Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Passive Monitors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Silicon Carbide Passive Temperature Sensors at INL

Discuss the SiC passive thermometry methods currently performed at INL and ORNL, decide on best path forward for establishing an ASTM Standard for processing SiC temperature monitors, and expand this ASTM benchmarking efforts to international collaborators (Netherlands, Canada, and Poland).

36 MATERIALS SCIENCE↗

Chapter 10 Supplement. Environmental Monitoring Technologies and Techniques for Detecting Interactions of Marine Animals with Marine Renewable Energy Devices

The Chapter 10 Supplementary Material provides information on instrument classes used for monitoring marine renewable energy devices such as passive acoustics, active acoustics, and video cameras. It also describes the applications and challenges of video cameras, and provides a technical glossary related to monitoring terminologies.

47 OTHER INSTRUMENTATION↗

Field Test Bed for Vadose-Zone Monitoring Approaches - 20404

In the Central Plateau at the U.S. Department of Energy Hanford Site, a large inventory of contaminants resides in unsaturated sediments within the approximately 100-meter-thick vadose zone, posing a potential continuing risk to groundwater. Vadose zone remedies used to address these contaminants will require performance monitoring to provide feedback during implementation and for long-term verification that remedial action objectives have been met. Passive approaches may also need long-term monitoring to demonstrate that the flux of contaminants from the vadose zone to the groundwater are below thresholds established to meet groundwater protection goals. Collection of physical (e.g., groundwater or sediment) samples is a common method for identifying contaminant concentration distributions, but this approach is limited by the number of locations and the frequency with which data can be collected. In situ vadose zone measurements have evolved over the past few years to include key measurements of water content, soil water pressure, temperature, and chemical concentration. However, the current generation of sensors is designed for relatively short-term use in near-surface soils or sediments. Geophysical methods have been evolving but are also limited in that they have not been designed for the specific long-term vadose zone monitoring needs at the Hanford Site. Overall, monitoring under unsaturated conditions can be difficult due to the need to install and maintain instrumentation over a large area and depth and the need to identify preferential flow pathways due to geologic and chemical heterogeneities over long periods. Thus, a vadose zone monitoring test bed was initiated to address these challenges and identify cost-effective approaches for implementation and postclosure monitoring of the deep vadose zone. The monitoring test bed is expected to provide valuable field-scale information for the design of vadose zone monitoring systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Systematic Operating Temperature Differences Between Al-BSF, PERC, and PERT-With-Optimized-Rear-Reflector Solar Mini-Modules Due to Rear Reflectance

Reflecting sub-bandgap light from photovoltaic modules has the potential to improve lifetime energy generation of fielded systems by reducing operating temperature. In this article, the temperature of fielded aluminum back-surface field (Al-BSF) and passivated emitter and rear contact (PERC) mini-modules was monitored every 5 minutes for 75 days along with corresponding meteorological data. Additionally, passivated emitter rear totally diffused (PERT) mini-modules with high-performance sub-bandgap rear reflectors were tested and compared to the state-of-the-art industrial modules. These reflectors consisted of a >300-nm-thick silicon dioxide nanoparticle film with a low refractive index. The impact of reflectance on measured operating temperature was isolated with a previously developed thermal model and quantified as the reflectance-induced median temperature difference between each tested module at representative outdoor conditions (1000 W m -2 , 25 degrees C ambient temperature, and 1.43 m s -1 wind speed). We found that, because of their reflectance differences, PERC modules ran systematically cooler than Al-BSF modules by 1.0 degrees C, whereas the PERT-with-optimized-rear-reflector systematically operated 1.4 degrees C cooler than the Al-BSF module and 0.4 degrees C than the PERC module. We also found that the rear reflector provided the greatest temperature benefit during periods of highest irradiance.

14 SOLAR ENERGY↗

Adaptable Monitoring Package Development and Deployment: Lessons Learned for Integrated Instrumentation at Marine Energy Sites

Integrated instrumentation packages are an attractive option for environmental and ecological monitoring at marine energy sites, as they can support a range of sensors in a form factor compact enough for the operational constraints posed by energetic waves and currents. Here we present details of the architecture and performance for one such system—the Adaptable Monitoring Package—which supports active acoustic, passive acoustic, and optical sensing to quantify the physical environment and animal presence at marine energy sites. we describe cabled and autonomous deployments and contrast the relatively limited system capabilities in an autonomous operating mode with more expansive capabilities, including real-time data processing, afforded by shore power or in situ power harvesting from waves. Across these deployments, we describe sensor performance, outcomes for biological target classification algorithms using data from multibeam sonars and optical cameras, and the effectiveness of measures to limit biofouling and corrosion. On the basis of these experiences, we discuss the demonstrated requirements for integrated instrumentation, possible operational concepts for monitoring the environmental and ecological effects of marine energy converters using such systems, and the engineering trade-offs inherent in their development. Overall, we find that integrated instrumentation can provide powerful capabilities for observing rare events, managing the volume of data collected, and mitigating potential bias to marine animal behavior. These capabilities may be as relevant to the broader oceanographic community as they are to the emerging marine energy sector.

16 TIDAL AND WAVE POWER↗

Gamma-Ray Imaging to Monitor Accumulating Holdup

Over time, nuclear materials can accumulate in process equipment and keeping track of such material is of interest to many stakeholder communities including safeguards, process monitoring, criticality safety, and radiological safety. Passive gamma-ray imaging provides a visual and quantitative tool that can be applied to this problem, allowing one to determine the amount of material present from the images. In this work we emulate the accumulation of highly enriched uranium (HEU) in a large rectangular stainless-steel duct by stacking 5, 27 × 50 cm2 cards, each of which has approximately 11 g of 235U in oxide form distributed across its surface, behind each other. A series of images were collected using a coded-aperture gamma-ray imager, starting with a single card, adding a second card, etc. Long integrations were collected to allow evaluating the performance of the approach as a function of integration time. The images are analyzed using first principles to determine the amount of material in each image. The results are compared to the known amount of material in each configuration, and as a function of time. The analysis includes a first-principles error propagation and to further evaluate the uncertainty, a boot-strap sampling approach is also applied to the data. The work offers a proof of concept for unattended monitoring of uranium holdup with a quantitative gamma-ray imaging technique.

Ziock, Klaus-Peter↗

Classification of animal sounds in a hyperdiverse rainforest using convolutional neural networks with data augmentation

To protect tropical forest biodiversity, we need to be able to detect it reliably, cheaply, and at scale. Automated detection of sound producing animals from passively recorded soundscapes via machine-learning approaches is a promising technique towards this goal, but it is constrained by the necessity of large training data sets. Using soundscapes from a tropical forest in Borneo and a Convolutional Neural Network model (CNN), we investigate i) the minimum viable training data set size for accurate prediction of call types (‘sonotypes’), and ii) the extent to which data augmentation and transfer learning can overcome the issue of small and imbalanced training data sets. We found that even relatively high sample sizes (>80 per sonotype) lead to mediocre accuracy, which however improved significantly with data augmentation and transfer learning, including at extremely small sample sizes (3 per sonotype), regardless of taxonomic group or call characteristics. Neither transfer learning nor data augmentation alone achieved high accuracy. Our results suggest that transfer learning and data augmentation could make the use of CNNs to classify species’ vocalizations feasible even for small soundscape-based projects with many rare species. Retraining our open-source model requires only basic programming skills which makes it possible for individual conservation initiatives to match their local context, in order to enable more evidence-informed management of biodiversity.

54 ENVIRONMENTAL SCIENCES↗

Applying Acoustic Emission to Large Format Additive Manufacturing

Large format additive manufacturing (AM) is being adapted as a method of producing large structures in a short lead time and cost-effective way. With the growing advancement in AM techniques and application, machine monitoring and part qualification is highly needed. There has been leading research focused on the manufacturing development and feedstock material but minimum research on the structural health monitoring (SHM), defect detection, and nondestructive evaluation (NDE) for large format AM. Scanning large structure using conventional nondestructive testing (NDT) techniques, such as ultrasound or X-ray, and searching for potential defects can be very time consuming, challenging and cost prohibitive. Acoustic emission (AE) is a passive technique that can be used to monitor and locate defect progression in large structures by distributing group of sensors around the part. This research outlines the necessary procedure for implementing AE to AM as a reliability method. The topics this research will display are: (a) Wave propagation/velocity evaluation, (b) an AE attenuation characterization for the anisotropic printed structure and material, (c) background noise measurements of the extruder and gantry system, and (d) assist in optimal sensor selection and placement for monitoring large AM structures with demonstration. This work establishes the foundation for scaling up the SHM-AE system for the large additive platform.

Spencer, Ryan↗

Passive Low-Energy Nuclear-Recoil Detection with Color Centers

Crystal-damage events such as tracks and point defects have been used to record and detect radiation for a long time and recently they have been proposed as a means for dark-matter detection. Color centers can be read out optically and we propose a scheme based on selective plane illumination microscopy for micrometer-scale imaging of large volumes corresponding to kilogram mass detectors. This class of detectors would be passive and would operate at room temperature and we call this the passive low-energy optical color-center nuclear-recoil (PALEOCCENE) detection method. We apply these concepts to the detection of reactor neutrinos using coherent elastic neutrino nucleus scattering (CE ν NS). Crystal-damage formation energies are intrinsically on the order of 25 eV, resulting in similarly low nuclear-recoil thresholds. Furthermore, this would enable the observation of reactor-neutrino CE ν NS with detectors as small as 10 g. Additionally, a competitive search for spin-dependent dark-matter scattering down to a dark-matter mass of 0.3 GeV could be possible. Passive crystal detectors might also be attractive for nuclear-nonproliferation safeguards if used to monitor reactor power and to put limits on plutonium production. The passive nature and small footprint of the proposed detectors implies that these might fit well within accepted reactor-safeguards operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In-Process Monitoring and Structural Health Monitoring of Large-Scale Additive Manufacturing Using Acoustic Emission Technique

ORNL collaborated with MISTRAS Group, Inc. to investigate acoustic emission (AE) as a structural health monitoring (SHM) method for large-scale additive manufacturing (AM). Large-scale AM is being adapted as method of producing large structures in a short lead time and cost-effective way. With the growing advancement in AM techniques and application, machine monitoring and part qualification is highly needed. There has been leading research focused on the manufacturing, feedstock material but minimum research on the SHM, defect detection, and nondestructive evaluation (NDE) for AM. Scanning large structure using conventional nondestructive testing (NDT) techniques, such as ultrasound or X-ray, and searching for potential defects can be very time consuming, challenging and cost prohibitive. AE is a passive technique that can be used to monitor and locate defect progression in large structure by distributing group of sensors around the part. This project utilized AE technique and system manufactured/designed by MISTRAS Group to monitor large-scale AM equipment (i.e. Big Area Additive Manufacturing (BAAM) system located at the Oak Ridge National Laboratory – Manufacturing Demonstration Facility (ORNL-MDF) and the printed parts it produces. The AE system provided valuable insight on defect development/progression during and post-printing process.

36 MATERIALS SCIENCE↗

The Incorporation of Pump-and-Treat Data in the New Tracking Restoration and Closure (TRAC)Web-Based Mapping Tool - 20339

Groundwater pump-and-treat (P and T) systems are a common remediation strategy for sites with contaminated groundwater within the U.S. Department of Energy (DOE) Office of Environmental Management (EM). Currently, there are six DOE-EM sites with active P and T systems, but integrated information on individual systems is only primarily available in separate annual reports. To provide a broad view of both current and historical P and T operations, data has been collected on all of the P and T systems. This summary information not only includes capital and average annual costs, but also identifies contaminants treated and forecasted P and T closure dates. Principal contaminants of concern treated with P and T systems include trichloroethylene, chromium (VI), strontium-90, technetium-99, and uranium. DOE-EM is continuing to create a web-based mapping tool that compiles information on groundwater contaminants, remediation strategies and, current data related to plumes and cleanup progress within all DOE-EM sites. The information collected on P and T systems will be added to the TRAC (Tracking Restoration and Closure) tool using interactive maps to quickly access and share information. This information sharing supports the transition from active to passive remediation methods and long-term monitoring approaches. TRAC can ensure that managers, stakeholders, regulators, and contractors remain up to date on cleanup progress for all sites within the complex. The information on P and T systems expands the use of TRAC and can assist in project monitoring and budget planning and support potential shifts in management plans based on plume data. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Comparison of Groundwater Sampling Technologies, Including Passive Diffusion Sampling, for Radionuclide Contamination - 20205

Using traditional high-flow purge methods for long-term water quality monitoring of deep groundwater wells can be expensive, affect contaminant migration, and produce excessive volumes of discharge water that can be difficult to manage. The use of low-flow pumping methods and depth discrete bailers (DDBs) can reduce the cost of sampling deep groundwater wells. In general, using different pumping methods to obtain reproducible and representative groundwater can be challenging. Passive diffusion samplers (PDSs) have successfully been used in long-term monitoring for volatile organic compounds, major ions, and trace-elements, but application has been limited for stable and radioactive isotopes. Beginning in 2018, the United States Geological Survey (USGS) conducted three sampling events to test the ability of PDSs and DDBs to obtain reproducible and representative groundwater samples. The sampled well is completed in a regional, permeable carbonate aquifer and is one in a set of wells that have historically been used for tritium tracer testing. All samples were obtained at 180 m (590 ft) below land surface (bls) in a 13.97 cm (5.5 inch) uncased well that has a total depth of 202 m (662 ft) bls. The first sampling event deployed a regenerated cellulose dialysis membrane (RCDM) PDS for 14 days with deionized water as the blank. The second sampling event deployed a RCDM for 27 days also with deionized water as the blank. The third sampling event deployed a Dual Membrane (DM) PDS for 65 days using a blank of tritium-dead carbonate water. The DM PDS was used to assess the effect of longer term deployment on tritium concentrations and address whether or not the PDSs reached equilibrium with ambient groundwater. The day after each of the three passive samplers were retrieved a DDB was used to obtain discrete non-integrated groundwater samples. For each DDB sampling day, the bailer was lowered into the well 10 consecutive times to determine if the water chemistry changed from the first to the last bailed sample. Quality assurance samples including blanks and duplicates were obtained during all three sampling events. All blank waters had tritium concentrations less than 21±33 pCi/L. Major ion (e.g. calcium, chloride, sodium, and sulfate) results were compared between all samples obtained with RCDM and DDB. Major ion concentrations showed a coefficient of variation of less than 6% between all RCDM and DDB samples; however, the coefficient of variation between the different deployment times and the two different methods for trace-element concentrations was much larger, particularly for manganese (82%), lead (41%), and zinc (33%). Stable isotope values were compared between the RCDM and DDB samples. The DDB sample results all fell within analytical uncertainty and were considered representative of the formation groundwater. The stable isotope values from the RCDM samples indicated that a longer deployment time was necessary to gain equilibrium and to obtain representative groundwater samples. Tritium results from groundwater samples obtained from the RCDM, DM, and DDB indicate that groundwaters obtained with PDSs produced tritium concentrations 2 to 3 times higher (between 1,426 and 3,060±87 pCi/L) than groundwaters obtained with a DDB (479 to 1,219±51 pCi/L). The longer the passive diffusion samplers were deployed, the higher the tritium concentration, suggesting that equilibrium with tritium was not reached within a 27-day deployment. DDB samples showed tritium results declining from the first to the last bailed sample for all three sampling events. This research suggests that tritium results from groundwater samples obtained from PDSs are more reproducible than samples obtained from DDBs. Also, PDSs likely do not accumulate isotopes of water but rather equilibrate with the ambient groundwater. On the other hand, both PDSs and DDBs were able to provide representative groundwater samples for major ions and have the potential to produce representative groundwater samples for stable isotopes of water (δD and δ{sup 18}O). Utilizing the most effective method for sampling groundwater is important for long-term groundwater monitoring. Quantifying the ability of passive diffusion groundwater samplers to obtain representative radioactive chemistry samples will help determine if these methods can be a useful alternative to pumping and purging wells for long-term monitoring. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Detecting fractures and monitoring hydraulic fracturing processes at the first EGS Collab testbed using borehole DAS ambient noise

Enhanced geothermal systems (EGS) require cost-effective monitoring of fracture networks. We validate the capability of using borehole distributed acoustic sensing (DAS) ambient noise for fracture monitoring using core photos and core logs. The EGS Collab project has conducted 10 m scale field experiments of hydraulic fracture stimulation using 50–60 m deep experimental wells at the Sanford Underground Research Facility (SURF) in Lead, South Dakota. The first EGS Collab testbed is located at 1616.67 m (4850 ft) depth at SURF and consists of one injection well, one production well, and six monitoring wells. All wells are drilled subhorizontally from an access tunnel called a drift. The project uses a single continuous fiber-optic cable installed sequentially in the six monitoring wells to record DAS data for monitoring hydraulic fracturing during stimulation. We analyze 60 s time records of the borehole DAS ambient noise data and compute the noise root-mean-square (rms) amplitude on each channel (points along the fiber cable) to obtain DAS ambient noise rms amplitude depth profiles along the monitoring wellbore. Our noise rms amplitude profiles indicate amplitude peaks at distinct depths. We compare the DAS noise rms amplitude profiles with borehole core photos and core logs and find that the DAS noise rms amplitude peaks correspond to the locations of fractures or lithologic changes indicated in the core photos or core logs. We then compute the hourly DAS noise rms amplitude profiles in two monitoring wells during three stimulation cycles in 72 h and find that the DAS noise rms amplitude profiles vary with time, indicating the fracture opening/growth or closing during the hydraulic stimulation. Our results demonstrate that borehole DAS passive ambient noise can be used to detect fractures and monitor fracturing processes in EGS reservoirs.

58 GEOSCIENCES↗

Unsupervised acoustic detection of fatigue-induced damage modes from wind turbine blades

This paper proposes a new in-situ damage detection approach for wind turbine blades, which leverages blade-internal non-stationary acoustic pressure fluctuations caused by the mechanical loading as the main source of excitation. This acoustic excitation was leveraged for the detection of fatigue-related damage modes on a full-scale wind turbine blade undergoing edgewise fatigue testing. An unsupervised, data-driven structural health monitoring strategy was developed to learn the normal cavity-internal acoustic sequences generated by the blade’s load cycles and to detect damage-related anomalies in the context of those sequences. A linear cepstral-coefficient based feature set was used to characterize the cavity-internal acoustics and LSTM-autoencoders were trained to accurately reconstruct healthy-case sequences. The reconstruction error was then used to characterize anomalous acoustic patterns within the blade cavity. The technique was able to detect a damage event earlier than a strain-based system by 120,000 load cycles.

17 WIND ENERGY↗

Hawaiian Hoary Bat Report for Sandia National Laboratories, Kauai Test Facility

The Hawaiian Hoary Bat Report for Sandia National Laboratories, Kauai Test Facility (SNL/KTF) provides data and analysis of Hawaiian hoary bat occupancy of the SNL/KTF site. The monitoring period was from 2023-2025 and used passive acoustic detection at three locations to determine whether the Hawaiian hoary bat occurs at the site and if they roost and pup in the vegetation of the site. Bats were detected at all three locations, however, given the vegetation type at SNL/KTF, it is very unlikely

Jones, Amanda Kaye [Sandia National Laboratories (↗

The passivity of low-temperature carburized austenitic stainless steel AISI-316L in a simulated boiling-water-reactor environment

The passive film on low-temperature-carburized AISI-316L austenitic stainless steel was studied in an oxygenated, simulated boiling-water-reactor environment with normal water chemistry. The microstructure was studied using scanning electron microscopy, grazing-incidence X-ray diffractometry, Auger electron spectroscopy, X-ray energy-dispersive spectroscopy, and transmission electron microscopy. For non-surface engineered AISI-316L, three distinct layers were observed after exposure: an outer layer of larger nickel-oxide enriched particles with the spinel structure, an intermediate layer of small Cr-oxide-enriched hematite particles, and a compact inner layer of Cr-enriched oxide also having the spinel structure. Exposure of low-temperature-carburized AISI-316L, in contrast, resulted in only two distinct layers. These layers did not include a compact Cr-rich inner layer. Instead, the innermost layer consisted of an oxide with the spinel structure that was a mixture of Fe, Cr and Ni oxide. The outer layer on the low-temperature-carburized specimen consisted of large loosely stacked particles with the spinel structure of mixed composition. In addition to passive-film characterization, the corrosion rate was studied by monitoring mass loss. Finally, after 500 h of immersion, the mass changes measured were relatively low for all specimens indicating good adhesion and low oxidation rates.

36 MATERIALS SCIENCE↗

Sandia Nuclear Cartridge Concept

Nuclear power offers the promise of long-term electrical power for remote areas. Recent advances in passive safety and long-life cores make a reactor that can be operated autonomously for 20 years or more a real possibility. This white paper discusses a reactor concept that offers the potential for further development, resulting in a permanently hermetically-sealed "nuclear cartridge." The term "nuclear cartridge" is meant to imply a nuclear energy source that can be inserted into a site and operated autonomously until its energy has been depleted, then withdrawn and replaced by another cartridge. The concept can be scaled for various sizes, ranging from about 1 megawatt-electric (MWe) to about 100 MWe. The paper also discusses the concept of Integrated Safety, Operations, Security, and Safeguards (ISOSS) by design as it applies to this reactor design. Finally, a discussion of smart grids and how they can benefit the transfer of power to the end user is included. The Nuclear Cartridge concept has been developed with the following characteristics in mind: highly reliable autonomous operation coupled with international monitoring, requiring minimal on-site operations personnel; walkaway passively safe design; cartridge replacement cycle on the order of 20 years; load following capability; physical security by design requiring minimal security personnel during operations; and proliferation resistance by design. As illustrated in figure 1, integrating the reactor with advanced power conversion, smart grids, and other sources of energy results in a resilient and sustainable energy source.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimizing aluminum oxide passivation layers—Laser-induced plasmas for layer formation, real-time diagnostics, and layer evaluation

Molten salts have beneficial thermophysical and electrolytic properties, but the aggressive nature of molten salts requires corrosion mitigation strategies, such as structural material surface treatment. In this study, a laser-induced breakdown spectroscopy (LIBS) system was used to simultaneously ablate and monitor de-excitation spectra to form and identify dense alumina passivation layers. Additionally, high-frequency (kHz) LIBS imaging allowed rapid elemental mapping and depth profiling for surface O/Al ratios via minimally destructive analysis. The paired t-test rejected the null hypothesis that air and Ar cover gases were equivalent (p = 0.00012), and the analysis of variance (ANOVA) showed that overlap between shots (p = 0.03112) and cover gas flow rate (p = 0.02729) were statistically significant. At 75% overlap, the O/Al ratio increased to 10% ± 2%, and 90% overlap rose further to 31% ± 2%. Regardless of overlap, tuning the gas flow from 0.5 to 2.5 L min −1 enhanced the O/Al ratio by 24% ± 4%. LIBS depth profiling showed a 3× increase in layer thickness from 75% to 90% overlap. Molecular band peaks of AlO, a precursor to Al 2 O 3 found during treatment, suggest that band intensity could be used for real-time Al 2 O 3 optimization. Ultimately, by adjusting laser spot overlap and cover gas flow rate, a 266 nm laser was shown to form Al 2 O 3 layers on an Al6061 sample, with cover gas flow rate primarily affecting the O/Al ratio and layer thickness correlating with laser spot overlap. This combination of molecular spectra collection, imaging, and depth profiling demonstrated the robust layer analysis capabilities of LIBS.

Corrosion↗