Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLUTONIUM 240”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

CHARACTERIZATION OF MODIFIED MONOSODIUM TITANATE - AN IMPROVED SORBENT FOR STRONTIUM AND ACTINIDE SEPARATIONS

High-level nuclear waste produced from fuel reprocessing operations at the Savannah River Site (SRS) requires pretreatment to remove {sup 134,137}Cs, {sup 90}Sr, and alpha-emitting radionuclides (i.e., actinides) prior to disposal onsite as low level waste. An inorganic sorbent, monosodium titanate (MST), is currently used to remove {sup 90}Sr and alpha-emitting radionuclides, while a caustic-side solvent extraction process is used for removing {sup 134,137}Cs. A new peroxotitanate material, modified MST, or mMST, has recently been developed and has shown increased removal kinetics and capacity for {sup 90}Sr and alpha-emitting radionuclides compared to the current baseline material, MST. This paper describes recent results focused on further characterization of this material.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Establishing rapid analysis of Pu isotopes in seawater to study the impact of Fukushima nuclear accident in the Northwest Pacific

In order to evaluate the impact of the Fukushima derived Pu isotopes on seawater, a new analytical method to rapidly determine Pu isotopes in seawater by SF-ICP-MS including Fe(OH)2 primary co-precipitation, CaF 2 /LaF 3 secondary co-precipitation and TEVA+UTEVA+DGA extraction chromatographic separation was established. High concentration efficiency (~100%) and high U decontamination factor (~10 7 ) were achieved. The plutonium chemical recoveries were 74–88% with the mean of 83 ± 5%. The precisions for both 240 Pu/ 239 Pu atom ratios and 239+240 Pu activity concentrations were less than 5% when 15 L of seawater samples with the typical 239+240 Pu activity of the Northwest Pacific were measured. It just needs 12 hours to determine plutonium using this new method. The limit of detection (LOD) for 239 Pu and 240 Pu were both 0.08 fg/mL, corresponding to 0.01 mBq/m 3 for 239 Pu and 0.05 mBq/m 3 for 240 Pu when a 15 L volume of seawater was measured. This method was applied to determine the seawater samples collected 446–1316 km off the FDNPP accident site in the Northwest Pacific in July of 2013. The obtained 239+240 Pu activity concentrations of 1.21–2.19 mBq/m 3 and the 240 Pu/ 239 Pu atom ratios of 0.198–0.322 implied that there was no significant Pu contamination from the accident to the Northwest Pacific.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Estimation of Plutonium-240 Mass in Waste Tanks Using Ultra-Sensitive Detection of Radioactive Xenon Isotopes from Spontaneous Fission

This report details efforts to develop a technique which is able to detect and quantify the mass of 240 Pu in waste storage tanks and other enclosed spaces. If the isotopic ratios of the plutonium contained in the enclosed space is also known, then this technique is capable of estimating the total mass of the plutonium without physical sample retrieval and radiochemical analysis of hazardous material. Results utilizing this technique are reported for a Hanford Site waste tank (TX-118) and a well-characterized plutonium sample in a laboratory environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Passive assay of plutonium metal plates using a fast-neutron multiplicity counter

Here, we developed a fast-neutron multiplicity counter based on organic scintillators (EJ-309 liquid and stilbene). The system detects correlated photon and neutron multiplets emitted by fission reactions, within a gate time of tens of nanoseconds. The system was used at Idaho National Laboratory to assay a variety of plutonium metal plates. A coincidence counting strategy was used to quantify the 240 Pu effective mass of the samples. Coincident neutrons, detected within a 40-ns coincidence window, show a monotonic trend, increasing with the 240 Pu-effective mass (in this work, we tested the 0.005–0.5 kg range). After calibration, the system estimated the 240 Pu effective mass of an unknown sample ( 240 Pu eff >50 g) with an uncertainty lower than 1% in a 4-min assay time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Review Report for the Model 9977 Safety Analysis Report for Packaging Addendum 1 Justification for DNDO Contents

The Model 9977 Package is currently certified for Content Envelope C.1, {sup 238}Pu Heat Sources, either in Radioisotope Thermoelectric Generator (RTG), or in Food-Pack Can configurations, under Certificate of Compliance (CoC) Certificate Number 9977 and Package Identification Number USA/9977/B(M)F-96 (DOE). Addendum 1, Justification for DNDO Contents,--the Submittal--supplements Revision 2 of the Safety Analysis Report for Packaging for the Model 9977 Package. The Submittal adds five new contents to the Model 9977 Package, Content Envelopes, AC.1 through AC.5. The Content Envelopes are neptunium metal, the beryllium-reflected plutonium ball (BeRP Ball), plutonium/uranium metal, plutonium/uranium metal with enhanced wt% {sup 240}Pu (to 50 wt%), and uranium metal. The last three Content Envelopes are stabilized to DOE-STD-3013. These Content Envelopes will be shipped to the Device Assembly Facility (DAF) at the Nevada Test Site (NTS), where they will reside, and, hence, to off-site locations in support of the Department of Homeland Security (DHS) Domestic Nuclear Detection Office (DNDO). The new certificate will apply to a limited number of Model 9977 Packages. At the same time, the Submittal requests an extension of the periodic maintenance requirements from one (1) year to up to five (5) years using Radio-Frequency Identification (RFID) temperature-monitoring systems to measure the ambient storage temperature in order to ensure that the temperature of the Viton{reg_sign} O-rings for the 6-inch Containment Vessel (6CV) remain less than 200 F. The RFIDs have been developed by Argonne National Laboratory. An on-going surveillance program at the K-Area Materials Storage (KAMS) facility at the Savannah River Site, and an on-going examination of Viton{reg_sign} O-rings from mock Primary Containment Vessels (PCVs) at Savannah River National Laboratory (SRNL) provide the technical justification for the extension of the periodic maintenance interval. Where extended periodic maintenance is desired, the decay heat rate for the Model 9977 Package is limited to 15 watts.

99 GENERAL AND MISCELLANEOUS↗

ZPR-6 assembly 7 high {sup 240}Pu core experiments : a fast reactor core with mixed (Pu,U)-oxide fuel and a centeral high{sup 240}Pu zone.

ZPR-6 Assembly 7 (ZPR-6/7) encompasses a series of experiments performed at the ZPR-6 facility at Argonne National Laboratory in 1970 and 1971 as part of the Demonstration Reactor Benchmark Program (Reference 1). Assembly 7 simulated a large sodium-cooled LMFBR with mixed oxide fuel, depleted uranium radial and axial blankets, and a core H/D near unity. ZPR-6/7 was designed to test fast reactor physics data and methods, so configurations in the Assembly 7 program were as simple as possible in terms of geometry and composition. ZPR-6/7 had a very uniform core assembled from small plates of depleted uranium, sodium, iron oxide, U{sub 3}O{sub 8} and Pu-U-Mo alloy loaded into stainless steel drawers. The steel drawers were placed in square stainless steel tubes in the two halves of a split table machine. ZPR-6/7 had a simple, symmetric core unit cell whose neutronic characteristics were dominated by plutonium and {sup 238}U. The core was surrounded by thick radial and axial regions of depleted uranium to simulate radial and axial blankets and to isolate the core from the surrounding room. The ZPR-6/7 program encompassed 139 separate core loadings which include the initial approach to critical and all subsequent core loading changes required to perform specific experiments and measurements. In this context a loading refers to a particular configuration of fueled drawers, radial blanket drawers and experimental equipment (if present) in the matrix of steel tubes. Two principal core configurations were established. The uniform core (Loadings 1-84) had a relatively uniform core composition. The high {sup 240}Pu core (Loadings 85-139) was a variant on the uniform core. The plutonium in the Pu-U-Mo fuel plates in the uniform core contains 11% {sup 240}Pu. In the high {sup 240}Pu core, all Pu-U-Mo plates in the inner core region (central 61 matrix locations per half of the split table machine) were replaced by Pu-U-Mo plates containing 27% {sup 240}Pu in the plutonium component to construct a central core zone with a composition closer to that in an LMFBR core with high burnup. The high {sup 240}Pu configuration was constructed for two reasons. First, the composition of the high {sup 240}Pu zone more closely matched the composition of LMFBR cores anticipated in design work in 1970. Second, comparison of measurements in the ZPR-6/7 uniform core with corresponding measurements in the high {sup 240}Pu zone provided an assessment of some of the effects of long-term {sup 240}Pu buildup in LMFBR cores. The uniform core version of ZPR-6/7 is evaluated in ZPR-LMFR-EXP-001. This document only addresses measurements in the high {sup 240}Pu core version of ZPR-6/7. Many types of measurements were performed as part of the ZPR-6/7 program. Measurements of criticality, sodium void worth, control rod worth and reaction rate distributions in the high {sup 240}Pu core configuration are evaluated here. For each category of measurements, the uncertainties are evaluated, and benchmark model data are provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Spent fuel temperature and age determination from the analysis of uranium and plutonium isotopics

The capability to determine the age (time since irradiation) of spent fuel can be useful for verification and safeguards. While the age of spent fuel can be determined based on measurements of short-lived fission products, these measurements are not routinely done nor generally reported. As an alternative, age can also be determined if the uranium (U) and plutonium (Pu) isotopic values are available. Uranium isotopics are not strongly affected by fuel temperature, and bumup is determined from the {sup 235}U and {sup 236}U isotopic values. Age is calculated after estimating the {sup 241}Pu at the end of irradiation while accounting for the fuel temperature, which is determined from {sup 239}Pu or {sup 240}Pu. Burnup and age determinations are calibrated to reactor models that provide uranium and plutonium isotopics over the range of fuel irradiation. The reactor model must contain sufficient fidelity on details of the reactor type, fuel burnup, irradiation history, initial fuel enrichment and fuel temperature to obtain accurate isotopic calculations. If the latter four are unknown, they can be derived from the uranium and plutonium isotopics. Fuel temperature has a significant affect on the production of plutonium isotopics; therefore, one group cross section reactor models, such as ORIGEN, cannot be used for these calculations. Multi-group cross section set codes, such as Oak Ridge National Laboratory's TRITON code, must be used.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Distribution of neptunium and plutonium in New Mexico lichen samples ( Usnea arizonica ) contaminated by atmospheric fallout

In this study, the concentrations of 237 Np, 239 Pu and 240 Pu were determined in lichen samples ( Usnea arizonica ) that were collected from ten locations in New Mexico between 2011 and 2013 using isotope dilution inductively-coupled plasma mass spectrometry (ID-ICP-MS). The observed isotopic ratios for 237 Np/ 239 Pu and 240 Pu/ 239 Pu indicate trace contamination from global and regional fallout (e.g. Trinity test and atmospheric testing at the Nevada Test Site). The fact that actinide contamination is detected in recent lichen collections suggests continuous re-suspension of fallout radionuclides even 50 years after ratification of the Limited Test Ban Treaty.

54 ENVIRONMENTAL SCIENCES↗

Total Measurement Uncertainty in Neutron Coincidence Multiplicity Analysis

Neutron multiplicity counting is the most commonly used nondestructive assay technique for determining the plutonium mass within containers of scrap PuO 2 or mixed oxide (MOX). In multiplicity analysis, the 240 Pu eff mass, leakage multiplication, and alpha ratio (the ratio of [α, n]-to-spontaneous fission neutron production) are the three primary unknown sample properties. They must be determined simultaneously. To solve for these three unknowns in a multiplicity assay, three measured values are needed: the singles, doubles, and triples neutron count rates. While the analysis is limited to solving for three unknowns, there are many additional factors that impact the observed count rates and contribute to the measurement uncertainty. In this study we investigate the various uncertainty contributors for the multiplicity analysis through a combination of traditional uncertainty propagation techniques supplemented by Monte Carlo simulations to address the dependences not explicitly expressed by the point source model. Uncertainties arising from counting statistics, calibration parameters, calibration method, nuclear data, and various material characteristics (isotopic abundances, chemical form, density, and impurities) are considered. A Total Measurement Uncertainty (TMU) estimate is then developed from these uncertainty contributors. This study is confined to multiplicity analysis of items commonly encountered in international safeguards applications. That is, the study focused on Pu oxides and MOX materials for the masses ranging up to 4000 grams total Pu. Multiplicity measurements were simulated using MCNP V6 based on the Plutonium Scrap Multiplicity Counter (PSMC), Epithermal Multiplicity Counter (ENMC), Pyrochemical Multiplicity Counter, and Large Epithermal Multiplicity Counter (LEMC) for this study; however, this report focuses on the parameterization of the uncertainties for the PSMC. The performance differences between the PSMC and the other multiplicity counting systems are relatively small, primarily manifesting in the impact on measurement precision so that the evaluation developed for the PSMC can be applied to the other multiplicity counting systems. Finally an analysis tool, the Multiplicity TMU Estimator, was developed from this study to serve as an aid for evaluation of the total measurement uncertainty of multiplicity assay results obtained from the commonly used INCC acquisition and analysis software.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Atalante research facility new mass limits in a unit containing plutonium and minor actinides - 14402

ATALANTE, located in Marcoule, is one of the main Nuclear Facilities of the French Alternative Energies and Atomic Energy Commission (CEA). This facility is mainly dedicated to research and development for nuclear energy related to the back end of the fuel cycle: spent fuel and final waste management. It is a large research complex housing chemistry and analytical laboratories and shielded cells (240 glove boxes and 11 shielded cells), equipped for basic studies through to demonstration experiments. Within the facility, one unit can contain plutonium and curium at the same time. In this case, nuclear criticality safety is achieved by exercising control over mass. A subcritical mass limit is defined for plutonium (280 g for {sup 239}Pu) and an exemption mass limit (3 g for {sup 245}Cm) is used for the actinide. In order to increase the maximum mass (in particular {sup 245}Cm) which can be handled in the unit, new mass control limits were studied, based on control over the sum of the mass ratio to the upper subcritical mass, noted m{sub lim}, for each nuclide (350 g for {sup 239}Pu; 34.8 g or 23 g for {sup 245}Cm) as shown in equation (1) below. m({sup 239}Pu)/ m{sub lim}({sup 239}Pu)+ m({sup 245}Cm)/m{sub lim}({sup 245}Cm)≤1 (1) To validate this criticality safety control method, a study was conducted to demonstrate that, for different masses of {sup 239}Pu and {sup 245}Cm meeting equation (1), the calculated effective multiplication factor is always lower than the effective multiplication factor corresponding to a sphere of 350 g of pure {sup 239}Pu, moderated, with 20 cm water reflection. The two pseudo fissile media are: - metallic plutonium (100% {sup 239}Pu, density 19.86), moderated with water, - metallic curium (100% {sup 245}Cm, density 13.566), moderated with water. The calculation model is a sphere of {sup 245}Cm metal positioned in a sphere of {sup 239}Pu metal, with optimum moderation for each fissile material, and a full water reflection (20 cm). The results show that, under certain conditions, the effective multiplication factor of the mixture can be higher than the effective multiplication factor of each pure fissile material when using the upper subcritical mass of 34.8 g for {sup 245}Cm. When using 23 g of {sup 245}Cm, the k{sub eff} of the mixture is always lower than the k{sub eff} of pure {sup 239}Pu. These calculations enable the safety documentation to be changed by introducing a new process operational procedure, based on equation (1). This change in procedure allows the operator to work with a larger quantity of curium in the unit. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of the 240 Pu/ 239 Pu mass ratio using a transition-edge-sensor microcalorimeter for total decay energy spectroscopy

In this study, we have developed a new category of sensor for measurement of the 240 Pu/ 239 Pu mass ratio from aqueous solution samples with advantages over existing methods. Aqueous solution plutonium samples were evaporated and encapsulated inside of a gold foil absorber, and a superconducting transition-edge-sensor microcalorimeter detector was used to measure the total reaction energy (Q-value) of nuclear decays via heat generated when the energy is thermalized. Since all of the decay energy is contained in the absorber, we measure a single spectral peak for each isotope, resulting in a simple spectral analysis problem with minimal peak overlap. We found that mechanical kneading of the absorber dramatically improves spectral quality by reducing the size of radioactive inclusions within the absorber to scales below 50 nm such that decay products primarily interact with atoms of the host material. Due to the low noise performance of the microcalorimeter detector, energy resolution values of 1 keV fwhm (full width at half-maximum) at 5.5 MeV have been achieved, an order of magnitude improvement over α-spectroscopy with conventional silicon detectors. We measured the 240 Pu/ 239 Pu mass ratio of two samples and confirmed the results by comparison to mass spectrometry values. These results have implications for future measurements of trace samples of nuclear material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plutonium Isotopes in the Terrestrial Environment at the Savannah River Site, USA. A Long-Term Study

This work presents the findings of a long term plutonium study at Savannah River Site (SRS) conducted between 2003 and 2013. Terrestrial environmental samples were obtained at Savannah River National Laboratory (SRNL) in A-area. Plutonium content and isotopic abundances were measured over this time period by alpha spectrometry and three stage thermal ionization mass spectrometry (3STIMS). Here we detail the complete sample collection, radiochemical separation, and measurement procedure specifically targeted to trace plutonium in bulk environmental samples. Total plutonium activities were determined to be not significantly above atmospheric global fallout. However, the 238 Pu/ 239+240 Pu activity ratios attributed to SRS are above atmospheric global fallout ranges. The 240 Pu/ 239 Pu atom ratios are reasonably consistent from year to year and are lower than fallout, while the 242 Pu/ 239 Pu atom ratios are higher than fallout values. Overall, the plutonium signatures obtained in this study reflect a mixture of weapons-grade, higher burn-up, and fallout material. This study provides a blue print for long term low level monitoring of plutonium in the environment.

54 ENVIRONMENTAL SCIENCES↗

Intercomparison of the Radio-Chronometric Ages of Plutonium-Certified Reference Materials with Distinct Isotopic Compositions

In this article, an intercomparison of the radio-chronometric ages of four distinct plutonium-certified reference materials varying in chemical form, isotopic composition, and period of production are presented. The cross-comparison of the different 234 U/ 238 Pu, 235 U/ 239 Pu, 236 U/ 240 Pu, and 241 Am/ 241 Pu model purification ages obtained at four independent analytical facilities covering a range of laboratory environments from bulk sample processing to clean facilities dedicated to nuclear forensic investigation of environmental samples enables a true assessment of the state-of-practice in “age dating capabilities” for nuclear materials. The analytical techniques evaluated used modern mass spectrometer instrumentation including thermal ionization mass spectrometers and inductively coupled plasma mass spectrometers for isotopic abundance measurements. Both multicollector and single collector instruments were utilized to generate the data presented here. Consensus values established in this study make it possible to use these isotopic standards as quality control standards for radio-chronometry applications. Results highlight the need for plutonium isotopic standards that are certified for 234 U/ 238 Pu, 235 U/ 239 Pu, 236 U/ 240 Pu, and 241 Am/ 241 Pu model purification ages as well as other multigenerational radio-chronometers such as 237 Np/ 241 Pu. Due to the capabilities of modern analytical instrumentation, analytical laboratories that focus on trace level analyses can obtain model ages with marginally larger uncertainties than laboratories that handle bulk samples. Lastly, when isotope ratio measurement techniques like thermal ionization mass spectrometry and inductively coupled plasma mass spectrometry with comparable precision are utilized, model purification ages with similar uncertainties are obtained.

36 MATERIALS SCIENCE↗

Plutonium Basket Counter Measurement Control Q3-Q4 2023

The Plutonium Basket Counter (PBC) is a spent fuel nuclear safeguards instrument that was developed to measure spent-fuel elements from MAGNOX-type research reactors and determine their plutonium content. The instrument is designed to measure fuel elements in spent fuel cooling pools through underwater operation, but it is also able to measure radiation sources in air. The PBC determines fuel plutonium content by detecting neutrons with an array of Helium-3 detectors. The electronics make use of a JSR-15 shift register for data collection and IAEA Neutron Coincidence Counting (INCC) software for data analysis. The PBC is used to determine the 240 Pu content in spent MAGNOX fuel elements grouped into basket-like bundles, thus the instrument’s name. Reactor burnup calculations can be used in conjunction with the data from the PBC to estimate the total plutonium content in the fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of the current status of cross-section evaluations of plutonium minor isotopes

Much attention have been given to nuclear data and reaction evaluations relative to the major actinides, as they constitute the main component in many nuclear applications. For this reason, the currency of evaluated files for minor actinides has not been maintained with the same level of accuracy. Motivated by future applications that will be sensitive to minor isotopes of plutonium, this report aims to review and assess the current status of the reaction evaluations in the ENDF/B library for 238;240;241;242 Pu, as well as to compile available experimental data that have not yet been incorporated into evaluated files.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SCALED ELECTRON MODEL OF A DOGBONE MUON RLA WITH MULTI-PASS ARCS

The design of a dogbone RLA with linear-field multi-pass arcs was earlier developed for accelerating muons in a Neutrino Factory and a Muon Collider. It allows for efficient use of expensive RF while the multi-pass arc design based on linear combined-function magnets exhibits a number of advantages over separate-arc or pulsed-arc designs. Such an RLA may have applications going beyond muon acceleration. This paper describes a possible straightforward test of this concept by scaling a GeV scale muon design for electrons. Scaling muon momenta by the muon-to-electron mass ratio leads to a scheme, in which a 4.5 MeV electron beam is injected at the middle of a 3 MeV/pass linac with two double-pass return arcs and is accelerated to 18 MeV in 4.5 passes. All spatial dimensions including the orbit distortion are scaled by a factor of 7.5, which arises from scaling the 200 MHz muon RF to a readily available at CEBAF 1.5 GHz. The footprint of a complete RLA fits in an area of 25 by 7 m. The scheme utilizes only fixed magnetic fields including injection and extraction. The hardware requirements are not very demanding, making it straightforward to implement. In this report, we have shown first of all that measuring the energy spectrum of the fast neutrons in the liquid scintillators allows one to distinguish the two chemical forms of plutonium. In addition, combining this information with the Feynman 2-neutron and 3-neutron correlations allows one to extract the {alpha}-ratio without explicitly knowing the multiplication. Given the {alpha}-ratio one can then extract the multiplication as well as the {sup 239}Pu and {sup 240}Pu masses directly from the moment equations.

43 PARTICLE ACCELERATORS↗

Data Testing with Zero Power Reactor (ZPR), Zero Power Physics Reactor (ZPPR), and New Thermal Epithermal eXperiments (TEX) Plutonium Benchmarks [Slides]

This presentation states that new TSLs in ENDF/B-VIII.0 will reduce the overprediction of the library for the most moderated cases. The differences between VII.1 and VIII.0 are driven by the 239 Pu changes and are consistently higher for all configurations. The VIII.0 239 Pu thermal cross sections were specifically adjusted lower to better predict plutonium thermal solutions criticality benchmarks, yet they overpredict the TEX thermal configurations, moderated by PE. Other, smaller differences have been seen for 240 Pu and 56 Fe. PMM-002 has shown utility in testing cross sections over a wide range of neutron energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prompt Neutron Decay for Delayed Critical Bare and Natural-Uranium-Reflected Metal Spheres of Plutonium and Highly Enriched Uranium

Prompt neutron decay at delayed criticality was measured by Oak Ridge National Laboratory for uranium-reflected highly enriched uranium (HEU) and Pu metal spheres (FLATTOP), for an unreflected Pu metal (4.5% {sup 240}Pu) sphere (JEZEBEL) at Los Alamos National Laboratory (LANL) and for an unreflected HEU metal sphere at Oak Ridge Critical Experiments Facility. The average prompt neutron decay constants from hundreds of Rossi-{alpha} and randomly pulsed neutron measurements with {sup 252}Cf at delayed criticality are as follows: 3.8458 {+-} 0.0016 x 10{sup 5} s{sup -1}, 2.2139 {+-} 0.0022 x 10{sup 5} s{sup -1}, 6.3126 {+-} 0.0100 x 10{sup 5} s{sup -1}, and 1.1061 {+-} 0.0009 x 10{sup 6} s{sup -1}, respectively. These values agree with previous measurements by LANL for FLATTOP, JEZEBEL, and GODIVA I as follows: 3.82 {+-} 0.02 x 10{sup 5} s{sup -1} for a uranium core; 2.14 {+-} 0.05 x 10{sup 5} s{sup -1} and 2.29 x 10{sup 5} s{sup -1} (uncertainty not reported) for a plutonium core; 6.4 {+-} 0.1 x 10{sup 5} s{sup -1}, and 1.1 {+-} 0.1 x 10{sup 6} s{sup -1}, respectively, but have smaller uncertainties because of the larger number of measurements. For the FLATTOP and JEZEBEL assemblies, the measurements agree with calculations. Traditionally, the calculated decay constants for the bare uranium metal sphere GODIVA I and the Oak Ridge Uranium Metal Sphere were higher than experimental by {approx}10%. Other energy-dependent quantities for the bare uranium sphere agree within 1%.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗