Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Non-Intrusive Appliance Identification with Appliance-Specific Networks

The problem of noninstrusive load monitoring (NILM) is usually formulated as a single-channel blind source separation task, whose successful solution enable fast and convenient load identification and energy disaggregation. When applied at test time, NILM algorithms aim to identify the operating characteristics of individual appliances from an aggregate power measurement of the entire house. Recent advances in deep learning gave rise to many methods that mostly focus on learning a direct mapping from aggregate measurement to individual appliance power. However, these methods are not only computationally expensive, but they often suffer from overfitting and do not generalize very well. In this article, we propose a novel NILM method that leverages advances in statistical learning that have not been properly applied in this domain before. The proposed method consists of three stages: first, a Bayesian nonparametric learning-based approach for appliance state extraction; second, synthetic minority oversampling technique for data augmentation and mitigating the heavy imbalance in switching events; and third, appliance-specific lightweight long short-term memory networks for status classification for each appliance. Here, we adopt a “differential” input (the difference before and after the switching event) to reduce the complexity of network training and make the proposed method robust to multiappliance switching events. Experiments are conducted to demonstrate the effectiveness of the proposed method, achieving superior performance when compared to recent methods. An ablation study is conducted to demonstrate the effectiveness of each module of our method. Finally, we investigate the quality of generated synthetic samples.

42 ENGINEERING↗

Precise time and time interval applications to electric power systems

There are many applications of precise time and time interval (frequency) in operating modern electric power systems. Many generators and customer loads are operated in parallel. The reliable transfer of electrical power to the consumer partly depends on measuring power system frequency consistently in many locations. The internal oscillators in the widely dispersed frequency measuring units must be syntonized. Elaborate protection and control systems guard the high voltage equipment from short and open circuits. For the highest reliability of electric service, engineers need to study all control system operations. Precise timekeeping networks aid in the analysis of power system operations by synchronizing the clocks on recording instruments. Utility engineers want to reproduce events that caused loss of service to customers. Precise timekeeping networks can synchronize protective relay test-sets. For dependable electrical service, all generators and large motors must remain close to speed synchronism. The stable response of a power system to perturbations is critical to continuity of electrical service. Research shows that measurement of the power system state vector can aid in the monitoring and control of system stability. If power system operators know that a lightning storm is approaching a critical transmission line or transformer, they can modify operating strategies. Knowledge of the location of a short circuit fault can speed the re-energizing of a transmission line. One fault location technique requires clocks synchronized to one microsecond. Current research seeks to find out if one microsecond timekeeping can aid and improve power system control and operation.

Robert E. Wilson↗

A Constraint on Primordial B-modes from the First Flight of the Spider Balloon-borne Telescope

We present the first linear polarization measurements from the 2015 long-duration balloon flight of Spider, which is an experiment that is designed to map the polarization of the cosmic microwave background (CMB) on degree angular scales. The results from these measurements include maps and angular power spectra from observations of 4.8% of the sky at 95 and 150 GHz, along with the results of internal consistency tests on these data. While the polarized CMB anisotropy from primordial density perturbations is the dominant signal in this region of sky, Galactic dust emission is also detected with high significance. Galactic synchrotron emission is found to be negligible in the Spider bands. We employ two independent foreground-removal techniques to explore the sensitivity of the cosmological result to the assumptions made by each. The primary method uses a dust template derived from Planck data to subtract the Galactic dust signal. A second approach, which constitutes a joint analysis of Spider and Planck data in the harmonic domain, assumes a modified-blackbody model for the spectral energy distribution of the dust with no constraint on its spatial morphology. Using a likelihood that jointly samples the template amplitude and r parameter space, we derive 95% upper limits on the primordial tensor-to-scalar ratio from Feldman–Cousins and Bayesian constructions, finding r < 0.11 and r < 0.19, respectively. Roughly half the uncertainty in r derives from noise associated with the template subtraction. New data at 280 GHz from Spider's second flight will complement the Planck polarization maps, providing powerful measurements of the polarized Galactic dust emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Nonlinear interactions of electromagnetic waves with a thermally generated cesium plasma.

The interaction of a large‐amplitude disturbing wave with a thermally generated, highly ionized cesium plasma has been investigated using a small‐amplitude sensing wave as a probe. The subsequent interaction between the disturbing and sensing waves is related to the plasma electron temperature. The plasma was contained in a magnetic field of 500–1000 G and had an electron plasma frequency near 10 GHz and an electron gyromagnetic frequency around 2 GHz. The sensing wave was a 10 GHz plane wave of approximately 1.5 mW input power and the disturbing wave was 7.5 GHz plane wave of about 1.2 W peak power. Measurements of the sensing‐wave transmitted power were made using standard microwave techniques. A notch filter in the sensing‐wave receiving circuit reduced the scattered disturbing‐wave interference to an immeasurably low level. Langmuir probes were used to detect disturbing‐wave modulation and to measure plasma temperatures and densities. Measurements of the interaction were correlated with a solution of the Boltzmann transport equation for a perturbed Maxwellian distribution function with binary Coulomb collisions.

Jack G Hewitt, Jr↗

Statistical Behavior of Low-Amplitude Power System Point-on-Wave Measurements

The power grid is undergoing massive changes to ensure resiliency and reliability in a more decentralized world. Distributed energy resources are becoming a prominent source of generation, potentially leading to a lack of centralized generation sources. Due to these new behaviors and system topologies, it is important to install measurement devices that are 1) accurate and 2) self-aware of their measurement quality. In this paper, a residential-scale microgrid is used to generate voltage and current waveforms, captured by Verivolt and National Instruments measurement equipment. A least-squares approach is used to separate the “clean” signals from the noise. Finally, Gaussian mixture modeling is used to approximate noise distributions, and it is shown these higher-order distribution estimates are a better fit to voltage and current noise profiles than single-mode Gaussian estimates.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fish Friendly Water Rules' Impact On the Power Grid with High VRE Levels

Columbia River basin multipurpose reservoirs are operated for hydropower production and many other purposes considering the aquatic habitat of the river basin. Specifically, the river basin fish population is a vital element for the tribal community of the river basin. When conventional thermal power plants are retired, hydropower flexibility balances the wind and solar variability of the power grid and provides grid services to maximize the high renewable power absorption. On the other hand, over-reliance on hydropower could harm the river basin fish habitat. For example, water release pulses during peak electricity demand hours and shorter-term water release variation could harm the fish population. Power grid planners, environmentalists, Columbia Basin tribes, hydro regulators, and water resource planners work together to understand the impacts of Columbia River basin operation in a fish-friendly way in the current power grid and power grid with higher renewable power share. We examine different levels of renewable share in the Western Interconnection to understand the multiple weather years and future climate projection and operating scenario impact on the power grid and water system. We measure power grid impacts for various water resources planning scenarios in terms of total system operating cost, system reliability indicators, changes in wind and solar generation and curtailments, local marginal prices, and revenue for hydropower producers. The study results inform reservoir operating rules decisions from hydropower power producers, system operators, other water users, tribes, environmentalists, and other stakeholders.

environmental↗

Helioseismic Measurements of Convective Power in Solar Cycle 24

Constraining the parameters under which convection in the solar interior operates has important implications for describing how energy is transported by plasma motions, and various physical models have been employed to provide some theoretical estimates on the expected power spectrum. Past attempts to measure the convective power distributed among large spatial scales have, however, found differing and incompatible values. Here, we present measurements of the convective power spectrum in the upper convection zone for Carrington rotations in Solar Cycle 24 obtained from the helioseismic signal corresponding to East-West flows. We also perform calibration on synthetic data using the global acoustic GALE code to make assessments of the flow velocities at various length scales without the need for performing inversions. This allows us to derive the convective power spectrum from the flow maps and to compare with the results from the raw travel times. These results are compared against predictions of convective power in global models of convection produced by the EULAG code. Finally, we show how the steps in our analysis procedure (for example data segmentation, filtering, etc.) affect our estimates of the convective power by comparing with the synthetic data from the GALE code.

Heliophysics↗

Prevention of Dual-Mode Excitation in 9-Cell Cavities for LCLSII-HE

Dual-Mode Excitation, also referred to as mode-mixing, is a superposition of two fundamental pi modes in an SRF cavity. In 9-cell TESLA cavities used for the LCLSII-HE project, the two modes that are commonly excited are the pi mode (1300.2 MHz), and the 7/9 pi mode (1297.8 MHz). During vertical cavity qualification testing, only the pi mode is driven by the RF system. However, at high gradients, emitted power at the frequency of the 7/9 pi mode grows despite the RF system only powering the pi mode. When this happens, the RF power measurement system is unable to differentiate between the superimposed modes, and any data taken is invalid. The previous method of dealing with mode-mixing was to turn off power to the cavity, let both modes decay fully, then restore power. Because of the time-sensitive nature of this testing, this leads to underestimates of Q0 or any radiant field emission present in the cavity. The novel RF control solution prevents the 7/9 pi mode from being excited while not interfering with measurements of the fundamental pi mode. A second RF control system is connected to the cavity which drives the 7/9 pi mode. The loop phase for driving the 7/9 pi mode in self excited loop mode is determined then shifted by 180 degrees, thus providing a negative feedback to the undesired mode. Because this off-resonance power can be very small, on the order of milliwatts, it does not interfere with the high-power measurements of the fundamental pi mode. At Jefferson Lab, we are now able to test a cavity for the LCLSII-HE project with no problems from mode-mixing, which allows for CW processing of high-gradient multipacting and field emission.

Owen, Peter↗

Overcoming Communications Outages in Inverter Downtime Analysis

This paper presents two methods of detecting inverter downtime and estimating lost production from downtime events using timeseries system production measurements. The methods focus on distinguishing communications interruptions from true production outages and are successful in most cases. To enable fleet-scale analysis of inverter availability, the methods are designed to be semi-autonomous. The first method uses only inverter and system meter AC power measurements while the second uses cumulative production and expected energy data to classify outages and estimate lost production. The methods are demonstrated using real field data and the results are discussed.

41 EE - Solar Energy Technologies Office (EE-4S)↗