Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plastic scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Streaming readout for next generation electron scattering experiments

Current and future experiments at the high-intensity frontier are expected to produce an enormous amount of data that needs to be collected and stored for offline analysis. Thanks to the continuous progress in computing and networking technology, it is now possible to replace the standard ‘triggered’ data acquisition systems with a new, simplified and outperforming scheme. ‘Streaming readout’ (SRO) DAQ aims to replace the hardware-based trigger with a much more powerful and flexible software-based one, that considers the whole detector information for efficient real-time data tagging and selection. Considering the crucial role of DAQ in an experiment, validation with on-field tests is required to demonstrate SRO performance. In this paper, we report results of the on-beam validation of the Jefferson Lab SRO framework. In this work, we exposed different detectors (PbWO-based electromagnetic calorimeters and a plastic scintillator hodoscope) to the Hall-D electron-positron secondary beam and to the Hall-B production electron beam, with increasingly complex experimental conditions. By comparing the data collected with the SRO system against the traditional DAQ, we demonstrate that the SRO performs as expected. Furthermore, we provide evidence of its superiority in implementing sophisticated AI-supported algorithms for real-time data analysis and reconstruction.

47 OTHER INSTRUMENTATION↗

Instrumentation and Techniques in High Energy Physics

This book provides an introduction of some of the technology and techniques of modern particle physics. Each chapter is a deep dive into the relevant subject, which includes silicon pixel detectors, plastic scintillator in a high radiation environment, Cerenkov detectors, particle jet identification, noble gas neutrino detectors, and machine learning. The target audience is graduate students and more senior researchers who wish to learn a new technology or technique. The text pedagogical in nature and each chapter is a standalone treatment of a specific topic. The coverage focuses on state-of-the-art techniques, rather than describing the technology's history. Written by acknowledged experts in the subject matter, Instrumentation and Techniques in High Energy Physics, is an important addition to the library of any particle physicist.

Lincoln, Don↗

Mulan: a part-per-million measurement of the muon lifetime and determination of the Fermi constant

The part-per-million measurement of the positive muon lifetime and determination of the Fermi constant by the MuLan experiment at the Paul Scherrer Institute is reviewed. The experiment used an innovative, time-structured, surface muon beam and a near-4 \pi π , finely-segmented, plastic scintillator positron detector. Two in-vacuum muon stopping targets were used: a ferromagnetic foil with a large internal magnetic field, and a quartz crystal in a moderate external magnetic field. The experiment acquired a dataset of 1.6 \times 10^{12} 1.6 × 10 12 positive muon decays and obtained a muon lifetime \tau_{\mu} = 2\, 196\, 980.3(2.2) τ μ = 2 196 980.3 ( 2.2 ) ~ps (1.0~ppm) and Fermi constant G _F = 1.166\, 378\, 7(6) \times 10^{-5} F = 1.166 378 7 ( 6 ) × 10 − 5 GeV ^{-2} − 2 (0.5~ppm). The thirty-fold improvement in \tau_{\mu} τ μ has proven valuable for precision measurements in nuclear muon capture and the commensurate improvement in G _F F has proven valuable for precision tests of the standard model.

Carey, Rebecca↗

Cosmic Background Rejection of the ICARUS experiment at Fermilab

The Short Baseline Neutrino program at Fermilab aims to explore significant regions of parameter space, applicable to sterile neutrinos at the eV mass scale, as suggested by existing experimental anomalies. To this purpose it exploits Liquid Argon Time Projection Chamber detectors located along the Booster Neutrino Beamline to measure both νe appearance and νµ disappearance: the Short Baseline Neutrino Detector and the ICARUS-T600 detector at 110 and 600 m from the neutrino source, respectively. The ICARUS T-600 Far Detector, located at shallow depth, is surrounded by a Cosmic Ray Tagger system to mitigate the cosmic ray background. On average ~ 11 muon tracks are expected to cross the detector during the ~ 1 ms drift time. The cosmic ray tagger is composed of plastic scintillator bars, ensuring near 4π coverage of the detector aiming at tagging cosmic muons and thus reject 𝛾s produced by muon interactions in the surrounding materials that can generate an electromagnetic showers mimicking a νe signal. The system allows one to disentangle cosmic rays from particles originated in a neutrino interaction inside the detector by measuring their position and crossing time. A synchronization of the cosmic ray tagger with the ICARUS photon detection system with a nanosecond accuracy allows one to reject cosmic particles recorded during the beam spill and thus select an enriched sample of neutrino triggered events ahead of the event reconstruction. An overview of the cosmic ray tagger system as well as its role in the neutrino events identification and cosmic background rejection will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-Volume Scatter Camera (Final Report)

This document serves as a comprehensive final report for the Single-Volume Scatter Camera (SVSC) project. Most of the work over the course of this project has been documented in journal articles, conference papers, and other reports. We therefore reference those materials for detailed presentation of our technical results. The most recent efforts on the project have not been published and are presented in detail here. We present characterizations of two neutron scatter camera prototypes; one using a monolithic geometry, and one using an optically segmented geometry. Both detectors employ plastic scintillator with SiPM-based readout. For the monolithic prototype, we present calibrations of several detector parameters made using a set of dark counts. In particular, we employ a coincidence analysis to characterize the distribution external optical crosstalk, along with the relative timing of the different SiPMs. For the optically segmented prototype we present the results of calibrations made using a tagged 22 Na source, as well as the results of an imaging measurement made using a tagged AmBe source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developments to the Distributed Holdup Monitoring System in Fiscal Year 2025

Permanently installed holdup monitoring would provide a myriad of benefits to nuclear facilities, ranging among decreased facility burden, increased safety bases, and increased accuracy of relevant material controls and accountancy metrics. However, the cost per detection system must be affordable to provide reliable coverage. For this project, the target unit price per system has been $\$$1,000. Recent work has focused on pushing costs lower through developing a plastic scintillator and silicon photomultiplier (SiPM)–based front end, which are components that are not commercially available in conjunction with each other. Other work has included further system development and use of a low-cost SiPM. Finally, a limited deployment at a processing facility was achieved. Results from this deployment and the development process are discussed in detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FNCL Enhancements Implementation (FY25 Annual Report)

The FNCL investigations team at Lawrence Livermore National Laboratory (LLNL) has completed research and development of hardware, signal processing, and analysis tools to enhance the measurement capabilities of both the current CAEN SyS VeryFuel Fast Neutron Collar (FNCL) instrument and a next-generation FNCL prototype. The team successfully built and commissioned the LLNL Demonstrator System: a fully integrated, three-panel detector system featuring higher segmentation, plastic scintillators (EJ-276D), Silicon Photomultipliers (SiPMs), no high-voltage requirement, a reduced electronic footprint, and the LLNL-developed Gaussian Mixture Model Pulse Shape Discrimination (GMM-PSD) signal processing. An extensive experimental campaign was conducted at LLNL’s Inherently Safe Subcritical Assembly (ISSA) facility using both the baseline FNCL and the LLNL Demonstrator. The campaign results validated system performance, calibration stability, and the effectiveness of advanced signal processing and analysis algorithms in a relevant environment.

and physical protection↗

TRIPWIRE – Deployment and Field-Testing Report

TRIPWIRE is a multi-modal system for containment verification in inaccessible radiological and nuclear waste repositories. The sensing modes are focused on radiation, electromagnetic and vibration. The radiation detection component has been developed over the last three years at Idaho National Laboratory (INL). This development has focused on the fabrication, characterization, and testing of long-length (greater than 10-m) plastic scintillating fibers. This fiscal year, the focus of TRIPWIRE has been on field testing and demonstration of the radiation sensing component in a relevant environment. After reviewing the static storage facilities at INL, the Radioactive Scrap Waste Facility (RSWF) south storage area outside the Materials and Fuels Complex (MFC) was selected due to its periodic changes in configuration and inventory. This report summarizes the research outcomes for the work performed in fiscal year (FY) 2023.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

MC-Lite: Development of a new lightweight multiplicity counter

This report details the development of a neutron multiplicity counter based on lithium doped plastic scintillators. This system has the capability to measure and discriminate fast neutrons, thermal neutrons, and gamma-rays allowing for multi-particle correlations in one device. The system was built and tested at Lawrence Livermore National Laboratory with Cf-252 in both bare configurations and surrounded by polyethylene and compared against the MC-15 multiplicity counter. Additionally, the detector was also placed outside of a subcritical assembly and demonstrated the ability to use correlated gamma-rays as a probe on the multiplication of the item.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring Neutron Polarisation in Deuteron Photo-disintegration with the CLAS Start Counter [Thesis]

Deuteron photo-disintegration (γd → γp) is a reaction that represents the simplest case in which nuclear and hadron physics models can be tested. Despite this, associated polarization analyses are limited in terms of angular coverage and energy ranges, especially in observables related to the recoil neutron. This is largely due to a lack in dedicated polarimetry equipment, and represents a roadblock in global progress to understand high-energy phenomena such as hexaquarks, and quark-gluon degrees of freedom. To address this problem, this PhD thesis pioneers a new methodology for the parasitic measurement of nucleon polarization using kinematic reconstruction of (spin-dependent) nucleon-nucleus scattering of reaction products, prior to their detection in large acceptance particle detector apparatus. Following this novel approach, which requires no dedicated polarimeter, a determination of the double polarization observable, $C^n_{x'}$, from deuteron photo-disintegration is presented, using Jefferson Lab’s CLAS detector. The analysis utilizes the (n,p) charge exchange reaction in CLAS’s "start counter" (plastic scintillator) to determine the final state neutron polarizations. The results present the first ever data for this observable above 0.7 GeV (photon beam energy) and significantly extend the angular range of the world data set. This new data is largely statistically consistent with the previous measurement of $C^n_{x'}$ by Bashkanov et al . in the overlapping energy range of 0.4-0.7 GeV. It is planned for the statistical accuracy of the presented result to be increased by the inclusion of additional data. The analysis herein serves as a key proof of concept for future applications, including a recommended similar analysis to be implemented with data from the more modern CLAS12 detector. This paves the way for a plethora of additional analyses using existing data sets that would provide crucial new constraints for hadron and nuclear physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Understanding the temperature and humidity dependence of the SiPM characteristics

A miniature version of the ICAL experiment at the India-based Neutrino Observatory, the mini-ICALis in operation at the IICHEP, Madurai. The commissioning work of a Cosmic Muon Veto detector (CMVD)on top of the mini-ICAL is continued using extruded plastic scintillators with embeddedWLS fibers and the SiPM as a photo-transducer. The CMVD is being built to study thefeasibility of a cosmic muon veto for a shallow-depth neutrino experiment. The SiPM is calibratedusing an ultrafast LED driver andthe same calibration techniques will be used during the data taking period with a simplified LED in thesame readout PCB. An experimental setup wasdesigned to characterise the SiPMs in a temperature controlled environment. The readout electronicsinvolves trans-impedance amplifiers and a voltage followers of combined gain 1.24 mV/$\mu$A and adigital storage oscilloscope for the data collection with a minimal distortion of SiPM signal.Various characteristics of the Hamamatsu SiPM (S13360-2050VE), e.g. signal shape, optically correlatedand uncorrelated noise, recovery time etc were studied as a function of $V_{ov}$, number of photoelectrons,the ambient temperature and the humidity. This paper will cover the details of those results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MURAVES Experiment: A Study of the Vesuvius Great Cone with Muon Radiography

The MURAVES experiment aims at the muographic imaging of the internal structure of the summit of Mt. Vesuvius, exploiting muons produced by cosmic rays. Though presently quiescent, the volcano carries a dramatic hazard in its highly populated surroundings. The challenging measurement of the rock density distribution in its summit by muography, in conjunction with data from other geophysical techniques, can help the modeling of possible eruptive dynamics. The MURAVES apparatus consists of an array of three independent and identical muon trackers, with a total sensitive area of 3 square meters. In each tracker, a sequence of 4 XY tracking planes made of plastic scintillators is complemented by a 60 cm thick lead wall inserted between the two downstream planes to improve rejection of background from low-energy muons. The apparatus is currently acquiring data. Preliminary results from the analysis of the first data sample are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass testing of SiPMs for the CMVD at IICHEP

A Cosmic Muon Veto Detector (CMVD) is being built around the mini-Iron Calorimeter (mini-ICAL) detector at the transit campus of the India based Neutrino Observatory, Madurai. The CMV detector will be made using extruded plastic scintillators with embedded wavelength shifting (WLS) fibres which propagate re-emitted photons of longer wavelengths to silicon photo-multipliers (SiPMs). The SiPMs detect these scintillation photons, producing electronic signals. The design goal for the cosmic muon veto efficiency of the CMV is $>$99.99% and fake veto rate less than 10$^{-5}$. A testing system was developed, using an LED driver, to measure the noise rate and gain of each SiPM, and thus determine its overvoltage ($V_{ov}$). This paper describes the test results and the analysed characteristics of about 3.5k SiPMs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Calibration Studies for the SuperCDMS SNOLAB Experiment

My time at Fermilab has been dedicated to advancing the field of dark matter detection through my contributions to the SuperCDMS collaboration. The first project involved the development and testing of a delivery system for a Cf-252 neutron source to calibrate the SuperCDMS silicon and germanium detectors. Subsequently, I focused on parametrizing the detectors' instrumental response by optimizing a plastic scintillator backing array to measure the scattering angle of a collimated neutron beam. The Monte Carlo simulation I designed provided insights into the detection efficiency of the array, and the best-fit design I arrived at for the scattering counters will be implemented into the final array. Additionally, I assembled a muon detector with legacy hardware to enhance the ability of the calibration experiment to reduce dark current and false signals. As my work nears completion, I am confident that these contributions will significantly enhance the precision and reliability of the SuperCDMS experiment, pushing the boundaries of our understanding of dark matter and contributing to the broader scientific community's quest to unravel the mysteries of the universe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation tools, first results and experimental status of the MURAVES experiment

The MUon RAdiography of VESuvius (MURAVES) project aims at the study of Mt. Vesuvius, an active and hazardous volcano near Naples, Italy, with the use of muons freely and abundantly produced by cosmic rays. In particular, the MURAVES experiment intends to perform muographic imaging of the internal structure of the summit of Mt. Vesuvius. The challenging measurement of the rock density distribution in its summit by muography, in conjunction with data from other geophysical techniques, can help model possible eruption dynamics. The MURAVES apparatus consists of an array of three independent and identical muon trackers, with a total sensitive area of 3 square meters. In each tracker, a sequence of 4 XY tracking planes made of plastic scintillators is complemented by a 60 cm thick lead wall inserted between the two downstream planes to improve rejection of background from low energy muons. The apparatus is currently acquiring data. This paper presents preliminary results from the analysis of the first data samples acquired with trackers pointing towards Mt. Vesuvius, including the first relative measurement of the density projection of two flanks of the volcano at three different altitudes; we also present the workflow of the simulation chain of the MURAVES experiment and its ongoing developments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A High-Precision, Fast, Robust, and Cost-Effective Muon Detector Concept for the FCC-ee

We propose a high-precision, fast, robust and cost-effective muon detector concept for an FCC-ee experiment. This design combines precision drift tubes with fast plastic scintillator strips to enable both spatial and timing measurements. The drift tubes deliver two-dimensional position measurements perpendicular to the tubes with a resolution around 100~$\mu$m. Meanwhile, the scintillator strips, read out with the wavelength-shifting fibers and silicon photomultipliers, provide fast timing information with a precision of 200~ps or better and measure the third coordinate along the tubes with a resolution of about 1~mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The General Antiparticle Spectrometer (GAPS) Antarctic Balloon Payload

The General Antiparticle Spectrometer (GAPS) is an Antarctic stratospheric balloon mission designed to provide unmatched sensitivity to low-energy (<0.25 GeV/n) cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter. The distinctive GAPS particle identification technique relies on measuring the energy loss along the track of an incoming antinucleus as it slows down and is captured into an exotic atom, and then detecting the de-excitation X-rays and the nuclear annihilation products. This measurement is realized using a Tracker composed of more than 1000 custom silicon strip detectors and a plastic scintillator time-of-flight (TOF) system instrumenting more than 40m$^2$. Together, these subsystems provide the velocity and energy resolution, stopping power, particle tracking, and X-ray identification necessary to distinguish rare antinucleus signals from the abundant positive-nucleus backgrounds, all within the constraints of a high-altitude mission. A multi-loop capillary heat pipe system has been developed to maintain the tracker operating temperature with significant mass and power savings over a conventional pump-based system. The first GAPS science payload flew for 25 days during the 2025/26 NASA Antarctic balloon campaign. We detail the design, integration, and commissioning of the payload prior to flight.

Aoyama, Kazutaka [JAXA, Sagamihara]↗

Design and Construction of a High-Resolution Hodoscope for the GlueX Experiment with High-Statistics Analysis of the p0, ¿, and ¿1 Photoproduction Cross Sections from the RadPhi Experiment

Differential cross sections for forward-angle photoproduction of p0, ¿, and ¿ 1 pseudoscalar mesons were measured using data from the RadPhi experiment conducted in Hall B at Jef ferson Lab. RadPhi utilized a tagged bremsstrahlung photon beam incident on a stationary 9Be target, with a detector system configured to trigger on a recoil proton in coincidence with multiple neutral showers in the calorimeter. Events were reconstructed and subjected to kinematic constraints, with background suppressed via sideband subtraction guided by Monte Carlo modeling of background contributions. Cross sections were extracted over the photon energy range 4.4– 5.4 GeV and binned in invariant momentum transfer t, providing measurements from one of the first high-statistics experiments of forward ¿ and ¿1 pro duction from a nuclear target at these energies. Acceptance corrections were applied using a detailed GEANT-based simulation of the detector geometry and response. The resulting cross sections are consistent with 2020 CLAS results, when scaled by the number of protons in beryllium, and show broad agreement with other data and theoretical models. In parallel, a high-resolution photon tagger detector, the Tagger Microscope (TAGM), was designed, constructed, and commissioned for the GlueX experiment in Hall D at Jefferson Lab. The TAGM was developed to provide high-rate tagging capability in the coherent bremsstrahlung peak by detecting post-bremsstrahlung electrons across a one GeV range along the focal plane of the tagging spectrometer. The detector consists of a 5ˆ102 array of 2ˆ2 mm2 square BCF-20 plastic scintillating fibers thermally fused to BCF-98 light guide fibers optically coupled to silicon photomultipliers. These fibers are mounted in a precision machined framework enabling fine positional adjustments to maintain precise alignment with post-bremsstrahlung electron trajectories, while ensuring mechanical rigidity, thermal stability, optical isolation, minimal inactive area, and radiation shielding for electronics. The construction effort involved extensive testing of fiber quality, light transmission, thermal fusing, radiation hardness, and defect analysis using SEM and EDX techniques. Following its installation and commissioning, the TAGM became a critical component of the GlueX beamline, enabling high-rate tagging essential for studies of hybrid mesons and gluonic ex citations.

McIntyre, James [Univ. of Connecticut, Storrs, CT ↗