Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plasma diodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Projected noise in submillimeter-wave mixers with InSb Schottky diodes

The reduction of the equivalent noise temperature in liquid-nitrogen-cooled submillimeter-wave mixers by the use of Schottky barriers on InSb instead of GaAs is evaluated by an analytical model that assumes limited local oscillator power and matched impedances. The calculations, executed at 1.0 and 1.8 THz, take plasma resonance and skin effect into account. For single and multiple contacts on homogeneous semiconductor materials of optimum doping, the noise of InSb diodes is smaller than that of GaAs diodes by a factor of 3 to 14. A simplified model is used to predict the performance of epitaxial structures as well as alternative materials.

Lieneweg, U.↗

Laser driven inertial fusion energy technology development

The future of Laser-Based Inertial fusion energy requires the development of efficient diode-pumped laser drivers that can be scaled to megajoule class output operating at ≥ 10-Hz repetition rate. ARPA-E requested a study of the range of possibilities for a 100kJ/10-Hz laser system with >15% wall-plug efficiency operating below 360 nm. The conceptual design of a compact, 1 kJ class module is presented and analyzed for performance relative to the objectives along with a roadmap to demonstrate the technology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical simulation of a relativistic magnetron using a fluid electron model

An approach to numerically modeling relativistic magnetrons, in which the electrons are represented with a relativistic fluid, is described. A principal effect in the operation of a magnetron is space-charge-limited (SCL) emission of electrons from the cathode. We have developed an approximate SCL emission boundary condition for the fluid electron model. This boundary condition prescribes the flux of electrons as a function of the normal component of the electric field on the boundary. Here we show the results of a benchmarking activity that applies the fluid SCL boundary condition to the one-dimensional Child–Langmuir diode problem and a canonical two-dimensional diode problem. Simulation results for a two-dimensional A6 magnetron are then presented. Computed bunching of the electron cloud occurs and coincides with significant microwave power generation. Numerical convergence of the solution is considered. Sharp gradients in the solution quantities at the diocotron resonance, spanning an interval of three to four grid cells in the most well-resolved case, are present and likely affect convergence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A time-resolved imaging system for the diagnosis of x-ray self-emission in high energy density physics experiments

A diagnostic capable of recording spatially and temporally resolved x-ray self-emission data was developed to characterize experiments on the MAGPIE pulsed-power generator. The diagnostic used two separate imaging systems: a pinhole imaging system with two-dimensional spatial resolution and a slit imaging system with one-dimensional spatial resolution. The two-dimensional imaging system imaged light onto the image plate. The one-dimensional imaging system imaged light onto the same piece of image plate and a linear array of silicon photodiodes. This design allowed the cross-comparison of different images, allowing a picture of the spatial and temporal distribution of x-ray self-emission to be established. The design was tested in a series of pulsed-power-driven magnetic-reconnection experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Many-Body Effects on Bandgap Shrinkage, Effective Masses, and Alpha Factor

Many-body Coulomb effects influence the operation of quantum-well (QW) laser diode (LD) strongly. In the present work, we study a two-band electron-hole plasma (EHP) within the Hatree-Fock approximation and the single plasmon pole approximation for static screening. Full inclusion of momentum dependence in the many-body effects is considered. An empirical expression for carrier density dependence of the bandgap renormalization (BGR) in an 8 nm GaAs/Al(0.3)G(4.7)As single QW will be given, which demonstrates a non-universal scaling behavior for quasi-two-dimension structures, due to size-dependent efficiency of screening. In addition, effective mass renormalization (EMR) due to momentum-dependent self-energy many-body correction, for both electrons and holes is studied and serves as another manifestation of the many-body effects. Finally, the effects on carrier density dependence of the alpha factor is evaluated to assess the sensitivity of the full inclusion of momentum dependence.

Li, Jian-Zhong↗

X-ray Lasers: The evolution from Star Wars to the table-top [PowerPoint]

X-ray lasers have evolved from a Star Wars missile defense system to a table-top research tool: (1) LLNL proposes X-ray laser schemes in the 1970’s, (2) First X-ray lasers demonstrated in early 1980’s were nuclear pumped, (3) Demonstrated the world’s shortest wavelength, highest energy laser, (4) First laboratory X-ray laser demonstrated on Novette in 1984, (5) A decade of progress using the Nova laser (5 kJ) from 1985 to 1996, (6) X-ray lasers produced at the COMET table-top facility (<10 J) since 1997, (7) X-ray lasers used for plasma interferometry and other applications, (8) 10 Hz X-ray laser at 18.9 nm demonstrated in 2004 using 0.15 J drive, (9) 100 Hz X-ray laser at 13.9 nm produces 1 µJ of saturated output using 0.9 J drive from diode-pumped optical laser in 2014.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-fidelity modeling of breakdown in helium: initiation processes and secondary electron emission

Understanding the role of physical processes contributing to breakdown is critical for many applications in which breakdown is undesirable, such as capacitors, and applications in which controlled breakdown is intended, such as plasma medicine, lightning protection, and materials processing. The electron emission from the cathode is a critical source of electrons which then undergo impact ionization to produce electrical breakdown. In this study, the role of secondary electron yields due to photons (γ ph ) and ions (γ i ) in direct current breakdown is investigated using a particle-in-cell direct simulation Monte Carlo model. The plasma studied is a one-dimensional discharge in 50 Torr of pure helium with a platinum cathode, gap size of 1.15 cm, and voltages of 1.2–1.8 kV. The current traces are compared with experimental measurements. Larger values of γ ph generally result in a faster breakdown, while larger values of γ i result in a larger maximum current. The 58.4 nm photons emitted from He(2 1 P) are the primary source of electrons at the cathode before the cathode fall is developed. Of the values of γ ph and γ i investigated, those which provide the best agreement with the experimental current measurements are γ ph = 0.005 and γ i = 0.01. In this work, these values are significantly lower than those in the literature for pristine platinum or for a graphitic carbon film which we speculate may cover the platinum. This difference is in part due to the limitations of a one-dimensional model but may also indicate surface conditions and exposure to a plasma can have a significant effect on the secondary electron yields. The effects of applied voltage and the current produced by a UV diode which was used to initiate the discharge, are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diode Laser Sensors for Arc-Jet Characterization

The development and application of tunable diode laser (TDL) absorption sensors to monitor the health and operating conditions in the large-scale 60 MW arc-heated- plasma wind-tunnel at NASA Ames Research Center is reported. The interactive heating facility (THF) produces re-entry flow conditions by expanding the gas heated in a constricted plasma arc-heater to flow at high velocity over a model located in a test cabin. This facility provides the conditions needed to test thermal protective systems for spacecraft re-entering the earth s atmosphere. TDL sensors are developed to monitor gas flows in both the high-temperature constricted flow and the supersonic expansion flow into test cabin. These sensors utilize wavelength-tuned diode lasers to measure absorption transitions of atomic oxygen near 777.2 nm, atomic nitrogen near 856.8 nm, and atomic copper near 793.3 nm. The oxygen and nitrogen sensors measure the population density in exited electronic states of these atoms. The measurements combined with the assumption of local thermal and chemical equilibrium yield gas temperature (typically near 7,000K). The nitrogen and oxygen population temperatures are redundant, and their close agreement provides an important test of the local thermal equilibrium assumption. These temperature sensors provide time-resolved monitors of the operating conditions of the arc-heater and can be used to verify and control the test conditions. An additional TDL sensor was developed to monitor the copper concentration in the arc-heater flow yielding values as high as 13 ppm. Measurements of copper in the flow can identify flow conditions with unacceptably rapid electrode erosion, and hence this sensor provides valuable information needed to schedule maintenance to avoid costly arc-heater failure. TDL sensors were also developed for measurements in the test cabin, where absorption measurements of the populations of argon and molecular nitrogen in excited metastable electronic states established that the number density of these excited species is much lower than estimated using frozen-chemistry approximations. This key finding suggests that in the post-expansion region there is not a significant energy sequestration in electronically excited species. Finally, TDL measurements of atomic potassium seeded into the test cabin flow were used to directly measure the static temperature of the test gas. The results of this study illustrate the high potential of time-resolved TDL measurements for routine and economical sensing of arc-heater health (gas temperature and electrode erosion) as well as the time-resolved test-cabin-flow conditions in front of the model.

Hanson, Ronald K.↗

High Voltage Regrown GaN P-N Diodes Enabled by Defect and Doping Control

This project studied and implemented methods to form GaN p-n diodes using selective area regrowth to achieve selective area doping. Successful selective area doping of GaN p-n diodes is an enabling factor to realize more advanced devices such as vertical transistors. The general challenge to selective area regrowth of GaN is that the primary etch method, inductively coupled plasma (ICP), damages the crystal and causes high leakage when didoes are formed by regrowth on the etched surface. Our approach used low damage etch methods following ICP etch to remove crystal damage and reduced leakage in the regrown diode. This project demonstrated 1.6 kV etched-and-regrown GaN p-n diodes using planar (non-selective) regrowth and 840 V etched-and-regrown p-n diodes using selective area regrown. Enabling factors were use of a low-damage reactive ion etch (RIE) to remove damage caused by the primary ICP etch combined with a multi-step junction terminal extension (JTE) process. Deep level defect investigation quantitatively correlated a deep level near the middle of the GaN band gap with ICP etch-induced leakage that was greatly mitigated by using a slow, low damage RIE process. This research is economically feasible for commercialization because the processes used in this project, including substrate type and source, epitaxial crystal growth and fabrication techniques are all standard to the GaN semiconductor industry. The fundamental understanding and foundational ability to produce kV-class GaN p-n diodes through etch-and-regrowth provides a path to realize high power, high efficiency GaN power switches that can significantly outperform commercial devices for next-generation electrical power conversion and transmission systems.

36 MATERIALS SCIENCE↗

DOE SCGSR Final Report - Project Accomplishments and Additional Materials

The major accomplishments of my project were successfully developing and testing the laser interferometry diagnostic on the Plasma Liner Experiment (PLX) at Los Alamos National Laboratory (LANL). This diagnostic helped advance my research by providing a simpler way to obtain electron density measurements of magnetized plasmas compared to other electron density diagnostics such as triple Langmuir probes. The laser used was a 561 nm continuous wave (CW) diode-pumped solid state (DPSS) laser. The PLX laser interferometry diagnostic consists of two parts. These include the launching and receiving sides of the laser diagnostic. The launching side consists of the main laser beam from the DPSS laser being split into five chords(probe beams) and a reference beam which are then directed with fiber optic couplers into fiber optic cables which transmit the probe beamsto the PLX vacuum chamber. The probe beams then pass through the plasma in the chamber and into the receiving side optics where they are again directed through fiber optic cables to be combined with the reference beam. The combined beams are transmitted via multi-mode fiber optic cables to photodiodes to convert the light signals into electrical signals. Before the electrical signals get digitized, they pass through bandpass and low pass filters to eliminate electromagnetic noise and unwanted frequencies. The electrical signals are then processed by IQ demodulators to determine phase angle difference between the probe and reference beams for each chord in order to calculate line-integrated electron density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Role of GaAs surface clearing in plasma deposition of silicon nitride films for encapsulated annealing

The role of GaAs surface cleaning and plasma reactor cleaning prior to deposition of silicon nitride films for encapsulated annealing has been investigated. X-ray photoelectron spectroscopy was employed to determine the surface characteristics of GaAs treated with HCl, HF, and NH4OH solutions preceded by a degreasing procedure. The HCl clean left the least amount of oxygen on the surface. Fluorine contamination resulting from the CF4 plasma used to clean the reactor was found to be located at the film-substrate interface by Auger electron spectroscopy with argon-ion sputtering. A modified deposition procedure was developed to eliminate the fluorine contamination. Plasma deposition of silicon nitride encapsulating films was found to modify the I-V characteristics of Schottky diodes subsequently formed on GaAs surface. The reverse current of the diodes was slightly reduced. Substrates implanted with Si at 100 keV and a dose of 5 x 10 to the 12th/sq cm showed a peak electron concentration of 1.7 x 10 to the 17th/cu cm at a depth of 0.1-micron with 60 percent activation after encapsulation and annealing at 800 C for 7 min.

Valco, G. J.↗

Wavelength modulation laser-induced fluorescence for plasma characterization

Laser-Induced Fluorescence (LIF) spectroscopy is an essential tool for probing ion and atom velocity distribution functions (VDFs) in complex plasmas. VDFs carry information about the kinetic properties of species that is critical for plasma characterization. Accurate interpretation of these functions is challenging due to factors such as multicomponent distributions, broadening effects, and background emissions. Our research investigates the use of Wavelength Modulation (WM) LIF to enhance the sensitivity of VDF measurements. Unlike standard Amplitude Modulation (AM) methods, WM–LIF measures the derivative of the LIF signal. This approach makes variations in VDF shape more pronounced. VDF measurements with WM–LIF were investigated with both numerical modeling and experimental measurements. The developed model enables the generation of both WM and AM signals, facilitating comparative analysis of fitting outcomes. Experiments were conducted in a weakly collisional argon plasma with magnetized electrons and non-magnetized ions. Measurements of the argon ion VDFs employed a narrow-band tunable diode laser, which scanned the 4p 4 D 7/2 –3d 4 F 9/2 transition centered at 664.553 nm in vacuum. A lock-in amplifier detected the second harmonic WM signal, which was generated by modulating the laser wavelength with an externally controlled piezo-driven mirror of the diode laser. Finally, our findings indicate that the WM–LIF signal is more sensitive to fitting parameters, allowing for better identification of VDF parameters such as the number of distribution components, their temperatures, and velocities. In addition, WM–LIF can serve as an independent method to verify AM measurements and is particularly beneficial in environments with substantial light noise or background emissions, such as those involving thermionic cathodes and reflective surfaces.

47 OTHER INSTRUMENTATION↗

The performance of Schottky diodes as far-infrared modulators

The performance as a THz-frequency modulator of a small-area Schottky diode mounted in a corner-cube antenna is evaluated, including the effects of carrier inertia and dielectric relaxation. Calculations are performed for a 1.4-micron diameter diode operating at a carrier frequency of 2.252 THz and a modulation frequency of 8 GHz. The phase modulation is found to completely dominate the amplitude modulation. The performance is shown to be degraded well below the plasma frequency in the undepleted epilayer due to the presence of a second resonance caused by the interaction of the barrier capacitance and the effective inductance due to carrier inertia. An increase in epilayer doping (reducing the diode radius) may improve the single-sideband conversion efficiency by about 20 dB.

Grossman, Erich N.↗

Plasma deposited silicon nitride for indium phosphide encapsulation

The composition and the annealing characteristics of plasma-deposited silicon-nitride encapsulating films on the ion-implanted InP substrates were investigated, using two different substrate-cleaning procedures (organic solvents and HF or HIO3 solutions) prior to encapsulation. The effect of plasma deposition of silicon nitride on the InP substrates was assessed through the current-voltage characteristics of Schottky diodes. Results of XPS analyses showed that the cleaning procedure that employed HF solution left less oxygen on the InP surface than the procedure involving HIO3. No chemical interaction between the film and the substrate was observed before or after annealing.

Valco, G. J.↗

Calibration of a versatile multi-energy soft x-ray diagnostic for WEST long pulse plasmas

A compact multi-energy soft x-ray diagnostic is being installed on the W Environment in Steady-state Tokamak (WEST), which was designed and built to test ITER-like tungsten plasma facing components in a long pulse (~1000 s) scenario. The diagnostic consists of a pinhole camera fielded with the PILATUS3 photon-counting Si-based detector (≲100 kpixel). The detector has sensitivity in the range 1.6–30 keV and enables energy discrimination, providing a higher energy resolution than conventional systems with metal foils and diodes with adequate space and time resolution (≲1 cm and 2 ms). The lower-absorption cut-off energy is set independently on each one of the ~100 kpixels, providing a unique opportunity to measure simultaneously the plasma emissivity in multiple energy ranges and deduce a variety of plasma parameters (e.g., T e , n Z , and ΔZ eff ). The energy dependence of each pixel is calibrated here over the range 3–22 keV. The detector is exposed to a variety of monochromatic sources—fluorescence emission from metallic targets—and for each pixel, the lower energy threshold is scanned to calibrate the energy dependence. The data are fit to a responsivity curve (“S-curve”) that determines the mapping between the possible detector settings and the energy response for each pixel. Here, the calibration is performed for three energy ranges: low (2.3–6 keV), medium (4.5–13.5 keV), and high (5.4–21 keV). We determine the achievable energy resolutions for the low, medium, and high energy ranges as 330 eV, 640 eV, and 950 eV, respectively. The main limitation for the energy resolution is found to be the finite width of the S-curve.

47 OTHER INSTRUMENTATION↗

NASA Tech Briefs, October 2010

Topics covered include: Hybrid Architecture Active Wavefront Sensing and Control; Carbon-Nanotube-Based Chemical Gas Sensor; Aerogel-Positronium Technology for the Detection of Small Quantities of Organic and/or Toxic Materials; Graphene-Based Reversible Nano-Switch/Sensor Schottky Diode; Inductive Non-Contact Position Sensor; High-Temperature Surface-Acoustic-Wave Transducer; Grid-Sphere Electrodes for Contact with Ionospheric Plasma; Enabling IP Header Compression in COTS Routers via Frame Relay on a Simplex Link; Ka-Band SiGe Receiver Front-End MMIC for Transponder Applications; Robust Optimization Design Algorithm for High-Frequency TWTs; Optimal and Local Connectivity Between Neuron and Synapse Array in the Quantum Dot/Silicon Brain; Method and Circuit for In-Situ Health Monitoring of Solar Cells in Space; BGen: A UML Behavior Network Generator Tool; Platform for Post-Processing Waveform-Based NDE; Electrochemical Hydrogen Peroxide Generator; Fabrication of Single, Vertically Aligned Carbon Nanotubes in 3D Nanoscale Architectures; Process to Create High-Fidelity Lunar Dust Simulants; Lithium-Ion Electrolytes Containing Phosphorous-Based, Flame-Retardant Additives; InGaP Heterojunction Barrier Solar Cells; Straight-Pore Microfilter with Efficient Regeneration; Determining Shear Stress Distribution in a Laminate; Self-Adjusting Liquid Injectors for Combustors; Handling Qualities Prediction of an F-16XL-Based Reduced Sonic Boom Aircraft; Tele-Robotic ATHLETE Controller for Kinematics - TRACK; Three-Wheel Brush-Wheel Sampler; Heterodyne Interferometer Angle Metrology; Aligning Astronomical Telescopes via Identification of Stars; Generation of Optical Combs in a WGM Resonator from a Bichromatic Pump; Large-Format AlGaN PIN Photodiode Arrays for UV Images; Fiber-Coupled Planar Light-Wave Circuit for Seed Laser Control in High Spectral Resolution Lidar Systems; On Calculating the Zero-Gravity Surface Figure of a Mirror; Optical Modification of Casimir Forces for Improved Function of Micro- and Nano-Scale Devices; Analysis, Simulation, and Verification of Knowledge-Based, Rule-Based, and Expert Systems; Core and Off-Core Processes in Systems Engineering; Digital Reconstruction Supporting Investigation of Mishaps; and Template Matching Approach to Signal Prediction.

Source record↗

Charge carrier motion and effect of fixed oxide charge in a microstructured silicon radiation detector

Signal formation in a microstructured semiconductor neutron detector is more complex than in planar diode geometry. Three-dimensional microstructures are laterally smaller than the ionization cloud length, and the electric fields may be weak enough to exhibit plasma time effects. This work is the first detailed treatment of charge carrier motion in these complex semiconductor devices to replicate the time profile and signal magnitude. Simulations were performed using COMSOL Multiphysics to investigate various parameters that affect the propagation of the charge cloud. It was observed that the size of the simulated three-dimensional structure had an impact on the induced current pulse, indicating the importance of simulation geometry optimization to accurately simulate charge cloud expansion. COMSOL Multiphysics was used to replicate accurate charge creation profiles using energy deposition information imported from radiation transport codes. A detailed simulation methodology is presented to benchmark preamplifier event pulses along with complexities in modeling the charge carrier motion along the etched microstructured trenches with Si–SiO 2 boundary conditions, including fixed oxide charge and interface trapping.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗