Analysis of nodal coverage utilizing image guided radiation therapy for primary gynecologic tumor volumes

Purpose: To evaluate radiation dose delivered to pelvic lymph nodes, if daily Image Guided Radiation Therapy (IGRT) was implemented with treatment shifts based on the primary site (primary clinical target volume [CTV]). Our secondary goal was to compare dosimetric coverage with patient outcomes. Materials and methods: A total of 10 female patients with gynecologic malignancies were evaluated retrospectively after completion of definitive intensity-modulated radiation therapy (IMRT) to their pelvic lymph nodes and primary tumor site. IGRT consisted of daily kilovoltage computed tomography (CT)-on-rails imaging fused with initial planning scans for position verification. The initial plan was created using Varian's Eclipse treatment planning software. Patients were treated with a median radiation dose of 45 Gy (range: 37.5 to 50 Gy) to the primary volume and 45 Gy (range: 45 to 64.8 Gy) to nodal structures. One IGRT scan per week was randomly selected from each patient's treatment course and re-planned on the Eclipse treatment planning station. CTVs were recreated by fusion on the IGRT image series, and the patient's treatment plan was applied to the new image set to calculate delivered dose. We evaluated the minimum, maximum, and 95% dose coverage for primary and nodal structures. Reconstructed primary tumor volumes were recreated within 4.7% of initial planning volume (0.9% to 8.6%), and reconstructed nodal volumes were recreated to within 2.9% of initial planning volume (0.01% to 5.5%). Results: Dosimetric parameters averaged less than 10% (range: 1% to 9%) of the original planned dose (45 Gy) for primary and nodal volumes on all patients (n = 10). For all patients, ≥99.3% of the primary tumor volume received ≥ 95% the prescribed dose (V95%) and the average minimum dose was 96.1% of the prescribed dose. In evaluating nodal CTV coverage, ≥ 99.8% of the volume received ≥ 95% the prescribed dose and the average minimum dose was 93%. In evaluating individual IGRT sessions, we found that 6 patients had an estimated minimal nodal CTV dose less than 90% (range: 78 to 99%) of that planned. With a median follow-up of 42.5 months, 2 patients experienced systemic disease progression at an average of 19.6 months. One patient was found to have a local or regional failure with an average follow-up of 42 months. Conclusion: Using only 3 dimensional IGRT corrections in gynecological radiation allows excellent coverage of the primary target volume and good average nodal CTV coverage. If IGRT corrections are based on alignment to the primary tumor volume, and is only able to be corrected in 3 degrees, this can create situations in which nodal volumes may be under dosed. Utilizing multiple IGRT sessions appears to average out dose discrepancies over the course of treatment. The implication of underdosing in a single IGRT session needs further evaluation in future studies. Based on the concern of minimum dose to a nodal target volume, these findings may signal caution when using IGRT and IMRT in gynecological radiation patients. Possible techniques to overcome this situation may include averaging shifts between tumor and nodal volume, use of a treatment couch with 6° of freedom, deformable registration, or adaptive planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Patient-Specific Monte Carlo-Based Dose-Kernel Approach for Inverse Planning in Afterloading Brachytherapy

Purpose: Brachytherapy planning software relies on the Task Group report 43 dosimetry formalism. This formalism, based on a water approximation, neglects various heterogeneous materials present during treatment. Various studies have suggested that these heterogeneities should be taken into account to improve the treatment quality. The present study sought to demonstrate the feasibility of incorporating Monte Carlo (MC) dosimetry within an inverse planning algorithm to improve the dose conformity and increase the treatment quality. Methods and Materials: The method was based on precalculated dose kernels in full patient geometries, representing the dose distribution of a brachytherapy source at a single dwell position using MC simulations and the Geant4 toolkit. These dose kernels are used by the inverse planning by simulated annealing tool to produce a fast MC-based plan. A test was performed for an interstitial brachytherapy breast treatment using two different high-dose-rate brachytherapy sources: the microSelectron iridium-192 source and the electronic brachytherapy source Axxent operating at 50 kVp. Results: A research version of the inverse planning by simulated annealing algorithm was combined with MC to provide a method to fully account for the heterogeneities in dose optimization, using the MC method. The effect of the water approximation was found to depend on photon energy, with greater dose attenuation for the lower energies of the Axxent source compared with iridium-192. For the latter, an underdosage of 5.1% for the dose received by 90% of the clinical target volume was found. Conclusion: A new method to optimize afterloading brachytherapy plans that uses MC dosimetric information was developed. Including computed tomography-based information in MC dosimetry in the inverse planning process was shown to take into account the full range of scatter and heterogeneity conditions. This led to significant dose differences compared with the Task Group report 43 approach for the Axxent source.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biological Treatment Planning for Tumor Therapy with Carbon Ions

Treatment planning for carbon ion therapy requires careful consideration and quantification of the biological effect of heavy ions. Since the radiation damage invoked by swift heavy particles considerably differs from that of photons, the relative biological effectiveness (RBE) must be taken into account to determine the relevant biologically equivalent dose. The RBE depends on many different parameters, such as the dose level, the ion species and energy as well as the biological endpoint. Currently, the Local Effect Model (LEM) developed at GSI is the only model that is used for treatment planning which takes these dependences into account. Here, we introduce the main ideas of the LEM and present its recent developments, which result in a better model accuracy when compared to experimental data. Further, we present the implementation of the LEM into the treatment planning software and discuss the potential advantages of carbon ions compared to conventional and proton irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-110: MRI-Guided Single-Session Simulation, Online Adaptation, and Treatment

Purpose: To develop a combined simulation and treatment workflow for MRI-guided radiation therapy using the ViewRay treatment planning and delivery system. Methods: Several features of the ViewRay MRIdian planning and treatment workflows are used to simulate and treat patients that require emergent radiotherapy. A simple “pre-plan” is created on diagnostic imaging retrieved from radiology PACS, where conformal fields are created to target a volume defined by a physician based on review of the diagnostic images and chart notes. After initial consult in radiation oncology, the patient is brought to the treatment room, immobilized, and imaged in treatment position with a volumetric MR. While the patient rests on the table, the pre-plan is applied to the treatment planning MR and dose is calculated in the treatment geometry. After physician review, modification of the plan may include updating the target definition, redefining fields, or re-balancing beam weights. Once an acceptable treatment plan is finalized and approved, the patient is treated. Results: Careful preparation and judicious choices in the online planning process allow conformal treatment plans to be created and delivered in a single, thirty-minute session. Several advantages have been identified using this process as compared to conventional urgent CT simulation and delivery. Efficiency gains are notable, as physicians appreciate the predictable time commitment and patient waiting time for treatment is decreased. MR guidance in a treatment position offers both enhanced contrast for target delineation and reduction of setup uncertainties. The MRIdian system tools designed for adaptive radiotherapy are particularly useful, enabling plan changes to be made in minutes. Finally, the resulting plans, typically 6 conformal beams, are delivered as quickly as more conventional AP/PA beam arrangements with comparatively superior dose distributions. Conclusion: The ViewRay treatment planning software and delivery system can accommodate a fast simulation and treatment workflow.

60 APPLIED LIFE SCIENCES↗

SU-F-T-65: AutomaticTreatment Planning for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

Purpose: High dose rate (HDR) brachytherapy treatment planning is conventionally performed in a manual fashion. Yet it is highly desirable to perform computerized automated planning to improve treatment planning efficiency, eliminate human errors, and reduce plan quality variation. The goal of this research is to develop an automatic treatment planning tool for HDR brachytherapy with a cylinder applicator for vaginal cancer. Methods: After inserting the cylinder applicator into the patient, a CT scan was acquired and was loaded to an in-house developed treatment planning software. The cylinder applicator was automatically segmented using image-processing techniques. CTV was generated based on user-specified treatment depth and length. Locations of relevant points (apex point, prescription point, and vaginal surface point), central applicator channel coordinates, and dwell positions were determined according to their geometric relations with the applicator. Dwell time was computed through an inverse optimization process. The planning information was written into DICOM-RT plan and structure files to transfer the automatically generated plan to a commercial treatment planning system for plan verification and delivery. Results: We have tested the system retrospectively in nine patients treated with vaginal cylinder applicator. These cases were selected with different treatment prescriptions, lengths, depths, and cylinder diameters to represent a large patient population. Our system was able to generate treatment plans for these cases with clinically acceptable quality. Computation time varied from 3–6 min. Conclusion: We have developed a system to perform automated treatment planning for HDR brachytherapy with a cylinder applicator. Such a novel system has greatly improved treatment planning efficiency and reduced plan quality variation. It also served as a testbed to demonstrate the feasibility of automatic HDR treatment planning for more complicated cases.

60 APPLIED LIFE SCIENCES↗

Postmastectomy Electron Beam Chest Wall Irradiation in Women With Breast Cancer: A Clinical Step Toward Conformal Electron Therapy

Purpose: Electron beam radiotherapy of the chest wall with or without lymph node irradiation has been used at the Institut Curie for >20 years. The purpose of this report was to show the latest improvements of our technique developed to avoid hot spots and improve the homogeneity. Methods and Materials: The study was split into two parts. A new electron irradiation technique was designed and compared with the standard one (dosimetric study). The dose distributions were calculated using our treatment planning software ISIS (Technologie Diffusion). The dose calculation was performed using the same calculation parameters for the new and standard techniques. Next, the early skin toxicity of our new technique was evaluated prospectively in the first 25 patients using Radiation Therapy Oncology Group criteria (clinical study). Results: The maximal dose found on the five slices was 53.4 {+-} 1.1 Gy for the new technique and 59.1 {+-} 2.3 Gy for the standard technique. The hot spots of the standard technique plans were situated at the overlap between the internal mammary chain and chest wall fields. The use of one unique field that included both chest wall and internal mammary chain volumes solved the problem of junction. To date, 25 patients have been treated with the new technique. Of these patients, 12% developed Grade 0, 48% Grade 1, 32% Grade 2, and 8% Grade 3 toxicity. Conclusions: This report describes an improvement in the standard postmastectomy electron beam technique of the chest wall. This new technique provides improved target homogeneity and conformality compared with the standard technique. This treatment was well tolerated, with a low rate of early toxicity events.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AAPM recommendations on dose prescription and reporting methods for permanent interstitial brachytherapy for prostate cancer: Report of Task Group 137

During the past decade, permanent radioactive source implantation of the prostate has become the standard of care for selected prostate cancer patients, and the techniques for implantation have evolved in many different forms. Although most implants use {sup 125}I or {sup 103}Pd sources, clinical use of {sup 131}Cs sources has also recently been introduced. These sources produce different dose distributions and irradiate the tumors at different dose rates. Ultrasound was used originally to guide the planning and implantation of sources in the tumor. More recently, CT and/or MR are used routinely in many clinics for dose evaluation and planning. Several investigators reported that the tumor volumes and target volumes delineated from ultrasound, CT, and MR can vary substantially because of the inherent differences in these imaging modalities. It has also been reported that these volumes depend critically on the time of imaging after the implant. Many clinics, in particular those using intraoperative implantation, perform imaging only on the day of the implant. Because the effects of edema caused by surgical trauma can vary from one patient to another and resolve at different rates, the timing of imaging for dosimetry evaluation can have a profound effect on the dose reported (to have been delivered), i.e., for the same implant (same dose delivered), CT at different timing can yield different doses reported. Also, many different loading patterns and margins around the tumor volumes have been used, and these may lead to variations in the dose delivered. In this report, the current literature on these issues is reviewed, and the impact of these issues on the radiobiological response is estimated. The radiobiological models for the biological equivalent dose (BED) are reviewed. Starting with the BED model for acute single doses, the models for fractionated doses, continuous low-dose-rate irradiation, and both homogeneous and inhomogeneous dose distributions, as well as tumor cure probability models, are reviewed. Based on these developments in literature, the AAPM recommends guidelines for dose prescription from a physics perspective for routine patient treatment, clinical trials, and for treatment planning software developers. The authors continue to follow the current recommendations on using D{sub 90} and V{sub 100} as the primary quantities, with more specific guidelines on the use of the imaging modalities and the timing of the imaging. The AAPM recommends that the postimplant evaluation should be performed at the optimum time for specific radionuclides. In addition, they encourage the use of a radiobiological model with a specific set of parameters to facilitate relative comparisons of treatment plans reported by different institutions using different loading patterns or radionuclides.

61 RADIATION PROTECTION AND DOSIMETRY↗

Intermediate energy photons (1 MV) to improve dose gradient, conformality, and homogeneity: Potential benefits for small field intracranial radiosurgery

A previously conceived and demonstrated principle of reducing penumbra for small radiosurgical dose fields is here now applied to a multiple beam arrangement in a stereotactic head phantom. In this work it is found that the fourfold reduction in radiological penumbra of small, single 1 MV x-ray fields translates to a more conformal, homogeneous dose distribution in the more complex beam arrangements. The film dosimetry is conducted with a high resolution digital microscope to quantify the sharp dose gradients. Further, the Gafchromic EBT film measurements in phantom are compared to calculations using the Xknife RT3 (Radionics, Burlington, MA) treatment planning software (TPS) with modeled 1 MV beam data. An orthogonal pair of coplanar beams and an 18-beam coplanar arc irradiation both yielded agreement between the modeling within the TPS and the film work. Conventional 6 MV modality is compared alongside 1 MV throughout. The 90%-50% and 90%-10% dose gradients at the intersection of the orthogonal beam pair were 1.7 and 4.7 mm for 6 MV versus 0.5 and 1.3 mm for 1 MV for an identical setup. The 18-beam coplanar arc plan yielded 90%-80% and 90%-50% dose gradients of 0.84 and 2.2 mm for 6 MV versus gradients of 0.29 and 1.36 mm for 1 MV for the midaxial slice coplanar with all beamlet axes. Uncertainties in gradient measurements were {+-}0.15 mm. The 18-beam coplanar beam arrangement represented a worst case scenario for penumbra overlap deteriorating the dose distribution. In brief, 1 MV x-rays provided superior homogeneity, conformality, and dose fall-off to 6 MV for the irradiations examined.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-D-213-05: Design, Evaluation and First Applications of a Off-Site State-Of-The-Art 3D Dosimetry System

Purpose: To design, construct and commission a prototype in-house three dimensional (3D) dose verification system for stereotatic body radiotherapy (SBRT) verification at an off-site partner institution. To investigate the potential of this system to achieve sufficient performance (1mm resolution, 3% noise, within 3% of true dose reading) for SBRT verification. Methods: The system was designed utilizing a parallel ray geometry instigated by precision telecentric lenses and an LED 630nm light source. Using a radiochromic dosimeter, a 3D dosimetric comparison with our gold-standard system and treatment planning software (Eclipse) was done for a four-field box treatment, under gamma passing criteria of 3%/3mm/10% dose threshold. Post off-site installation, deviations in the system’s dose readout performance was assessed by rescanning the four-field box irradiated dosimeter and using line-profiles to compare on-site and off-site mean and noise levels in four distinct dose regions. As a final step, an end-to-end test of the system was completed at the off-site location, including CT-simulation, irradiation of the dosimeter and a 3D dosimetric comparison of the planned (Pinnacle{sup 3}) to delivered dose for a spinal SBRT treatment(12 Gy per fraction). Results: The noise level in the high and medium dose regions of the four field box treatment was relatively 5% pre and post installation. This reflects the reduction in positional uncertainty through the new design. This At 1mm dose voxels, the gamma pass rates(3%,3mm) for our in-house gold standard system and the off-site system were comparable at 95.8% and 93.2% respectively. Conclusion: This work will describe the end-to-end process and results of designing, installing, and commissioning a state-of-the-art 3D dosimetry system created for verification of advanced radiation treatments including spinal radiosurgery.

60 APPLIED LIFE SCIENCES↗

3D tomodosimetry using long scintillating fibers: A feasibility study

Purpose: 3D dosimetry is recognized as an ideal for patient-specific quality assurance (QA) of highly conformal radiotherapy treatments. However, existing 3D dosimeters are not straightforward to implement in the clinic, as their read-out procedure is often tedious and their accuracy, precision, and/or sample size exhibit limitations. The purpose of this work is to develop a 3D dosimeter based on the concept of tomodosimetry inside concentric cylindrical planes using long scintillating fibers for the QA of modern radiotherapy techniques such as intensity-modulated radiation therapy (IMRT) or intensity-modulated arc therapy (IMAT).Methods: Using a model-based simulation, scintillating fibers were modeled on three concentric cylindrical planes of radii 2.5, 5.0, and 7.5 cm, inside a 10 cm radius water-equivalent cylinder phantom. The phantom was set to rotate around its central axis, made parallel to the linac gantry axis of rotation. Light acquisitions were simulated using the calculated dose from the treatment planning software and reconstructed in each cylindrical plane at a resolution of 1 mm{sup 2} using a total-variation minimization iterative reconstruction algorithm. The 3D dose was then interpolated from the reconstructed cylindrical plane doses at a resolution of 1 mm{sup 3}. Different scintillating fiber patterns were compared by varying the angle of each fiber in its cylindrical plane and introducing a light-tight cut in each fiber. The precision of the reconstructed cylindrical dose distribution was evaluated using a Poisson modeling of the acquired light signals and the accuracy of the interpolated 3D dose was evaluated using an IMRT clinical plan for a prostate case.Results: Straight scintillating fiber patterns with light-tight cuts were the most accurate in cylindrical dose reconstruction, showing less than 0.5 mm distance-to-agreement in dose gradients and a mean local dose difference of less than 0.2% in the high dose region for a 10 × 10 cm{sup 2} field. The precision attained with this fiber configuration was less than 0.9% in the high dose, low gradient region of an IMRT segment for light acquisitions of 0.1 MU over a 360 degree rotation of the cylinder phantom. 3D dose interpolation for the IMRT clinical plan yielded an overall dose difference with the reference input of less than 1%, except in high dose gradients.Conclusions: Using long scintillating fibers inside rotating, concentric cylindrical planes, the authors demonstrate that their tomodosimetry method has the potential for high resolution, precise, and accurate 3D dosimetry. Moreover, because of its water-equivalence and rotational symmetry, this design should find interesting application for both treatment QA and machine commissioning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The use of subchondral bone topography to approximate the center of rotation of the elbow joint in dogs

Abstract Objectives The aim of this study was to compare the approximate center of rotation in normal and diseased elbows in dogs. Study design Cross‐sectional study Sample population Computer tomography scans of nine dogs with unilateral fragmented medial coronoid process (FMCP). Methods A board certified radiologist confirmed that each dog had unilateral FMCP, and a normal contralateral elbow. Digital 3D models of all elbow joints were uploaded into a surgical planning software package. Four axes approximating the center of rotation (COR) of elbow joints were generated using five geometric shapes based on subchondral topography of the humeral condyle radius and ulna. Images showing the locations where axes exited the medial and lateral cortex of the humeral condyle were captured and imported into a second software package, for measurement of distances between exit points and the origin of a system of axes. Results In normal joints 20/27 (74%) axes exited the medial cortex, and 25/27 (93%) axes exited the lateral cortex cranial and distal to the medial and lateral epicondyles, respectively. In diseased joints 22/27 (81%) axes exited medial cortex and 19/27 (70%) axes exited the lateral cortex, caudal and distal to the medial and lateral epicondyles, respectively. Conclusion Based on CT‐ derived geometry, the COR of elbow affected with FMCP was generally more caudal than normal. Clinical significance External landmarks approximating the location of the elbow COR are provided, and while not validated, may assist in planning, creation, and assessment of procedures for FMCP.

Berger, Chen↗

SU-E-T-366: Clinical Implementation of MR-Guided Vaginal Cylinder Brachytherapy

Purpose: To evaluate the accuracy of MR-based vaginal brachytherapy source localization using an in-house MR-visible marker versus the alignment of an applicator model to MR images. Methods: Three consecutive patients undergoing vaginal HDR brachytherapy with a plastic cylinder were scanned with both CT and MRI (including T1- and T2- weighted images). An MR-visible source localization marker, consisting of a sealed thin catheter filled with either water (for T2 contrast) or Gd-doped water (for T1 contrast), was assembled shortly before scanning. Clinically, the applicator channel was digitized on CT with an x-ray marker. To evaluate the efficacy of MR-based applicator reconstruction, each MR image volume was aligned locally to the CT images based on the region containing the cylinder. Applicator digitization was performed on the MR images using (1) the MR visible marker and (2) alignment of an applicator surface model from Varian's Brachytherapy Planning software to the MRI images. Resulting source positions were compared with the original CT digitization. Results: Although the source path was visualized by the MR marker, the applicator tip proved difficult to identify due to challenges in achieving a watertight seal. This resulted in observed displacements of the catheter tip, at times >1cm. Deviations between the central source positions identified via aligning the applicator surface model to MR and using the xray marker on CT ranged from 0.07 – 0.19 cm and 0.07 – 0.20 cm on T1- weighted and T2-weighted images, respectively. Conclusion: Based on the current study, aligning the applicator model to MRI provides a practical, current approach to perform MR-based brachytherapy planning. Further study is needed to produce catheters with reliably and reproducibly identifiable tips. Attempts are being made to improve catheter seals, as well as to increase the viscosity of the contrast material to decrease fluid mobility inside the catheter.

60 APPLIED LIFE SCIENCES↗

MO-A-BRD-07: Feasibility of X-Ray Acoustic Computed Tomography as a Tool for Calibration and In Vivo Dosimetry of Radiotherapy Electron and Photon Beams

Purpose: This work simulates radiation-induced acoustic waves to assess the feasibility of x-ray acoustic computed tomography (XACT) as a dosimeter. XACT exploits the phenomenon that acoustic waves with amplitude proportional to the dose deposited are induced following a radiation pulse. After detecting these acoustic waves with an ultrasound transducer, an image of the dose distribution can be reconstructed in realtime. Methods: Monte Carlo was used to simulate the dose distribution for monoenergetic 6 MeV photon and 9 MeV electron beams incident on a water tank. The dose distribution for a prostate patient planned with a photon 4-field box technique was calculated using clinical treatment planning software. All three dose distributions were converted into initial pressure distributions, and transportation of the induced acoustic waves was simulated using an open-source toolkit. Ideal transducers were placed around the circumference of the target to detect the acoustic waves, and a time reversal reconstruction algorithm was used to obtain an XACT image of the dose for each radiation pulse. Results: For the photon water tank relative dosimetry case, it was found that the normalized acoustic signal amplitude agreed with the normalized dose at depths from 0 cm to 10 cm, with an average percent difference of 0.5%. For the reconstructed in-plane dose distribution of an electron water tank irradiation, all pixels passed a 3%–3 mm 2D gamma test. The reconstructed prostate dose distribution closely resembled the plan, with 89% of pixels passing a 3%–3 mm 2D gamma test. For all situations, the amplitude of the induced acoustic waves ranged from 0.01 Pa to 1 Pa. Conclusion: Based on the amplitude of the radiation-induced acoustic waves and accuracy of the reconstructed dose distributions, XACT is a feasible technique for dosimetry in both calibration and in vivo environments for photon and electron beams and merits further investigation. Funding from NSERC, CIHR and McGill University. SH acknowledges partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290)

60 APPLIED LIFE SCIENCES↗

Improvements in dose calculation accuracy for small off-axis targets in high dose per fraction tomotherapy

Purpose: A recent field safety notice from TomoTherapy detailed the underdosing of small, off-axis targets when receiving high doses per fraction. This is due to angular undersampling in the dose calculation gantry angles. This study evaluates a correction method to reduce the underdosing, to be implemented in the current version (v4.1) of the TomoTherapy treatment planning software. Methods: The correction method, termed 'Super Sampling' involved the tripling of the number of gantry angles from which the dose is calculated during optimization and dose calculation. Radiochromic film was used to measure the dose to small targets at various off-axis distances receiving a minimum of 21 Gy in one fraction. Measurements were also performed for single small targets at the center of the Lucy phantom, using radiochromic film and the dose magnifying glass (DMG). Results: Without super sampling, the peak dose deficit increased from 0% to 18% for a 10 mm target and 0% to 30% for a 5 mm target as off-axis target distances increased from 0 to 16.5 cm. When super sampling was turned on, the dose deficit trend was removed and all peak doses were within 5% of the planned dose. For measurements in the Lucy phantom at 9.7 cm off-axis, the positional and dose magnitude accuracy using super sampling was verified using radiochromic film and the DMG. Conclusions: A correction method implemented in the TomoTherapy treatment planning system which triples the angular sampling of the gantry angles used during optimization and dose calculation removes the underdosing for targets as small as 5 mm diameter, up to 16.5 cm off-axis receiving up to 21 Gy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-388: Evaluation of Electronic Brachytherapy Dose Distributions in Tissue Equivalent Materials

Purpose: To study the measured and calculated dose distributions for electronic brachytherapy (EBT) in various tissue equivalent homogenous materials. Methods: Calculated dose distributions in water were generated using published TG-43 parameters in Varian BrachyVision software for a 50 kVp, 50 cm Xoft source. Dose distributions were measured within a 3D-scanning tank using dosimeters including: PTW 0.125 cc, pin-point, and parallel-plate ion chambers, Sun Nuclear “Edge” diode and Gafchromic EBT3 film. Multi-channel film dosimetry was used in film analysis. EBT3 film curves were calibrated via radial dose comparison to both independently measured and published data. The resulting film calibration was utilized to measure dose distributions created by titanium filtered source utilized in clinical brachytherapy applications. Data was collected within homogenous PMMA, vinyl, polystyrene, paraffin, and water-equivalent plastic phantoms. Results: Ion-chamber data was corrected to effective points of measurement and normalized prior to comparison between calculated and measured dose distributions. Measurements made in water and water equivalent materials compared well with results from treatment planning software. The maximum percent differences (relative to water) observed between 1 cm and 3.5 cm depth from source for each of the phantom materials are as follows: PMMA 35%, polystyrene 41%, plastic-water 23%, vinyl 115%, and paraffin 46%. Conclusion: The increased probability of photoelectric interactions occurring within the patient during electronic brachytherapy will emphasize the radiological differences between varying human tissues in dose deposition. These differences can Result in clinically significant dose perturbations and it is therefore recommended to move to a model based dose calculation, as outlined in TG-186, to improve the dosimetric accuracy of low energy EBT.

60 APPLIED LIFE SCIENCES↗

SU-E-T-253: Development of a GDPM Monte Carlo Based Quality Assurance Tool for Cyberknife

Purpose: To develop a 3D quality assurance (QA) tool for Cyberknife plans using a GPU-based Monte Carlo dose calculation package, gDPM. The developed QA tool will be used as a secondary check for Cyberknife treatment planning software (TPS) reported dose distributions. Methods: Phase space files of the 5, 7.5, 10, 15, and 60 mm iris cones were downloaded from IAEA phase-space database. From the 60mm iris cone phase space file, we were able to generate raw phase space files for all other cones using a particle rejection method. The particles in the raw phase space files were binned with respect to the radial position and energy for commissioning. During the commissioning process, gDPM calculated percent depth dose and off-center ratios which were compared to those measured in the Blue Phantom. The off-axis data was measured with an SAD setup at depths of 15, 50, 100, 200, and 300 mm. At the commissioning stage, an optimization problem was solved to adjust the binned particles weights to minimize the difference between the calculated and measured ones. Commissioning validations will be performed by measuring point dose data of patient specific plans delivered to water phantoms. With commissioned phase space files, 3D patient-specific dose distributions will be calculated and compared against TPS reported dose. Results: Beyond the initial buildup region, the root mean square difference between the calculated and measured percent depth dose differences was less than 0.5%. The full-width half-max data from the off-axis ratio calculations was found to be within 0.1 mm of the measured data. Conclusion: Our current work showed excellent agreement between the gDPM calculated dose and the measured data for all cone sizes and types for the Cyberknife system. Implementation of a fast and accurate QA tool for patient specific plans will be feasible with this tool.

60 APPLIED LIFE SCIENCES↗

Use of Respiratory-Correlated Four-Dimensional Computed Tomography to Determine Acceptable Treatment Margins for Locally Advanced Pancreatic Adenocarcinoma

Purpose: Respiratory-induced excursions of locally advanced pancreatic adenocarcinoma could affect dose delivery. This study quantified tumor motion and evaluated standard treatment margins. Methods and Materials: Respiratory-correlated four-dimensional computed tomography images were obtained on 30 patients with locally advanced pancreatic adenocarcinoma; 15 of whom underwent repeat scanning before cone-down treatment. Treatment planning software was used to contour the gross tumor volume (GTV), bilateral kidneys, and biliary stent. Excursions were calculated according to the centroid of the contoured volumes. Results: The mean +- standard deviation GTV excursion in the superoinferior (SI) direction was 0.55 +- 0.23 cm; an expansion of 1.0 cm adequately accounted for the GTV motion in 97% of locally advanced pancreatic adenocarcinoma patients. Motion GTVs were generated and resulted in a 25% average volume increase compared with the static GTV. Of the 30 patients, 17 had biliary stents. The mean SI stent excursion was 0.84 +- 0.32 cm, significantly greater than the GTV motion. The xiphoid process moved an average of 0.35 +- 0.12 cm, significantly less than the GTV. The mean SI motion of the left and right kidneys was 0.65 +- 0.27 cm and 0.77 +- 0.30 cm, respectively. At repeat scanning, no significant changes were seen in the mean GTV size (p = .8) or excursion (p = .3). Conclusion: These data suggest that an asymmetric expansion of 1.0, 0.7, and 0.6 cm along the respective SI, anteroposterior, and medial-lateral directions is recommended if a respiratory-correlated four-dimensional computed tomography scan is not available to evaluate the tumor motion during treatment planning. Surrogates of tumor motion, such as biliary stents or external markers, should be used with caution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-252: An Investigation of Gamma Knife Frame Definition Error When Using a Pre-Planning Workflow

Purpose: To determine causal factors related to high frame definition error when treating GK patients using a pre-planning workflow. Methods: 160 cases were retrospectively reviewed. All patients received treatment using a pre-planning workflow whereby stereotactic coordinates are determined from a CT scan acquired after framing using a fiducial box. The planning software automatically detects the fiducials and compares their location to expected values based on the rigid design of the fiducial system. Any difference is reported as mean and maximum frame definition error. The manufacturer recommends these values be less than 1.0 mm and 1.5 mm. In this study, frame definition error was analyzed in comparison with a variety of factors including which neurosurgeon/oncologist/physicist was involved with the procedure, number of post used during framing (3 or 4), type of lesion, and which CT scanner was utilized for acquisition. An analysis of variance (ANOVA) approach was used to statistically evaluate the data and determine causal factors related to instances of high frame definition error. Results: Two factors were identified as significant: number of post (p=0.0003) and CT scanner (p=0.0001). Further analysis showed that one of the four scanners was significantly different than the others. This diagnostic scanner was identified as an older model with localization lasers not tightly calibrated. The average value for maximum frame definition error using this scanner was 1.48 mm (4 posts) and 1.75 mm (3 posts). For the other scanners this value was 1.13 mm (4 posts) and 1.40 mm (3 posts). Conclusion: In utilizing a pre-planning workflow the choice of CT scanner matters. Any scanner utilized for GK should undergo routine QA at a level appropriate for radiation oncology. In terms of 3 vs 4 post, it is hypothesized that three posts provide less stability during CT acquisition. This will be tested in future work.

60 APPLIED LIFE SCIENCES↗