Interplanetary plasma electrons - A preliminary report of Pioneer 6 data.
Solar wind electron component detection by plasma experiment on Pioneer 6, particularly class 2B flare and quiet period
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Solar wind electron component detection by plasma experiment on Pioneer 6, particularly class 2B flare and quiet period
The Voyager 1 plasma wave instrument detected many familiar types of plasma waves during the encounter with Saturn, including ion-acoustic waves and electron plasma oscillations upstream of the bow shock, an intense burst of electrostatic noise at the shock, and chorus, hiss, electrostatic electron cyclotron waves, and upper hybrid resonance emissions in the inner magnetosphere. A clocklike Saturn rotational control of low-frequency radio emissions was observed, and evidence was obtained of possible control by the moon Dione. Strong plasma wave emissions were detected at the Titan encounter indicating the presence of a turbulent sheath extending around Titan, and upper hybrid resonance measurements of the electron density show the existence of a dense plume of plasma being carried downstream of Titan by the interaction with the rapidly rotating magnetosphere of Saturn.
A portable fluorescence biosensor with rapid and ultrasensitive response for trace protein has been built up with quantum dots and lateral flow test strip. The superior signal brightness and high photostability of quantum dots are combined with the promising advantages of lateral flow test strip and resulted in high sensitivity, selectivity and speedy for protein detection. Nitrated ceruloplasmin, a significant biomarker for cardiovascular disease, lung cancer and stress response to smoking, was used as model protein to demonstrate the good performances of this proposed Qdot-based lateral flow test strip. Quantitative detection of nitrated ceruloplasmin was realized by recording the fluorescence intensity of quantum dots captured on the test line. Under optimal conditions, this portable fluorescence biosensor displays rapid responses for nitrated ceruloplasmin in wide dynamic range with a detection limit of 0.1ng/mL (S/N=3). Furthermore, the biosensor was successfully utilized for spiked human plasma sample detection with the concentration as low as 1ng/mL. The results demonstrate that the quantum dot-based lateral flow test strip is capable for rapid, sensitive, and quantitative detection of nitrated ceruloplasmin and hold a great promise for point-of-care and in field analysis of other protein biomarkers.
Membrane associated nitrate reductase (NR) was detected in plasma membrane (PM) fractions isolated by aqueous two-phase partitioning from barley (Hordeum vulgare L. var CM 72) roots. The PM associated NR was not removed by washing vesicles with 500 millimolar NaCl and 1 millimolar EDTA and represented up to 4% of the total root NR activity. PM associated NR was stimulated up to 20-fold by Triton X-100 whereas soluble NR was only increased 1.7-fold. The latency was a function of the solubilization of NR from the membrane. NR, solubilized from the PM fraction by Triton X-100 was inactivated by antiserum to Chlorella sorokiniana NR. Anti-NR immunoglobulin G fragments purified from the anti-NR serum inhibited NO3- uptake by more than 90% but had no effect on NO2- uptake. The inhibitory effect was only partially reversible; uptake recovered to 50% of the control after thorough rinsing of roots. Preimmune serum immunoglobulin G fragments inhibited NO3- uptake 36% but the effect was completely reversible by rinsing. Intact NR antiserum had no effect on NO3- uptake. The results present the possibility that NO3- uptake and NO3- reduction in the PM of barley roots may be related.
Phenomena detected by the plasma wave instrument during the Voyager 2 flyby of Neptune are reviewed. Particular attention given to radio emissions, electron plasma oscillations in the solar wind upstream of the bow shock, electrostatic electron cyclotron waves and upper hybrid resonance (UHR) waves, whistler mode noise, and dust impacts. The radio emissions which occur in a broad range of about 5 to 50 kHz are considered to be generated by mode conversion from UHR waves at the magnetic equator. The inner magnetosphere has relatively low plasma wave intensities (less than 100 microV/m). Many small micron-sized dust particles which were detected striking the spacecraft had the maximum impact rate of about 280 impacts per sec at the bound ring plane crossing, and about 110 impacts per sec at the outbound ring plane crossing. Most of the particles were concentrated in a dense disk, about one thousand km thick, near the equatorial plane.
We have conducted calibrations of a microfission chamber, which was installed between the vacuum vessel and the toroidal field coils, by both a Cf-252 neutron source and real deuterium plasmas in JT-60U. The detector employs both pulse counting and Campbell (mean square voltage) modes in the electronics to cover a wide dynamic range of the neutron source strength. The pulse counting and Campbell modes were calibrated by Cf-252 and deuterium plasmas, respectively. Point efficiencies, counts per neutron from a point at a single angle, were measured for 27 locations of the neutron point source in toroidal scan. The efficiencies were influenced by the various components such as the vacuum vessel, port, and graphite tiles. The point efficiencies can be integrated and averaged with angle to provide toroidal line efficiencies. The line efficiencies of the microfission chamber and the nearest neutron monitor of the U-235 fission chamber were 5.38x10{sup -9} and 1.77x10{sup -8}, respectively. Then the calibration for the Campbell mode was also performed by using a real deuterium plasma. The detection efficiency in the Campbell mode was about three-tenths of that of the nearest neutron monitor, which is consistent with the calibration result obtained by using a Cf-252 neutron source for pulse counting mode.
Velocity sensing of hypervelocity particles was a significant field of interest from the 1960s to 1970s. Generically, velocity sensing has been approached by either of two methods: first, detecting direct plasma or light emissions onto a solid surface, or second, performing time-of-flight by film penetration, or by detecting charged particles passing a static electric field. Impact plasma techniques required the destruction of the particles. Multiple-film penetrations were also destructive, especially for small particles. There is a need for an integrated, reliable, and simple location and velocity sensor compatible to our intact capture underdense medium without contributing additional damage to the captured particle. Since cometary dust, like cosmic dust, is essentially randomly distributed, knowing the time of the dust capture and the location of the capture on the collector permits the identification of the specific dust particle captured. Velocity information helps to determine the trajectory of the dust particle. Our discovery of a very suitable acoustic sensor and fruitful experimental results have led to the realization of a flight velocity sensor with intact capture underdense media.
Asteroids contain a wealth of resources including water and precious metals that can be extracted. These resources could be applied to in-space manufacture of products that depend less on material launched from Earth's surface. The Meteoroid Impact Detection for Exploration of Asteroids (MIDEA) concept addresses the challenge of characterizing an asteroid surface using a small satellite with a constellation of free-flying plasma sensors to assess the asteroid’s viability for in situ resource utilization (ISRU). The plasma sensors detect ions ejected from the surface of an asteroid by meteoroid impacts, enabling the surface composition to be inferred. The objective of this NIAC Phase I study was to demonstrate feasibility of the MIDEA architecture in the context of proximity operations around an asteroid target and to develop the design of an orbital geometry and attitude control strategy for the ultralight plasma sensors. This was undertaken through a simulation framework to identify and characterize a favorable orbit for the MIDEA sensor constellation, and developing a sensor geometry that is consistent with maintaining the pointing requirements necessary to operate with sufficient power generation. Our study showed that a polar orbit aligned along the asteroid terminator provided sufficient stability for the sensors in the low gravitational environment under the influence of substantial solar radiation pressure. Reflector vanes using controlled reflectivity devices implemented with liquid crystal technology are capable of maintaining the sensor attitude so that it consistently points its solar panels in the sun direction and the sensor electrode at the asteroid surface. Finally, the reduction in meteoroid impact detection due to visibility constraints from the proposed orbit does not substantially extend the expected mission duration. These results indicate that the MIDEA concept can be achievable using a 10–20 kg spacecraft, which would be able to characterize the surface composition of an asteroid within 30–50 days of proximity operations. This architecture, implemented in parallel to multiple asteroid targets, would enable widespread exploration of near-Earth asteroids at low cost.
Development of a capability to measure trace gas contaminants released from pulsed power electrodes would immediately impact Sandia pulsed power research. These releases occur during ultra-fast heating of metal electrodes during pulsed power discharges and can lead to substantial power losses through plasma formation. Detection of contaminants is a formidable challenge due to the need for in-situ spatially and temporally resolved measurements of trace gases in the extreme environment of ultra-fast heated metal surfaces. We investigate the feasibility of laser diagnostics for detecting contaminants, including H-atom, OH, and H 2 O. Laser-induced fluorescence and photofragmentation fluorescence showed significant plasma emission interferences and did not yield any detectable H-atom, OH, or H 2 O. Our newly developed H-atom detection using femtosecond degenerate four-wave mixing suppressed interferences and enabled detection of H-atoms. A few shots showed large signals in the near-surface region of metal foils, suggesting the formation of a wave of H-atoms from the metal.
We used an electrostatic size classification technique to segregate particles of known composition prior to being injected into an inductively coupled plasma mass spectrometer (ICP-MS). Moreover, we counted size-segregated particles with a condensation nuclei counter as well as sampled with an ICP-MS. By injecting particles of known size, composition, and aerosol concentration into the ICP-MS, efficiencies of the order of magnitude aerosol detection were calculated, and the particle size dependencies for volatile and refractory species were quantified. Similar to laser ablation ICP-MS, aerosol detection efficiency was defined as the rate at which atoms were detected in the ICP-MS normalized by the rate at which atoms were injected in the form of particles. This method adds valuable insight into the development of technologies like laser ablation ICP-MS where aerosol particles (of relatively unknown size and gas concentration) are generated during ablation and then transported into the plasma of an ICP-MS. In this study, we characterized aerosol detection efficiencies of volatile species gold and silver along with refractory species aluminum oxide, cerium oxide, and yttrium oxide. Aerosols were generated with electrical mobility diameters ranging from 100 to 1000 nm. In general, it was observed that refractory species had lower aerosol detection efficiencies than volatile species, and there were strong dependencies on particle size and plasma torch residence time. Volatile species showed a distinct transition point at which aerosol detection efficiency began decreasing with increasing particle size. This critical diameter indicated the largest particle size for which complete particle detection should be expected and agreed with theories published in other works. Aerosol detection efficiencies also displayed power law dependencies on particle size. Aerosol detection efficiencies ranged from 10 -5 to 10 -11 . Free molecular heat and mass transfer theory was applied, but evaporative phenomena were not sufficient to explain the dependence of aerosol detection on particle diameter. Additional work is needed to correlate experimental data with theory for metal-oxides where thermodynamic property data are sparse relative to pure elements. Finally, when matrix effects and the diffusion of ions inside the plasma were considered, mass loading was concluded to have had an effect on the dependence of detection efficiency on particle diameter.
Highlights: • Phthalate metabolite levels in urine and seminal plasma were detected among 687 men. • Measures taken from urine samples poorly predicted same-day seminal plasma levels. • Metabolite levels varied according to sociodemographic and lifestyle factors. • Venous infusion was associated with higher levels of MBP and DEHP metabolites. Certain phthalates are suspected to be endocrine disruptors that are adversely associated with male reproductive health. However, the predictors and correlations of phthalate metabolite concentrations in urine and seminal plasma among reproductive-aged men have not been thoroughly studied.
In-plasma x-ray photoelectron spectroscopy (plasma-XPS) emerges as a powerful platform for real-time, in situ chemical analysis under conditions relevant to semiconductor processing and other plasma-enabled technologies. This study investigates the origins of binding energy (BE) shifts and the formation of “satellite” peaks observed during plasma-XPS measurements across conductive, dielectric, and gas-phase systems. Using a standard laboratory-based ambient pressure XPS apparatus coupled with an alternating current (AC)-driven capacitively coupled plasma source, we demonstrate that metastable surface species, such as transient Au oxides, can be detected during plasma exposure, revealing chemical states that are hardly accessible using conventional ultrahigh vacuum (UHV) XPS. In dielectric samples (e.g., undoped diamond, sapphire), we observe pressure- and plasma-type-dependent BE shifts of more than 50 eV, attributed to x-ray-induced and plasma-mediated surface charging. These shifts are mitigated at higher pressures/plasmas or in electronegative plasmas (e.g., O 2 ), the latter due to enhanced charge compensation mechanisms involving slow negative ions. For gas-phase species, AC-plasma excitation leads to spectral broadening and the emergence of “satellite” peaks with energy separations of a few electron volts, linked to oscillating local plasma potentials in the probing volume. Furthermore, these findings highlight the complex and important interplay between plasma parameters, surface charging, and local electric fields in shaping XPS spectra. Overall, plasma-XPS emerges as a critical metrological tool for probing transient surface chemistry, with implications for semiconductor processing, material synthesis, and plasma diagnostics.
Analysis of VLF emissions that have been observed near 3/2, 5/2, and 7/2 f sub H by Ogo 5 in the magnetosphere (f sub H is the electron cyclotron frequency) in the light of the mechanism used for the diffuse plasma resonance f sub Dn observed by Alouette 2 and Isis 1. The VLF emission is considered to be generated by nonlinear coupling mechanisms in certain portions of the observation as the f sub Dn is enhanced by its association with nonlinear wave-particle interaction of the electrostatic electron cyclotron harmonic wave, including the instability due to the nonlinear inverse Landau damping mechanism in the turbulence. The difference between the two observations is in the excitation mechanism of the turbulence; the turbulence in the plasma trough detected by Ogo 5 is due to natural origins, whereas the ionospheric topside sounder makes the plasma wave turbulence artificially by submitting strong stimulation pulses. Electron density values in the plasma trough are deduced by applying the f sub Dn-f sub N/f sub H relationship obtained from the Alouette 2 experiment as well as by applying the condition for the wave-particle nonlinear interactions. The electron density values reveal good agreement with the ion density values observed simultaneously by the highly sensitive ion mass spectrometer.
Despite significant advances in LC-MS based technologies, challenges remain in implementing a proteomics platform for routine clinical applications. These include the needed robustness as well as the sensitivity and dynamic range of detection to both effectively address extremely small tissue samples, for example microdissected or biopsy tissues, or high dynamic range samples, such as blood plasma. Other key components include providing the needed throughput to enable statistically meaningful number of analyses for clinical setting within a robust platform that utilizes effective quantitative approaches for high accuracy and reproducibility. This chapter describes the key components of a nanoLC- MS based technological approach that is designed to target these challenges by virtue of enhancing sensitivity, dynamic range coverage, and throughput, for the generation of robust quantitative measurements in support of clinical studies.
One of the main aims of Wendelstein 7-X (W7-X), an advanced stellarator, is to investigate the quasi-steady state operation of magnetic confinement devices for nuclear fusion, for which power exhaust is an important issue. A dominant fraction of the energy leaving from the confined plasma region will be removed by 10 so-called island divertor units, which are designed to sustain a maximum heat flux of up to 10 MWm –2 . An essential prerequisite for the safe operation of a steady-state device is automatic detection of hot spots and other abnormal events. Simple temperature limits in infrared (IR) thermographic images will not be enough on their own, because of plasma-generated surface coatings and other effects summarized in the following. To protect divertor elements from overheating, and to monitor power deposition onto the divertor elements, near real-time hotspot detection algorithms for the analysis of carbon plasma facing components (PFCs) were implemented and tested in the GLADIS facility.
Observation of an unusually complex sector boundary on Feb. 2, 1969. Within a single seven-hour period the Pioneer 9 magnetometer and plasma probe detected a reverse shock, a slow shock, and a conventional fast shock. During this interval the electron gyrofrequency and the ion plasma frequency each varied by more than a factor of 10, and the low-frequency (broadband and 400-Hz) electric field wave levels were high and variable. It is shown that, near the discontinuities, enhanced 400-Hz wave levels were not generally associated with field gradients or current layers, but elevated 400-Hz wave levels were detected when the ion density fell within a fairly well-defined window. This suggests that modes related to ion sound waves were detected, and the observations are assessed in terms of various theories for interplanetary wave generation.
Detection of high frequency turbulence of cosmic plasma
We review observations of nonlinear plasma waves detected by interplanetary spacecraft. For this paper we will focus primarily on the phase-steepened properties of such waves. Plasma waves at comet Giacobini-Zinner measured by the International Cometary Explorer (ICE), at comets Halley and Grigg-Skjellerup measured by Giotto, and interplanetary Alfven waves measured by Ulysses, will be discussed and intercompared.