Adsorption of cadmium ions on a platinum electrode
Electrochemical degradation of platinum electrode in cadmium air battery by cadmium ion adsorption
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Electrochemical degradation of platinum electrode in cadmium air battery by cadmium ion adsorption
Calibration of commercial platinum resistance thermometer using Z function interpolation
Platinum-thorium oxide alloy for resistojet thruster showing increase in stress rupture life
Determination of adhesion properties of platinum and gold in contact with tungsten and iridium using field ion microscopy techniques
Hydrogen and carbon monoxide coadsorption on platinum single crystal surface, examining interactions and species formation by thermal flash and electron impact techniques in ultrahigh vacuum
Platinum resistance thermometers calibration normalized in resistance-difference ratios
The optical constants of platinum and gold thin films have been determined in the spectral region of 40 to 200 nm by reflection measurements. The highly polarized continuum of synchrotron radiation emitted by the 240-MeV electron storage ring at the Physical Sciences Laboratory of the University of Wisconsin was used as a light source for the spectrum below 120 nm, while a windowless discharge lamp coupled to a normal incidence monochromator provided a source for the longer wavelengths. Optical constants were determined by a computer program based on iterative solutions to the Fresnel equations for reflection as a function of the angle of incidence.
Results of five years experience in calibrating about 1000 commercial platinum resistance thermometers (PRT) are reported. These PRT were relatively small and rugged, with ice-point resistances from 200 to 5000 ohms. Calibrations normalized in terms of resistance-difference ratios (Cragoe Z function) were found to be remarkably uniform for five of six different types of PRT tested, and to agree very closely with normalized calibrations of the primary reference standard type PRT. The Z function normalization cancels residual resistances which are not temperature dependent and simplifies interpolation between calibration points when the quality of a given type of PRT has been established in terms of uniform values of the Z function. Measurements at five or six well spaced base-point temperatures with Z interpolation will suffice to calibrate a PRT accurately from 4 to 900 K.
The structure of small platinum particles condensed in vacuum onto NaCl (001), NaCl (111) and mica substrates was studied by electron diffraction and electron microscopy. Results show that above a certain substrate temperature decahedral or icosahedral particles are formed. These particles are practically absent with substrates cleaved in high vacuum. They are always much less numerous than in gold films prepared under the same conditions. Assumptions made to explain this phenomenon are: (1) the initial growth of an abnormal structure of the nuclei as opposed by the substrate; (2) the particles disappear before they attain a size which corresponds to the observations; and (3) the particles result from a coalescence mechanism leading to multiple twinned particles.
A honeycomb catalyst of platinum (4.2 kg/cu m loading) over cordierite, with gamma-alumina washcoat, a cross section of 2.4 x 2.4 sq cm, a length of 7.6 cm, and a characteristic channel diameter of 1.4 mm is used as a steady flow reactor. Measurements are made with C3H8/air mixtures at 650 to 800 K inlet temperatures, 110 KPa pressure, 10 to 40 m/s inlet velocity, 0.19 to 0.32 equivalence ratios, and approximately 1.5 mole percent water content. The measured quantities are the substrate tempeature at ten axial locations, the exhaust gas temperature, the exhaust concentrations of CO, CO2, O2, and total hydrocarbons, and the pressure drop across the monolith. The measured quantities are compared with those computed with a two-dimensional steady-state model for axial and radial convection and diffusion of mass, momentum, energy and homogeneous (three overall reactions) and heterogeneous (infinitely fast) reactions. It is found that, under the tested conditions, most of the fuel is converted to CO2 and H2O at the surface. Gas-phase reactions tend rapidly to become more important as the temperature and equivalence ratio are increased and the flow velocity is decreased. Surface fuel conversion is much more rapid than fuel diffusion, resulting in diffusion-controlled oxidation.
Platinum resistance elements used in bridge circuit for measuring temperature difference between two flowing liquids. Temperature errors with circuit are less than 0.01 degrees C over range of 100 degrees C.
Thirty-one commercially designed platinum resistance thermometers were evaluated for applicability to stagnation temperature measurements between -190 C and +65 C in the Langley Research Center's National Transonic Facility. Evaluation tests included X-ray shadowgraphs, calibrations before and after aging, and time constant measurements. Two wire-wound low thermal mass probes of a conventional design were chosen as most suitable for this cryogenic wind tunnel application.
A previously unrecognized property of iron cosmic spheres is reported. The most common spheres larger than 300 microns do not, in fact, contain FeNi metal cores, but instead contain a micrometer-sized nugget composed almost entirely of platinum group elements. These elements appear to have been concentrated by the oxidation of molten meteoritic metal during atmospheric entry. This process is critically dependent on the relative abundance of oxygen in the atmosphere, and the first appearance of the nuggets in the geological record may provide a marker indicating when the oxygen abundance attained half of its present level.
The existence of iron meteor oblation spheres in deep sea sediments was known for over a century. These spheres generally were believed to be composed of either pure magnetite and wustite or an oxide shell surrounding a NiFe metal core. A large number of 300 micron to 600 micron spheres found were pure oxide spheres, usually containing a solitary 10 micron platinum group nugget (pgn) composed almost entirely of group VIII metals. Twelve PGN's were analyzed and most had chondritic abundances with some depletions that correlate with element volatility. PGN formation by oxidation of a molten metal sphere entering the atmosphere cannot occur if the oxygen abundance in the atmosphere is less than half of its present value. The first appearance of PGN's in the geological record should mark when, in the Earth's history, oxygen rose to this level.
The thermal response of two types of Platinum Resistance Thermometers (PRT's), which are being considered for use in the National Transonic Wind Tunnel Facility, were studied. Response time correlations for each PRT, in flowing water, oil and air, were established separately. A universal correlation, tau WOA = 2.0 + 1264, 9/h, for a Hy-Cal Sensor (with a reference resistance of 100 ohm) within an error of 20% was established while the universal correlation for the Rosemount Sensor (with a reference resistance of 1000 ohm), tau OA = 0.122 + 1105.6/h, was found with a maximum percentage error of 30%. The correlation for the Rosemount Sensor was based on air and oil data only which is certainly not sufficient to make a correlation applicable to every condition. Therefore, the correlation needs more data to be gathered in different fluids. Also, it is necessary to state that the calculation of the parameter, h, was based on the available heat transfer correlations, whose accuracies are already reported in literature uncertain within 20-30%. Therefore, the universal response constant correlations established here for the Hy-Cal and Rosemount sensors are consistent with the uncertainty in the input data and are recommended for future use in flowing liquids and gases.
The 'plunge method' recommended by ASTM has been used to determine the time constant of 100-ohm platinum resistance thermometers (PRT) considered for use in the National Transonic Facility. It is shown that the response time of ventilated PRT can be correlated with the reciprocal of the heat transfer coefficient in a given field. Universal correlations are established for the 100- and 1000-ohm PRT with uncertainties of 20 and 30 percent, respectively. The correlations are found to be consistent with the uncertainty involved in heat transfer correlations available in the literature and are recommended for use in flowing liquids and gases.
The light off transient of catalytic combustion of lean CO-air mixtures in a platinum coated channel of a honeycomb monolith is studied with a model that resolves transient radial and axial gradients in both the gas and the solid. For the conditions studied it is concluded that: the initial heat release occurs near the entrance at the gas-solid interface and is controlled by heterogeneous reactions; large spatial and temporal temperature gradients occur in the solid near the entrance controlled mostly by the availability of fuel; the temperature of the solid near the entrance achieves almost its steady state value before significant heating of the back; heterogeneous reactions and the gas heated up front and flowing downstream heat the back of the solid; the overall transient time is controlled by the thermal inertia of the solid and by forced convection; radiation significantly influences both transient and steady state particularly near the entrance; the oxidation of CO occurs mostly on the catalyst and becomes diffusion controlled soon into the transient.
The applicability of the self-heating technique for checking the calibration of platinum resistance thermometers located inside wind tunnels was investigated. This technique is based on a steady state measurement of resistance increase versus joule heating. This method was found to be undesirable, mainly because of the fluctuations of flow variables during any wind tunnel testing.