Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Metabolic cartography: experimental quantification of metabolic fluxes from isotopic labelling studies

For the past decade, flux maps have provided researchers with an in-depth perspective on plant metabolism. As a rapidly developing field, significant headway has been made recently in computation, experimentation, and overall understanding of metabolic flux analysis. These advances are particularly applicable to the study of plant metabolism. New dynamic computational methods such as non-stationary metabolic flux analysis are finding their place in the toolbox of metabolic engineering, allowing more organisms to be studied and decreasing the time necessary for experimentation, thereby opening new avenues by which to explore the vast diversity of plant metabolism. Also, improved methods of metabolite detection and measurement have been developed, enabling increasingly greater resolution of flux measurements and the analysis of a greater number of the multitude of plant metabolic pathways. Methods to deconvolute organelle-specific metabolism are employed with increasing effectiveness, elucidating the compartmental specificity inherent in plant metabolism. Advances in metabolite measurements have also enabled new types of experiments, such as the calculation of metabolic fluxes based on (CO2)-C-13 dynamic labelling data, and will continue to direct plant metabolic engineering. Newly calculated metabolic flux maps reveal surprising and useful information about plant metabolism, guiding future genetic engineering of crops to higher yields. Due to the significant level of complexity in plants, these methods in combination with other systems biology measurements are necessary to guide plant metabolic engineering in the future.

O'Grady, J↗

Quantification of beam complexity in intensity-modulated radiation therapy treatment plans

Purpose: Excessive complexity in intensity-modulated radiation therapy (IMRT) plans increases the dose uncertainty, prolongs the treatment time, and increases the susceptibility to changes in patient or target geometry. To date, the tools for quantitative assessment of IMRT beam complexity are still lacking. In this study, The authors have sought to develop metrics to characterize different aspects of beam complexity and investigate the beam complexity for IMRT plans of different disease sites. Methods: The authors evaluated the beam complexity scores for 65 step-and-shoot IMRT plans from three sites (prostate, head and neck, and spine) and 26 volumetric-modulated arc therapy (VMAT) plans for the prostate. On the basis of the beam apertures and monitor unit weights of all segments, the authors calculated the mean aperture area, extent of aperture shape irregularity, and degree of beam modulation for each beam. Then the beam complexity values were averaged to obtain the complexity metrics of the IMRT plans. The authors studied the correlation between the beam complexity metrics and the quality assurance (QA) results. Finally, the effects of treatment planning parameters on beam complexity were studied. Results: The beam complexity scores were not uniform among the prostate IMRT beams from different gantry angles. The lateral beams had larger monitor units and smaller shape irregularity, while the anterior-posterior beams had larger modulation values. On average, the prostate IMRT plans had the smallest aperture irregularity, beam modulation, and normalized monitor units; the head and neck IMRT plans had large beam irregularity and beam modulation; and the spine stereotactic radiation therapy plans often had small beam apertures, which may have been associated with the relatively large discrepancies between planned and QA measured doses. There were weak correlations between the beam complexity scores and the measured dose errors. The prostate VMAT beams showed greater complexity than the prostate step-and-shoot IMRT beams. In the treatment planning process, the beam complexity increased as the minimum segment area decreased and as the number of optimization iterations and the maximum number of segments increased. Conclusions: The proposed metrics were effective in characterizing the beam complexity of different disease sites and for different treatment modalities. Efforts should be made to reduce the unnecessary complexity of IMRT beams to minimize the radiation dose uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Two-Step Approach to Uncertainty Quantification of Core Simulators

For the multiple sources of error introduced into the standard computational regime for simulating reactor cores, rigorous uncertainty analysis methods are available primarily to quantify the effects of cross section uncertainties. Two methods for propagating cross section uncertainties through core simulators are the XSUSA statistical approach and the “two-step” method. The XSUSA approach, which is based on the SUSA code package, is fundamentally a stochastic sampling method. Alternatively, the two-step method utilizes generalized perturbation theory in the first step and stochastic sampling in the second step. The consistency of these two methods in quantifying uncertainties in the multiplication factor and in the core power distribution was examined in the framework of phase I-3 of the OECD Uncertainty Analysis in Modeling benchmark. With the Three Mile Island Unit 1 core as a base model for analysis, the XSUSA and two-step methods were applied with certain limitations, and the results were compared to those produced by other stochastic sampling-based codes. Based on the uncertainty analysis results, conclusions were drawn as to the method that is currently more viable for computing uncertainties in burnup and transient calculations.

Yankov, Artem↗

Uncertainty quantification in elastic constants of SiC f /SiC m tubular composites using global sensitivity analysis

Silicon carbide fiber and silicon carbide matrix (SiC f /SiC m ) tubes produced through the chemical vapor infiltration process have become a candidate cladding material in nuclear applications. The performance of this composite is influenced by many variables such as braiding angle, porosity, material properties, etc., which vary over a range of values due to the inherent fluctuations in the manufacturing process. In this study, the variability in elastic constants of SiC f /SiC m composite has been quantified through multiscale finite element (FE) simulations, variable screening, and high-fidelity surrogate modeling. The key variables dominantly affecting the elastic constants of SiC f /SiC m tubes were identified using global sensitivity analysis. A surrogate to the high-fidelity FE-based model was used in Monte Carlo simulations to generate a hundred thousand samples from which the uncertainty in elastic constants was assessed. It turned out that the coefficient of variation was less than 10%.

Materials Science↗

Multifidelity Uncertainty Quantification with Applications in Wind Turbine Aerodynamics: Preprint

The propagation of input uncertainty through engineering models allows designers to better understand the range of possible outcomes resulting from design decisions. This could lead to greater trust between modelers and stakeholders in the wind energy industry. In this study, we apply multilevel-multifidelity Monte Carlo sampling to flow over an airfoil, assuming uncertainty in the inflow conditions, and characterize the associated computational savings compared to standard Monte Carlo approaches. The truth model is provided by an airfoil simulation with a very fine computational time step, and auxiliary lower-level models are provided by simulations with coarser time steps. Reynolds-averaged Navier Stokes and detached eddy simulations are used to obtain two different model fidelities. The primary quantity of interest for this analysis is the lift force, which is examined for a range of angles of attack. We launch an initial set of 'trial' samples to determine the optimal allocation of model evaluations, and these trial evaluations are used to inform a larger sampling effort. Using the multilevel-multifidelity approach, we achieve roughly an order of magnitude variance reduction in expected lift as compared to the standard Monte Carlo approach with an equivalent computational cost.

17 WIND ENERGY↗

Temperature profiling at the American WAKE ExperimeNt (AWAKEN): methodology and uncertainty quantification

We quantify the accuracy of the temperature profiling from ground-based spectral infrared radiance observations at the American WAKE ExperimeNt (AWAKEN). Results from pre-campaign tests and comparisons with in-situ ground-based and airborne sensors at AWAKEN indicate that temperature profiles agree satisfactorily with traditional instruments for wind energy applications. The bias is within a fraction of a degree and appears to be related to atmospheric stability. Root-mean-square differences from the reference instruments are always smaller than a degree and are often well described by the online uncertainty estimation product. Height-to-height and site-to-site temperature differences are in excellent agreement with in-situ observations, which justifies the use of temperature profilers to characterize static stability and spatial gradients of temperature.

17 WIND ENERGY↗