Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE ERROR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

On the combination of molecular replacement and single-wavelength anomalous diffraction phasing for automated structure determination

The combination of molecular replacement and single-wavelength anomalous diffraction improves the performance of automated structure determination with Auto-Rickshaw. A combination of molecular replacement and single-wavelength anomalous diffraction phasing has been incorporated into the automated structure-determination platform Auto-Rickshaw. The complete MRSAD procedure includes molecular replacement, model refinement, experimental phasing, phase improvement and automated model building. The improvement over the standard SAD or MR approaches is illustrated by ten test cases taken from the JCSG diffraction data-set database. Poor MR or SAD phases with phase errors larger than 70° can be improved using the described procedure and a large fraction of the model can be determined in a purely automatic manner from X-ray data extending to better than 2.6 Å resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Challenges in solving structures from radiation-damaged tomograms of protein nanocrystals assessed by simulation

Structure-determination methods are needed to resolve the atomic details that underlie protein function. X-ray crystallography has provided most of our knowledge of protein structure, but is constrained by the need for large, well ordered crystals and the loss of phase information. The rapidly developing methods of serial femtosecond crystallography, micro-electron diffraction and single-particle reconstruction circumvent the first of these limitations by enabling data collection from nanocrystals or purified proteins. However, the first two methods also suffer from the phase problem, while many proteins fall below the molecular-weight threshold required for single-particle reconstruction. Cryo-electron tomography of protein nanocrystals has the potential to overcome these obstacles of mainstream structure-determination methods. Here, a data-processing scheme is presented that combines routines from X-ray crystallography and new algorithms that have been developed to solve structures from tomograms of nanocrystals. This pipeline handles image-processing challenges specific to tomographic sampling of periodic specimens and is validated using simulated crystals. The tolerance of this workflow to the effects of radiation damage is also assessed. The simulations indicate a trade-off between a wider tilt range to facilitate merging data from multiple tomograms and a smaller tilt increment to improve phase accuracy. Since phase errors, but not merging errors, can be overcome with additional data sets, these results recommend distributing the dose over a wide angular range rather than using a finer sampling interval to solve the protein structure.

59 BASIC BIOLOGICAL SCIENCES↗

An Experiment-based Distribution Level Performance Comparison among PMUs

This paper presents a experiment-based distribution level performance comparison among three Phasor Measurement Units (PMUs). Several evaluation criteria, including the total vector error, the phase angle error, the frequency error, the rate of change of frequency, the response time, the settling time, the overshoot, and the algorithm window size, are selected to compare the static and dynamic performances of the PMUs under steady state and step response test conditions. In order to have a more realistic test environment, a test is setup in which PMUs under evaluation have exactly the same input signals. The quantitative experiment result analysis gives an end-user guideline to the PMU selection regarding distribution level applications.

Yin, He↗

High-power tests of a single-cell copper accelerating cavity driven by two input couplers.

High-power tests were conducted on a 350-MHz, single-cell copper accelerating cavity driven simultaneously by two H-loop input couplers for the purpose of determining the reliability, performance, and power-handling capability of the cavity and related components, which have routinely operated at 100-kW power levels. The test was carried out utilizing the APS 350-MHz RF Test Stand, which was modified to split the input rf power into two frac12-power feeds, each supplying power to a separate H-loop coupler on the cavity. Electromagnetic simulations of the two-coupler feed system were used to determine coupler match, peak cavity fields, and the effect of phasing errors between the coupler feed lines. The test was conducted up to a maximum total rf input power of 164-kW CW. Test apparatus details and performance data will be presented.

43 PARTICLE ACCELERATORS↗

Coriolis force compensation and laser beam delivery for 100-m baseline atom interferometry

The Coriolis force is a significant source of systematic phase errors and dephasing in atom interferometry and is often compensated by counter-rotating the interferometry laser beam against Earth's rotation. We present a novel method for performing Coriolis force compensation for long-baseline atom interferometry, which mitigates atom-beam misalignment due to beam rotation, an effect which is magnified by the long lever arm of the baseline length. The method involves adjustment of the angle of the interferometer beam prior to a magnifying telescope, enabling the beam to pivot around a tunable position along the interferometer baseline. By tuning the initial atom kinematics and adjusting the angle with which the interferometer beam pivots about this point, we can ensure that the atoms align with the center of the beam during the atom optics laser pulses. This approach will be used in the MAGIS-100 atom interferometer and could also be applied to other long-baseline atom interferometers. An additional challenge associated with long baseline interferometry is that since long-baseline atom interferometers are often located outside of typical laboratory environments, facilities constraints may require lasers to be housed in a climate-controlled room a significant distance away from the main experiment. Nonlinear effects in optical fibers restrict the use of fiber-based transport of the high-power interferometry beam from the laser room to the experiment. We present the design of and prototype data from a laser transport system for MAGIS-100 that maintains robustness against alignment drifts despite the absence of a long fiber.

Glick, Jonah↗

Accurate MTF measurement in digital radiography using noise response

Purpose: The authors describe a new technique to determine the system presampled modulation transfer function (MTF) in digital radiography using only the detector noise response. Methods: A cascaded-linear systems analysis was used to develop an exact relationship between the two-dimensional noise power spectrum (NPS) and the presampled MTF for a generalized detector system. This relationship was then utilized to determine the two-dimensional presampled MTF. For simplicity, aliasing of the correlated noise component of the NPS was assumed to be negligible. Accuracy of this method was investigated using simulated images from a simple detector model in which the ''true'' MTF was known exactly. Measurements were also performed on three detector technologies (an x-ray image intensifier, an indirect flat panel detector, and a solid state x-ray image intensifier), and the results were compared using the standard edge-response method. Flat-field and edge images were acquired and analyzed according to guidelines set forth by the International Electrotechnical Commission, using the RQA 5 spectrum. Results: The presampled MTF determined using the noise-response method for the simulated detector system was in close agreement with the true MTF with an averaged percent difference of 0.3% and a maximum difference of 1.1% observed at the Nyquist frequency (f{sub N}). The edge-response method of the simulated detector system also showed very good agreement at lower spatial frequencies (less than 0.5 f{sub N}) with an averaged percent difference of 1.6% but showed significant discrepancies at higher spatial frequencies (greater than 0.5 f{sub N}) with an averaged percent difference of 17%. Discrepancies were in part a result of noise in the edge image and phasing errors. For all three detector systems, the MTFs obtained using the two methods were found to be in good agreement at spatial frequencies less than 0.5 f{sub N} with an averaged percent difference of 3.4%. Above 0.5 f{sub N}, differences increased to an average of 20%. Deviations of the experimental results largely followed the trend seen in the simulation results, suggesting that differences between the two methods could be explained as resulting from the inherent inaccuracies of the edge-response measurement technique used in this study. Aliasing of the correlated noise component was shown to have a minimal effect on the measured MTF for the three detectors studied. Systems with significant aliasing of the correlated noise component (e.g., a-Se based detectors) would likely require a more sophisticated fitting scheme to provide accurate results. Conclusions: Results indicate that the noise-response method, a simple technique, can be used to accurately measure the MTF of digital x-ray detectors, while alleviating the problems and inaccuracies associated with use of precision test objects, such as a slit or an edge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Objected constrained registration and manifold learning: A new patient setup approach in image guided radiation therapy of thoracic cancer

Purpose: The management of thoracic malignancies with radiation therapy is complicated by continuous target motion. In this study, a real time motion analysis approach is proposed to improve the accuracy of patient setup. Methods: For 11 lung cancer patients a long training fluoroscopy was acquired before the first treatment, and multiple short testing fluoroscopies were acquired weekly at the pretreatment patient setup of image guided radiotherapy (IGRT). The data analysis consisted of three steps: first a 4D target motion model was constructed from 4DCT and projected to the training fluoroscopy through deformable registration. Then the manifold learning method was used to construct a 2D subspace based on the target motion (kinetic) and location (static) information in the training fluoroscopy. Thereafter the respiratory phase in the testing fluoroscopy was determined by finding its location in the subspace. Finally, the phase determined testing fluoroscopy was registered to the corresponding 4DCT to derive the pretreatment patient position adjustment for the IGRT. The method was tested on clinical image sets and numerical phantoms. Results: The registration successfully reconstructed the 4D motion model with over 98% volume similarity in 4DCT, and over 95% area similarity in the training fluoroscopy. The machine learning method derived the phase values in over 98% and 93% test images of the phantom and patient images, respectively, with less than 3% phase error. The setup approach achieved an average accumulated setup error less than 1.7 mm in the cranial-caudal direction and less than 1 mm in the transverse plane. All results were validated against the ground truth of manual delineations by an experienced radiation oncologist. The expected total time for the pretreatment setup analysis was less than 10 s. Conclusions: By combining the registration and machine learning, the proposed approach has the potential to improve the accuracy of pretreatment setup for patients with thoracic malignancy.

60 APPLIED LIFE SCIENCES↗

Instrumental phase-based method for Fourier transform spectrometer measurements processing

Phase correction is a critical procedure for most space-borne Fourier transform spectrometers (FTSs) whose accuracy (owing to often poor signal-to-noise ratio, SNR) can be jeopardized from many uncontrollable environmental conditions. This work considers the phase correction in an FTS working under significant temperature change during the measurement and affected by mechanical disturbances. The implemented method is based on the identification of an instrumental phase that is dependent on the interferometer temperature and on the extraction of a linear phase component through a least-squares approach. The use of an instrumental phase parameterized with the interferometer temperature eases the determination of the linear phase that can be extracted using only a narrow spectral region selected to be immune from disturbances. The procedure, in this way, is made robust against phase errors arising from instrumental effects, a key feature to reduce the disturbances through spectra averaging. The method was specifically developed for the Mars IR Mapper spectrometer, that was designed for operation onboard a rover on the Mars surface; the validation was performed using ground and in-flight measurements of the Fourier transform IR spectrometer planetary Fourier spectrometer, onboard the MarsExpress mission. The symmetrization has been exploited also for the spectra calibration, highlighting the issues deriving from the cases of relevant beamsplitter emission. The applicability of this procedure to other instruments is conditional to the presence in the spectra of at least one spectral region with a large SNR along with a negligible (or known) beamsplitter emission. For the PFS instrument, the processing of data with relevant beamsplitter emission has been performed exploiting the absorption carbon dioxide bands present in Martian spectra.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deterministic stabilization of eight-way 2D diffractive beam combining using pattern recognition

We demonstrate a new method for controlling diffractive, high-power beam combination, sensing phase errors by analyzing the intensity pattern of uncombined side beams at the output. A square array of eight beams is combined with <0.3% stability and 84.6% efficiency. As the channel count is increased, so does the usable information, enabling scaling to large channel counts without significant slowing of control loop response time, an advantage over single-input algorithms.

47 OTHER INSTRUMENTATION↗

Offset lock with a 440-GHz range using electro-optic modulation

Offset locking is crucial to many physics experiments. Wide range offset locks are desirable, as they increase the span of usable frequencies in an experiment. Here, we experimentally realize a wide-range offset lock using a beat-note setup combined with electro-optic phase modulation. By using frequency down-conversion of the beat note and locking to sidebands generated by electro-optic modulation, we achieve an offset range of ± 220.1 GHz with offset frequency fluctuations under 0.1 Hz and a phase error variance of 0.017 rad 2 over a 100 kHz bandwidth, greatly widening the range compared to past setups using this method. The relative simplicity of our setup provides a compelling method for locking at offsets in the hundreds of GHz range.

Zhou, Ocean (ORCID:0000000279192636)↗

Status of the Development of Superconducting Undulators for Storage Rings and Free Electron Lasers at the Advanced Photon Source

Development of superconducting undulator (SCU) technology continues at the Advanced Photon Source (APS). The experience of building and successful operating the first short-length, 16-mm period length superconducting undulator SCU0 paved the way for a 1-m long, 18-mm period device— SCU18-1— which has been in operation since May 2015. The APS SCU team has also built and tested a 1.5-m long, 21-mm period length undulator as a part of the LCLS SCU R&D program, aimed at demonstration of SCU technology availability for free electron lasers. This undulator successfully achieved all the requirements including a phase error of 5° RMS. Our team has recently completed one more 1-m long, 18-mm period length undulator— SCU18-2— that is replacing the SCU0. We are also working on a helical SCU for the APS. The status of these projects will be presented.

Ivanyushenkov, Y.↗

Effect of Finite Pulse Length and Laser Frequency Chirp on HGHG and EEHG Seeding

Theoretical studies of high-gain harmonic generation (HGHG) and echo-enabled harmonic generation (EEHG) often start from a simplified model in which the beam is assumed infinitely long and longitudinally uniform and the laser induced energy modulation is perfectly sinusoidal and of infinite duration. In such a model the resulting seed has a spectrum consisting of a collection of delta-functions (of zero width) located at the harmonics of the laser frequency. Being a useful tool for study of the seed bunching amplitudes, such a model cannot be used for realistic analysis the spectral properties of the seed. In this paper we take into account the finite duration of the laser pulse as well as some possible laser phase errors to study their effect on the spectrum of the seed.

99 GENERAL AND MISCELLANEOUS↗

Mathematical Formulation used by MATLAB Code to Convert FTIR Interferograms to Calibrated Spectra

This report discusses the mathematical procedures used to convert raw interferograms from Fourier transform infrared (FTIR) sensors to calibrated spectra. The work discussed in this report was completed as part of the Helios project at Los Alamos National Laboratory. MATLAB code was developed to convert the raw interferograms to calibrated spectra. The report summarizes the developed MATLAB scripts and functions, along with a description of the mathematical methods used by the code. The first step in working with raw interferograms is to convert them to uncalibrated spectra by applying an apodization function to the raw data and then by performing a Fourier transform. The developed MATLAB code also addresses phase error correction by applying the Mertz method. This report provides documentation for the MATLAB scripts.

97 MATHEMATICS AND COMPUTING↗

Longitudinal Beam Parameter Tolerances of NSLS-II

Similar to the transverse phase space, the beam parameters in the longitudinal phase space must also be monitored and controlled. In the longitudinal phase space the fundamental parameters are: bunch arrival time(or the corresponding RF phase), average momentum, bunch length, and momentum spread. These parameters are usually perturbed by the various noises in a real machine. The noises could excite longitudinal bunch motion, seen by the users as timing jitter, intensity and wavelength variation, and transverse position shift et al. The longitudinal oscillations also cause longitudinal emittance growth, therefore lengthen the bunch and increase the momentum spread, and eventually decrease the brightness. As a rule of thumb for the tolerances, either transverse or longitudinal, the perturbation caused by the noises should not result in a decrease of brightness by more than 10%. The users are concerned about the longitudinal beam parameters in several ways. First the timing jitter affects the timing-dependent experiments. Even though a photo-diode detection system is usually used to to determine the arrival time, the bandwidth is only about 1 kHz. The users from this category ask for a timing jitter tolerance to be 5% of the RMS bunch length over the frequency range from 500 Hz to 50 kHz. This corresponds to a phase error of Δφ = 1.6 mr or 0.1° for a 10 ps bunch with a 500 MHz rf system.

47 OTHER INSTRUMENTATION↗

Fourth Generation MPDV and MBR at DARHT

A new experimental setup for diagnosing hydrotest performance was designed, built, and implemented at DARHT. The setup consists of 128 points of fourth generation (Gen4) multiplexed photonic Doppler velocimetry (MPDV) and 128 separate points of modulation based ranging (MBR) to serve as a direct complement to the MPDV. The diagnostics were designed to overcome limitations in the third generation of the MPDV diagnostic that limited laser launch power to ~10 mW per point. As the main failure mechanism identified in the third generation MPDV system arose from stimulated Brillouin scattering, a nonlinear optical phenomenon inherent in standard single mode fiber, the fourth generation MPDV system reduced the number of time-multiplexed channels by a factor of two. This has allowed laser launch power to be increased to as much as 200 mW per channel which is a 20 times increase in the signal to noise ratio (SNR) as compared with the third generation system. This document will first discuss the previous limitations and describe the design of the system. This will be followed by the results of a simple flyer plate experiment used to demonstrate the improved SNR as well as calibrate the phase errors in the system that MBR is sensitive to.

42 ENGINEERING↗

Metals and Quantum Materials with Spin-orbit Interactions by Quantum Monte Carlo methods

The key goals of this project were as follows: 1) Analysis and benchmarks of electron correlation effects recovered in the fixed-node approximation that is inherent to quantum Monte Carlo (QMC) method as applied to metallic states; 2) development of new algorithms for electron spin-degrees of freedom to be treated as explicit quantum variables; 3) designing electronic structure QMC algorithm for efficient evaluation of spin-orbit effects in systems with heavy atoms; 4) adapting the algorithm to complex wave functions and developing corresponding fixed-phase approximation; 5) design and testing of algorithm for valence-only non-local spin-orbit operators; 6) analysis of fixed-node vs fixed-phase errors and their comparisons. The key accomplishments: i) We carried out a systematic study of Li systems by the fixed-node diffusion Monte Carlo method. This involved Li atom, molecule, cluster and solid calculated by the full range of QMC methods including fixed-node QMC.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Harmonic Slip-Stacking

Particle accelerators employ slip-stacking configurations to store two particle beams with disparate momenta within a single ring. Additionally, A novel slip-stacking configuration employing a harmonic RF cavity was proposed and studied. Anticipated benefits of the harmonic cavity include mitigating parametric resonances, minimizing emittance growth, and significantly expanding the stable longitudinal phase-space area. By surpassing the requirements of PIP-II operation, the harmonic RF cavity will support extending slip-stacking operation for subsequent beam power upgrades of Main Injector, including a proposed cycle rate improvement. Our ongoing research will verify the simulation of harmonic slip-stacking (HSS) operation under RF phase-errors, such as those causes by beam-loading effects.

Habibeh, Mohammad↗

Extracting cavity and pulse phases from limited data for coherent pulse stacking

Coherent pulse stacking (CPS) is a new time-domain coherent addition technique that stacks several optical pulses into a single output pulse, enabling high pulse energy and high average power. A Z-domain model targeting the pulsed laser is assembled to describe the optical interference process. In this study, an algorithm, extracting the cavity phase and pulse phases from limited data, where only the pulse intensity is available, is developed to diagnose optical cavity resonators. We also implement the algorithm on the cascaded system of multiple optical cavities, achieving phase errors less than 1.0°(root mean square), which could ensure the stability of CPS.

42 ENGINEERING↗