Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHOTONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Photonic band gap structures of obliquely incident electromagnetic wave propagation in a one-dimension absorptive plasma photonic crystal

The photonic band gap structures of obliquely incident electromagnetic waves propagating in a one-dimension plasma photonic crystal with collision have been studied on the basis of electromagnetic theory and transfer matrix approach. The dispersion relations for both the transverse electric wave case and the transverse magnetic wave case are deduced. And the photonic band gap structures, with their function dependence on the microplasma layer density, microplasma width, collision frequency, background material dielectric constant, and incident angle, are computed. The results show that there exist two photonic band gap structures in an adsorptive plasma photonic crystal: one is a normal photonic band gap structure and the other is an absorption photonic band gap structure. Parameter dependence of the effects is calculated and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of differential cross sections for inclusive isolated-photon and photon+jet production in proton-proton collisions at $\sqrt{s} = 13\,\text {TeV} $

Measurements of inclusive isolated-photon and photon+jet production in proton–proton collisions at $\sqrt{s} = 13\,\text {TeV} $ are presented. The analysis uses data collected by the CMS experiment in 2015, corresponding to an integrated luminosity of 2.26 $\,\text {fb}^{-1}$ . The cross section for inclusive isolated photon production is measured as a function of the photon transverse energy in a fiducial region. The cross section for photon+jet production is measured as a function of the photon transverse energy in the same fiducial region with identical photon requirements and with the highest transverse momentum jet. In conclusion, all measurements are in agreement with predictions from next-to-leading-order perturbative QCD.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the photon identification efficiencies with the ATLAS detector using LHC Run 2 data collected in 2015 and 2016

The efficiency of the photon identification criteria in the ATLAS detector is measured using 36.1 fb 1 to 36.7 fb 1 of pp collision data at √s = 13 TeV collected in 2015 and 2016. The efficiencies are measured separately for converted and unconverted isolated photons, in four different pseudorapidity regions, for transverse momenta between 10 GeV and 1.5 TeV. The results from the combination of three data-driven techniques are compared with the predictions from simulation after correcting the variables describing the shape of electromagnetic showers in simulation for the average differences observed relative to data. Data-to-simulation efficiency ratios are determined to account for the small residual efficiency differences. These factors are measured with uncertainties between 0.5% and 5% depending on the photon transverse momentum and pseudorapidity. The impact of the isolation criteria on the photon identification efficiency, and that of additional soft pp interactions, are also discussed. The probability of reconstructing an electron as a photon candidate is measured in data, and compared with the predictions from simulation. In conclusion, the efficiency of the reconstruction of photon conversions is measured using a sample of photon candidates from Z → μμγ events, exploiting the properties of the ratio of the energies deposited in the first and second longitudinal layers of the ATLAS electromagnetic calorimeter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Is there a low-energy enhancement in the photon strength function in molybdenum?

Recent claims of a low-energy enhancement in the photon strength function of {sup 96}Mo are investigated. Using the DANCE detector the gamma-ray spectra following resonance neutron capture was measured. The spectrum fitting method was used to indirectly extract a photon strength function from the gamma-ray spectra. No strong low energy enhancement in the photon strength function was found.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Interferometric two-photon-absorption spectroscopy with three entangled photons

In this work, we propose an interferometric pump-probe technique that employs three entangled photons generated by cascaded spontaneous parametric downconversion. A Mach–Zehnder interferometer made of two three-port waveguide arrays is inserted in the optical path. Two independent phases introduced to manipulate the entangled photon state serve as control parameters and can selectively excite matter pathways. Compared to two-photon-absorption of an entangled photon-pair, the three-photon signals are significantly enhanced by frequency-dispersed photon-counting detection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observational consistency and future predictions for a 3.5 keV ALP to photon line

Motivated by the possibility of explaining the 3.5 keV line through dark matter decaying to axion-like particles that subsequently convert to photons, we study ALP-photon conversion for sightlines passing within 50 pc of the galactic centre. Conversion depends on the galactic centre magnetic field which is highly uncertain. For fields at low or mid-range of observational estimates (10–100 μG), no observable signal is possible. For fields at the high range of observational estimates (a pervasive poloidal mG field over the central 150 pc) it is possible to generate sufficient signal to explain recent observations of a 3.5 keV line in the galactic centre. In this scenario, the galactic centre line signal comes predominantly from the region with z>20pc, reconciling the results from the Chandra and XMM-Newton X-ray telescopes. The dark matter to ALP to photon scenario also naturally predicts the non-observation of the 3.5 keV line in stacked galaxy spectra. We further explore predictions for the line flux in galaxies and suggest a set of galaxies that is optimised for observing the 3.5 keV line in this model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental search for hidden photon CDM in the eV mass range with a dish antenna

A search for hidden photon cold dark matter (HP CDM) using a new technique with a dish antenna is reported. From the result of the measurement, we found no evidence for the existence of HP CDM and set an upper limit on the photon-HP mixing parameter χ of ∼6×10{sup −12} for the hidden photon mass m{sub γ}=3.1±1.2 eV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraining ALP-photon coupling using galaxy clusters

We study photon-ALP conversion by resonance effects in the magnetized plasma of galaxy clusters and compare the predicted distortion of the cosmic microwave background spectrum in the direction of such objects to measurements of the thermal Sunyaev-Zeldovich effect. Using galaxy cluster models based on current knowledge, we obtain upper limits on the photon-ALP coupling constant g of ≲O(10{sup −11} GeV{sup −1}). The constraints apply to the mass range of 2⋅10{sup −14} eV ≲m{sub ALP}≲3⋅10{sup −12} eV in which resonant photon-ALP conversions can occur. These limits are slightly stronger than current limits, and furthermore provide an independent constraint. We find that a next generation PRISM-like experiment would allow limits down to g≈O(10{sup −14} GeV{sup −1}), two orders of magnitude stronger than the currently strongest limits in this mass range.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the inclusive isolated prompt photon cross section in pp collisions at √s=7 TeV with the ATLAS detector

A measurement of the cross section for the inclusive production of isolated prompt photons in pp collisions at a center-of-mass energy √s=7 TeV is presented. The measurement covers the pseudorapidity ranges |η γ |<1.37 and 1.52≤|η γ |<1.81 in the transverse energy range 15≤E γ T <100 GeV. The results are based on an integrated luminosity of 880 nb -1 , collected with the ATLAS detector at the Large Hadron Collider. Photon candidates are identified by combining information from the calorimeters and from the inner tracker. Residual background in the selected sample is estimated from data based on the observed distribution of the transverse isolation energy in a narrow cone around the photon candidate. The results are compared to predictions from next-to-leading-order perturbative QCD calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation of multi-photon emission isotopes using time-resolved SimSET multiple photon history generator

Abstract-Multiple-photon emitters, such as In-111 or Se-75, have enormous potential in the field of nuclear medicine imaging. For example, Se-75 can be used to investigate the bile acid malabsorption and measure the bile acid pool loss. The simulation system for emission tomography (SimSET) is a well-known Monte Carlo simulation (MCS) code in nuclear medicine for its high computational efficiency. However, current SimSET cannot simulate these isotopes due to the lack of modeling of complex decay scheme and the time-dependent decay process. To extend the versatility of SimSET for simulation of those multi-photon emission isotopes, a time-resolved multiple photon history generator based on SimSET codes is developed in present study. For developing the time-resolved SimSET (trSimSET) with radionuclide decay process, the new MCS model introduce new features, including decay time information and photon time-of-flight information, into this new code. The half-life of energy states were tabulated from the Evaluated Nuclear Structure Data File (ENSDF) database. The MCS results indicate that the overall percent difference is less than 8.5% for all simulation trials as compared to GATE. To sum up, we demonstrated that time-resolved SimSET multiple photon history generator can have comparable accuracy with GATE and keeping better computational efficiency. The new MCS code is very useful to study the multi-photon imaging of novel isotopes that needs the simulation of lifetime and the time-of-fight measurements. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Prospects for in vivo estimation of photon linear attenuation coefficients using postprocessing dual-energy CT imaging on a commercial scanner: Comparison of analytic and polyenergetic statistical reconstruction algorithms

Purpose: Accurate patient-specific photon cross-section information is needed to support more accurate model-based dose calculation for low energy photon-emitting modalities in medicine such as brachytherapy and kilovoltage x-ray imaging procedures. A postprocessing dual-energy CT (pDECT) technique for noninvasivein vivo estimation of photon linear attenuation coefficients has been experimentally implemented on a commercial CT scanner and its accuracy assessed in idealized phantom geometries. Methods: Eight test materials of known composition and density were used to compare pDECT-estimated linear attenuation coefficients to NIST reference values over an energy range from 10 keV to 1 MeV. As statistical image reconstruction (SIR) has been shown to reconstruct images with less random and systematic error than conventional filtered backprojection (FBP), the pDECT technique was implemented with both an in-house polyenergetic SIR algorithm, alternating minimization (AM), as well as a conventional FBP reconstruction algorithm. Improvement from increased spectral separation was also investigated by filtering the high-energy beam with an additional 0.5 mm of tin. The law of propagated uncertainty was employed to assess the sensitivity of the pDECT process to errors in reconstructed images. Results: Mean pDECT-estimated linear attenuation coefficients for the eight test materials agreed within 1% of NIST reference values for energies from 1 MeV down to 30 keV, with mean errors rising to between 3% and 6% at 10 keV, indicating that the method is unbiased when measurement and calibration phantom geometries are matched. Reconstruction with FBP and AM algorithms conferred similar mean pDECT accuracy. However, single-voxel pDECT estimates reconstructed on a 1 × 1 × 3 mm{sup 3} grid are shown to be highly sensitive to reconstructed image uncertainty; in some cases pDECT attenuation coefficient estimates exhibited standard deviations on the order of 20% around the mean. Reconstruction with the statistical AM algorithm led to standard deviations roughly 40% to 60% less than FBP reconstruction. Additional tin filtration of the high energy beam exhibits similar pDECT estimation accuracy as the unfiltered beam, even when scanning with only 25% of the dose. Using the law of propagated uncertainty, low Z materials are found to be more sensitive to image reconstruction errors than high Z materials. Furthermore, it is estimated that reconstructed CT image uncertainty must be limited to less than 0.25% to achieve a target linear-attenuation coefficient estimation uncertainty of 3% at 28 keV. Conclusions: That pDECT supports mean linear attenuation coefficient measurement accuracies of 1% of reference values for energies greater than 30 keV is encouraging. However, the sensitivity of the pDECT measurements to noise and systematic errors in reconstructed CT images warrants further investigation in more complex phantom geometries. The investigated statistical reconstruction algorithm, AM, reduced random measurement uncertainty relative to FBP owing to improved noise performance. These early results also support efforts to increase DE spectral separation, which can further reduce the pDECT sensitivity to measurement uncertainty.

61 RADIATION PROTECTION AND DOSIMETRY↗

Single-mode Fiber and Few-Mode Fiber Photonic Lanterns Performance Evaluated for Use in a Scalable Real-Time Photon Counting Ground Receiver

Photonic lanterns provide an efficient way of coupling light from a single large-core fiber to multiple small-core fibers. This capability is of interest for space to ground communication applications. In these applications, the optical ground receivers require high-efficiency coupling from an atmospherically distorted focus spot to multiple fiber coupled single pixel super-conducting nanowire detectors. This paper will explore the use of photonic lanterns in a real-time ground receiver that is scalable and constructed with commercial parts. The number of small-core fibers that make a photonic lantern determines the number of spatial modes that they couple. For instance, lanterns made with n number of single-mode fibers can couple n number of spatial modes. Although the laser transmitted from a spacecraft originates as a Gaussian shape, the atmosphere distorts the beam profile by scattering energy into higher-order spatial modes. Therefore, if a ground receiver is sized for a target data rate with n number of detectors, the corresponding lantern made with single-mode fibers will couple n number of spatial modes. The energy of the transmitted beam scattered into spatial modes higher than n will be lost. This paper shows this loss may be reduced by making lanterns with few-mode fibers instead of single-mode fibers, increasing the number of spatial modes that can be coupled and therefore increasing the coupling efficiency to single pixel, single photon detectors. The free space to fiber coupling efficiency of these two types of photonic lanterns are compared over a range of the free-space coupling numerical apertures and mode field diameters. Results indicate the few mode fiber lantern has higher coupling efficiency for telescopes with longer focal lengths under higher turbulent conditions. Also presented is analysis of the jitter added to the system by the lanterns, showing the few-mode fiber photonic lantern adds more jitter than the single-mode fiber lantern, but less than a multimode fiber.

photon counting↗

Two-photon absorption of soft X-ray free electron laser radiation by graphite near the carbon K-absorption edge

We have examined the transmission of soft X-ray pulses from the FERMI free electron laser through carbon films of varying thickness, quantifying nonlinear effects of pulses above and below the carbon K-edge. At typical of soft X-ray free electron laser intensities, pulses exhibit linear absorption at photon energies above and below the K-edge, ~308 and ~260 eV, respectively; whereas two-photon absorption becomes significant slightly below the K-edge, ~284.2 eV. The measured two-photon absorption cross section at 284.18 eV (~6 x 10-48 cm4 s) is 7 orders of magnitude above what is expected from a simple theory based on hydrogen-like atoms - a result of resonance effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of the synergistic effect between slow photons and electron trapping on the photocatalytic properties of TiO2 photonic crystals

Highlights: • We report the preparation of titanium dioxide photonic crystals (PCs) having two pore sizes. • Electronic band gap (BG) and photonic band gap (PBG) were determined with the use of UV–vis spectroscopy. • The position of PBG was affected by the pore size of PC. • Metallic silver (electron trapping centers) were generated on the surface of both types of PCs by a photoreduction of silver Ag{sup +} ions. • Photocatalytic properties of silver-modified TiO{sub 2} photonic crystals were enhanced by synergistic effect caused by overlapping the edges of PBG and BG combined with electron trapping by AgNPs. - Abstract: Titanium dioxide photonic crystals (PCs) were obtained using the sol-gel method and polystyrene (PS) microspheres as a template with two different diameters: 300 nm and 460 nm. The resulting materials were labeled as PC-300 and PC-460. In the following step, PCs were modified with silver nanoparticles (AgNPs) generated by the photoreduction of silver Ag{sup +} ions. The obtained PCs were denoted as AgNPs/PC-300 and AgNPs/PC-460. The size of the AgNPs were 28 nm ± 2 nm for the AgNPs/PC-300 and 21 nm ± 1 nm for AgNPs/PC-460. The characteristic features of TiO{sub 2} PCs, such as electronic band gap (BG), photonic band gap (PBG) and an occurrence of slow photon effect (SPE), were determined with the use of UV–vis spectroscopy. The photocatalytic performance of the prepared PCs was defined by monitoring the photodegradation rates of Rhodamine B (RhB) measured in the presence of PC-300, PC-460, AgNPs/PC-300, AgNPs/PC-460 and non-porous TiO{sub 2} coating (NPC) as reference material. It was found that the appropriate utilization of SPE by overlapping the edge of PBG with semiconductor BG and electron trapping by the presence of AgNPs exerted a strong synergistic effect on the photocatalytic properties of AgNPs/PCs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Monolithically integrated self-rolled-up microtube-based vertical coupler for three-dimensional photonic integration

We demonstrate a self-rolled-up microtube-based vertical photonic coupler monolithically integrated on top of a ridge waveguide to achieve three-dimensional (3D) photonic integration. The fabrication process is fully compatible with standard planar silicon processing technology. Strong light coupling between the vertical coupler and the ridge waveguide was observed experimentally, which may provide an alternative route for 3D heterogeneous photonic integration. The highest extinction ratio observed in the transmission spectrum passing through the ridge waveguide was 23 dB.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct fiber-coupled single photon source based on a photonic crystal waveguide

A single photon source plays a key role in quantum applications such as quantum computers and quantum communications. Epitaxially grown quantum dots are one of the promising platforms to implement a good single photon source. However, it is challenging to realize an efficient single photon source based on semiconductor materials due to their high refractive index. Here we demonstrate a direct fiber coupled single photon source with high collection efficiency by employing a photonic crystal (PhC) waveguide and a tapered micro-fiber. To confirm the single photon nature, the second-order correlation function g{sup (2)}(τ) is measured with a Hanbury Brown-Twiss setup. The measured g{sup (2)}(0) value is 0.15, and we can estimate 24% direct collection efficiency from a quantum dot to the fiber.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photon upconversion with hot carriers in plasmonic systems

In this paper, we propose a scheme of photon upconversion based on harnessing the energy of plasmonic hot carriers. Low-energy photons excite hot electrons and hot holes in a plasmonic nanoparticle, which are then injected into an adjacent semiconductor quantum well where they radiatively recombine to emit a photon of higher energy. We theoretically study the proposed upconversion scheme using Fermi-liquid theory and determine the internal quantum efficiency of upconversion to be as high as 25% in 5 nm silver nanocubes. This upconversion scheme is linear in its operation, does not require coherent illumination, offers spectral tunability, and is more efficient than conventional upconverters.

36 MATERIALS SCIENCE↗

On measuring stimulated photon–photon scattering using multiple ultraintense lasers

Stimulated photon–photon scattering is a predicted consequence of quantum electrodynamics that has yet to be measured directly. Measuring the cross section for stimulated photon–photon scattering is the aim of a flagship experiment for NSF OPAL, a proposed laser user facility with two, 25-PW beamlines. We present optimized experimental designs for achieving this challenging and canonical measurement. A family of experimental geometries is identified that satisfies the momentum- and energy-matching conditions for two selected laser frequency options. Numerical models predict a maximum signal exceeding 1000 scattered photons per shot at the experimental conditions envisaged at NSF OPAL. Experimental requirements on collision geometry, polarization, cotiming and copointing, background suppression, and diagnostic technologies are investigated numerically. These results confirm that a beam cotiming shorter than the pulse duration and control of the copointing on a scale smaller than the shortest laser wavelength are needed to robustly scatter photons on a per-shot basis. Finally, we assess the bounds that a successful execution of this experiment may place on the mass scale of Born–Infeld nonlinear electrodynamics beyond the standard model of physics.

Beyond the Standard Model↗