Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process Sample Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

The International Atomic Energy Agency (IAEA) relies upon laboratory analysis of environmental samples (typically referred to as “swipes”) collected during on-site inspections of safeguarded facilities to support the detection and deterrence of undeclared activities. Unfortunately, chemical processing and assay of the samples is slow and expensive. A rapid, effective, and simple extraction process and analysis method is needed to provide certified results with improved timeliness at reduced costs (principally in the form of reduced labor), while maintaining or improving sensitivity and efficacy. To address these safeguard needs the Pacific Northwest National Laboratory (PNNL) explored and demonstrated improved methods for environmental sample (ES) analysis. Improvements for both bulk and particle analysis were explored. To facilitate continuity and adoption, the new sampling materials and processing methods will be compatible with existing IAEA protocols for ES analysis. PNNL collaborated with Oak Ridge National Laboratory (ORNL), which performed independent validation of the new bulk analysis methods and compared performance to traditional IAEA’s Network of Analytical Laboratories (NWAL) protocol. ORNL efforts are reported separately. This report describes PNNL’s FY 2016 progress, which was focused on analytical application supporting environmental monitoring of uranium enrichment plants and nuclear fuel processing. In the future the technology could be applied to other safeguard applications and analytes related to fuel manufacturing, reprocessing, etc. PNNL’s FY 2016 efforts were broken into two tasks and a summary of progress, accomplishments and highlights are provided below. Principal progress and accomplishments on Task 1, Optimize Materials and Methods for ICP-MS Environmental Sample Analysis, are listed below. • Completed initial procedure for rapid uranium extraction from ES swipes based upon carbonate-peroxide chemistry (delivered to ORNL for evaluation). • Explored improvements to carbonate-peroxide rapid uranium extraction chemistry. • Evaluated new sampling materials and methods (in collaboration with ORNL). • Demonstrated successful ES extractions from standard and novel swipes for a wide range uranium compounds of interest including UO 2 F 2 and UO 2 (NO 3 ) 2 , U 3 O 8 and uranium ore concentrate. • Completed initial discussions with commercial suppliers of PTFE swipe materials. • Submitted one manuscript for publication. Two additional drafts are being prepared. Principal progress and accomplishments on Task 2, Optimize Materials and Methods for Direct SIMS Environmental Sample Analysis, are listed below. • Designed a SIMS swipe sample holder that retrofits into existing equipment and provides simple, effective, and rapid mounting of ES samples for direct assay while enabling automation and laboratory integration. • Identified preferred conductive sampling materials with better performance characteristics. • Ran samples on the new PNNL NWAL equivalent Cameca 1280 SIMS system. • Obtained excellent agreement between isotopic ratios for certified materials and direct SIMS assay of very low levels of LEU and HEU UO 2 F 2 particles on carbon fiber sampling material. Sample activities range from 1 to 500 CPM (uranium mass on sample is dependent upon specific isotope ratio but is frequently in the subnanogram range). • Found that the presence of the UF molecular ions, as measured by SIMS, provides chemical information about the particle that is separate from the uranium isotopics and strongly suggests that those particles originated from an UF6 enrichment activity. • Submitted one manuscript for publication. Another manuscript is in preparation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Real Time, In-line Monitoring of Hanford Tank Wastes - Year 1 Report

The team comprised of students, postdocs, early, mid and senior career scientists from Los Alamos National Laboratory, Savanah River National Laboratory, Georgia Tech and Florida International University, with the guidance of H2C, is developing a suite of in-line instruments for the Hanford high level waste (HLW) and low active waste (LAW) processes to provide near-real-time analysis of waste form physical properties and composition. The work builds on results from the recent DOE-ORP, EM Technology Development and other projects that demonstrated promise for the use of real-time in-line monitoring (RTIM) to measure chemical compositions of slurries of up to 20 weight % solids. The goal is for this instrument suite is to substantially reduce the need for sampling for process control. Sample waste, exposure associated with sample analysis, and the demand for an external laboratory facility would be greatly reduced. The throughput of waste treatment systems would be improved by elimination of the downtime caused by waiting for sample results. This translates into reduced process storage as process knowledge will be continuously updated in near-real-time. These breakthrough technologies would significantly reduce the life cycle cost and accelerate the schedule for the Hanford tank waste mission.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimation of process steady state with autoregressive models and Bayesian inference

To improve efficiency, separations engineers will typically design process circuits containing recirculating streams, which mix one or more of the process outputs with the feed material. Doing so can improve efficiency, but will cause a delay in the system reaching steady state conditions until the recirculating load mass flows stabilize. In testing separation circuits, engineers will often test a variety of factors and complete an analysis from sample results. Knowledge of if a process is at steady state, as well as the steady state conditions of a process, is essential for a valid techno-economic analysis. However, the definition of process steady state is often poorly defined, or does not include uncertainty quantification. If the performance of a process operating under two different sets of conditions are compared, an engineer who does not test for steady state or quantify steady state conditions risks producing a faulty analysis. In this work, a Bayesian statistical method for testing if all streams are at steady state is further motivated and then derived. Then after testing for steady state, the same model is used with a prior distribution that enforces a steady state assumption to estimate steady state conditions. Further, these methods were validated in a solvent extraction pilot plant where steady state conditions for all outflows were inferred with uncertainty quantification. Analysis is completed with functions available to the reader as part of the BayesMassBal (V 1.1.0) software package written in R.

01 COAL, LIGNITE, AND PEAT↗

Radiochemical capabilities for astrophysics experiments at the national ignition facility

The Nuclear and Radiochemistry Group at Lawrence Livermore National Laboratory (LLNL) has developed a suite of diagnostics and techniques that can be used for astrophysics experiments at the National Ignition Facility (NIF). Capabilities have been developed to add material to the outside of NIF hohlraum assemblies as well as to the interior of NIF target capsules or the fill gas. The ability to place very small amounts of material close to the NIF target enables activation with very large, short-pulse neutron fluxes. The Solid Radiochemistry Diagnostic can be used to collect solid debris from a NIF shot within 2 h of the execution of a shot, and this can be analyzed for radioactive signatures with or without post-shot chemical processing. The Radiochemical Analysis of Gaseous Samples diagnostic system can be used to collect gaseous products produced during a NIF shot. Capsule doping and radiochemical analysis capabilities at NIF will be discussed. The application of these techniques to astrophysical measurements will be discussed as well as some preliminary results.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Testing of a Microfluidic Sampling System for High Temperature Electrochemical MC&A

This report describes the preliminary validation of a high-temperature microfluidic chip system for sampling of electrochemical process salt. Electroanalytical and spectroscopic techniques are attractive candidates for improvement through high-throughput sample analysis via miniaturization. Further, microfluidic chip systems are amenable to micro-scale chemical processing such as rapid, automated sample purification to improve sensor performance. The microfluidic chip was tested to determine the feasibility of the system for high temperature applications and conditions under which microfluidic systems can be used to generate salt droplets at process temperature to support development of material balance and control systems in a used fuel treatment facility. In FY13, the project focused on testing a quartz microchip device with molten salts at near process temperatures. The equipment was installed in glove box and tested up to 400°C using commercial thermal transfer fluids as the carrier phase. Preliminary tests were carried out with a low-melting halide salt to initially characterize the properties of this novel liquid-liquid system and to investigate the operating regimes for inducing droplet flow within candidate carrier fluids. Initial results show that the concept is viable for high temperature sampling but further development is required to optimize the system to operate with process relevant molten salts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Single-Cell Metabolomics with Rapid Determination of Chemical Formulas from Isotopic Fine Structures

Metabolomic measurements can provide functional readouts of cellular states and phenotypes. Here, we present a protocol for single-cell metabolomics that permits direct untargeted detection of a broad number of metabolites under ambient conditions, without the need for sample processing, and with high confidence in the discovery and identification of the molecular formulas for detected metabolites. This protocol describes combining fiber-based laser ablation electrospray ionization (f-LAESI) with a 21 Tesla Fourier transform ion cyclotron resonance mass spectrometer (21T-FTICR-MS) to obtain high confidence molecular formula information about detected metabolites. The f-LAESI source utilizes mid-infrared laser ablation through a sharp optical fiber tip, affording direct ambient analysis of cells without the need for sample processing. Using the 21T-FTICR-MS as a mass analyzer enabled measurement of the isotopic fine structure (IFS) for numerous metabolites simultaneously from single cells, and the IFSs were in turn computationally processed to rapidly determine the corresponding elemental compositions. This metabolomics technique complements other single cell omics measurement methods, helping to resolve complex molecular interactions that take place within cells unattainable from single cell transcriptomic and proteomics methods.

mass spectrometry, FTICR, FTMS, ultrahigh mass res↗

Soil Gas Sample Handling: Evaluation of Water Removal and Sample Ganging

Soil gas sampling is currently conducted in support of Nuclear Test Ban treaty verification. Soil gas samples are collected and analyzed for isotopes of interest. Some issues that can impact sampling and analysis of these samples are excess moisture and sample processing time. Here we discuss three potential improvements to the current sampling protocol; a desiccant for water removal, use of molecular sieve to remove CO 2 from the sample during collection, and a ganging manifold to allow composite analysis of multiple samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Open Specy 1.0: Automated (Hyper)spectroscopy for Microplastics

Microplastic spectral analysis is one of the most time-consuming processes in studying microplastic pollution, often requiring days per sample. Researchers are transitioning to automated batch and hyperspectral image analysis techniques to enhance efficiency. Open Specy, initially aimed at manual single-spectrum analysis, has now integrated automated methods. This updated version, Open Specy 1.0, introduces several new features, including two algorithms for automated processing (smoothing and particle compression), an extensive library containing over 40,000 open-source Raman and FTIR spectra, and two machine learning classifiers (logistic regression and k medoids) developed from this library. Furthermore, it includes a revamped user interface, an R package, and a benchmark data set for testing future advancements in automated techniques. Researchers evaluated various configurations for hyperspectral smoothing, particle identification, compression, and splitting, to achieve combined recovery rates between 50 and 150% particle counts, identities, and sizes with a coefficient of variation (CV) of less than 40% (the accredited standard). Mean absorbance times the standard deviation provided a consistent particle identification. Hyperspectral smoothing led to a 96% combined recovery rate and reduced variability (CV = 38%) compared to the 86% recovery (CV = 83%) of nonsmoothed controls. Additionally, compressing spectra for particles was significantly faster (>3x) and showed similar accuracy but with reduced variability than processing each pixel individually. Key challenges persist in automating spectral analysis, particularly in refining particle splitting algorithms, and improving identification routines to minimize false positives and negatives. In conclusion, new methods in sample preparation for better stabilization and dispersion of particles could overcome some of these issues.

13 HYDRO ENERGY↗

Human Liver Epithelium Response to HCoV-229E Infection Epigenomics (ACS-DP4)

The purpose of this experiment was to evaluate how wild-type Human coronavirus strain 229E (HCoV-229E) infection alters chromatin accessibility in infected cells only. Sample data was obtained for mock and infected (standard and UV-inactivated) immortalized human liver cells (HuH-7) and collected 24 hrs. post infection. Samples were processed using assay for transposase-accessible chromatin using high-throughput sequencing (ATAC-Seq) and generated bar coded library samples were evaluated for RNA sequencing (RNA-Seq) expression analysis. Processed ATAC-Seq datasets are openly accessible from the download button and contain secondary processed RNA-Seq results files and supporting metadata materials. Data download includes a sample naming key, infection titer metadata, normalized counts, and relevant computational source code information supporting data transparency and reuse.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of Thermo-Mechanical Processes in the 110 K Phase of Bi{sub 2−x}Pb{sub x}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub y} (x = 0.3–0.6) Superconductors

In this study, the effects of thermo-mechanical processes on the 110 K phase of Bi{sub 2−x}Pb{sub x}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub y} (x = 0.3–0.6) superconductors have been studied. In order to investigate the effects of thermo-mechanical processes, the samples were prepared in three groups with different sintering temperatures having intermediate grindings and pressings. The superconducting and structural properties of BPSCCO system were characterized by R(T), χ(T), and J{sub c} measurements; XRD; and SEM analysis. The thermo-mechanical processes were investigated to explain how they affect T{sub c} and metallic properties of the samples. According to the analysis, we obtained that the 110 K phase of BPSCCO samples was significantly affected by these thermal and mechanical processes. The preparation conditions were optimized in order to obtain a BPSCCO system having dominant phase of 110 K with the superior superconducting properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Carrier-assisted One-pot Sample Preparation for Targeted Proteomics Analysis of Small Numbers of Human Cells

Protein analysis of small numbers of human cells is primarily achieved by targeted proteomics with antibody-based immunoassays, which have inherent limitations (e.g., low multiplex and unavailability of antibodies for new proteins). Mass spectrometry (MS)-based targeted proteomics has emerged as an alternative because it is antibody-free, high multiplex, and has high specificity and quantitation accuracy. Recent advances in MS instrumentation make MS-based targeted proteomics possible for multiplexed quantification of highly abundant proteins in single cells. However, there is a technical challenge for effective processing of single cells with minimal sample loss for MS analysis. To address this issue, we have recently developed a convenient protein carrier-assisted one-pot sample preparation coupled with liquid chromatography (LC) - selected reaction monitoring (SRM) termed cLC-SRM for targeted proteomics analysis of small numbers of human cells. This method capitalizes on using the combined excessive exogenous protein as a carrier and low-volume one-pot processing to greatly reduce surface adsorption losses as well as high-specificity LC-SRM to effectively address the increased dynamic concentration range due to the addition of exogeneous carrier protein. Its utility has been demonstrated by accurate quantification of most moderately abundant proteins in small numbers of cells (e.g., 10-100 cells) and highly abundant proteins in single cells. The easy-to-implement features and no need for specific devices make this method readily accessible to most proteomics laboratories. In this study, we have provided a detailed protocol for cLC-SRM analysis of small numbers of human cells including cell sorting, cell lysis and digestion, LC-SRM analysis, and data analysis. Further improvements in detection sensitivity and sample throughput are needed towards targeted single-cell proteomics analysis. We anticipate that cLC-SRM will be broadly applied to biomedical research and systems biology with the potential of facilitating precision medicine.

60 APPLIED LIFE SCIENCES↗

Real-time elemental analysis of liquids for process monitoring using laser-induced breakdown spectroscopy with a liquid wheel sampling approach

This article presents an engineered sampling system that used a rotating wheel to form a thin liquid layer, permitting the use of laser-induced breakdown spectroscopy (LIBS) for in situ, real-time elemental impurity quantification during liquid processing. The sampling approach was demonstrated on eight elements from across the periodic table (Na, Al, K, Ca, Ti, Sr, Mo, and Yb). Univariate and multivariate calibrations were presented for each element. The average value for percent root mean square errors of cross-validation for the multivariate models was 3.64%, highlighting the method's strong prediction accuracy. Additionally, the limits of detection for each analyte were estimated from their univariate models: Na = 0.0532, Al = 18.5, K = 0.105, Ca = 0.273, Ti = 67.7, Sr = 0.640, Mo = 22.4, and Yb = 22.9 μg mL –1 . Finally, a test in which multivariate models were used to monitor a liquid system for 80 min was performed to investigate the real-time monitoring capabilities of this liquid LIBS sampling approach. Rigorous measurements were performed to effectively predict the absence and concentrations of multiple analytes as they were spiked and diluted. This demonstration showed the feasibility of using LIBS for real-time liquid quantification models with estimated precision ≤ 8.1%. Finally, the limitations of this approach and potential future improvements are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Internship Progress Summary: Fall 2016

This fall I had the opportunity to work at Los Alamos National Laboratory for the Technology Applications engineering group. I assisted two main projects during my appointment, both related to the Lab’s mission statement: “To solve national security challenges through scientific excellence.” My first project, a thermal source transfer unit, involved skills such as mechanical design, heat transfer simulation, and design analysis. The goal was to create a container that could protect a heat source and regulate its temperature during transit. I generated several designs, performed heat transfer simulations, and chose a design for prototyping. The second project was a soil drying unit for use in post blast sample analysis. To ensure fast and accurate sample processing, agents in the field wanted a system that could process wet dirt and turn it into dry powder. We designed a system of commercially available parts, and we tested the systems to determine the best methods and processes.

42 ENGINEERING↗

A Handheld Medical Diagnostic Device for Harsh Environments

Medical diagnostic capabilities for extreme environments, are currently limited in nature to single marker type assays. We propose to develop a handheld device for medical diagnostics in extreme environments that provide sensitive and specific detection of biomarkers with an emphasis initially on radiation exposure. Such a device will have multiple uses, and will be easily adaptable to many applications. For example, first responders, the battlefield, in low resource settings in developing countries facing emerging disease outbreaks, and during long-duration space flights. To this end, we will develop highly adaptable microfluidic devices (cards) for profiling different biomarkers with an emphasis on those related to radiation exposure. We will leverage the previous centrifugal separator work from LLNL and Sandia National Laboratory. The radiation exposure biomarker work at LLNL will provide a biological platform for demonstrating the utility of the device. We will develop a fluidic system using a pump-less mechanical method (centrifugal) to move, control, order and layer fluids in the platform. This decreases complexity, while enabling simultaneous cell separation and plasma generation for two uses: the first is differential blood cell counts and the second is biomarker assay panels. This work will be accomplished in three Aims: Aim 1) Test multiplex microfluidic cards and integrated reader. Aim 2) Demonstrate system capabilities to take and process blood samples for multi-endpoint analysis. Aim 3) Test multiplex detection based on measuring differential blood cell counts, while measuring plasma protein biomarkers. The proposed work addresses the mission research challenge of chemical and biological countermeasure in that our work aims to provide new research capabilities to respond to man-made or natural outbreaks of pandemic diseases in particular in low resource and triage environments.

60 APPLIED LIFE SCIENCES↗

Geochemical Changes in Response to CO 2 Injection in a CO 2 -EOR Complex in Northern Michigan

The overall purpose of the geochemical monitoring program under Midwestern Regional Carbon Sequestration Partnership (MRCSP) is to use stable and radiogenic isotope geochemistry in concert with analysis of general geochemical parameters of fluids and gases and analysis of core samples to determine geochemical processes occurring in the reef structure because of CO 2 injection..

54 ENVIRONMENTAL SCIENCES↗

Geochemical Changes in Response to CO 2 Injection in a CO 2 -EOR Complex in Northern Michigan (Volume II.1)

The Midwest Regional Carbon Sequestration Partnership (MRCSP) was founded in 2003 as part of the U.S. Department of Energy’s (DOE’s) Regional Carbon Sequestration Partnership initiative. Since its founding, MRCSP has made significant strides toward making CCUS a viable option for states in the region. The public/private consortium, funded through the DOE Regional Carbon Sequestration Initiative, brings together nearly 40 industry partners and 10 states. Battelle, as the project lead, oversees research, development and operations and coordinates activities among the partners. The incremental, phased approach has built a valuable knowledge base for the industry and paved the way for commercial-scale adoption of CCUS technologies. From 2008 to 2020, MRCSP Phase III focused on the development of large-scale injection projects. This report is part of a series of reports prepared under the Midwestern Regional Carbon Sequestration Partnership (MRCSP) Phase III (Development Phase). These reports summarize and detail the findings of the work conducted under the Phase III project. The report describes the geochemical monitoring program under MRCSP to use stable and radiogenic isotope geochemistry in concert with analysis of general geochemical parameters of fluids and gases and analysis of core samples to determine geochemical processes occurring in the reef structure because of CO 2 injection. Specifically, brine and gas samples were collected and analyzed to determine changes occurring between reefs prior to and following CO 2 injection. The analytical results for general geochemical parameters were modeled with chemical equilibrium models to determine if the injection of CO 2 resulted in the mineral dissolution or precipitation. Finally, core samples were collected and analyzed to determine if there was evidence of dissolution features or mineral precipitation.

01 COAL, LIGNITE, AND PEAT↗

Automatic Analyte-Ion Recognition and Background Removal for Ambient Mass-Spectrometric Data Based on Cross-Correlation

Ambient mass spectrometry is a powerful approach for rapid, high-throughput, and direct sample analysis. Due to the open-air desorption and ionization processes, random fluctuations of ambient conditions can lead to large variances in mass-spectral signals over time. The mass-spectral data also can be further complicated due to multiple analytes present in the sample, background-ion signals stemming from the desorption/ionization source itself, and other laboratory-specific conditions (e.g., ambient laboratory air, nearby hardware). Thus, background removal and analyte-ion recognition can be quite difficult, particularly in non-targeted analyses. Here, we demonstrate the use of a cross-correlation-based approach to exploit chemical information encoded in the time domain to group/categorize mass-spectral peaks from a single analysis dataset. Ions that originate from ambient (or other) background species were readily flagged and removed from spectra; the result was a decrease in mass-spectral complexity by over 70% due to the removal of these background ions. Meanwhile, analyte ions were differentiated and categorized based on their time-domain profiles. With sufficient mass resolving-power and mass-spectral acquisition rate, isolated mass spectra containing ions from the same species in a sample could be extracted, leading to a reduction in mass-spectral complexity by more than 98% in some cases. The cross-correlation approach was tested with different ionization sources as well as reproducible and irreproducible sample introduction. Software built in-house enabled fully automated data processing, which can be performed within a few seconds. Ultimately, this approach provides an additional dimension of analyte separation in ambient mass-spectrometric analyses with information that is already recorded throughout the analysis. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗