition and amplification electronics boards were designed and integrated with the sensor board to produce a compact high performance readout package. A prototype detector was built and tested at Jefferson Lab with encouraging resolution and timing performance results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detector and Readout Assembly and Characterization for the Simons Array

The Simons Array (SA) is a cosmic microwave background (CMB) polarization experiment comprised of three telescopes that will observe the CMB at 90, 150, 220, and 270GHz with more than 22,000 Transition Edge Sensor (TES) bolometers. The cryogenic receivers inside each telescope are named POLARBEAR-2a, POLARBEAR-2b, and POLARBEAR-2c (PB-2a, PB-2b, and PB-2c, respectively). To allow for the large number of detectors, SA uses frequency-division multiplexing with multiplexing factor of 40. We describe the process developed to assemble the readout circuit repeatably for SA. After assembly, we characterize the readout circuit and TESs at cryogenic temperatures in a condition of negligible incident optical power. Impedances in the readout circuit bias our estimates of TES parameters, and we describe a method to account for this.

cosmic microwave background↗

Crosstalk Effects in Microwave SQUID Multiplexed TES Bolometer Readout

Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband circuitry, enabling readout of hundreds to thousands of channels per microwave line. As with any multiplexing technique, the channelization mechanism gives rise to electrical crosstalk which must be understood and controlled so as to not degrade the instrument sensitivity. Here, in this study, we explore implications relevant for TES bolometer array applications, focusing in particular on upcoming mm-wave observatories such as the Simons Observatory and AliCPT. We model the relative contributions of the various underlying crosstalk mechanisms, evaluate the difference between fixed-tone and tone-tracking readout systems, and discuss ways in which crosstalk nonlinearity will complicate on-sky measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of a positron-emission-tomography-based SiPM readout for compact segmented neutron imagers

Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z shielding without losing significant energy. Furthermore, fast neutrons provide a clear and unambiguous signature of the presence of SNM with few competing natural background sources. The challenge of detecting fast neutrons is twofold. First, the neutron flux from SNM are only a fraction of the corresponding gamma-ray flux. Second, fast neutrons can be difficult to differentiate from gamma rays. The ability to discriminate gamma rays from neutrons, combined with a neutron imaging capability, can in some situations enable the localization of SNM neutron sources distinct from background. With the developments of pulse-shape-sensitive plastic scintillators that offer excellent gamma-ray/neutron discrimination, and arrays of silicon photomultipliers combined with highly scalable and fast positron-emission-tomography (PET) multi-channel readout systems, field-deployable neutron imagers suitable for SNM detection might now be within reach. In this paper, we present a characterization of the performance of a recently available commercial PET-scanner readout, including its sensitivity to pulse-shape differences between fast neutrons and gamma rays, energy and timing resolution. Here, we find that, while the pulse-shape discrimination is achievable with stilbene, further improvement of the readout is required to achieve it with the PSD-capable available plastic scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mu2e Digitizer ReAdout Controller (DiRAC): characterization and radiation hardness

The Mu2e experiment at Fermilab will search for the neutrino-less coherent conversion of a muon into an electron in the field of a nucleus. Mu2e detectors comprise a straw tracker, an electromagnetic calorimeter and a veto for cosmic rays. The calorimeter employs 1348 Cesium Iodide crystals readout by silicon photo-multipliers and fast front-end, and digitization electronics. The digitization board is named DiRAC (Digitizer ReAdout Controller) and 140 cards are needed for the readout of the full calorimeter. The DiRACs are hosted in crates located on the external surface of calorimeter disks, inside the detector solenoid cryostat and must sustain very high radiation and magnetic field so it was necessary to fully qualify it. Several version of prototypes were validated for operation in a high-vacuum (10−4 Torr) and under a 1T magnetic field. An extensive radiation hardness qualification campaign, carried out with photons, 14 MeV neutron beams, and 200 MeV protons, certified the DiRAC design to sustain doses up to 12 Krad, neutron fluences up to ∼ 1011 1 MeV neq/cm2, and very low occurrences of single-event effects. The qualification campaigns and quality assurance procedures will be reviewed.

43 PARTICLE ACCELERATORS↗

Single-Shot Readout Performance of Two Heterojunction-Bipolar-Transistor Amplification Circuits at Millikelvin Temperatures

High-fidelity single-shot readout of spin qubits requires distinguishing states much faster than the T 1 time of the spin state. One approach to improving readout fidelity and bandwidth (BW) is cryogenic amplification, where the signal from the qubit is amplified before noise sources are introduced and room-temperature amplifiers can operate at lower gain and higher BW. We compare the performance of two cryogenic amplification circuits: a current-biased heterojunction bipolar transistor circuit (CB-HBT), and an AC-coupled HBT circuit (AC-HBT). Both circuits are mounted on the mixing-chamber stage of a dilution refrigerator and are connected to silicon metal oxide semiconductor (Si-MOS) quantum dot devices on a printed circuit board (PCB). The power dissipated by the CB-HBT ranges from 0.1 to 1 μW whereas the power of the AC-HBT ranges from 1 to 20 μW. Referred to the input, the noise spectral density is low for both circuits, in the 15 to 30 fA/√Hz range. The charge sensitivity for the CB-HBT and AC-HBT is 330 μe/√Hz and 400 μe/√Hz, respectively. For the single-shot readout performed, less than 10 its is required for both circuits to achieve bit error rates below 10-3, which is a putative threshold for quantum error correction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advanced readout methods for superheated emulsion detectors

Superheated emulsions develop visible vapor bubbles when exposed to ionizing radiation. They consist in droplets of a metastable liquid, emulsified in an inert matrix. The formation of a bubble cavity is accompanied by sound waves. Evaporated bubbles also exhibit a lower refractive index, compared to the inert gel matrix. These two physical phenomena have been exploited to count the number of evaporated bubbles and thus measure the interacting radiation flux. Systems based on piezoelectric transducers have been traditionally used to acquire the acoustic (pressure) signals generated by bubble evaporation. Such systems can operate at ambient noise levels exceeding 100 dB; however, they are affected by a significant dead time (>10 ms). An optical readout technique relying on the scattering of light by neutron-induced bubbles has been recently improved in order to minimize measurement dead time and ambient noise sensitivity. Beams of infra-red light from light-emitting diode (LED) sources cross the active area of the detector and are deflected by evaporated bubbles. The scattered light correlates with bubble density. Planar photodiodes are affixed along the detector length in optimized positions, allowing the detection of scattered light from the bubbles and minimizing the detection of direct light from the LEDs. A low-noise signal-conditioning stage has been designed and realized to amplify the current induced in the photodiodes by scattered light and to subtract the background signal due to intrinsic scattering within the detector matrix. The proposed amplification architecture maximizes the measurement signal-to-noise ratio, yielding a readout uncertainty of 6% (±1 SD), with 1000 evaporated bubbles in a detector active volume of 150 ml (6 cm detector diameter). In this work, we prove that the intensity of scattered light also relates to the bubble size, which can be controlled by applying an external pressure to the detector emulsion. This effect can be exploited during the readout procedure to minimize shadowing effects between bubbles, which become severe when the latter are several thousands. The detector we used in this work is based on superheated C-318 (octafluorocyclobutane), emulsified in 100 μm ± 10% (1 SD) diameter drops in an inert matrix of approximately 150 ml. The detector was operated at room temperature and ambient pressure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial assessment of second generation of large-area picosecond photodetectors with multi-channel systems-on-a-chip readout

Here, we first briefly describe the history and motivation behind Cherenkov and scintillation light detection. We then discuss the instrumentation needed to detect these photons as it applies to both photodetectors and readout electronics. One of the motivations is future large neutrino detectors that could, in principle, differentiate between Cherenkov and scintillation light if using novel water-based scintillators. In this paper, we present the first measurements utilizing the second generation of Large Area Picosecond Photodetectors (LAPPDs) in conjunction with commercial system-on-a-chip readouts from Nalu Scientific—in particular, the High Density System on Chip (HDSoC) and Advanced ASoC Rapid Digitizer, Variable Adaptive Readout Chip (AARDVARC) platforms. These state-of-the-art full-waveform digitizers feature sampling rates on the order of 1 and 10 samples per nanosecond, respectively. Using a picosecond laser, we measured the timing jitter between a pair of LAPPD channels, demonstrating the potential of this setup for precise timing applications.

Li, V. A. [Lawrence Livermore National Laboratory ↗

Optimizing Charge-coupled Device Readout Enabled by the Floating-gate Amplifier

Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future space-based imaging of extremely faint objects on missions such as the Habitable Worlds Observatory. Building upon the capability of the Skipper CCD to achieve deeply sub-electron noise floors, MAS CCDs utilize multiple floating-gate amplifiers along the serial register to increase the readout speed by a factor of the number of output nodes compared to a Skipper CCD. We introduce and experimentally demonstrate on a 16-channel prototype device new readout techniques that exploit the MAS CCD’s floating-gate amplifiers to optimize the correlated double sampling by resetting once per line instead of once per pixel. With this new mode, we find an optimal filter to subtract the noise from the signal during read out. We also take advantage of the MAS CCD’s structure to tune the read time by independently changing integration times for the signal and reference level. Together with optimal weighted averaging of the 16 outputs, these approaches enable us to reach a sub-electron noise of 0.9 e − rms pix −1 at 19 μs pix −1 for a single charge measurement per pixel—simultaneously giving a 30% faster readout time and 10% lower read noise compared to performance previously evaluated without these techniques.

Lin, Kenneth W. (ORCID:0000000189672281)↗

The COLUTA ADC ASIC and the ATLAS HL-LHC Liquid Argon Front-End Readout

Abstract The upgraded High-Luminosity Large Hadron Collider (HL-LHC) requires a new radiation tolerant ATLAS Liquid Argon (LAr) Calorimeter readout operating at 40 MHz with 16-bit dynamic range. The Front-End Board 2 (FEB2) will provide the front-end readout for the calorimeter, and will interface a series of custom ASICs due to radiation tolerance requirements of the HL-LHC. The COLUTA is a 65 nm CMOS custom 8-channel 15-bit 40 MSPS ADC ASIC developed for this application. This contribution will present performance results of the final prototype of the COLUTA, surpassing specifications at >11.5 ENOB for relevant frequencies, as well as non-linearity and radiation requirements. Preliminary integration results of the front-end readout components will also be described by means of the FEB2 Pre-Prototype, the “Slice Testboard”.

Instruments & Instrumentation↗

Photon temporal-mode readout for inference of neutron star merger remnant gravitational waves

Gravitational waves emitted after neutron star binary coalescences and the information they carry about dense matter are a high-priority target for next-generation detectors. Even though such detectors are expected to observe millions of signals, detectable postmerger emission will remain rare. Here, in this work, we explore postmerger detectability and inference through an alternative detector readout scheme for data dominated by quantum-noise, which is the case above 1 kHz; photon-counting. In such a readout, signals and noise become quantized into discrete distributions corresponding to the detection of single photons measured in a chosen basis of modes. Through simulated data, we demonstrate that photon counting can be efficient even for weak signals. We find ∼1 in 100 signals with a postmerger signal-to-noise ratio of 0.2 can result in a single photon and thus be detected. Furthermore, after 2 ×10 4 signals—equivalent to 10 −2 to 1.5 years of observation—photon counting results in a twofold improvement in the measurement of the radius of a 1.6⁢𝑀 ⊙ neutron star. Constraints can be further tightened if the detector classical noise is reduced. Photon counting offers a promising alternative to traditional homodyne readout techniques for extracting information from low signal-to-noise ratio postmerger signals.

gravitational wave detection↗

Improving qubit readout with hidden Markov models

We demonstrate the application of pattern recognition algorithms via hidden Markov models (HMM) for qubit readout. This scheme provides a state-path trajectory approach capable of detecting qubit-state transitions and makes for a robust classification scheme with higher starting-state assignment fidelity than when compared to a multivariate Gaussian or a support vector machine scheme. Therefore, the method also eliminates the qubit-dependent readout time optimization requirement in current schemes. Using a HMM state discriminator we estimate fidelities reaching the ideal limit. Unsupervised learning gives access to transition matrix, priors, and IQ distributions, providing a toolbox for studying qubit-state dynamics during strong projective readout.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Perturbative readout-error mitigation for near-term quantum computers

Readout errors on near-term quantum computers can introduce significant error to the empirical probability distribution sampled from the output of a quantum circuit. These errors can be mitigated by classical postprocessing given the access of an experimental response matrix that describes the error associated with the measurement of each computational basis state. However, the resources required to characterize a complete response matrix and to compute the corrected probability distribution scale exponentially with the number of qubits, n . In this work, we modify standard matrix inversion techniques using perturbative approximations with significantly reduced complexity and bounded error when the likelihood of high-order bit-flip events is strongly suppressed. Given a characteristic error rate q , we discuss a method to recover the probability of the all-zeros bit string p 0 by sampling only a small subspace of the response matrix before inverting readout error, resulting in a relative speedup of poly [ 2 n / ( n w ) ] , which we motivate using a simplified error model for which the approximation incurs only O ( q w ) error for some integer w . We then provide a generalized technique to efficiently recover full output distributions with O ( q w ) error in the perturbative limit. These approximate techniques for readout-error correction may greatly accelerate near-term quantum computing applications.

97 MATHEMATICS AND COMPUTING↗

A Sub-Electron-Noise Multi-Channel Cryogenic Skipper-CCD Readout ASIC

The MIDNA application specific integrated circuit (ASIC) is a skipper-CCD readout chip fabricated in a 65 nm LP-CMOS process that is capable of working at cryogenic temperatures. The chip integrates four front-end channels that process the skipper-CCD signal and performs differential averaging using a dual slope integration (DSI) circuit. Each readout channel contains a pre-amplifier, a DC restorer, and a dual-slope integrator with chopping capability. The integrator chopping is a key system design element in order to mitigate the effect of low-frequency noise produced by the integrator itself, and it is not often required with standard CCDs. Each channel consumes 4.5 mW of power, occupies 0.156 mm${^2}$ area and has an input referred noise of 2.7${\mu\nu}_{rms}$. It is demonstrated experimentally to achieve sub-electron noise when coupled with a skipper-CCD by means of averaging samples of each pixel. Here, sub-electron noise is shown in three different acquisition approaches. The signal range is 6000 electrons. The readout system achieves 0.2${e^{-}}$ RMS by averaging 1000 samples with MIDNA both at room temperature and at 180 Kelvin.

1/f noise↗

Cryogenic Front-End ASICs for Low-Noise Readout of Charge Signals

This paper presents design details and measurement results of LArASIC, a front-end application specific integrated circuit (ASIC) designed for low-noise readout of charge signals generated in neutrino study experiments within liquid argon time projection chambers. LArASIC comprises of 16-channels of programmable charge amplification and pulse shaping stages that provide a voltage readout proportional to the input charge and was optimized for operation at liquid argon temperature, i.e., 89 K. The chip was fabricated in a 180 nm CMOS process. Measurements at liquid nitrogen temperature, i.e., 77 K, indicate that the channel outputs have high linearity (INL < 0.1%) within the operating range, an equivalent noise charge of 534 electrons for a peaking time of 1 µs and a detector capacitance of 150 pF, and a worst-case inter-channel cross-talk of 0.35%. The paper also presents design choices made in the process of migrating LArASIC to CHARMS, an ASIC to be fabricated in a 65 nm process that includes all features provided by LArASIC, along with additional digital programmability for improved robustness and flexibility. CHARMS is intended for use in future high-energy physics experiments that require high-resolution charge or light readout with shorter pulse peaking times.

47 OTHER INSTRUMENTATION↗

Skipper-in-CMOS: Nondestructive Readout With Subelectron Noise Performance for Pixel Detectors

The Skipper-in-CMOS image sensor integrates the nondestructive readout capability of skipper charge coupled devices (Skipper-CCDs) with the high conversion gain of a pinned photodiode (PPD) in a CMOS imaging process while taking advantage of in-pixel signal processing. This allows both single photon counting as well as high frame rate readout through highly parallel processing. The first results obtained from a ${15} \times {15}~\mu $ m2 pixel cell of a Skipper-in-CMOS sensor fabricated in Tower Semiconductor’s commercial 180-nm CMOS image sensor process are presented. Measurements confirm the expected reduction of the readout noise with the number of samples down to deep subelectron noise of $0.15\text {e}^ - $ , demonstrating the charge transfer operation from the PPD and the single photon counting operation when the sensor is exposed to light. This article also discusses new testing strategies employed for its operation and characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Versatile High-Gain Low-Noise Readout ASIC for Silicon Microstrip Tracking Detectors

This work presents Turpial, a custom-designed low- power front-end readout ASIC for microstrip silicon sensors. Implemented in 130 nm CMOS technology, the chip integrates 64 identical readout channels, each including a configurable charge-sensitive amplifier, a bipolar pulse shaper, a 32-sample 50 Msps analog memory, and a 12-bit RC-hybrid SAR ADC operating at 1 Msps. To satisfy the target power budget of 5 mW per channel, the architecture employs a time-decoupled readout scheme in which fast transient signals are first captured in the analog memory and subsequently digitized at a lower rate. Turpial supports a wide dynamic range from 1 kℎ+ to 1 Mℎ+ while maintaining low noise performance, targeting an equivalent noise charge (ENC) below 200 𝑒−including the sensor, and providing a maximum gain of 1500 mV/fC. A digital block manages slow control, data acquisition, and data serialization through dual CML 300 Mb/s serializers. In addition, an on-chip reference circuit, based on a sub-1 V bandgap reference and an integrated LDO regulator, eliminates the need for external reference circuitry. Experimental results demonstrate that both the individual building blocks and the fully integrated ASIC meet the design specifications.

Hernandez, Hugo [Stanford University] (ORCID:00000↗