Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Fe Kα XANES, Fe Kβ HERFD XANES and EPMA flank method determinations of the oxidation state of Fe in garnet

The ferric to total iron ratios (Fe 3+ /ΣFe) of garnets can be paired with thermodynamic mineral activity models to quantify the oxygen fugacity of garnet-bearing rocks. However, techniques with a high analytical and spatial resolution are necessary to distinguish differences in garnet Fe 3+ /ΣFe ratios at the percent level and to accurately measure garnets that are zoned or contain inclusions. We acquired conventional Fe Kα and high-resolution energy fluorescence detection (HERFD) Fe Kβ X-ray absorption near edge structure (XANES) spectra and electron microprobe flank method analyses on a suite of 27 peridotitic and eclogitic garnets with Fe 3+ /ΣFe ratios previously determined by Mössbauer spectroscopy to evaluate the precision of each technique. We examined variations in the energy and intensity of three XANES spectral features as a function of Fe 3+ /ΣFe ratios: 1) the intensity ratio of two-post edge features (I-ratio; Fe Kα only); 2) the energy of the Fe edge at 90% normalized intensity (E 0.9 ; Fe Kα only) and 3) the pre-edge centroid energy (Fe Kα and HERFD Fe Kβ). In accordance with previous work, we find the energies of garnet pre-edge centroids are relatively insensitive to Fe 3+ /ΣFe ratios. The I-ratios of peridotitic and eclogitic garnets are offset from each other at low Fe 3+ /ΣFe ratios (≤0.13); I-ratio garnet XANES calibrations are composition-specific. The E 0.9 feature is independent of garnet major element composition in spectra that have been corrected for the effects of self-absorption. We produce two Fe Kα garnet XANES calibrations based on variations in the E0.9 feature; one calibration with all garnet reference materials included (Fe 3+ /ΣFe up to 1.0; “all garnet calibration”) and another calibration specific to garnets with low Fe 3+ /ΣFe ratios (“low ferric calibration”). Fe 3+ /ΣFe ratios calculated from the mean of up to 25 flank method measurements on eight garnet reference materials fall within 4% absolute of a one-to-one correlation with Fe 3+ /ΣFe ratios measured by Mössbauer. The standard error of the mean Fe 3+ /ΣFe ratio calculated from flank method approaches the Mössbauer-determined Fe 3+ /ΣFe ratio within estimated error (3%) after three analyses. Flank method precision is enhanced at higher beam current; however, the precision of the flank method does not approach the precision of XANES under any microprobe analytical condition tested here. Garnet reference materials detailed here are available by request to the Smithsonian Institution.

58 GEOSCIENCES↗

Calorimetric Low-Temperature Detectors for X-Ray Spectroscopy on Trapped Highly-Charged Heavy Ions

The application of Calorimetric Low-Temperature Detectors (CLTDs) has been proposed at the Heavy-Ion TRAP facility HITRAP which is currently being installed at the Helmholtz Research Center for Heavy Ion Research GSI. This cold ion trap setup will allow the investigation of X-rays from ions practically at rest, for which the excellent energy resolution of CLTDs can be used to its full advantage. However, the relatively low intensities at HITRAP demand larger solid angles and an optimized cryogenic setup. The influence of external magnetic fields has to be taken into account. CLTDs will also be a substantial part of the instrumental equipment at the future Facility for Antiproton and Heavy Ion Research (FAIR), for which a wide variety of high-precision X-ray spectroscopy experiments has been proposed. This contribution will give an overview on the chances and challenges for the application of CLTDs at HITRAP as well as perspectives for future experiments at the FAIR facility.

Kilbourne, Caroline↗

Transfer-Free Synthesis of Atomically Precise Graphene Nanoribbons on Insulating Substrates

The rational bottom-up synthesis of graphene nanoribbons (GNRs) provides atomically precise control of widths and edges that give rise to a wide range of electronic properties promising for electronic devices such as field-effect transistors (FETs). Since the bottom-up synthesis commonly takes place on catalytic metallic surfaces, the integration of GNRs into such devices requires their transfer onto insulating substrates, which remains one of the bottlenecks in the development of GNR-based electronics. Herein, we report on a method for the transfer-free placement of GNRs on insulators. This involves growing GNRs on a gold film deposited onto an insulating layer followed by gentle wet etching of the gold, which leaves the nanoribbons to settle in place on the underlying insulating substrate. Scanning tunneling microscopy and Raman spectroscopy confirm that atomically precise GNRs of high density uniformly grow on the gold films deposited onto SiO 2 /Si substrates and remain structurally intact after the etching process. We have also demonstrated transfer-free fabrication of ultrashort channel GNR FETs using this process. A very important aspect of the present work is that the method can scale up well to 12 in. wafers, which is extremely difficult for previous techniques. Our work here thus represents an important step toward large-scale integration of GNRs into electronic devices.

36 MATERIALS SCIENCE↗

Probing fundamental constant oscillation in the Galactic Center with S-Star Spectroscopy

Astrophysical spectroscopy provides a powerful probe of spacetime variations of fundamental constants, as atomic and ionic emission and absorption lines depend sensitively on the fine-structure constant. In particular, coherent temporal oscillations induced by an ultralight scalar background produce characteristic, time-resolved signatures that can be robustly disentangled from intrinsic variability. In the Galactic Center, such scalar backgrounds can be substantially enhanced, either through the formation of dense scalar clouds powered by black hole rotational energy extraction or as ultralight scalar dark matter forming a soliton-like core. These scalar configurations generically induce oscillations of the fine-structure constant, with periods set by the scalar mass and spatial profiles determined by the scalar wavefunction and its coupling to the electromagnetic sector. We show that precise, time-resolved spectroscopy of S-stars orbiting the supermassive black hole Sgr A^* provides a sensitive test of these effects, enabling constraints on quadratic scalar-photon couplings in the exceptionally high boson-density environment of the Galactic Center.

Bai, Zhaoyu [Weizmann Inst.] (ORCID:00000002075815↗

Direct Imaging and Spectroscopy of Exoplanetary Systems with the JWST Early Release Science Program

The direct characterization of exoplanetary systems with high contrast imaging is among the highest priorities for the broader exoplanet community. As large space missions will be necessary for detecting and characterizing exo-Earth twins, developing the techniques and technology for direct imaging of exoplanets is a driving focus for the community. For the first time, JWST will directly observe extrasolar planets at mid-infrared wavelengths beyond 5 μm, deliver detailed spectroscopy revealing much more precise chemical abundances and atmospheric conditions, and provide sensitivity to analogs of our solar system ice-giant planets at wide orbital separations, an entirely new class of exoplanet. However, in order to maximise the scientific output over the lifetime of the mission, an exquisite understanding of the instrumental performance of JWST is needed as early in the mission as possible. In this paper, we describe our 55-hour Early Release Science Program that will utilize all four JWST instruments to extend the characterisation of planetary mass companions to ∼15-20 μm as well as image a circumstellar disk in the mid-infrared with unprecedented sensitivity. Our program will also assess the performance of the observatory in the key modes expected to be commonly used for exoplanet direct imaging and spectroscopy, optimize data calibration and processing, and generate representative datasets that will enable a broad user base to effectively plan for general observing programs in future cycles.

Michael W McElwain↗

Beam test performance of AstroPix sensor with 120 GeV protons

AstroPix is a High-Voltage CMOS Monolithic Active Pixel Sensor (HV-CMOS MAPS) developed for precision gamma-ray imaging and spectroscopy in the medium-energy regime, as well as for precise shower imaging and tracking in the Barrel Imaging Calorimeter (BIC) of the Electron Proton/Ion Collider (ePIC) detector at the future Electron–Ion Collider (EIC). We present beam test results of the AstroPix_v3 sensor using a 120 GeV proton beam at the Fermilab Test Beam Facility (FTBF), performed as part of the broader experimental campaign for the BIC prototype calorimeter. The sensor’s 500 µm pixel pitch enabled precise measurement of the beam profile, providing important information for the calorimeter performance studies. Using the measured 120 GeV proton data, we measure the energy deposit of minimum ionizing particles (MIP) and use them to extract the corresponding effective depletion depth at a single bias voltage of −150 V .

AstroPix↗

The large-area hybrid-optics CLAS12 RICH: First years of data-taking

The CLAS12 deep-inelastic scattering experiment at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab conjugates luminosity and wide acceptance to study the 3D nucleon structure in the yet poorly explored valence region, and to perform precision measurements in hadron spectroscopy. A large area ring-imaging Cherenkov detector has been designed to achieve the required hadron identification in the momentum range from 3 GeV/c to 8 GeV/c, with the kaon rate about one order of magnitude lower than the rate of pions and protons. The adopted solution comprises aerogel radiator and composite mirrors in a novel hybrid optics design, where either direct or reflected light could be imaged in a high-packed and high-segmented photon detector. The first RICH module was assembled during the second half of 2017 and installed at the beginning of January 2018, in time for the start of the experiment. The second RICH module, planned with the goal to be ready for the beginning of the operation with polarized targets, has been timely built despite the complications caused by the pandemic crisis and successfully installed in June 2022. Finally, the detector performance is here discussed with emphasis on the operation and stability during the data-taking, calibration and alignment procedures, reconstruction and pattern recognition algorithms, and particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discovery of TOI-1260d and the characterization of the multiplanet system

ABSTRACT We report the discovery of a third planet transiting the star TOI-1260, previously known to host two transiting sub-Neptune planets with orbital periods of 3.127 and 7.493 d, respectively. The nature of the third transiting planet with a 16.6-d orbit is supported by ground-based follow-up observations, including time-series photometry, high-angular resolution images, spectroscopy, and archival imagery. Precise photometric monitoring with CHEOPS allows to improve the constraints on the parameters of the system, improving our knowledge on their composition. The improved radii of TOI-1260b and TOI-1260c are $2.36 \pm 0.06 \rm R_{\oplus }$, $2.82 \pm 0.08 \rm R_{\oplus }$, respectively while the newly discovered third planet has a radius of $3.09 \pm 0.09 \rm R_{\oplus }$. The radius uncertainties are in the range of 3 per cent, allowing a precise interpretation of the interior structure of the three planets. Our planet interior composition model suggests that all three planets in the TOI-1260 system contains some fraction of gas. The innermost planet TOI-1260b has most likely lost all of its primordial hydrogen-dominated envelope. Planets c and d were also likely to have experienced significant loss of atmospheric through escape, but to a lesser extent compared to planet b.

Lam, K. W. F. (ORCID:0000000299106088)↗

Real-time estimators for scattering observables: A full account of finite-volume errors for quantum simulation

The real-time correlators of quantum field theories can be directly probed through new approaches to simulation, such as quantum computing and tensor networks. This provides a new framework for computing scattering observables in lattice formulations of strongly interacting theories, such as lattice quantum chromodynamics. In this paper, we prove that the proposal of real-time estimators of scattering observables is universally applicable to all scattering observables of gapped quantum field theories. All finite-volume errors are exponentially suppressed, and the rate of this suppression is controlled by the regulator considered, namely, a displacement of the spectrum of the theory into the complex plane. A partial restoration of Lorentz symmetry by averaging over different boosts gives an additional suppression of finite volume errors. Our results also apply to the simulation of wave packet scattering, where a similar averaging is performed to construct the wave packets that regulate the finite volume effects. This result represents a necessary key step toward determining a broad class of scattering observables via quantum computing that are currently inaccessible via classical computing. Such observables are relevant for various applications, including hadron spectroscopy, hadron structure, and precision tests of the Standard Model. We also comment on potential applications of our results to traditional computational schemes.

Burbano, Ivan M. [University of California, Berkel↗

Micro-fabricated mirrors with finesse exceeding one million

The Fabry–Perot resonator is one of the most widely used optical devices, enabling scientific and technological breakthroughs in diverse fields including cavity quantum electrodynamics, optical clocks, precision length metrology, and spectroscopy. Though resonator designs vary widely, all high-end applications benefit from mirrors with the lowest loss and highest finesse possible. Fabrication of the highest-finesse mirrors relies on centuries-old mechanical polishing techniques, which offer losses at the parts-per-million (ppm) level. However, no existing fabrication techniques are able to produce high-finesse resonators with the large range of mirror geometries needed for scalable quantum devices and next-generation compact atomic clocks. In this paper, we introduce a scalable approach to fabricate mirrors with ultrahigh finesse ( ≥ <#comment/> 10 6 ) and user-defined radius of curvature spanning of four orders of magnitude ( 10 − <#comment/> 4 − <#comment/> 10 0 m ). We employ photoresist reflow and reactive ion etching to shape and transfer mirror templates onto a substrate while maintaining sub-Angstrom roughness. This substrate is coated with a dielectric stack and used to create arrays of compact Fabry–Perot resonators with finesse values as high as 1.3 million and measured excess loss < <#comment/> 1 p p m . Optical ringdown measurements of 43 devices across five substrates reveal that the fabricated cavity mirrors—with both small and large radii of curvature—produce an average coating-limited finesse of 1.05 million. This versatile approach opens the door to scalable fabrication of high-finesse miniaturized Fabry–Perot cavities needed for emerging quantum optics and frequency metrology technologies.

42 ENGINEERING↗

The JLab Eta Factory (JEF) experiment

The new experiment, JLab Eta Factory (JEF), in the experimental Hall D at Jefferson Lab will extend the physics potential of the GlueX detector beyond the main spectroscopy program and perform precision measurements of various ?(?)decays with emphasis on rare neutral modes. The physics program of the experiment spans from precision tests of low-energy QCD to search of gauge bosons in the mass range below 1 GeV coupling the SM sector to the dark sector. Photoproduction of highly boosted ?(?)mesons using a tagged photon beam, good detection of recoil proton and multi-photon final states will allow to suppress background and collect high-statistics data sample of ?mesons. All these provide many advantages over other ?(?)experiments. The JEF experiment requires to upgrade the inner part of the forward lead glass calorimeter of the GlueX detector with high-granularity, high-resolution lead tungstate PbWO4 scintillating crystals. The calorimeter insert is currently under construction at Jeffeson Lab. The detector will be ready to take data in 2024. An overview of the JEF project will be presented.

Somov, Alexander↗

Gas Stopper Developments for Improved Purity and Intensity of Low-Energy, Rare Isotope Ion Beams (Final Technical Report)

This final technical report summarizes the work of the Michigan State University (MSU) team supported by grant # DE-SC0021423 awarded by the Office of Nuclear Physics, Department of Energy. Objectives: The successful fulfillment of the FRIB science mission hinges on ensuring the availability of fast, stopped, and reaccelerated beams consisting of rare isotopes. This project's research and development focus was dedicated to supporting the advancement and creation of a cutting-edge linear gas stopper. The primary aim is to efficiently convert the high-intensity fast beams of rare isotopes provided by FRIB into high-quality, low-energy beams. These beams are essential for conducting stopped beam experiments or for subsequent reacceleration. The overarching goal is to advance technology, aiming to increase the beam rate capability of the linear gas stopper for medium-to-heavy-mass rare isotopes by more than tenfold compared to the currently most effective gas stopper in operation, and to improve the purity of the delivered beams. Project Description: The existing technology employed in gas stopping devices designed for low-energy, rare-isotope beams presents limitations in both the purity of extracted beams and the intensities of injected beams. These limitations are incompatible with the requirements of the recently commissioned rare isotope beam facility, FRIB. Our research and development efforts, aligned with the previously outlined objectives, focused on addressing the most critical aspects for enhancing beam-rate capability and purity. Specifically, advanced particle-in-cell simulations were developed and integrated into a simulation pipeline to explore the efficacy of multi-layer RF carpets on increasing ion transport efficiency with high incoming beam rates that generate space charge fields which can limit it. We also explored the possibility of using a collision-induced-dissociation (CID) gas cell to break up molecular contaminant ions that are generated during the stopping process. A prototype CID gas cell was constructed and tested with beams from an offline ion source, validating the concept with the successful demonstration of breaking of molecular ions. The outcome of this research enabled the formulation a conceptual design for a next-generation linear gas stopping device specifically tailored for FRIB. This device is envisioned to deliver rare-isotope-ion beams at a rate of 10 8 particles per second or higher, accompanied by advancements in purity. Methods employed: This project leverages advancements in technologies initially designed for the Advanced Cryogenic Gas Stopper (ACGS), the current state-of-the-art linear gas stopper, through the use of new simulations and beam purification via collision-induced-dissociation. The methods include: 1. Development of a prototype low-energy, low-pressure CID gas stopper. This prototype features a thin, approximately 20 nm, Si 3 N 4 entrance window designed for dissociating stable and rare-isotope molecular ions. The goal is to enhance beam purification and overall efficiency. 2. Creation of Particle-in-cell (PIC) simulations to assess the advantages of multi-layer RF carpets and multi-point extraction for ion transport efficiency. These simulations rely on the 3DCylPIC package, specifically designed for studying devices of this nature. The goal is to quantify and mitigate ion transport losses due to space charge generated in the stopping process of large numbers of ions. 3. Perform ion transport simulations across an RF carpet using an 8-phase travelling wave and evaluate its performance. Compared to the 4-phase RF carpets used in ACGS, the 8-phase carpets will double the wavelength of the generated traveling wave allowing for larger maximum RF amplitudes that could result in improved ion transport efficiency for high-intensity incoming beams when large space charge fields are present. Impact: Tackling the primary challenges associated with transforming high-energy projectile fragment beams into low-energy beams—specifically, addressing efficiency and purity—holds significant promise for advancing FRIB science. This advancement will particularly impact precision mass measurements, laser spectroscopy of short-lived nuclei, and studies in astrophysics and nuclear reactions using reaccelerated beams. These domains play a crucial role in addressing key questions outlined in the 2023 NSAC long-range plan, spanning nuclear structure, nuclear astrophysics, and fundamental symmetries. Additionally, they contribute to addressing 10 out of the 17 benchmarks identified by the NRC RISAC. The development of a next-generation gas stopping device capable of delivering low-energy, rare-isotope beams at a rate of 10 8 particles per second, or more, with high purity holds the potential to unlock experiments that would otherwise be unfeasible. Furthermore, it is expected to reduce the time required for experiments at FRIB, thereby maximizing scientific output. The research and development activities performed as part of this project bolstered essential competencies at FRIB in beam physics and ion source technologies, provided valuable training opportunities for junior scientists.

43 PARTICLE ACCELERATORS↗

A Warm Jupiter Transiting an M Dwarf: A TESS Single-transit Event Confirmed with the Habitable-zone Planet Finder

We confirm the planetary nature of a warm Jupiter transiting the early M dwarf TOI-1899 using a combination of available TESS photometry; high-precision, near-infrared spectroscopy with the Habitable-zone Planet Finder; and speckle and adaptive optics imaging. The data reveal a transiting companion on an ∼29 day orbit with a mass and radius of 0.66±0.07 M{sub J} and 1.15{sub −0.05}{sup +0.04} R{sub J}, respectively. The star, TOI-1899, is the lowest-mass star known to host a transiting warm Jupiter, and we discuss the follow-up opportunities afforded by a warm (T{sub eq}∼362 K) gas giant orbiting an M0 star. Our observations reveal that TOI-1899.01 is a puffy warm Jupiter, and we suggest additional transit observations to both refine the orbit and constrain the true dilution observed in TESS.

79 ASTRONOMY AND ASTROPHYSICS↗

The NASA cosmic ray program for the 1990's and beyond

The interim report of the 1989 NASA Cosmic Ray Program Working Group is presented. The report summarizes the cosmic ray program for the 1990's, including the recently approved ACE, Astromag, HNC, POEMS, and SAMPEX missions, as well as other key elements of the program. New science themes and candidate missions are identified for the first part of the 21st century, including objectives that might be addressed as part of the Human Exploration Initiative. Among the suggested new thrusts for the 21st century are: an Interstellar Probe into the nearby interstellar medium; a Lunar-Based Calorimeter to measure the cosmic ray composition near 10 exp 16 eV; high-precision element and isotope spectroscopy of ultraheavy elements; and new, more sensitive studies of impulsive solar flare events.

Ahlen, S. P.↗

Searching for a Pulse

The Neutron star Interior Composition Explorer (NICER) is an International Space Station (ISS) mission of opportunity that was selected as part of NASA's Explorer Program. It is the first NASA mission dedicated to the study of neutron stars and has been in operation since its 13 June 2017 installation on the ISS (following a 3 June launch), nearly 50 years after the discovery of neutron stars. NICER studies the energetics, dynamics and structure of neutron stars through observations in the soft X-ray band, exploring rapid brightness and spectral fluctuations with high-precision time stamping and spectroscopy of individually detected X-ray photons. Compared with its predecessor X-ray timing astrophysics mission, the Rossi X-ray Timing Explorer(RXTE), which launched over two decades ago, NICER provides order-of-magnitude improvements in spectral resolution, absolute timing resolution and sensitivity.

Gendreau, Keith C.↗

Distributed Computing for the Project 8 Experiment

The Project 8 collaboration aims to measure the absolute neutrino mass or improve on the current limit by measuring the tritium beta decay electron spectrum. We present the current distributed computing model for the Project 8 experiment. Project 8 is in its second phase of data taking with a near continuous data rate of 1Gbps. The current computing model uses DIRAC (Distributed Infrastructure with Remote Agent Control) for its workflow and data management. A detailed meta-data assignment using the DIRAC File Catalog is used to automate raw data transfers and subsequent stages of data processing. The DIRAC system is deployed on containers managed using a Kubernetes cluster to provide a scalable infrastructure. A modified DIRAC Site Director provides the ability to submit jobs using Singularity on opportunistic High-Performance Computing (HPC) sites.

Distributed Computing, Kubernetes, DIRAC, Project ↗

Electronic states and transitions of PrO and PrO + probed by threshold ionization spectroscopy and spin–orbit multiconfiguration perturbation theory

The precise ionization energy of praseodymium oxide (PrO) seeded in supersonic molecular beams is measured with mass-analyzed threshold ionization (MATI) spectroscopy. Here, a total of 33 spin–orbit (SO) states of PrO and 23 SO states of PrO + are predicted by second-order multiconfigurational quasi-degenerate perturbation (MCQDPT2) theory. Electronic transitions from four low-energy SO levels of the neutral molecule to the ground state of the singly charged cation are identified by combining the MATI spectroscopic measurements with the MCQDPT2 calculations. The precise ionization energy is used to reassess the ionization energies and the reaction enthalpies of the Pr + O → PrO + + e – chemi-ionization reaction reported in the literature. An empirical formula that uses atomic electronic parameters is proposed to predict the ionization energies of lanthanide monoxides, and the empirical calculations match well with available precise experimental measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated frequency-modulated optical parametric oscillator

Optical frequency combs have revolutionized precision measurement, time-keeping, and molecular spectroscopy. A substantial effort has developed around "microcombs": integrating comb-generating technologies into compact, reliable photonic platforms. Current approaches for generating these microcombs involve either the electro-optic (EO) or Kerr mechanisms. Despite rapid progress, maintaining high efficiency and wide bandwidth remains challenging. Here, we introduce a new class of microcomb -- an integrated optical frequency comb generator that combines electro-optics and parametric amplification to yield a frequency-modulated optical parametric oscillator (FM-OPO). In stark contrast to EO and Kerr combs, the FM-OPO microcomb does not form pulses but maintains operational simplicity and highly efficient pump power utilization with an output resembling a frequency-modulated laser. We outline the working principles of FM-OPO and demonstrate them by fabricating the complete optical system in thin-film lithium niobate (LNOI). We measure pump to comb internal conversion efficiency exceeding 93% (34% out-coupled) over a nearly flat-top spectral distribution spanning approximately 1,000 modes (approximately 6 THz). Compared to an EO comb, the cavity dispersion rather than loss determines the FM-OPO bandwidth, enabling broadband combs with a smaller RF modulation power. The FM-OPO microcomb, with its robust operational dynamics, high efficiency, and large bandwidth, contributes a new approach to the field of microcombs and promises to herald an era of miniaturized precision measurement, and spectroscopy tools to accelerate advancements in metrology, spectroscopy, telecommunications, sensing, and computing.

42 ENGINEERING↗