Physics potential of the IceCube Upgrade for atmospheric neutrino oscillations

The IceCube Upgrade is an extension of the existing IceCube Neutrino Observatory and will be deployed in the 2025–2026 austral summer. It will significantly improve the sensitivity of the detector to atmospheric neutrino oscillations. The existing 86-string IceCube array contains a dense in-fill known as DeepCore which is optimized to measure neutrinos with energies down to a few GeV. The IceCube Upgrade will consist of seven new densely instrumented strings placed within the DeepCore volume to further enhance the performance in the GeV energy range. The additional strings will feature new optical modules, each containing multiple photomultiplier tubes (PMTs), in contrast to the existing modules that each contain a single PMT. This will more than triple the number of PMT channels with respect to the current IceCube configuration, allowing for improved detection efficiency and reconstruction performance at GeV energies. We describe necessary updates to simulation, event selection, and reconstruction to accommodate the higher data rates observed by the upgraded detector and the addition of multi-PMT modules. We determine the expected sensitivity of the IceCube Upgrade to the atmospheric neutrino oscillation parameters sin 2 ⁡𝜃 23 and Δ⁢𝑚$^{2}_{32}$, the appearance of tau neutrinos and the neutrino mass ordering. The IceCube Upgrade will provide neutrino oscillation measurements that are of similar precision to those from accelerator experiments, while providing complementarity by probing higher energies and longer baselines, and with different sources of systematic uncertainties.

artificial neural networks↗

Performance studies of Hamamatsu R9800 photomultiplier tube with a new active base designed for use in the Hall D Broadband tagger Hodoscope

This paper presents the results of a study of a high rate photomultiplier and active base assembly designed for use in scintillator counters of the Hall D Jefferson Lab Broadband fixed-array Tagging Hodoscope. In its standard configuration the fixed-array hodoscope consists of 218 plastic scintillator counters made with Hamamatsu R9800 one inch in diameter photomultiplier tube. All tubes are equipped with designed at JLab new active base. The base comprised of a high voltage divider integrated with amplifiers powered by current flowing through the divider (U.S. Patent No. 6,791,269). This original design allows limiting the PMT anode current to 15-20 uA at a 4 MHz count rate, and allows tube operation at lower high voltage bias voltage while retaining a desired overall gain and dynamic range of output signals. The performance of the PMT assemblies were studied at Jeffeson Lab using a picosecond laser (PLP-10). Subsequently, two hundred fifty PMT and base assemblies were manufactured and tested. The results of testing the R9800 photomultiplier in a new active base are presented and discussed.

Popov, Vladimir↗

Simulating Scintillator Light Collection Using Measured Optical Reflectance

To accurately predict the light collection from a scintillating crystal through Monte Carlo simulations, it is crucial to know the angular distribution from the surface reflectance. Current Monte Carlo codes allow the user to set the optical reflectance to a linear combination of backscatter spike, specular spike, specular lobe, and Lambertian reflections. However, not all light distributions can be expressed in this way. In addition, the user seldom has the detailed knowledge about the surfaces that is required for accurate modeling. We have previously measured the angular distributions within BGO crystals and now incorporate these data as look-up-tables (LUTs) into modified Geant4 and GATE Monte Carlo codes. The modified codes allow the user to specify the surface treatment (ground, etched, or polished), the attached reflector (Lumirror(R), Teflon(R), ESR film, Tyvek(R), or TiO paint), and the bonding type (air-coupled or glued). Each LUT consists of measured angular distributions with 4o by 5o resolution in theta and phi, respectively, for incidence angles from 0? to 90? degrees, in 1o-steps. We compared the new codes to the original codes by running simulations with a 3 x 10 x 30 mm3 BGO crystal coupled to a PMT. The simulations were then compared to measurements. Light output was measured by counting the photons detected by the PMT with the 3 x 10, 3 x 30, or 10 x 30 mm2 side coupled to the PMT, respectively. Our new code shows better agreement with the measured data than the current Geant4 code. The new code can also simulate reflector materials that are not pure specular or Lambertian reflectors, as was previously required. Our code is also more user friendly, as no detailed knowledge about the surfaces or light distributions is required from the user.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanical properties of photomultiplier tube glasses for neutrino detection

Photomultiplier tubes (PMT) are one of the primary components of water Cherenkov neutrino detection for the Long Baseline Neutrino Experiment (LBNE). Thousands of 10- to 12-inch diameter PMT bulbs are placed in the inner wall of a detection tank or a reservoir (e.g., deep mine) filled with 10,000 gallons of high purity water with a resistivity of 11–18.24 MΩ-cm. Long-term service of PMTs is vital to the success of neutrino detection projects. We report our results of our investigation on mechanical properties of PMT glasses from two vendors and the effect of ion exchange on their mechanical strength. Vickers indentation, four-point bend test, and ring-on-ring biaxial flexural strength test were used for evaluation of the mechanical strength. Chemical (potassium–sodium ion exchange) strengthening results show increased strength of 46% in one vendor glass and a 57% increase in the other, with no significant reduction in optical transmission in the ultraviolet-visible range of the electromagnetic spectrum that is critical to neutrino detection. Finally, our results also show narrowing of the distribution of strength calculated using Weibull statistics with chemical strengthening for comparable exchange depths of 22–28 μm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TH-C-19A-10: Systematic Evaluation of Photodetectors Performances for Plastic Scintillation Dosimetry

Purpose: To assess and compare the performance of different photodetectors likely to be used in a plastic scintillation detector (PSD). Methods: The PSD consists of a 1 mm diameter, 10 mm long plastic scintillation fiber (BCF-60) which is optically coupled to a clear 10 m long optical fiber of the same diameter. A light-tight plastic sheath covers both fibers and the scintillator end is sealed. The clear fiber end is connected to one of the following six studied photodetectors: two polychromatic cameras (one with an optical lens and one with a fiber optic taper replacing the lens); a monochromatic camera with the same optical lens; a PIN photodiode; an avalanche photodiode (APD); and a photomultiplier tube (PMT). Each PSD is exposed to both low energy beams (120, 180, and 220 kVp) from an orthovoltage unit, and high energy beams (6 MV and 23 MV) from a linear accelerator. Various dose rates are explored to identify the photodetectors operating ranges and accuracy. Results: For all photodetectors, the relative uncertainty remains under 5 % for dose rates over 3 mGy/s. The taper camera collects four times more signal than the optical lens camera, although its standard deviation is higher since it could not be cooled. The PIN, APD and PMT have higher sensitivity, suitable for low dose rate and out-of-field dose monitoring. PMT's relative uncertainty remains under 1 % at the lowest dose rate achievable (50 μGy/s), suggesting optimal use for live dosimetry. Conclusion: A set of 6 photodetectors have been studied over a broad dose rate range at various energies. For dose rate above 3 mGy/s, the PIN diode is the most effective photodetector in term of performance/cost ratio. For lower dose rate, such as those seen in interventional radiology, PMTs are the optimal choice. FQRNT Doctoral Research Scholarship.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance characterization of high quantum efficiency metal package photomultiplier tubes for time-of-flight and high-resolution PET applications

Purpose: Metal package photomultiplier tubes (PMTs) with a metal channel dynode structure have several advanced features for devising such time-of-flight (TOF) and high spatial resolution positron emission tomography (PET) detectors, thanks to their high packing density, large effective area ratio, fast time response, and position encoding capability. Here, we report on an investigation of new metal package PMTs with high quantum efficiency (QE) for high-resolution PET and TOF PET detector modules. Methods: The latest metal package PMT, the Hamamatsu R11265 series, is served with two kinds of photocathodes that have higher quantum efficiency than normal bialkali (typical QE ≈ 25%), super bialkali (SBA; QE ≈ 35%), and ultra bialkali (UBA; QE ≈ 43%). In this study, the authors evaluated the performance of the new PMTs with SBA and UBA photocathodes as a PET detector by coupling various crystal arrays. They also investigated the performance improvements of high QE, focusing in particular on a block detector coupled with a lutetium-based scintillator. A single 4 × 4 × 10 mm{sup 3} LYSO, a 7 × 7 array of 3 × 3 × 20 mm{sup 3} LGSO, a 9 × 9 array of 1.2 × 1.2 × 10 mm{sup 3} LYSO, and a 6 × 6 array of 1.5 × 1.5 × 7 mm{sup 3} LuYAP were used for evaluation. All coincidence data were acquired with a DRS4 based fast digitizer. Results: This new PMT shows promising crystal positioning accuracy, energy and time discrimination performance for TOF, and high-resolution PET applications. The authors also found that a metal channel PMT with SBA was enough for both TOF and high-resolution application, although UBA gave a minor improvement to time resolution. However, significant performance improvement was observed in relative low light output crystals (LuYAP) coupled with UBA. Conclusions: The results of this study will be of value as a useful reference to select PMTs for high-performance PET detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light output measurements and computational models of microcolumnar CsI scintillators for x-ray imaging

Purpose: The authors report on measurements of light output and spatial resolution of microcolumnar CsI:Tl scintillator detectors for x-ray imaging. In addition, the authors discuss the results of simulations aimed at analyzing the results of synchrotron and sealed-source exposures with respect to the contributions of light transport to the total light output. Methods: The authors measured light output from a 490-μm CsI:Tl scintillator screen using two setups. First, the authors used a photomultiplier tube (PMT) to measure the response of the scintillator to sealed-source exposures. Second, the authors performed imaging experiments with a 27-keV monoenergetic synchrotron beam and a slit to calculate the total signal generated in terms of optical photons per keV. The results of both methods are compared to simulations obtained with hybridMANTIS, a coupled x-ray, electron, and optical photon Monte Carlo transport package. The authors report line response (LR) and light output for a range of linear absorption coefficients and describe a model that fits at the same time the light output and the blur measurements. Comparing the experimental results with the simulations, the authors obtained an estimate of the absorption coefficient for the model that provides good agreement with the experimentally measured LR. Finally, the authors report light output simulation results and their dependence on scintillator thickness and reflectivity of the backing surface. Results: The slit images from the synchrotron were analyzed to obtain a total light output of 48 keV{sup −1} while measurements using the fast PMT instrument setup and sealed-sources reported a light output of 28 keV{sup −1}. The authors attribute the difference in light output estimates between the two methods to the difference in time constants between the camera and PMT measurements. Simulation structures were designed to match the light output measured with the camera while providing good agreement with the measured LR resulting in a bulk absorption coefficient of 5 × 10{sup −5} μm{sup −1}. Conclusions: The combination of experimental measurements for microcolumnar CsI:Tl scintillators using sealed-sources and synchrotron exposures with results obtained via simulation suggests that the time course of the emission might play a role in experimental estimates. The procedure yielded an experimentally derived linear absorption coefficient for microcolumnar Cs:Tl of 5 × 10{sup −5} μm{sup −1}. To the author’s knowledge, this is the first time this parameter has been validated against experimental observations. The measurements also offer insight into the relative role of optical transport on the effective optical yield of the scintillator with microcolumnar structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic evaluation of photodetector performance for plastic scintillation dosimetry

Purpose: The authors’ objective was to systematically assess the performance of seven photodetectors used in plastic scintillation dosimetry. The authors also propose some guidelines for selecting an appropriate detector for a specific application. Methods: The plastic scintillation detector (PSD) consisted of a 1-mm diameter, 10-mm long plastic scintillation fiber (BCF-60), which was optically coupled to a clear 10-m long optical fiber of the same diameter. A light-tight plastic sheath covered both fibers and the scintillator end was sealed. The clear fiber end was connected to one of the following photodetectors: two polychromatic cameras (one with an optical lens and one with a fiber optic taper replacing the lens), a monochromatic camera with an optical lens, a PIN photodiode, an avalanche photodiode (APD), or a photomultiplier tube (PMT). A commercially available W1 PSD was also included in the study, but it relied on its own fiber and scintillator. Each PSD was exposed to both low-energy beams (120, 180, and 220 kVp) from an orthovoltage unit and high-energy beams (6 and 23 MV) from a linear accelerator. Various dose rates were tested to identify the operating range and accuracy of each photodetector. Results: For all photodetectors, the relative uncertainty was less than 5% for dose rates higher than 3 mGy/s. The cameras allowed multiple probes to be used simultaneously, but they are less sensitive to low-light signals. The PIN, APD, and PMT had higher sensitivity, making them more suitable for low dose rate and out-of-field dose monitoring. The relative uncertainty of the PMT was less than 1% at the lowest dose rate achieved (0.10 mGy/s), suggesting that it was optimal for use in live dosimetry. Conclusions: For dose rates higher than 3 mGy/s, the PIN diode is the most effective photodetector in terms of performance/cost ratio. For lower dose rates, such as those seen in interventional radiology or high-gradient radiotherapy, PMTs are the optimal choice.

60 APPLIED LIFE SCIENCES↗

Compressive sensing for nuclear security

Special nuclear material (SNM) detection has applications in nuclear material control, treaty verification, and national security. The neutron and gamma-ray radiation signature of SNMs can be indirectly observed in scintillator materials, which fluoresce when exposed to this radiation. A photomultiplier tube (PMT) coupled to the scintillator material is often used to convert this weak fluorescence to an electrical output signal. The fluorescence produced by a neutron interaction event differs from that of a gamma-ray interaction event, leading to a slightly different pulse in the PMT output signal. The ability to distinguish between these pulse types, i.e., pulse shape discrimination (PSD), has enabled applications such as neutron spectroscopy, neutron scatter cameras, and dual-mode neutron/gamma-ray imagers. In this research, we explore the use of compressive sensing to guide the development of novel mixed-signal hardware for PMT output signal acquisition. Effectively, we explore smart digitizers that extract sufficient information for PSD while requiring a considerably lower sample rate than conventional digitizers. Given that we determine the feasibility of realizing these designs in custom low-power analog integrated circuits, this research enables the incorporation of SNM detection into wireless sensor networks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Model-Based Approach to Scintillator/Photomultiplier System Characterization

Scintillator/photomultiplier systems are prevalent in many instruments to measure a variety on nuclear events. When gamma energy from a nuclear event irradiates the scintillator, event radiation interacts with the scintillator material generating photons which are detected by the photomultiplier tube (PMT). The PMT photoelectrons or photocathode current is amplified in the PMT by a number of dynode stages producing a total charge out for a given radiation flux into scintillator. The resulting current is converted to a voltage when passed through a typical load impedance. This voltage is attenuated and provided as input to a digitizer through a variety of signal conditioners (filters, amplifiers, receivers) before analog-to-digital conversion. In this report, we concentrate on the development of analytic models for the scintillator/photomultiplier system and develop both a (1) statistical simulator; and (2) a model-based signal processor to extract the desired signal information while rejecting the noise and uncertainty. We develop the model analytically, transform it to the model-based framework (state-space), and then use actual experimental data to fit the model and apply it to our processing problem.

42 ENGINEERING↗

Assembly and characterization of fast neutron detectors for TREAT fuel motion monitoring system

The TREAT fuel motion monitoring system (FMMS) currently uses a fast neutron hodoscope which allows for fast neutron imaging produced by fission in the reactor core. These neutrons are then passed unmoderated through a core slot and collimated to the 360 detector array, or hodoscope. The purpose of this project was to assemble, characterize, and qualify another 96 PMT’s to add to the current batch of 96. The assembly consists of four main components starting with a PMT, a voltage divider, a PRS button that will scintillate when struck by neutrons, and a Phenolic shroud which will house all the components to create a standard form factor. The characterization will be completed in the lab to reach the goal of having all PMT’s characterized with a determination of operability before finalized and placed inside the TREAT hodoscope.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Beam Loss Assessment Through Use of Photomultiplier Tubes

The first machine in the Fermilab Accelerator chain, the Linac, delivers a 400 MeV proton beam. The first portion of the Fermilab Linac, the Drift Tube Linac, lacks the degree of instrumentation necessary for beam tuning. To compensate for this, photomultiplier tube (PMT s) based loss monitors were installed on either side of the first two drift tube tanks, but are not yet operational. One of the main goals in this is to make PMT's operational beam loss monitors for tuning. Noise reduction and peak finding on the PMT data is a requirement for this. A method for noise reduction and peak finding has been developed and implemented to produce a consistent and stable output. Future work includes integration with ACNET to automate input and output of data for analysis of beam loss.

Waggoner, Alexander↗

Performance and Stability Characterization of the ICARUS Light Detection System

The ICARUS detector, a key component of the Short Baseline Neutrino (SBN) Program at Fermilab, consists of two identical T300 modules filled with liquid argon. It is equipped with a Light Detection System (LDS) based on 360 8-inch Hamamatsu R5912-MOD photomultiplier tubes (PMTs) arranged behind the wire planes to collect Vacuum Ultraviolet (VUV, $\sim$ 128 nm) scintillation light. Operating under cryogenic conditions ( $\sim$ 87 K), the LDS is essential for determining the event start time (t0) with nanosecond precision for beam spill synchronization, improving longitudinal spatial resolution, and contributing to the event trigger and cosmic-ray mitigation. The performance of the LDS was investigated addressing both hardware and data analysis aspects. Following a progressive degradation in PMT gain observed during operations at FNAL, systematic gain measurements were first carried out from room temperature down to low temperatures. The results show stable performance at room temperature but a significant, irreversible reduction in gain at low temperatures. Based on these findings, a series of mitigation strategies were implemented in the ICARUS detector to preserve PMT performance and ensure reliable cryogenic operation. Currently, ongoing waveform analysis of the PMT signals is being performed to characterize signal shape, charge integration, and timing properties, aiming to refine and improve the agreement between experimental data and Monte Carlo simulations.

Saia, Clara [U. Catania (main); INAF, Catania; Cat↗

Data Compression in the NEXT-100 Data Acquisition System

NEXT collaboration detectors are based on energy measured by an array of photomultipliers (PMT) and topological event filtering based on an array of silicon photomultipliers (SiPMs). The readout of the PMT sensors for low-frequency noise effects and detector safety issues requires a grounded cathode connection that makes the readout AC-couple with variations in the signal baseline. Strict detector requirements of energy resolution better than 1% FWHM require a precise baseline reconstruction that is performed offline for data analysis and detector performance characterization. Baseline variations make it inefficient to apply traditional lossy data compression techniques, such as zero-suppression, that help to minimize data throughput and, therefore, the dead time of the system. However, for the readout of the SiPM sensors with less demanding requirements in terms of accuracy, a traditional zero-suppression is currently applied with a configuration that allows for a compression ratio of around 71%. The third stage in the NEXT detectors program, the NEXT-100 detector, is a 100 kg detector that instruments approximately five times more PMT sensors and twice the number of SiPM sensors than its predecessor, the NEXT-White detector, putting more pressure in the DAQ throughput, expected to be over 900 MB/s with the current configuration, which will worsen the dead time of the acquisition data system. This paper describes the data compression techniques applied to the sensor data in the NEXT-100 detector, which reduces data throughput and minimizes dead time while maintaining the event rate to the level of its predecessor, around 50 Hz.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Volcanic eruptions and the increases in the stratospheric aerosol content: Lidar measurements from 1982 to 1986

The results of the observation for stratospheric aerosols which were carried out since the autumn of 1982 by using the NIES large lidar are described. Specifications of the lidar system are shown. The lidar has two wavelenghts of 1.06 and 0.53 micrometers. The 0.53 micrometer is mainly used for the stratospheric aerosols, because the PMT for 0.53 micrometers has higher sensitivity that that for 1.06 micrometers and the total efficiency is higher in the former. A switching circuit is used to control the PMT gain for avoiding signal induced noise in PMT. For the last four years, the stratospheric aerosol layer which was significantly perturbed by the El Chichon volcanic eruption was observed. The scattering ratio profiles observed from 1982 through 1983 are given.

Hayashida, S.↗

Gated photomultiplier response characterization for DIAL measurements

The characteristics of various detector responses are studied to understand the cause of various systematic biases and to minimize these undesirable effects in measurements of transient signals with large dynamic range. Signal-induced bias, gain variation, and the linearity of commonly used gated photomultipliers in the current integrating mode are quantitatively evaluated. Analysis of the results indicates that impurity ions inside the photomultiplier tubes (PMT) are the source of the signal induced bias and gain variation. Two different PMTs used in this study show significant differences in the magnitude and decay behavior of signal-induced bias. It was found that it can be minimized by using an external amplifier to reduce PMT gain, and by applying a low potential between the cathode and first dynode. The linearity of a PMT is also studied over a large dynamic range of input intensities employing a new technique which does not require an absolute calibration. The result of this study shows that the photomultiplier response is linear only for a limited input intensity range below a certain anode current.

Lee, H. Sang↗

Correction for nonlinear photon counting effects in lidar systems

Photomultiplier tubes (PMT's) employed in the photon counting (PC) mode of operation are widely used as detectors in lidar systems. In our laboratory, we have developed a versatile Nd:YAG lidar which is used for measurement of both the middle atmosphere and the troposphere. With this system, we encounter a very wide range of signal levels ranging from the extremely weak signals from the top of the mesosphere to the very strong returns from low level clouds. Although the system is capable of operating the PMT's in either the analog detection or photon counting mode, we find that often when we use photon counting we have portions of our lidar return which contain very useful information but are not within the linear operating regime of the PC system. We report the results of our efforts to explore the extent to which such high intensity PC signals can be quantitatively analyzed. In particular, a useful model relating the mean 'true' count rate and the observed count rate is presented and it's application to our system demonstrated. This model takes into account the variation in height of the PMT output pulses and the effect of the pulse height discrimination threshold.

Donovan, D. P.↗

Observations of "Hystereris" in Backscattered Ultraviolet Ozone Data

The backscattered ultraviolet (BUV) technique has been used for almost 3 decades to monitor global total ozone and the distribution of ozone in the stratosphere. Satellite BUV measurements in the 250-340 mn wavelength region are technically challenging because the Earth's radiance varies by approximately 4 orders of magnitude during a single scan. Further, the observed signal increases by over three orders of magnitude in about 2 minutes as the satellite emerges into daylight. The gain of the instrument's photomultiplier tube (PMT) detector is low when the spacecraft first emerges into the sunlit portion of the orbit relative to the gain observed after the PMT has experienced moderately high current levels. This "hysteresis" effect was first observed on the Nimbus-7 SBUV and TOMS instruments. The effect is difficult to characterize prelaunch because of the high signal levels and rapid variations required. We have recently observed and quantified the hysteresis effect for the NOAA-9 SBUV/2 instrument, which collected ozone data from February 1985 to February 1998. The instrument gain is observed to be up to 3% low at high solar zenith angles [Chi = 85-90 degrees] in the emergent hemisphere (i.e. Southern Hemisphere at launch). The gain error decreases as the SZA decreases and average PMT current increases, and is generally negligible for Chi < 65 degrees. The magnitude of the hysteresis effect varies with season, and exhibits long-term changes as the NOAA-9 sun-synchronous orbit drifts. In the latter portion of the record, when the spacecraft emerged from the dark in the Northern Hemisphere, hysteresis effects were then observed in the North. NOAA-9 total ozone errors due to the hysteresis effect are typically on the order of 2%, but can reach 5% in extreme cases. We have developed a quantitative correction for the hysteresis effect that incorporates both seasonal and long-term variations in magnitude. Results of similar analyses for the NOAA-11 and NOAA-14 SBUV/2 instruments will also be discussed. The characterization of the hysteresis effect in high solar zenith angle SBUV/2 ozone data represents a significant step towards reconciling polar ozone measurements from different satellite instruments.

DeLand, Matthew T.↗