Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE GAUGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Mean and fluctuating velocity contours and acoustic characteristics of subsonic and supersonic jets.

Mean and fluctuating velocity contours were determined for a convergent nozzle from surveys with impact pressure and piezoelectric pressure gauge probes, at Mach numbers of 0.6 to 1.4. For supersonic Mach numbers of 1.2 and 1.4, the length of the supersonic region increased as the square of the Mach number, and the peak pressure fluctuations occurred close to the sonic velocity contour. For subsonic Mach numbers of 0.6 to 1.0, the peak pressure fluctuations occurred in a toroidal region located approximately 4 to 6 diameters from the nozzle. The normalized sound power spectra for subsonic Mach numbers were similar, and for supersonic Mach numbers the power spectra shifted to the higher frequencies.

Nagamatsu, H. T.↗

Engine Cycle Analysis of Air Breathing Microwave Rocket with Reed Valves

The Microwave Rocket is a candidate for a low cost launcher system. Pulsed plasma generated by a high power millimeter wave beam drives a blast wave, and a vehicle acquires impulsive thrust by exhausting the blast wave. The thrust generation process of the Microwave Rocket is similar to a pulse detonation engine. In order to enhance the performance of its air refreshment, the air-breathing mechanism using reed valves is under development. Ambient air is taken to the thruster through reed valves. Reed valves are closed while the inside pressure is high enough. After the time when the shock wave exhausts at the open end, an expansion wave is driven and propagates to the thrust-wall. The reed valve is opened by the negative gauge pressure induced by the expansion wave and its reflection wave. In these processes, the pressure oscillation is important parameter. In this paper, the pressure oscillation in the thruster was calculated by CFD combined with the flux through from reed valves, which is estimated analytically. As a result, the air-breathing performance is evaluated using Partial Filling Rate (PFR), the ratio of thruster length to diameter L/D, and ratio of opening area of reed valves to superficial area {alpha}. An engine cycle and predicted thrust was explained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mesoscale Characterization of Coupled Hydromechanical Behavior of a Fractured Porous Slope in Response to Free Water-Surface Movement

To better understand the role of groundwater-level changes on rock-slope deformation and damage, a carbonate rock slope (30 m x 30 m x 15 m) was extensively instrumented for mesoscale hydraulic and mechanical measurements during water-level changes. The slope is naturally drained by a spring that can be artificially closed or opened by a water gate. In this study, a 2-hour slope-dewatering experiment was analyzed. Changes in fluid pressure and deformation were simultaneously monitored, both at discontinuities and in the intact rock, using short-base extensometers and pressure gauges as well as tiltmeters fixed at the slope surface. Field data were analyzed with different coupled hydromechanical (HM) codes (ROCMAS, FLAC{sup 3D}, and UDEC). Field data indicate that in the faults, a 40 kPa pressure fall occurs in 2 minutes and induces a 0.5 to 31 x 10{sup -6} m normal closure. Pressure fall is slower in the bedding-planes, lasting 120 minutes with no normal deformation. No pressure change or deformation is observed in the intact rock. The slope surface displays a complex tilt towards the interior of the slope, with magnitudes ranging from 0.6 to 15 x 10{sup -6} rad. Close agreement with model for both slope surface and internal measurements is obtained when a high variability in slope-element properties is introduced into the models, with normal stiffnesses of k{sub n{_}faults} = 10{sup -3} x k{sub n{_}bedding-planes} and permeabilities of k{sub h{_}faults} = 10{sup 3} x k{sub h{_}bedding-planes}. A nonlinear correlation between hydraulic and mechanical discontinuity properties is proposed and related to discontinuity damage. A parametric study shows that 90% of slope deformation depends on HM effects in a few highly permeable and highly deformable discontinuities located in the basal, saturated part of the slope while the remaining 10% are related to elasto-plastic deformations in the low-permeability discontinuities induced by complex stress/strain transfers from the high-permeability zones. The periodicity and magnitude of free water-surface movements cause 10 to 20% variations in those local stress/strain accumulations related to the contrasting HM behavior for high and low-permeable elements of the slope. Finally, surface-tilt monitoring coupled with internal localized pressure/deformation measurements appears to be a promising method for characterizing the HM properties and behavior of a slope, and for detecting its progressive destabilization.

54 ENVIRONMENTAL SCIENCES↗

Adrenergic responsiveness is reduced, while baseline cardiac function is preserved in old adult conscious monkeys

To examine the physiological deficit to adrenergic stimulation with aging, five younger adult (3 +/- 1 yr old) and nine older adult (17 +/- 1 yr old) healthy monkeys were studied after instrumentation with a left ventricular (LV) pressure gauge, aortic and left atrial catheters, and aortic flow probes to measure cardiac output directly. There were no significant changes in baseline hemodynamics in conscious older monkeys. For example, an index of contractility, the first derivative of LV pressure (LV dP/dt) was similar (3,191 +/- 240, young vs. 3,225 +/- 71 mmHg/s, old) as well as in isovolumic relaxation, tau (24.3 +/- 1.7 ms, young vs. 23.0 +/- 1.0 ms, old) was similar. However, inotropic, lusitropic, and chronotropic responses to isoproterenol (Iso; 0.1 micrograms/kg), norepinephrine (NE; 0.4 micrograms/kg), and forskolin (For; 75 nmol/kg) were significantly (P < 0.05) depressed in older monkeys. For example. Iso increased LV dP/dt by by 146 +/- 14% in younger monkeys and by only 70 +/- 5% in older monkeys. Iso also reduced tau more in younger monkeys (-28 +/- 7%) compared with older monkeys (-13 +/- 3%). Furthermore, peripheral vascular responsiveness to Iso, NE, For, and phenylephrine (PE; 5 micrograms/kg) was significantly (P < 0.05) reduced in older monkeys. For example, phenylephrine (5 micrograms/kg) increased total peripheral resistence by 69 +/- 4% in younger monkeys and by only 45 +/- 3% in older monkeys. Thus in older monkeys without associated cardiovascular disease, baseline hemodynamics are preserved, but adrenergic receptor responsiveness is reduced systemically, not just in the heart.

Non-NASA Center↗

Synthesis and Properties of the Helium Clathrate and Defect Perovskite [He 2– x $^\square$ x ][CaNb]F 6

The defect double perovskite [He 2– x $^\square$ x ][CaNb]F 6 , with helium on its A-site, can be prepared by the insertion of helium into ReO 3 -type CaNbF 6 at high pressure. Upon cooling from 300 to 100 K under 0.4 GPa helium, ~60% of the A-sites become occupied. Helium uptake was quantified by both neutron powder diffraction and gas insertion and release measurements. After the conversion of gauge pressure to fugacity, the uptake of helium by CaNbF 6 can be described by a Langmuir isotherm. The enthalpy of absorption for helium in [He 2– x $^\square$ x ][CaNb]F 6 is estimated to be ~+3(1) kJ mol –1 , implying that its formation is entropically favored. Helium is able to diffuse through the material on a time scale of minutes at temperatures down to ~150 K but is trapped at 100 K and below. The insertion of helium into CaNbF 6 reduces the magnitude of its negative thermal expansion, increases the bulk modulus, and modifies its phase behavior. On compressing pristine CaNbF 6 , at 50 and 100 K, a cubic (Fm$\overline{3}$m) to rhombohedral (R$\overline{3}$) phase transition was observed at <0.20 GPa. However, a helium-containing sample remained cubic at 0.4 GPa and 50 K. CaNbF 6 , compressed in helium at room temperature, remained cubic to >3.7 GPa, the limit of our X-ray diffraction measurements, in contrast to prior reports that upon compression in a nonpenetrating medium, a phase transition is detected at ~0.4 GPa.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Micro-Gas-Analyzer MEMS Active Pressure Valves Testing and Design

Micro-Gas-Analyzers have many applications in detecting chemical compounds present in the air. MEMS valves are used to perform sampling of gasses, as they enable control of fluid flow at the micro level. Current generation electrostatically actuated MEMS valves were tested to determine their ability to hold off a given gauge pressure with an applied voltage. Current valve designs were able to hold off 98 psi with only 82 V applied to the valves. The valves were determined to be 1.83 times more efficient than older valve designs, due to increasing the electrostatic area of the valve and trapping oxide between polysilicon layers. Newer valve designs were also proposed and modeled using ANSYS multiphysics, which should be able to hold off 100 psi with only 29 V needed. This performance would be 2.82 times more efficient than current designs, or 5.17 times more efficient than older valve designs. This will be accomplished by further increasing the valve radius and decreasing the gap between the valve boss and electrode.

42 ENGINEERING↗

Characterization of unsaturated hydraulic conductivity in fractured media using the multistep outflow method - 15461

The multistep outflow method is routinely used to characterize the unsaturated hydraulic conductivity of soils. The technique involves placing a soil sample in a pressure plate apparatus, subjecting the sample to multiple gas pressures in discrete steps through time, and measuring the transient volume of pore fluid extracted. Unsaturated hydraulic property values are estimated through inverse modeling of the experimental conditions. In this study the multistep outflow concept was applied to micro-cracked cementitious materials to assess the efficacy of the technique for these materials. The cementitious materials tested were salt-waste simulant grout samples artificially damaged through oven-drying. Compared to typical soils, fractured media exhibit higher saturated conductivity and lower air-entry pressure, and the volume of fluid extractable from fractures is much lower than soil porosity. To accommodate these material differences the standard test apparatus was modified to incorporate a higher conductivity ceramic pressure plate, a high-precision digital balance for logging outflow mass, a low volume (diameter) effluent line, multiple in-line high-precision gas regulators, and a high-precision low-range pressure gauge. Testing to date indicates that the modified apparatus can provide a viable means to measure the unsaturated hydraulic properties of micro-fractured cementitious materials. However the accuracy/uniqueness of inverse modeling is limited by the inherent characteristics of fractured media: high saturated conductivity, low air-entry pressure, and strong non-linearities. Hydraulic property results in the form of van Genuchten / Mualem curves are presented for three fractured grout specimens. DOE Performance Assessments often involve cementitious barriers and/or waste forms that are predicted or assumed to degrade over time due to various mechanisms such as carbonation-influenced reinforcing steel corrosion, external sulfate attack, differential settlement, and seismic activity. Physical degradation typically takes the form of small-scale cracking / fracturing, and the affected materials reside in unsaturated hydrogeologic zones. In these cases, unsaturated hydraulic properties are needed for fractured cementitious materials to simulate moisture movement and contaminant transport within and around the facility. The outflow extraction method, as implemented in the present study, provides a suitable method for estimating these material properties. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Apparatus For Tests Of Embrittlement By Hydrogen

Test apparatus exposes disk specimens to hydrogen in controlled, repeatable way simulating conditions in use. Disk specimen constitutes thin wall between pressure and vacuum chambers. Test proceeds until hydrogen weakens disk enough that it ruptures. Aluminum impact plate absorbs debris from ruptured disk. Apparatus replicates aspects of service environments relevant to embrittlement by hydrogen in such equipment as storage tanks, valves, and fluid-handling components containing hydrogen at high absolute or gauge pressure. Hydrogen inside permeates stressed material and produces gradient of concentration as hydrogen diffuses through material to low-pressure side.

Christianson, Rollin C.↗

A cryogenic high pressure cell for inelastic neutron scattering measurements of quantum fluids and solids

We present our new development of a high pressure cell for inelastic neutron scattering measurements of helium at ultra-low temperatures. The cell has a large sample volume of ~140 cm3, and a working pressure of ~70 bar, with a relatively thin wall-thickness (1.1 mm) - thanks to the high yield strength aluminum used in the design. Two variants of this cell have been developed; one with permanently joined components using electron-beam welding and explosion welding, methods that have little or no impact on the global heat treatment of the cell, and another with modular and interchangeable components, which include a capacitance pressure gauge, that can be sealed using traditional indium wire technique. The performance of the cell has been tested in recent measurements on superfluid liquid helium near the solidification line.

Cryogenics↗

Measurements of Tc (Q,P): Depression of the Superfluid Transition Temperature by a Heat Current Along the Lambda Line

We report experimental measurements of Tc (Q,P) for heat currents (Q) between I1and 100 micro W/sq cm and pressure (P) between SVP and 15 bar. The measurements were performed in a normal gravity environment, using the low-gravity simulator facility at JPL without the magnet being energized. The sample pressure was controlled to 0.1 micro bar using a hot volume, and a Straty-Adams capacitive pressure gauge. The total volume of helium in the sample cell and the hot volume was held constant using a pneumatic low temperature valve. A melting curve thermometer (MCT) measured the transition temperature (Tc) with a resolution of about 10 nK through a sidewall probe of the thermal conductivity sample cell. We employed the same measurement technique and procedure described by DAS. Preliminary results indicate that Tc (Q,P) depends very little on the pressure in the pressure range between SVP and 15 bar with a variation in the amplitude of Tc(Q,P) of less than about 5% observable in this pressure range. According to the Renormalization-group theory calculation by Haussmann and Dohm, the amplitude of Tc (Q,P) has a leading pressure-dependence term proportional to xi(sub 0) (sup (1/nu)), where xi(sub 0) is the correlation-length amplitude and nu is the correlation-length exponent. Thus, a small pressure dependence of the amplitude of Tc (Q,P) is expected since xi(sub 0) is very weakly dependent on pressure between SVP and 15 bar, consistent with our measurements.

Liu, Yuan-Ming↗

Cubic boron nitride as a primary calibrant for a high temperature pressure scale

We present results establishing a new high pressure scale at high temperature based on the thermal equation of state and elastic properties of cubic boron nitride (cBN). This scale is derived from simultaneous measurements of density and sound velocities at high pressure and temperature independent of any previous pressure scale. The present results obtained at room temperature to 27 GPa suggest the validity of the current ruby scale (within {+-}4% at 100 GPa). At high temperature, data obtained at 16 GPa to 723 K are in fair agreement with the thermal equation of state of cBN reported in our previous work. We have also shown that cBN can serve as a convenient pressure gauge in X-ray and optical studies using the laser heated diamond anvil cell.

36 MATERIALS SCIENCE↗

Technical Capability Upgrades to the NASA Langley Research Center 6 ft. by 6 ft. Thermal Vacuum Chamber

The 6 ft. by 6 ft. thermal vacuum chamber (TVAC), housed in Building 1250 at the NASA Langley Research Center (LaRC), and managed by the Systems Integration and Test Branch within the Engineering Directorate, has undergone several significant modifications to increase testing capability, safety, and quality of measurements of articles under environmental test. Significant modifications include: a new nitrogen thermal conditioning unit for controlling shroud temperatures from -150degC to +150degC; two horizontal auxiliary cold plates for independent temperature control from -150degC to +200degC; a suite of contamination monitoring sensors for outgassing measurements and species identification; signal and power feed-throughs; new pressure gauges; and a new data acquisition and control commanding system including safety interlocks. This presentation will provide a general overview of the LaRC 6 ft. by 6 ft. TVAC chamber, an overview of the new technical capabilities, and illustrate each upgrade in detail, in terms of mechanical design and predicted performance. Additionally, an overview of the scope of tests currently being performed in the chamber will be documented, and sensor plots from tests will be provided to show chamber temperature and pressure performance with actual flight hardware under test.

Thornblom, Mark N.↗

Stress modeling of microdiaphragm pressure sensors

A finite element program analysis was used to model the stress distribution of two monocrystalline silicon diaphragm pressure sensors. One configuration consists of an anisotropically backside etched diaphragm into a 250 micron thick, (100) oriented, silicon wafer. The diaphragm and total chip dimensions are given. The device is rigidly clamped on the back to a support substrate. Another configuration consists of a monocrystalline, (100), microdiaphragm which is formed on top of the wafer and whose area is reduced by a factor of 25 over the first configuration. The diaphragm is rigidly clamped to the silicon wafer. The stresses were calculated at a gauge pressure of 300 mm Hg and used to estimate the piezoresistive responses of resistor elements which were placed parallel and perpendicular near the diaphragm edges.

Tack, P. C.↗

Integrated atom detector based on field ionization near carbon nanotubes

We demonstrate an atom detector based on field ionization and subsequent ion counting. We make use of field enhancement near tips of carbon nanotubes to reach extreme electrostatic field values of up to 9x10{sup 9} V/m, which ionize ground-state rubidium atoms. The detector is based on a carpet of multiwall carbon nanotubes grown on a substrate and used for field ionization, and a channel electron multiplier used for ion counting. We measure the field enhancement at the tips of carbon nanotubes by field emission of electrons. We demonstrate the operation of the field ionization detector by counting atoms from a thermal beam of a rubidium dispenser source. By measuring the ionization rate of rubidium as a function of the applied detector voltage we identify the field ionization distance, which is below a few tens of nanometers in front of nanotube tips. We deduce from the experimental data that field ionization of rubidium near nanotube tips takes place on a time scale faster than 10{sup -10} s. This property is particularly interesting for the development of fast atom detectors suitable for measuring correlations in ultracold quantum gases. We also describe an application of the detector as partial pressure gauge.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effect of outer divertor leg detachment on the high field side scrape-off layer in DIII-D and ASDEX Upgrade

In this work, evidence is presented that detachment of the outer divertor leg leads to a reduction of electron density and neutral pressure in the high-field side (HFS) scrape-off layer (SOL) of the ASDEX Upgrade (AUG) and DIII-D tokamaks with ion $B$ x $∇B$ drift directed toward the X-point (favorable configuration). These results are observed across multiple diagnostics and without the use of impurity seeding to reach detachment. In AUG, outer divertor leg detachment correlates with a decrease in electron density near the separatrix at the inner midplane, measured with HFS reflectometry. A concurrent reduction in inner divertor density and neutral pressure at the inner target is observed using divertor Thomson scattering and neutral pressure gauges. These effects are present in both L- and H-mode plasmas. In DIII-D, a similar reduction is detected through analysis of line-integrated hydrogenic emission measured by multiple diagnostics in the HFS SOL close to the separatrix. The consistent trends in both devices indicate that high electron density and strong hydrogenic emissivity in the HFS SOL are common features of H-mode plasmas in the favorable configuration, independent of wall material and divertor geometry. In L-mode plasmas, the reduction in electron density and neutral pressure is not observed in DIII-D, possibly due to differences in wall material. These results emphasize the importance of the divertor state in determining the two-dimensional neutral distribution and edge fueling.

detachment↗

Non-contact measurement of partial gas pressure and distribution of elemental composition using energy-resolved neutron imaging

Neutron resonance absorption imaging is a non-destructive technique that can characterize the elemental composition of a sample by measuring nuclear resonances in the spectrum of a transmitted beam. Recent developments in pixelated time-of-flight imaging detectors coupled with pulsed neutron sources pose new opportunities for energy-resolved imaging. In this paper we demonstrate non-contact measurements of the partial pressure of xenon and krypton gases encapsulated in a steel pipe while simultaneously passing the neutron beam through high-Z materials. The configuration was chosen as a proof of principle demonstration of the potential to make non-destructive measurement of gas composition in nuclear fuel rods. The pressure measured from neutron transmission spectra (~739 ± 98 kPa and ~751 ± 154 kPa for two Xe resonances) is in relatively good agreement with the pressure value of ~758 ± 21 kPa measured by a pressure gauge. This type of imaging has been performed previously for solids with a spatial resolution of ~ 100 μm. In the present study it is demonstrated that the high penetration capability of epithermal neutrons enables quantitative mapping of gases encapsulate within high-Z materials such as steel, tungsten, urania and others. This technique may be beneficial for the non-destructive testing of bulk composition of objects (such as spent nuclear fuel assemblies and others) containing various elements opaque to other more conventional imaging techniques. As a result, the ability to image the gaseous substances concealed within solid materials also allows non-destructive leak testing of various containers and ultimately measurement of gas partial pressures with sub-mm spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crush Test Abuse Stand

The purpose of this system is to simulate an internal short on battery cells by causing deformation (a crushing force) in a cell without penetration. This is performed by activating a hydraulic cylinder on one side of a blast wall with a hydraulic pump located on the other. The operator can control the rate of the crush by monitoring a local pressure gauge connected to the hydraulic cylinder or a load cell digital display located at the hydraulic pump control area. The internal short simulated would be considered a worst-case scenario of a manufacturer fs defect. This is a catastrophic failure of a cell and could be a very destructive event. Fully charged cells are to have an internal short simulated at the center of the length of the cell (away from terminals). The crush can be performed with a .- to 1-in. (.0.6- to 2.5-cm) rod placed crossways to the cell axis, causing deformation of the cell without penetration. The OCV (open-circuit voltage) and temperature of the cells, as well as the pressure and crushing force, are recorded during the operation. Occurrence of an internal short accompanied by any visible physical changes such as venting, fires, or explosions is reported. Typical analytical data examined after the test would be plots of voltage, temperature, and pressure or force versus time. The rate of crushing force can be increased or decreased based on how fast the operator pumps the hydraulic pump. The size of cylinder used to compress the battery cell can be easily changed by adding larger or smaller fittings onto the end of the hydraulic cylinder based on the battery/cell size being tested. The cell is crushed remotely and videotaped, allowing the operator to closely monitor the situation from a safe distance.

Collins, Jacob↗

Development of Methods for In-line Monitoring of Yield Stress During the Transfer of Radioactive Waste - 20435

Radioactive waste slurries at the Savannah River Site (SRS) and Hanford often behave as non-Newtonian fluids with a yield stress. The yield stress increases the size of equipment needed to transport or mix these slurries and can increase the risk of process upsets. This property is often measured by collection of samples and transportation to a laboratory, which can increase the risk of personnel exposure and even change the rheology. In addition, slurry rheology has been observed to change with time. Real-time in-line monitoring (RTIM) of rheological properties of slurries can have substantial benefits to critical processes which are currently in operation or will be part of future plans in Department of Energy (DOE) complex processes. The need for an appropriate RTIM technology that can potentially minimize or eliminate numerous sampling operations was recently identified. This research at Florida International University focuses on addressing the need for a reliable RTIM technology at US Department of Energy sites. The objective of this work is to investigate and develop appropriate and reliable technologies that can perform accurate and easy measurements of yield stress with minimal changes to the flow conditions at US Department of Energy sites. Use of ultrasound in longitudinal and shear modes was considered as a method for monitoring of yield stress variations with no disturbance to the flow. Measurement of shear wave velocity (in shear mode) and monitoring of sound velocity variations with start of flow from rest (longitudinal mode) are the underlying principles. Measurement of pressure loss and liquid rise (due to static differential pressure) during flow of slurries were two other methods that were considered and investigated. In addition, analysis of stability depth of a penetrometer in slurry medium (penetrometer method) revealed a potential suitability. This paper presents efforts associated with investigation of different methods mentioned earlier for kaolin-water mixtures at different concentrations. Theoretical analysis showed that all methods under investigation were capable of monitoring yield stress in a desirable range of 0 to 70 pascal. A bench scale test setup was constructed for investigation of pressure loss and liquid rise methods. Simulants at different concentrations were created for initial testing campaigns. For ultrasonic testing, effects of yield stress on sound propagation speed in longitudinal and shear modes were investigated for simulants placed inside PVC pipes. Parameters such as simulant concentration and pipe diameter were varied to find optimal values. It was found that spacing (or medium thickness) of 1/8 inch or less was necessary to observe echoes with sufficient strength. In addition, a significant effect of yield stress on sound propagation velocity was observed. For the liquid rise method, kaolin-water simulant at 1.17 specific gravity was pumped through a 1/4 inch pipe and liquid height was measured in a vertical riser branching off a three-way connection. Static gauge pressure was varied within [0.3 to 1.1] psi range by increase of pumping pressure and flow. Results showed consistent yield stress data within 10% deviation from values reported by a rheometer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗