PV Field Performance Including Fleet and Bifacial Field Data

This presentation provides a review of two recent presentations - the 2021 PV Fleet Performance Data Initiative covered by the PVRW presentation, and bifacial system performance presented to a February DuraMAT working group. Details include degradation rate distributions from >6000 inverter channels, monthly performance vs expected, bifacial field studies of energy gain and field degradation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Utility-Scale Solar, 2024 Edition: Analysis of Empirical Plant-level Data from U.S. Ground-mounted PV, PV+battery, and CSP Plants (exceeding 5 MWAC)

Berkeley Labs "Utility-Scale Solar", 2024 Edition presents analysis of empirical plant-level data from the U.S. fleet of ground-mounted photovoltaic (PV), PV+battery, and concentrating solar-thermal power (CSP) plants with capacities exceeding 5 MWAC. While focused on key developments in 2023, this report explores trends in deployment, technology, capital and operating costs, capacity factors, the levelized cost of solar energy (LCOE), power purchase agreement (PPA) prices, wholesale market value, net value, and interconnection queue data.

analysis↗

Utility-Scale Solar, 2022 Edition: Analysis of Empirical Plant-level Data from U.S. Ground-mounted PV, PV+battery, and CSP Plants (exceeding 5 MWAC)

Berkeley Labs "Utility-Scale Solar", 2022 Edition presents analysis of empirical plant-level data from the U.S. fleet of ground-mounted photovoltaic (PV), PV+battery, and concentrating solar-thermal power (CSP) plants with capacities exceeding 5 MWAC. While focused on key developments in 2021, this report explores trends in deployment, technology, capital and operating costs, capacity factors, the levelized cost of solar energy (LCOE), power purchase agreement (PPA) prices, wholesale market value, and interconnection queue data.

2022↗

Utility-Scale Solar, 2023 Edition: Analysis of Empirical Plant-level Data from U.S. Ground-mounted PV, PV+battery, and CSP Plants (exceeding 5 MWAC)

Berkeley Labs "Utility-Scale Solar", 2023 Edition presents analysis of empirical plant-level data from the U.S. fleet of ground-mounted photovoltaic (PV), PV+battery, and concentrating solar-thermal power (CSP) plants with capacities exceeding 5 MWAC. While focused on key developments in 2022, this report explores trends in deployment, technology, capital and operating costs, capacity factors, the levelized cost of solar energy (LCOE), power purchase agreement (PPA) prices, wholesale market value, and interconnection queue data.

analysis↗

Photovoltaic fleet degradation insights

Abstract In the PV Fleet Performance Data Initiative, high‐frequency data from commercial and utility‐scale photovoltaic (PV) systems have been collected to examine performance loss rates (PLRs) at a fleet scale. To date, performance data from more than 7.2‐gigawatt (GW) capacity, 1700 sites and 19,000 inverters—approximately equivalent to 6% to 7% of the entire US PV market—have been collected. An overall PLR of −0.75%/year was found, which is in line with historical and recent findings. Tracked silicon (Si) and cadmium telluride (CdTe) performed comparably with all fixed‐tilt systems. Higher PLRs were found for hotter temperature zones; cooler climates exhibit a median −0.48%/year loss, which increases to −0.88%/year in hotter climates. High‐efficiency module technologies showed median PLRs in line with conventional Si technologies but demonstrated markedly different PLR behavior when filtered only for low‐light conditions <600 W/m 2 . Causes for this technology‐dependent behavior are under investigation.

14 SOLAR ENERGY↗

Segmentation of Deposition Periods: An Opportunity to Improve PV Soiling Extraction

Soiling profiles are commonly assumed to have sawtooth shapes, made of alternating cleaning events and soiling deposition periods. The rates at which soiling deposit on the PV modules are considered to be constant for each period. In reality, events such as changes in climatic conditions can lead to a sudden variation in soiling deposition rate. These changes cannot be reproduced if cleanings are the only events modelled to extract soiling profiles directly from PV performance data. For this reason, in this work, the use of change points and segmented regression is proposed to improve the extraction of soiling profiles through the model of up to two deposition rates per period in between cleanings. The results show that the quality of soiling extraction can be enhanced compared to a cleanings-only identification approach if both cleanings and change points are considered.

monitoring↗

Joint Estimation of Behind-the-Meter Solar Generation in a Community

Distribution grid planning, control, and optimization require accurate estimation of solar photovoltaic (PV) generation and electric load in the system. Most of the small residential solar PV systems are installed behind-the-meter making only the net load readings available to the utilities. This paper presents an unsupervised framework for joint disaggregation of the net load readings of a group of customers into the solar PV generation and electric load. Our algorithm synergistically combines a physical PV system performance model for individual solar PV generation estimation with a statistical model for joint load estimation. The electric loads for a group of customers are estimated jointly by a mixed hidden Markov model (MHMM) which enables modeling the general load consumption behavior present in all customers while acknowledging the individual differences. At the same time, the model can capture the change in load patterns over a time period by the hidden Markov states. The proposed algorithm is also capable of estimating the key technical parameters of the solar PV systems. Our proposed method is evaluated using the net load, electric load, and solar PV generation data gathered from residential customers located in Austin, Texas. Testing results show that our proposed method reduces the mean squared error of state-of-the-art net-load disaggregation algorithms by 67%.

behind-the-meter solar generation↗

PVCollada schema

SAND2025-11606O xml schema for PV uses Collada 1.4 schema to provide tag names and structures to allow PV software to exchange Collada files with PV-specific data. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Crosby, Sean↗

What's New in System Advisor Model

This talk will give an overview of recent and planned model improvements in the NLR System Advisor Model, including improved spectral model options, improved access to snow data for PV modeling across the United States, work on hybrid PV, CSP, and thermal energy storage modeling, current research into accurately modeling tandem cells, and more.

14 SOLAR ENERGY↗

Bifacial Photovoltaic Module Degradation Dynamics

In a comprehensive study conducted at NREL's 75 kW bifacial single-axis-tracked field, accelerated degradation was observed in four out of five bifacial silicon photovoltaic (PV) module technologies when compared to their monofacial counterparts. Root cause analysis of accelerated bifacial degradation involved various analytical tools and techniques. This included employing RdTools to identify rates of power loss, conducting measurements on fielded and control modules using infrared imaging, electroluminescence (EL) and photoluminescence (PL), quantum efficiency (QE) analysis, IV-curves assessment, as well as utilizing handheld Raman and reflectance measurement targeted at anti-reflective coating. Most cases pointed to carrier lifetime degradation causing Voc loss and simultaneous Isc loss. In some cases, Isc further decreases likely due to optical effects from encapsulant degradation. The outcomes and methodologies employed in this investigation are documented in this publication. This study's significance is further emphasized by placing the findings within the broader context of the performance and degradation of various bifacial systems, as identified in the PV Fleets data.

bifacial↗