Dynamic pressure measurements utilizing a cold-cathode ionization gauge
Cold cathode ionization gages dynamic pressure response as function of gas pulse mean speed and gas type, using magnetron test measurements
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Cold cathode ionization gages dynamic pressure response as function of gas pulse mean speed and gas type, using magnetron test measurements
Technique for mounting strain gages inside bolt or cylinder simultaneously inserts gage, attached dowel segment, and length of expandable tubing. Expandable tubing holds gage in place while adhesive cures, assuring even distribution of pressure on gage and area gaged.
To determine shuttle orbiter wing loads during ascent, wing load instrumentation was added to Columbia (OV-102). This instrumentation included strain gages and pressure orifices on the wing. The loads derived from wing pressure measurements taken during STS 61-C did not agree with those derived from strain gage measurements or with the loads predicted from the aerodynamic database. Anomalies in the surface immediately surrounding the pressure orifices in the thermal protection system (TPS) tiles were one possible cause of errors in the loads derived from wing pressure measurements. These surface anomalies were caused by a ceramic filler material which was installed around the pressure tubing. The filler material allowed slight movement of the TPS tile and pressure tube as the airframe flexed and bent under aerodynamic loads during ascent and descent. Postflight inspection revealed that this filler material had protruded from or receeded beneath the surface, causing the orifice to lose its flushness. Flight tests were conducted at NASA Ames Research Center Dryden Flight Research Facility to determine the effects of any anomaly in surface flushness of the orifice installation on the measured pressures at Mach numbers between 0.6 and 1.4. An F-104 aircraft with a flight test fixture mounted beneath the fuselage was used for these flights. Surface flushness anomalies typical of those on the orbiter after flight (STA 61-C) were tested. Also, cases with excessive protrusion and recession of the filler material were tested. This report shows that the anomalies in STS 61-C orifice installations adversely affected the pressure measurements. But the magnitude of the affect was not great enough to account for the discrepancies with the strain gage measurements and the aerodynamic predictions.
Single and multiple strain-gage systems were respectively evaluated as in situ point and areal sensors for monitoring sand-height variations in coastal environments. Static loading tests indicate that gage response pressure is linear for sand heights up to 24 inches. Response pressures are a function of both sand height and aggregate density, with density being influenced by both sediment texture and degree of compaction. Poorer sediment sorting and greater compaction result in higher response pressures. Field tests in a beach foreshore environment indicate that the gage systems are effective qualitative instruments for monitoring long-period migration trends of beach sediments; whereas, short-period responses are not sufficiently reliable. The durability and compactness of the gage systems must be substantially increased for effective field operations. It is recommended that the systems' qualitative potentials be further developed, whereas their development as quantitative instruments be terminated. Further development should emphasize the construction of remote recording systems designed for semipermanent installation.
High-enthalpy, arc-heated flows used for aerothermal testing present a challenging environment for flow characterization. This paper describes the design and use of cooled dwell probes used for heat-transfer and pressure characterization of the NASA and United States Department of Defense (DoD) arc facilities located at Moffett Field, CA, and Arnold Air Force Base, TN. Dwell calorimeters designed, fabricated, and tested by Thermal Technologies, Inc. (TTI) in the NASA IHF and the USAF H1 and H2 arc test facilities provide heat flux and pressure data with excellent repeatability. These calorimeters use standard Gardon calorimeter gages and pressure ports with unique cooling systems enabling them to withstand the severe arc-heated environments for durations sufficient for acquisition of steady-state data. The TTI probes have proven very robust in the extreme aerothermal environments of these facilities. This paper provides an overview of calorimeter instruments typically used in arc facilities, discusses design features of the TTI dwell probes, presents selected data acquired by the TTI calorimeters, and provides comparisons with data acquired from using measurement techniques.
Flow characteristics of NASA's 16-Inch Shock Tunnel are determined for purposes of providing hypersonic propulsion simulation capability. The key tunnel operating parameters are the incident shock speed and reservoir pressure and enthalpy. Flow characteristics of concern are the nozzle exit pressure, temperature, Mach number, Reynolds number, chemical composition, and flow uniformity. Surface mounted gages (for pressure and heat transfer) and nonintrusive optical flow diagnostics (emission and absorption spectroscopy and holographic interferometry) are used to verify tunnel conditions. Experimental measurements are used to validate computational analysis for predicting facility performance, and CFD is used to interpret the free stream optical diagnostic measurements.
Underwater sand height gage, which measures heights up to 12 inches, is comprised of two standard flush-diaphragm pressure transducers. Gage is very sensitive to buried water heights and is useful as a research tool in study of wet earth and landslide phenomena.
McLeod gage is used as the primary reference standard in a system used for absolute calibration of vacuum gages in the very low pressure range. The system involves steady-state flow of a gas through a cascade of differentially pumped chambers or stages connected by precisely defined orifices.
Computer storage requirements can be reduced if areas of commonality exist in two or more programs placed in the same computer and identical code can be used by more than one program. The pressure-volume-temperature (P-V-T) relationship for the propellant tank pressurant agent is utilized as the basis for either a primary of a backup propellant gaging program for the auxiliary power unit (APU), the reaction control system (RCS), and the orbital maneuvering system (OMS). These three propellant gaging programs were investigated. It was revealed that a very limited degree of software commonality exits among them. An examination of this common software indicated that only the computation of the helium compressibility factor in an external function subprogram accessible to both the RCS and OMS propellant gaging programs appears to offer a savings in computer storage requirements.
Novel experimental techniques are developed to measure the rapid changes in specimen dimensions during dynamic triaxial experiments. A capacitance gage is designed and constructed to measure the diameter change of the specimen inside the pressure chamber at both low and high rates. The length change is determined by a linear variable differential transformer at low rates and by Kolsky bar signals at high rates. The Kolsky bar also measures the dynamic axial stress in the specimen during the high-rate phase of an experiment. A line pressure gage records the hydrostatic pressure in the chamber. The dynamic pressure variation in the chamber during axial impact loading is detected by a manganin gage placed inside the chamber. The feasibility of this new experimental setup is demonstrated by dynamic triaxial experiments on a fine dry sand.
Following the start of SSME certification testing for the Pratt and Whitney Alternate Turbopump Development (ATD) High Pressure Oxidizer Turbopump (HPOTP), cracking of the leading edge of the inner HEX vane was experienced. The HEX vane, at the inlet of the oxidizer bowl in the Hot Gas Manifold (HGM), accepts the HPOTP turbine discharge flow and turns it toward the Gaseous Oxidizer Heat Exchanger (GOX HEX) coil. The cracking consistently initiated over a specific circumferential region of the hex vane, with other circumferential locations appearing with increased run time. Since cracking had not to date been seen with the baseline HPOTP, a fluid-structural interaction involving the ATD HPOTP turbine exit flowfield and the HEX inner vane was suspected. As part of NASA contract NAS8-36801, Pratt and Whitney conducted air flow tests of the ATD HPOTP turbine turnaround duct flowpath in the MSFC Phase 2 HGM air flow model. These tests included HEX vane strain gages and additional fluctuating pressure gages in the turnaround duct and HEX vane flowpath area. Three-dimensional flow probe measurements at two stations downstream of the turbine simulator exit plane were also made. Modifications to the HPOTP turbine simulator investigated the effects on turbine exit flow profile and velocity components, with the objective of reproducing flow conditions calculated for the actual ATD HPOTP hardware. Testing was done at the MSFC SSME Dynamic Fluid Air Flow (Dual-Leg) Facility, at air supply pressures between 50 and 250 psia. Combinations of turbine exit Mach number and pressure level were run to investigate the effect of flow regime. Information presented includes: (1) Descriptions of turbine simulator modifications to produce the desired flow environment; (2) Types and locations for instrumentation added to the flow model for improved diagnostic capability; (3) Evaluation of the effect of changes to the turbine simulator flowpath on the turbine exit flow environment; and (4) Comparison of the experimental turbine exit flow environment to the environment calculated for the ATD HPOTP.
The Mach number system for the Langley Research Center's National Transonic Facility was designed to measure pressures to determine Mach number to within + or - 0.002. Nine calibration laboratory type fused quartz gages, four different range gages for the total pressure measurement, and five different range gages for the static pressure measurement were used to satisfy the accuracy requirement over the 103,000-890,000 Pa total pressure range of the tunnel. The system which has been in operation for over 1 year is controlled by a programmable data process controller to select, through the operation of solenoid valves, the proper range fused quartz gage to maximize the measurement accuracy. The pressure gage's analog outputs are digitized by the process controller and transmitted to the main computer for Mach number computation. An automatic two-point on-line calibration of the nine quartz gages is provided using a high accuracy mercury manometer.
Horizontal single belt casting (HSBC) has great potential to replace current conventional continuous casting (CCC) processes for sheet metal production, by directly casting 3 to 1 mm sheet for the automobile industry. In the present paper, two-dimensional mathematical models were developed to study transport phenomena, for the case of an inclined wall feeding system for a liquid aluminum wrought alloy (AA6111). Based on the commercial software ANSYS FLUENT 14.5 and user-defined functions, a two-layer turbulence model was used to examine the fluid flow emanating from a slot nozzle set above a water-cooled, high-speed, steel belt. The Volume of Fluid (VOF) method was used to predict the shape of the melt-air interface. A transformed coordinate system (x′, y′) was established in order to analyze the fluid flow on the inclined wall of the feeding system. The total pressure gauge gradient (∂p{sub total}/∂x) was used to describe the behavior of the melt film inside the slot nozzle of the head box. The modeling results show that during the melt film falling process, the total gauge pressure varies within the slot nozzle, which can decrease the stability of the falling film. The first impingement between the falling film and the inclined refractory wall of the feeding system gives rise to a local oscillation, and this influences the stability of the melt film moving downwards. At the rear meniscus position between the inclined wall and the moving belt, there is a clear vibration of the air-melt interface, together with a recirculation zone. The weak vibration of the air-melt interface could be induced by the periodic variation of the melt-air interface. Moreover, the formation of tiny air pockets is predicted. Finally, on the inclined wall of the feeding system, a suitable length of the transition area is needed to avoid over-acceleration of the melt film due to the force of gravity.
A probe has been designed, constructed, and successfully used to inject methane into the DIII-D lower divertor in a manner imitating natural release by chemical erosion. This porous plug injector (PPI) probe consists of a self-contained gas reservoir with an integrated pressure gauge and a 3 cm diameter porous surface through which gas is injected into the lower divertor of the tokamak. The probe is positioned flush with the divertor target surface by means of the divertor materials evaluation system. Two gas delivery systems were developed: in the first, gas flow is regulated by a remotely controlled microvalve and in the second by a fixed micro-orifice flow restrictor. Because of the large area of the porous surface through which gas is admitted, the injected hydrocarbon molecules see a local carbon surface (>90% carbon) similar to that seen by hydrocarbons being emitted by chemical sputtering from surrounding carbon tiles. The distributed gas source also reduces the disturbance to the local plasma while providing sufficient signal for spectroscopic detection. In situ spectroscopic measurements with the PPI in DIII-D allow the direct calibration of response for measured plasma conditions from a known influx of gas.
In the dual damascene microelectronics integration scheme during the last stage of plasma etching of dielectrics down to underlying Cu layers, Cu is sputtered onto the reactor walls and is believed to cause a drift in etching rates. For photoresist etching in an O{sub 2}-containing plasma, a drop in etching rate suggests that Cu could cause a decrease in the O-atom concentration in the plasma, due perhaps to an increase in the O recombination rate on the chamber walls. We therefore studied the effects of traces of Cu on O recombination on an oxygen plasma-conditioned surface, using the spinning wall technique. With this method, a cylindrical substrate, here coated in situ with sputter-deposited Si and then oxidized in an O{sub 2} plasma, is rotated past skimmers, allowing the surface to be periodically exposed to the plasma and an Auger electron spectrometer with a pressure gauge in a differentially pumped chamber. Between plasma exposures, the sample could also be dosed with Cu from an evaporation source in a differentially pumped chamber. With no Cu on the surface, a pressure rise was observed in the Auger chamber, due to desorption of recombined O{sub 2}. These measurements were used to derive a Langmuir-Hinshelwood recombination coefficient of gamma{sub O}=0.043 for the steady-state oxidized Si, Cu-free surface. The surface was then coated with a small fraction of a monolayer (roughly approx0.002 monolayers of Cu with a dose of approx1.4x10{sup 13} cm{sup -2} and an assumed sticking coefficient of 0.3) and gamma{sub O} was found to increase to 0.069. Further dosing with Cu did not produce any further increases in gamma{sub O}. The initial low gamma{sub O} value could not be recovered by coating the surface with sputter Si, apparently due to rapid outdiffusion of Cu through Si at room temperature. Cu catalyzed recombination of O is ascribed to a redox cycling between Cu{sup +} and Cu{sup 2+} oxidation states.
Ion pumps are common vacuum pumps on DC high voltage photoguns and baked-accelerator beamlines. Commercial ion pump power supplies provide a measure of the electrical current drawn by the pump, but typically have resolution to only {approx}0.1 uA, which corresponds to pressure {approx}10{sup -9} Torr, a value considerably higher than the minimum pressure required by photoguns and nearby beamline. This submission describes a very sensitive in-house-built ion pump power supply with current monitoring capability good to less than 1 nA, and corresponding pressure in the low-minus;10{sup -11} Torr range. Besides providing 'free' pressure monitoring on a scale equivalent to the best available commercial pressure gauges, the ion pump power supply also serves as a sensitive diagnostic for detecting field emission from the photogun cathode electrode and bad electron beam orbits that could diminish photogun operating lifetime. Since its inception, this ion pump power supply has become an invaluable tool for operating the CEBAF polarized electron source. It is also a very useful low-cost diagnostic for ultrahigh vacuum studies in the laboratory.
A portable synchrotron molecular beam epitaxy (MBE) system is designed and applied for in situ investigations. The growth chamber is equipped with all the standard MBE components such as effusion cells with shutters, main shutter, cooling shroud, manipulator, reflection high energy electron diffraction setup, and pressure gauges. The characteristic feature of the system is the beryllium windows which are used for in situ x-ray measurements. An UHV sample transfer case allows in vacuo transfer of samples prepared elsewhere. We describe the system design and demonstrate its performance by investigating the annealing process of buried InGaAs self-organized quantum dots.
Helicons are efficient plasma sources, capable of producing plasma densities of 10{sup 19} m{sup -3} with only 100 s W of input rf power. There are often steep density gradients in both the neutral density and plasma density, resulting in a fully ionized core a few cm wide surrounded by a weakly ionized plasma. The ionization profile is usually not well known because the neutral density is typically inferred from indirect spectroscopic measurements or from edge pressure gauge measurements. We have developed a two photon absorption laser induced fluorescence (TALIF) diagnostic capable of directly measuring the neutral density profile. We use TALIF in conjunction with a Langmuir probe to measure the ionization fraction profile as a function of driving frequency, magnetic field, and input power. It is found that when the frequency of the driving wave is greater than a critical frequency, f{sub c} Almost-Equal-To 3f{sub lh}, where f{sub lh} is the lower hybrid frequency at the antenna, the ionization fraction is small (0.1%) and the plasma density low (10{sup 17} m{sup -3}). As the axial magnetic field is increased, or, equivalently, the driving frequency decreased, a transition is observed. The plasma density increases by a factor of 10 or more, the plasma density profile becomes strongly peaked, the neutral density profile becomes strongly hollow, and the ionization fraction in the core approaches 100%. Neutral depletion in the core can be caused by a number of mechanisms. We find that in these experiments the depletion is due primarily to plasma pressure and neutral pumping.