Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Thermal spray coating of Al-Cu-Fe quasicrystals: Dynamic observations and surface properties

In this study, we prepared Al-Cu-Fe quasicrystals (QCs) via thermal spray coating after optimizing the process parameters. Both in-situ XRD and in-situ TEM were used to investigate the thermal stability of QC phase. These dynamic techniques uniquely allow for a direct observation of QC growth upon heating and cooling. We show that the cubic β-Al-Cu-Fe is the dominant phase at room temperature (initial stage), but with an increase in temperature, the QC takes over at 650 °C, consistent with thermodynamic calculations. Further increasing the temperature to 800 °C, the QC phase transforms into cubic β-Al-Cu-Fe such that the β-Al-Cu-Fe phase is the only phase in existence at 870 °C. Based on this result, we annealed the sample after thermal spray deposition for one hour at 650 °C, which yielded an almost pure QC coating. The contact angle (against water) before annealing was 50°±4° but improved dramatically to 130°±5° after annealing at 650 °C for 1 h. Here, this study provides a better understanding of QC formation during heat treatment as well as that of other secondary phases. Furthermore, these results can be used to manufacture QC coatings with enhanced interfacial properties that are central to technological applications.

36 MATERIALS SCIENCE↗

Vertical dependence of horizontal variation of cloud microphysics: observations from the ACE-ENA field campaign and implications for warm-rain simulation in climate models

Abstract. In the current global climate models (GCMs), the nonlinearity effect of subgrid cloud variations on the parameterization of warm-rain process, e.g., the autoconversion rate, is often treated by multiplying the resolved-scale warm-rain process rates by a so-called enhancement factor (EF). In this study, we investigate the subgrid-scale horizontal variations and covariation of cloud water content (qc) and cloud droplet number concentration (Nc) in marine boundary layer (MBL) clouds based on the in situ measurements from a recent field campaign and study the implications for the autoconversion rate EF in GCMs. Based on a few carefully selected cases from the field campaign, we found that in contrast to the enhancing effect of qc and Nc variations that tends to make EF > 1, the strong positive correlation between qc and Nc results in a suppressing effect that tends to make EF < 1. This effect is especially strong at cloud top, where the qc and Nc correlation can be as high as 0.95. We also found that the physically complete EF that accounts for the covariation of qc and Nc is significantly smaller than its counterpart that accounts only for the subgrid variation of qc, especially at cloud top. Although this study is based on limited cases, it suggests that the subgrid variations of Nc and its correlation with qc both need to be considered for an accurate simulation of the autoconversion process in GCMs.

54 ENVIRONMENTAL SCIENCES↗

SRT Evaluation of AIRS Version-6.02 and Version-6.02 AIRS Only (6.02 AO) Products

Version-6 contains a number of significant improvements over Version-5. This report compares Version-6 products resulting from the advances listed below to those from Version-5. 1. Improved methodology to determine skin temperature (T(sub s)) and spectral emissivity (Epsilon(sub v)). 2. Use of Neural-net start-up state. 3. Improvements which decrease the spurious negative Version-5 trend in tropospheric temperatures. 4. Improved QC methodology. Version-6 uses separate QC thresholds optimized for Data Assimilation (QC=0) and Climate applications (QC=0,1) respectively. 5. Channel-by-channel clear-column radiances R-hat(sub tau) QC flags. 6. Improved cloud parameter retrieval algorithm. 7. Improved OLR RTA. Our evaluation compared V6.02 and V6.02 AIRS Only (V6.02 AO) Quality Controlled products with those of Version-5.0. In particular we evaluated surface skin temperature T(sub s), surface spectral emissivity Epsilon(sub v), temperature profile T(p), water vapor profile q(p), OLR, OLR(sub CLR), effective cloud fraction alpha-Epsilon, and cloud cleared radiances R-hat(sub tau) . We conducted two types of evaluations. The first compared results on 7 focus days to collocated ECMWF truth. The seven focus days are: September 6, 2002; January 25, 2003; September 29, 2004; August 5, 2005; February 24, 2007; August 10, 2007; and May 30, 2010. In these evaluations, we show results for T(sub s), Epsilon(sub v), T(p), and q(p) in terms of yields, and RMS differences and biases with regard to ECMWF. We also show yield trends as well as bias trends of these quantities relative to ECMWF truth. We also show yields and accuracy of channel by channel QC d values of R-hat(sub tau) for V6.02 and V6.02 AO. Version-5 did not contain channel by channel QC d values of R-hat(sub tau). In the second type of evaluation, we compared V6.03 monthly mean Level-3 products to those of Version-5.0, for four different months: January, April, July, and October; in 3 different years 2003, 2007, and 2011. In particular, we compared V6.03 and V5.0 trends of T(p), q(p), alpha-Epsilon, OLR, and OLR(sub CLR) computed based on results for these 12 time periods

Susskind, Joel↗

The Quality Control Algorithms Used in the Creation of NASA Kennedy Space Center Lightning Protection System Towers Meteorological Database

An accurate database of meteorological data is essential for designing any aerospace vehicle and for preparing launch commit criteria. Meteorological instrumentation were recently placed on the three Lightning Protection System (LPS) towers at Kennedy Space Center (KSC) launch complex 39B (LC-39B), which provide a unique meteorological dataset existing at the launch complex over an extensive altitude range. Data records of temperature, dew point, relative humidity, wind speed, and wind direction are produced at 40, 78, 116, and 139 m at each tower. The Marshall Space Flight Center Natural Environments Branch (EV44) received an archive that consists of one-minute averaged measurements for the period of record of January 2011 - April 2015. However, before the received database could be used EV44 needed to remove any erroneous data from within the database through a comprehensive quality control (QC) process. The QC process applied to the LPS towers' meteorological data is similar to other QC processes developed by EV44, which were used in the creation of meteorological databases for other towers at KSC. The QC process utilized in this study has been modified specifically for use with the LPS tower database. The QC process first includes a check of each individual sensor. This check includes removing any unrealistic data and checking the temporal consistency of each variable. Next, data from all three sensors at each height are checked against each other, checked against climatology, and checked for sensors that erroneously report a constant value. Then, a vertical consistency check of each variable at each tower is completed. Last, the upwind sensor at each level is selected to minimize the influence of the towers and other structures at LC-39B on the measurements. The selection process for the upwind sensor implemented a study of tower-induced turbulence. This paper describes in detail the QC process, QC results, and the attributes of the LPS towers meteorological database.

Orcutt, John M.↗

Evaluation of the Danish Aerospace Corporation Portable Pulmonary Function System

A research project designed to investigate changes in maximal oxygen consumption (VO2max) during and following long duration flight on the International Space Station (ISS) has recently been completed. The device used to measure VO2 on board ISS, the Portable Pulmonary Function System (PPFS) manufactured by the Danish Aerospace Corporation (DAC), is based on previous-generation devices manufactured by DAC, but the PPFS has not been validated for analyzing metabolic gases or measuring cardiac output (Qc). The purpose of the present evaluation is to compare PPFS metabolic gas analysis measurements to measurements obtained using a clinically-validated system (ParvoMedics TrueOne(c) 2400 system; Parvo). In addition, Qc data collected with the PPFS were compared to Qc measurements from echocardiography. METHODS: Ten subjects completed three cycle exercise tests to maximal exertion. The first test was conducted to determine each subject's VO2max and set the work rates for the second and third (comparison) tests. The protocol for the two comparison tests consisted of three 5-minute stages designed to elicit 25%, 50%, and 75% VO2max (based upon results from the initial test), followed by 1-minute stages of increasing work rate (25 watt/minute) until the subject reached maximal effort. During one of the two comparison tests, metabolic gases and Qc were assessed with the PPFS; metabolic gases and Qc were assessed with the Parvo and by echocardiography, respectively, during the other test. The order of the comparison tests was counterbalanced. VO2max and maximal work rate during the comparison tests were compared using t tests. Mixed-effects regression modeling was used to analyze submaximal data. RESULTS: All of the data were within normal physiological ranges. The PPFS-measured values for VO2max were 6% lower than values obtained with the Parvo (PPFS: 3.11 +/- 0.75 L/min; Parvo: 3.32 +/- 0.87 L/min; mean +/- standard deviation; P = 0.02); this difference is probably due to flow restriction imposed by the PPFS Qc accessories. Submaximal VO2 values were slightly lower when measured with the PPFS, although differences were not physiologically relevant. The PPFS-measured values of submaximal carbon dioxide production (VCO2) were lower than the data obtained from Parvo, which could be attributed to lower fractions of expired carbon dioxide measured by the PPFS. The PPFS Qc values tended to be lower than echocardiography-derived values. CONCLUSIONS: The results of the present study indicate a need to further examine the PPFS and to better quantify its reproducibility; however, none of the findings of the current evaluation indicate that the PPFS needs to be replaced or modified.

Portable Pulmonary Function System (PPFS)↗

Quality Control Methods of Tower Data at Kennedy Space Center’s Launch Complex 39-B and the USAF Cape Canaveral 500 Foot Tower

The National Aeronautics and Space Administration (NASA) has long used meteorological data from weather towers located at Kennedy Space Center (KSC) and the United States Air Force’s Eastern Range(ER) in support of their various launch vehicles and climate studies. Some of the most valuable data is gathered at the Launch Complex 39-B (LC39-B) and the 500 foot tower located approximately two miles west of LC39-B and three miles north of the Vehicle Assembly Building (VAB). The data from LC39-B gives NASA Space Launch System (SLS) engineers valuable insight into the weather the vehicle can expect at the pad, while the 500 foot tower has a longer period of record and has been used by the Shuttle and SLS programs. However, numerous data quality (DQ) control issues have arisen when utilizing this data for analysis. In addition, instrumentation tends to deteriorate faster than normal due to the corrosive nature of the high salt content in the air. NASA’s Natural Environments branch has developed several QC databases of these towers, but these studies were for fixed periods of records. EV44 identified a need for a continually updated and QC’ed database of tower data not only to provide along term QC’ed database for vehicle and climate analyses, but also to provide the capability to investigate recent weather events such as downbursts and other high wind events. This study follows the methods developed in prior Natural Environment QC tower databases, which includes variable specific QC thresholds and checks used to generate QC flags. However, this study developed new techniques such as the development and design of the graphical user interface (GUI) for manual verification, and the creation of the final monthly QC files.

Quality Control↗

Quantum key distribution using card, base station and trusted authority

Techniques and tools for quantum key distribution ("QKD") between a quantum communication ("QC") card, base station and trusted authority are described herein. In example implementations, a QC card contains a miniaturized QC transmitter and couples with a base station. The base station provides a network connection with the trusted authority and can also provide electric power to the QC card. When coupled to the base station, after authentication by the trusted authority, the QC card acquires keys through QKD with a trusted authority. The keys can be used to set up secure communication, for authentication, for access control, or for other purposes. The QC card can be implemented as part of a smart phone or other mobile computing device, or the QC card can be used as a fillgun for distribution of the keys.

97 MATHEMATICS AND COMPUTING↗

Quantum key distribution using card, base station and trusted authority

Techniques and tools for quantum key distribution ("QKD") between a quantum communication ("QC") card, base station and trusted authority are described herein. In example implementations, a QC card contains a miniaturized QC transmitter and couples with a base station. The base station provides a network connection with the trusted authority and can also provide electric power to the QC card. When coupled to the base station, after authentication by the trusted authority, the QC card acquires keys through QKD with a trust authority. The keys can be used to set up secure communication, for authentication, for access control, or for other purposes. The QC card can be implemented as part of a smart phone or other mobile computing device, or the QC card can be used as a fillgun for distribution of the keys.

97 MATHEMATICS AND COMPUTING↗

Plasmon-enhanced broad-band quantum-cutting of NaBaPO{sub 4}:Eu{sup 2+},Yb{sup 3+} phosphor decorated with Ag nano-particles

Highlights: • High quantum-cutting (QC) efficiency as 197.4% was obtained in NaBaPO{sub 4}:Eu{sup 2+},Yb{sup 3+}. • Strong and broad excitation band derived from Eu{sup 2+} was detected and analyzed. • Plasmon enhancement of broad-band QC emission was reported for the first time. - Abstract: The NaBaPO{sub 4}:Eu{sup 2+},Yb{sup 3+} quantum-cutting (QC) phosphors were prepared by the solid-state reaction. We confirm the luminescence of Yb{sup 3+} is mainly derived from QC rather than common down-conversion. The QC efficiency η{sub QE} calculated from the luminescence decay curves reached a maximum as high as 197.4%. Furthermore, the QC emission was enhanced by decorating with quasi-spherical and uniform (∼100 nm) Ag nano-particles, due to localized surface plasmon resonance. The enhancement factor reached a maximum as 1.2337.

36 MATERIALS SCIENCE↗

Investigation on visible quantum cutting of Tb{sup 3+} in oxide hosts

Visible quantum cutting (QC) through downconversion was observed upon 4f{sup 8}-4f{sup 7}5d{sup 1} excitation of Tb{sup 3+} in both BaGdB{sub 9}O{sub 16} and Ca{sub 8}MgGd(PO{sub 4}){sub 7} compounds. The QC involves a cross relaxation process between two neighboring Tb{sup 3+}. Modified and new QC models are proposed based on the QC mechanisms in Gd{sup 3+}-Tb{sup 3+} system. Two calculation equations for the cross relaxation efficiency are suggested according to the energy transfer theory and spectral results. By studying the spectral characteristics of Tb{sup 3+} in hosts from fluoride to oxide, it indicates that the visible QC in Gd{sup 3+}-Tb{sup 3+} system may occur mainly depending on the structural features of phosphors, rather than the phonon energies of matrixes. All of the above conclusions have meaning of guidance for investigating other phosphors with QC phenomenon.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

THz time-domain characterization of amplifying quantum-cascade metasurface

An amplifying quantum-cascade (QC) metasurface, the key component of the QC vertical-external-cavity surface-emitting-laser (VECSEL), is studied as a function of injected current density using reflection-mode terahertz time domain spectroscopy. Nearly perfect absorption is measured at zero bias, which is associated with the transition from the weak to strong coupling condition between the metasurface resonance and an intersubband transition within the QC material. An increase in reflectance is observed as the device is biased, both due to reduction in intersubband loss and the presence of intersubband gain. Significant phase modulation associated with the metasurface resonance is observed via electrical control, which may be useful for electrical tuning of QC-VECSEL. These results provide insight into the interaction between the intersubband QC-gain material and the metasurface and modify the design rules for QC-VECSELs for both biased and unbiased regions.

42 ENGINEERING↗

Production and testing of the powerboard for ATLAS ITk Strip barrel modules

The upgrade of the ATLAS ITk strips detector for HL-LHC will employ a custom PCB (powerboard) for on-module DC-DC conversion, HV switching, and monitoring. Production of about 14100 of such PCBs with high reliability is a big challenge. In this paper we will present the production procedure and quality control (QC) testing system for the powerboards to be installed on ITk Strip barrel modules. During production, about 150 powerboards will be produced every week. Each powerboard will need to pass QC tests before they are assembled to module. The QC tests include thermal cycling between -35 °C and 40 °C, soak test (continuous running of DC-DC converter at high load at 20 °C), and basic functionality and characterization electrical tests of the low voltage (LV), high voltage (HV), and monitoring functions of the powerboard. A custom QC test system is described, which is based on a reusable PCB (active board) with all testing circuits, a one-time powerboard carrier card, and a Z-turn SoC board which hosts and runs the testing program. The production procedure and QC test system has been tested with 400 powerboards during pre-production, and the system has been proven ready for production with the desired testing program, speed, safety, and cost. Performance and typical failures of powerboards observed during the QC test of pre-production powerboards is also presented.

47 OTHER INSTRUMENTATION↗

Terahertz metasurface quantum-cascade VECSELs: theory and performance

A longstanding challenge for terahertz quantum-cascade (QC) lasers is achieving both a high power and high-quality beam pattern, this is due in part due to their use of sub-wavelength metallic waveguides. Recently, the vertical-external-cavity surface-emitting laser (VECSEL) concept was demonstrated for the first time in the terahertz range and for a QC-laser. This is enabled by the development of an amplifying metasurface reflector capable of coupling incident free-space THz radiation to the QC-laser material such that it is amplified and re-radiated. The THz metasurface QC-VECSEL initiates a new approach for making QC-lasers with high power and excellent beam pattern. Furthermore, the ability to engineer the electromagnetic phase, amplitude, and polarization response of the metasurface enables lasers with new functionality. Our article provides an overview of the fundamental theory, design considerations, and recent results for high-performance THz QC-VECSELs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

MO-AB-210-01: Ultrasound Imaging and Therapy-Hands On Workshop

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

MO-AB-210-02: Ultrasound Imaging and Therapy-Hands On Workshop

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

MO-AB-210-03: Workshop [ Advancements in high intensity focused ultrasound ]

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

Identification of Glutaminyl Cyclase Genes Involved in Pyroglutamate Modification of Fungal Lignocellulolytic Enzymes

The breakdown of plant biomass to simple sugars is essential for the production of second-generation biofuels and high-value bioproducts. Currently, enzymes produced from filamentous fungi are used for deconstructing plant cell wall polysaccharides into fermentable sugars for biorefinery applications. A post-translational N-terminal pyroglutamate modification observed in some of these enzymes occurs when N-terminal glutamine or glutamate is cyclized to form a five-membered ring. This modification has been shown to confer resistance to thermal denaturation for CBH-1 and EG-1 cellulases. In mammalian cells, the formation of pyroglutamate is catalyzed by glutaminyl cyclases. Using the model filamentous fungus Neurospora crassa , we identified two genes ( qc-1 and qc-2 ) that encode proteins homologous to mammalian glutaminyl cyclases. We show that qc-1 and qc-2 are essential for catalyzing the formation of an N-terminal pyroglutamate on CBH-1 and GH5-1. CBH-1 and GH5-1 produced in a Δqc-1 Δqc-2 mutant, and thus lacking the N-terminal pyroglutamate modification, showed greater sensitivity to thermal denaturation, and for GH5-1, susceptibility to proteolytic cleavage. QC-1 and QC-2 are endoplasmic reticulum (ER)-localized proteins. The pyroglutamate modification is predicted to occur in a number of additional fungal proteins that have diverse functions. The identification of glutaminyl cyclases in fungi may have implications for production of lignocellulolytic enzymes, heterologous expression, and biotechnological applications revolving around protein stability.

59 BASIC BIOLOGICAL SCIENCES↗