Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Mars Communication Protocols

Over the next decade, international plans and commitments are underway to develop an infrastructure at Mars to support future exploration of the red planet. The purpose of this infrastructure is to provide reliable global communication and navigation coverage for on-approach, landed, roving, and in-flight assets at Mars. The claim is that this infrastructure will: 1) eliminate the need of these assets to carry Direct to Earth (DTE) communications equipment, 2) significantly increase data return and connectivity, 3) enable small mission exploration of Mars without DTE equipment, 4) provide precision navigation i.e., 10 to 100m position resolution, 5) supply timing reference accurate to 10ms. This paper in particular focuses on two CCSDS recommendations for that infrastructure: CCSDS Proximity-1 Space Link Protocol and CCSDS File Delivery Protocol (CFDP). A key aspect of Mars exploration will be the ability of future missions to interoperate. These protocols establish a framework for interoperability by providing standard communication, navigation, and timing services. In addition, these services include strategies to recover gracefully from communication interruptions and interference while ensuring backward compatibility with previous missions from previous phases of exploration.

Kazz, G. J.↗

The Seyfert-Starburst Connection in X-rays: The Data - 1

We analyze X-ray spectra and images of a sample of Seyfert 2 galaxies that unambiguously contain starbursts, based on their optical and UV characteristics. Although all sample members contain active galactic nuclei (AGNs), supermassive black holes or other related processes at the galactic centers alone cannot account for the total X-ray emission in all instances. Eleven of the 12 observed galaxies are significantly resolved with the ROSAT High Resolution Imager, while six of the eight sources observed with the lower resolution Position Sensitive Proportional Counter also appear extended on larger scales. The X-ray emission is extended on physical scales of 10 kpc and greater, which we attribute to starburst-driven outflows and supernova heating of the interstellar medium. Spectrally, a physically motivated composite model of the X-ray emission that includes a heavily absorbed (N(sub H) greater than 10(exp 23)/sq cm) nuclear component (the AGN), power-law-like scattered AGN flux, and a thermal starburst describes this sample well. Half the sample exhibit iron K(alpha) lines, which are typical of AGNs.

Levenson, N. A.↗

A Concept for a High-Energy Gamma-ray Polarimeter

We present a concept for an imaging gamma-ray polarimeter operating from approx. 50 MeV to approx. 1 GeV. Such an instrument would be valuable for the study of high-energy pulsars, active galactic nuclei, supernova remnants, and gamma-ray bursts. The concept makes use of pixelized gas micro-well detectors, under development at Goddard Space Flight Center, to record the electron-positron tracks from pair-production events in a large gas volume. Pixelized micro-well detectors have the potential to form large-volume 3-D track imagers with approx. 100 micron (rms) position resolution at moderate cost. The combination of high spatial resolution and a continuous low-density gas medium permits many thousands of measurements per radiation length, allowing the particle tracks to be imaged accurately before multiple scattering masks their original directions. The polarization of the incoming radiation may then be determined from the azimuthal distribution of the electron-positron pairs. We have performed Geant4 simulations of these processes to estimate the polarization sensitivity as a function of instrument parameters and event selection criteria.

Bloser, P. F.↗

Piezoelectric Rotary Tube Motor

A custom rotary SQUIGGLE(Registered TradeMark) motor has been developed that sets new benchmarks for small motor size, high position resolution, and high torque without gear reduction. Its capabilities cannot be achieved with conventional electromagnetic motors. It consists of piezoelectric plates mounted on a square flexible tube. The plates are actuated via voltage waveforms 90 out of phase at the resonant frequency of the device to create rotary motion. The motors were incorporated into a two-axis postioner that was designed for fiber-fed spectroscopy for ground-based and space-based projects. The positioner enables large-scale celestial object surveys to take place in a practical amount of time.

Fisher, Charles D.↗

ISS-Lobster: A Proposed Wide-Field X-Ray Telescope on the International Space Station

The Lobster wide-field imaging telescope combines simultaneous high FOV, high sensitivity and good position resolution. These characteristics can open the field of X-Ray time domain astronomy, which will study many interesting transient sources, including tidal disruptions of stars, supernova shock breakouts, and high redshift gamma-ray bursts. Also important will be its use for the X-ray follow-up of gravitational wave detections. I will describe our present effort to propose the Lobster concept for deployment on the International Space Station through a NASA Mission of Opportunity this fall.

Camp, Jordan↗

Repurposing the James Webb Space Telescope’s center of curvature optical bench hexapod for future mirror calibration testing at NASA Marshall’s x-ray & cryogenic facility

The James Webb Space Telescope’s (JWST) center of curvature optical bench (CoCOB) hexapod was repurposed to enhance NASA Marshall Space Flight Center’s X-Ray & Cryogenic Facility (XRCF) optical metrology capabilities. This upgrade unlocked higher test article load capacity and extended the allowable ranges of motion of the CoCOB hexapod. The hexapod was also coupled to a new long-stroke, linear motion axis to form a 7 degrees of freedom system and allow for high precision testing of larger diameter test articles. A 9 degrees of freedom motion system, consisting of a three-axis linear mount in an X-Y-Z configuration and a commercially available hexapod, was also designed to allow high resolution positioning of the focal plane instrumentation over a large range of motion. A modern control architecture and graphical user interface was developed for the CoCOB hexapod and additional motion stages to permit streamlined commanding and operation. This paper discusses the justification for re-using the CoCOB hexapod by highlighting its unique precision motion control capabilities in a high vacuum and optically clean environment. The design, key component selection, and environmental compatibility for each of the additional motion stages is presented along with testing results for achieved range, repeatability, and minimum step size performance for all motion axes. Finally, a summary of the motion control system architecture and its flexibility to address tomorrow’s optical metrology needs are presented.

hexapod↗

Neutral Pion Electroproduction and development of a Neutral Particle Spectrometer

Protons and neutrons, i.e. nucleons, are the basic building blocks of the matter in the visible universe. The strong force binds the nucleons to form nuclei. The electromagnetic force forms the atoms by binding the electrons with the nuclei. The electromagnetic interaction is well understood by Quantum Electrodynamics (QED), which shows the most precise predictability amongst all the theories in physics. In QED, charges interact with each other by exchanging photons. The Quantum Chromodynamics (QCD) describes the strong interaction. Its degrees of freedom are quarks and gluons, the fundamental constituents of the nucleons. The quarks interact with each other by exchanging gluons. However, unlike QED, the gluons interact amongst themselves. This feature of self bindings of the gluons confines the quarks and gluons in the nucleons/hadrons, never to be seen as free. In order to study some of the features of QCD, such as confinement or the structure of the nucleon, one usually needs to rely on experiments. Electromagnetic probes, governed by the well-understood QED, are excellent tools to probe the nucleon. In general, different scales, e.g. electron beam energies, probe different regions of the nucleon. At low energy, of the order of a few GeV, the electron probes the nucleon in the valence quark region. As its energy increases, the electron probes the sea quark and gluon regions. The study of the nucleon structure in all these regions is needed to fully understand QCD. Form factors and parton distribution functions measured from elastic scattering and deep inelastic scattering of leptons off nucleons have provided a partial view of the internal structure of the nucleon. In the mid-1990s, Generalized Parton Distributions (GPDs) were developed. These new objects are a generalization of the form factors and parton distribution functions, but contain richer information on the nucleon internal structure. GPDs are accessible experimentally by deep exclusive reactions. Deeply virtual Compton scattering (DVCS) and deeply virtual meson production (DVMP) are some examples. The first dedicated DVCS/DVMP experiment took place in 2004 in Hall A at The Thomas Jefferson National Accelerator Facility, i.e. Jefferson Lab, in Virginia, U.S.A. A new DVCS/DVMP experiment, after the beam energy upgrade of Jefferson Lab, was carried out in Hall A in a wider kinematic range. Its data were taken from 2014 to 2016. In Hall C at Jefferson Lab, the next DVCS/DVMP experiment will take place. The Hall C experiment will further exploit the kinematic range with higher precision. A Neutral Particle Spectrometer (NPS) is in development to measure DVCS/DVMP events under high background conditions. Jefferson Lab will provide the highest precision data in the valence quark region for various exclusive reactions. The Electron-Ion Collider (EIC) is a future experimental facility currently planned to start operations around 2030 in the U.S.A. Its high energy and high luminosity will probe the sea quark and gluon regions providing answers to the outstanding questions of QCD, in particular in the region where matter is dominated by gluons. First of all, this document describes the data analysis and results of the Hall A neutral pion electroproduction off the proton, from the data taken in 2014-2016. Later, some of the developments towards the construction of the electromagnetic calorimeter of the NPS for the upcoming DVCS/DVMP experiment in Hall C are presented. Finally, one of the candidate materials for the EIC calorimeter, a glass scintillator, will be briefly introduced. I have participated to all these projects, in collaboration with many colleagues. I present in this thesis my contributions to each of these projects. My contributions to the neutral pion data analysis were focused on background subtractions on the calorimeter, acceptance calculations, and the estimation of the systematic uncertainty associated to the event selection cuts. Some necessary information on calibrations of the detectors and data analysis methods are also described. In the NPS project, I performed background dose calculations and energy and position resolution studies of the calorimeter, all using Monte Carlo simulations, with realistic geometries of the experimental apparatus. Characterization of the crystals of the calorimeter was also done. Additionally, I measured the radiation hardness of some glass scintillator in its early stage of development. In order to have a future reference when the glass calorimeter prototype will be tested, I simulated the energy resolution of the prototype.

Ko, Ho-San↗

Performance Before and After Irradiation of Pixelated 3D Silicon Sensors for the HL-LHC CMS Tracker

The Large Hadron Collider (LHC) particle accelerator at European Center for Nuclear Research (CERN) will be shut down starting in 2026 to achieve the High Luminosity Large Hadron Collider (HL-LHC) upgrade. The upgrade will allow for higher fluences, in order to increase the probability of detecting increasingly rare particles, and to obtain higher precision measurements of known particles. To accommodate the new accelerator conditions, many aspects of the Compact Muon Solenoid (CMS) detector will be upgraded; of particular interest for this thesis are the silicon pixel detectors located in the inner tracker. These will be replaced and upgraded to accommodate the higher fluences of the HL-LHC upgrade, as well as to replace existing sensors which have sustained radiation damage. In order for the new sensors to operate under high luminosity conditions, they must be increasingly radiation hard, and in order to detect rare particles, they must be increasingly more precise. The performance of one Centro Nacional de Microelectronica (CNM) 3D silicon sensor before and after undergoing irradiation at fluences similar to those which will be observed at the HL-LHC was investigated to determine radiation hardness and precision. Data was collected at Fermi National Laboratory (Fermilab), in the Fermi National Laboratory Test Beam Facility (FTBF) silicon tracker telescope, which can be used to determine the number of particles, and tracks made by high energy protons passing through. The sensor was also irradiated at Fermilab in the Irradiation Test Area (ITA). Prior to data collection a tuning procedure is carried out to determine ideal bias voltage operating conditions, mask noisy and dead pixels, adjust to the ideal threshold, and map sensor gain. Data is then collected at the FTBF, where the sensor is installed in the center of the FTBF silicon telescope. Variables, including angle and bias voltage, are varied throughout data collection. Data is then processed using an alignment software to determine the exact telescope geometry, along with the tracks which were observed passing through the sensor and telescope. Sensor performance was found to be comparable before and after irradiation, with irradiated results showing slightly lower efficiencies and cluster sizes. Position resolution is comparable both before and after irradiation, and similar distributions of cluster shape are observed. After irradiation, the sensor shows increasing collected charge with bias, an indication of increased width of the depletion region. Peak charge pre-irradiation is higher than post-irradiation peak charge, indicating the irradiated results are not taken under fully-depleted conditions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Neutron Electromagnetic Form Factor Ratio at High Momentum Transfer

The inner structure of the nucleon (proton and neutron) remains a topic of great interest in nuclear and particle physics, after many decades of study. For example, understanding the quark-gluon dynamics inside the nucleon would shed light on how 99% of the nucleon mass is created. The neutron electromagnetic form factors, Gn E and Gn M , give important insights into the neutron structure. The Super BigBite Spectrometer (SBS) program at Jefferson Lab (JLab) seeks to extend the form factor measurements for both the proton and the neutron. The neutron electric form actor, Gn E , has been historically difficult to measure due to the short lifetime of the free neutron and the small value of Gn E . The GEn-II experiment is part of the SBS program and seeks to measure Gn E , significantly increasing the high momentum transfer coverage. A newly designed polarized 3He target increased the figure of merit by three times compared to previous measurements. The analysis of this data is especially challenging due to the unprecedented high-rate environment caused by the open nature of the spectrometer with a direct line of sight to the target. This required developing new Gas Electron Multiplier (GEM) particle trackers which can cover large areas demanded by this setup and handle particle rates up to 500 kHz/cm2. Rates this high over a large area is unprecedented in particle tracking systems and came with a number of challenges. Data taken in the SBS program was critical to understanding hardware and software solutions that improved the track reconstruction efficiency to be >97% with a position resolution of 70 ?m. In previous experiments the proton electromagnetic form factors, Gp E and Gp M were measured up to Q2 = 8.5 GeV2 and Q2 = 30 GeV2, respectively, while Gn E has only been measured up to Q2 = 3.4 GeV2. The GEn-II experiment has measured the neutron form factor ratio, Gn E/Gn M, at Q2 values of 2.90, 6.50, and 9.47 GeV2 by scattering a polarized electron beam with a polarized 3He target, used here as an effective polarized neutron target, and measuring the double spin asymmetry of the cross section. Previous Gn E measurements do not extend above Q2 = 3.4 GeV2, and therefore this analysis has extended the world data by almost three times. The background correction is especially difficult at the higher Q2 settings leading to large systematic errors. As very exploratory results from this early analysis of the data, we find for Q2 = 2.90 GeV2, Gn E = 0.0157 ±stat 0.0016 ±sys 0.0011, for Q2 = 6.50 GeV2, Gn E = 0.0067 ±stat 0.0019 ±sys 0.0005, and for Q2 = 9.46 GeV2, Gn E = 0.0046 ±stat 0.0023 ±sys 0.0005. These results are compared to predictions from the Dyson-Schwinger Equations (DSE) model and a Relativistic Constituent Quark Model (RCQM).

Jeffas, Sean↗

Measurement of the Neutron Magnetic Form Factor at Large Momentum Transfer Using the Super-Bigbite Apparatus in Jefferson Lab Hall-A

The nucleon elastic electromagnetic form factors help us study the electromagnetic structure of the nucleon, benchmark theoretical models, and improve our understanding of non-perturbative quantum chromodynamics and confinement. The Nobel Prize-winning electron-nucleon scattering experiments by Robert Hofstadter and collaborators in the 1950s at Stanford High Energy Physics Lab were the first nucleon form factor measurements performed using leptonic probes. The Super Bigbite Spectrometer (SBS) program at Hall-A of Jefferson Lab represents the latest efforts to measure nucleon form factors. This ambitious program aims to significantly extend the current data set in terms of square momentum transfer (Q2) with high precision. The advent of novel detector technologies, like Gas Electron Multipliers (GEM), which provide excellent position resolution (< 100 ?m) while withstanding high background particle rates (several hundred MHz/cm2) over a large active area, has paved the way for open-geometry, moderate solid angle spectrometers, which are central to all form factor experiments in the SBS program. The first experimental run group in SBS ran successfully between September 2021 and February 2022, collecting data for the measurement of the magnetic form factor of the neutron Gn M at five squared momentum-transfer values: 3.0, 4.5, 7.5, 9.8, and 13.5 (GeV /c)2. This extends the existing high-precision data for Gn M by about a factor of four. The ratio technique was used, which involved the simultaneous measurement of exclusive quasielastic scattering of D(e,e?n)p and D(e,e?p)n from a deuterium target. Pre-preliminary results for D(e,e?n)p and D(e,e?p)n quasi-elastic ratio, and the neutron magnetic form factor Gn M , for Q2 points 3.0, 9.8, and 13.5 (GeV /c)2 are presented.

Mudiyanselage, Anuruddha Rathnayake↗

Measurement of the Neutron Elastic Electromagnetic Form Factor Ratio at Large Momentum Transfer

Exploring nucleon structure is vital both for understanding its origin and existence as well as for the advancement of the sciences. It helps us answer key questions such as how quark and gluon dynamics create 99% of the nucleon mass. Electron- nucleon scattering has been widely used for precision studies of the nucleon and nuclear structure since the Nobel Prize winning investigations by Robert Hofstadter and collaborators in the 1950s. These studies provide information about the spatial charge and current densities of the nucleon in terms of the electromagnetic form factors. The form factors are functions of four momentum transfer squared (Q2). Extending the electromagnetic form factor measurements to higher Q2 plays a critical role in furthering the understanding of nucleon structure. This motivated the Super BigBite Spectrometer (SBS) program at Jefferson Lab. The open nature of the spectrometers and the direct line of sight from the target to the tracking detector locations in experimental setups such as SBS creates high levels of background at the detectors. This necessitates the use of tracking detectors with high rate capability and good position resolution. Gas Electron Multiplier (GEM) detectors are an excellent choice for tracking detectors in such experiments. Understanding the performance of the GEM detectors is important not just for SBS experiments but also for future high-luminosity experiments. This thesis reports the exploratory results from the measurement of the neutron elastic electromagnetic form factor ratio (Gn E/Gn M) at high momentum transfer. A longitudinally polarized electron beam was scattered off a polarized 3He target, used as an effective polarized neutron target. In this experiment, the polarized 3He target achieved a world record polarization weighted luminosity at a beam current of 45 µA. Double spin asymmetry of the scattered neutron events is used to extract the neutron form factor ratio. Measurements were taken at Q2 = 3.0, 6.8, 9.8 (GeV/c)2. The lowest Q2 measurement is in good agreement with the existing world data, and the higher-Q2 measurements extend the Q2 reach well beyond the existing world data and are expected to remain unmatched for a long time.

Gamage, Vimukthi Haththotuwa [Univ. of Virginia, C↗

A high resolution study in time, position, intensity, and frequency of a radio event on 14 January 1971

High resolution position and spectrum measurements were made of a complex solar radio activity on January 14, 1971, from 1120 to 1130 UT. Positions were measured with 169 MHz Nancay E-W Radioheliograph, while dynamic spectra and polarization were observed with the 60-channel radiospectrograph of Nera. The radio event consisted of two closely similar groups of type 3 bursts and type 2-like details, and a stationary type 4 continuum, including some very clear pulsating structures. The general aspect of this activity is presented.

Caroubalos, C.↗

On the accuracy of CO line positions for high resolution IR stellar spectroscopy

The paper demonstrates the high accuracy of line positions derived from improved sets of Dunham coefficients for the four more abundant isotopic species of carbon monoxide - (C-12)(O-16), (C-13)(O-16), (C-12)(O-18), and (C-12)(O-17) - which are present in the sun and in cool stellar atmospheres. These new spectroscopic constants make it possible to predict very accurate positions of CO lines at any J-values, especially at very high rotational excitation (up to J around 135). Earlier proposed identifications of CO lines at large J-values are checked, and some incorrect identifications in sunspot spectra are found. The present accurate line positions are also compared with predictions from other available sets of molecular constants. It is concluded that the present improved sets of molecular constants are the most appropriate to all problems of high-resolution stellar and solar spectroscopy at any J- and v-values, particularly for synthetic spectra of cool stars.

Sauval, A. J.↗

Improving Chirped Fiber Bragg Grating Resolution for Position-Sensitive Sensors in Shock- and Detonation-Driven Experiments

Chirped fiber Bragg gratings (CFBGs) are robust diagnostic sensors that are widely used to track detonation-driven and shock wave propagation. CFBGs are inscribed with a linearly chirped periodic index of refraction changes that alter the Bragg wavelength along the length of the probe. The light return of each individual Bragg element is captured by a detector at a unique time to map the full reflected spectrum. The CFBG spectrum is measured with a dispersive Fourier transform of the reflected light that temporally stretches the spectrum to increase spatial resolution and make a one-to-one map of the wavelength on a time axis. Here, we propose an improvement of CFBG temporal resolution by incorporating two co-linear laser pulses with orthogonal polarization states and a 5 ns time offset. The two separate signals were split and tracked by two separate detectors. An oscilloscope captured good separation in the signals, and two separate spectrograms were generated and interleaved in the post-processing of the data. This novel technique doubled the CFBG temporal resolution and led to a doubled location resolution. As a proof-of-concept of this technique, the resolution improvement was compared between standard CFBG measurements and the two polarization states method on a position-sensitive CFBG sensor. CFBG resolution doubling will advance sensor capabilities and will have a direct impact on improving capture and analysis in dynamic, high-explosive experiments.

42 ENGINEERING↗

Ambiguity resolution for satellite Doppler positioning systems

A test for ambiguity resolution was derived which was the most powerful in the sense that it maximized the probability of a correct decision. When systematic error sources were properly included in the least squares reduction process to yield an optimal solution, the test reduced to choosing the solution which provided the smaller valuation of the least squares loss function. When systematic error sources were ignored in the least squares reduction, the most powerful test was a quadratic form comparison with the weighting matrix of the quadratic form obtained by computing the pseudo-inverse of a reduced rank square matrix. A formula is presented for computing the power of the most powerful test. A numerical example is included in which the power of the test is computed for a situation which may occur during an actual satellite aided search and rescue mission.

Argentiero, P. D.↗

The fundamental bands of HCl-35 and HCl-37 - Line positions from high-resolution laboratory data

Accurate measurements of the positions of lines of the (1-0) vibration-rotation bands of HCl-35 and HCl-37 are reported. The new measurements have been derived from a laboratory spectrum recorded with a Fourier transform spectrometer operated at an unapodized spectral resolution of 0.0060/cm. Molecular constants are reported from a simultaneous least-squares analysis of these measurements and selected infrared and far-infrared data taken from the literature. The motivation for the present investigation is the need for improved HCl line positions for use in IR atmospheric remote sensing investigations.

Rinslad, Curtis P.↗