The impacts of membrane pinholes on PEM water electrolysis

Polymer electrolyte membrane (PEM) water electrolysis is a promising technology to efficiently produce green hydrogen. Irregularities in membrane electrode assembly (MEA) component materials caused by manufacturing, processing, handling, or operation can lead to performance loss and failure. One example is the presence of pinholes in the membrane, which can cause increased gas transport (crossover) and lead to electrical shorting. This work investigates the effects of intentionally introduced pinholes with various sizes up to 350μm in diameter. The presence of the pinholes resulted in minimal impacts on the cell voltage (±30 mV at 4Acm -2 ). However, the pinholes significantly increased H 2 crossover, which decreased hydrogen production efficiency and increased the minimum current density for safe operation. The impacts of the pinhole on the H 2 crossover and efficiency are more severe for open pinhole features than tear-like pinhole features. In conclusion, this research demonstrates that even small pinholes cannot be disregarded from a safety, efficiency, and operating strategy perspective.

08 HYDROGEN↗

Caltalyst Layer Crack Detector, or CLCD ("clicked") [SWR-20-60]

The Caltalyst Layer Crack Detector, or CLCD ("clicked") is a program that takes in optical micrographs of catalyst coatings for PEM fuel cells or electrolyzers and calculates the percent area that consist of cracks. It does so using a custom algorithm that searches for dark features larger than the background graininess of the catalyst layer.

Pfeilsticker, Jason↗

Technology Strategy Assessment: Findings from Storage Innovations 2030 Bidirectional Hydrogen Storage

Hydrogen is the most common element in the universe, comprising nearly 75% of all normal matter, and it has been used by scientists for centuries, but it was not fully recognized as an element until 1766, when it was isolated by Henry Cavendish. Early work focused on the generation of hydrogen through the oxidation of metals in water, which released hydrogen gas. Hydrogen’s lighter-than-air and flammable properties were immediately used in engines, zeppelins, and as feedstock for a wide variety of chemical reactions. Several approaches were developed for the production of hydrogen with the most common being associated with the production and conversion of hydrocarbon-based fuels. Coal gasification, steam methane reforming, and other reformation processes provide the majority of current hydrogen production due to the relatively low cost of hydrogen produced through these processes. More than 95% of hydrogen production is used for industrial processes rather than energy storage. To facilitate affordable decarbonization of these industrial processes and to advance the use of hydrogen as a fuel in transportation, DOE launched the Hydrogen Shot as part of the Energy Earthshots Initiative. The goal of the Hydrogen Shot is to reduce the cost of clean hydrogen by 80% to $1/kg of clean hydrogen production within one decade (known as the “1 1 1” goal). This is distinct from the Long-Duration Storage Shot, which is the primary focus of this report; however, it is intrinsically linked to bidirectional hydrogen storage. Several important chemical synthesis processes are dependent upon hydrogen, and the production and use of hydrogen is generally driven by its connection to one of these markets. For example, ammonia is one of the most highly produced chemicals in the world and it depends chiefly on hydrogen. Ammonia is primarily used for agricultural fertilizer and is considered to be largely responsible for a doubling of agricultural production per unit of land over the last century. Another one of hydrogen’s primary uses is as a catalyst in petroleum refining during the desulfurization process. Beyond chemical production, hydrogen is used as a reductant in the production of steel and has been demonstrated as a substitute for metallurgical coal in the production of raw iron. It is even used in the hydrogenation reaction for food products to create more shelf-stable semi-solid fats. However, while hydrogen is produced on the order of 100 million metric tons/year globally to feed these industries, more than 95% of hydrogen is produced from hydrocarbons that emit CO2 during the process. Conversely, electrolysis is a process by which electricity is used to separate hydrogen and oxygen in water molecules, usually across a membrane. Hydrogen production via electrolysis lowers the carbon intensity of produced hydrogen when coupled with low-carbon electricity. Currently, global electrolysis capacity is on the order of 1 GW, which equates to about 500 metric tons/day of hydrogen production. To support large-scale industrial decarbonization, capacity will likely need to increase by two to three orders of magnitude. Electrolysis technology is broadly separated into groups that are defined by the electrolyte used, with further subdivision based on the operating characteristics. The majority of commercial electrolyzer systems are based around three main technology groups: liquid alkaline, proton exchange membrane, and solid oxide. Liquid Alkaline (LA) electrolysis is the oldest, most mature, least expensive, and most common commercial technology, with 400 plants in operation by 1902. Its hydrogen output is low relative to the size of the system due to a low current density. LA electrolysis utilizes a liquid potassium hydroxide solution as the electrolyte. Proton exchange membrane (PEM) electrolysis (also known as polymer electrolyte membrane electrolysis), described in 1960, relies on an acid-impregnated polymer membrane as the electrolyte and typically offers three to six times higher hydrogen production per unit cell area than LA electrolysis. Solid oxide electrolysis, or high-temperature electrolysis, utilizes a ceramic cell as the electrolyte and operates on steam rather than liquid water, enabling electrical efficiencies of more than 90%, which is up from 60% with PEM. Two pre-commercial electrolyzer technologies to note are alkaline exchange membrane (AEM) and proton-conducting solid oxide electrolysis cell (SOEC). AEM potentially has the advantages of both LA and PEM technologies in that it is able to use low-cost materials like LA but with the ability to operate at higher output pressures with a smaller footprint like PEM. Proton-conducting SOEC is similar to commercial SOEC, which uses an oxide-conducting ceramic; however, it uses a proton-conducting ceramic that has the potential to operate at lower temperatures and has lower capital costs. Each of these technologies is experiencing a rapid improvement in performance and a reduction in installed cost, and each appears to be well suited to specific applications. Besides differences in the type of electrolyzer used, the main difference in the architecture of bidirectional hydrogen systems is how the hydrogen is stored. Currently, the most cost-effective way to store large amounts of hydrogen gas is underground, such as in large salt caverns that have been hollowed out. These salt caverns are geographically concentrated in small portions of the United States and are not generally near large metropolitan areas; however, other subsurface architectures are being investigated to expand this reach. A more widely deployable option is aboveground pressurized tanks. These systems are about 10 times as expensive because of the materials and safety margins required to hold hydrogen at high pressures. A third option is using materials-based storage, such as liquid organic hydrogen carriers. By reversibly attaching the produced hydrogen to other molecules, it can be stored at near atmospheric pressure and room temperature. This has the potential to reduce the material cost of storage but may result in a reduction in the efficiency of the process because there are both hydrogen uptake and release processes. While materials-based storage has not been used extensively for large-scale hydrogen storage in the past, there is currently significant activity regarding developing materials and processes for use in large-scale hydrogen storage applications. Electrolysis-produced hydrogen offers an unusual opportunity for energy storage applications. Unlike more conventional energy storage approaches, such as batteries, which operate entirely within electrical markets, hydrogen is a valuable product beyond the electric market and can be directed to the most lucrative use. Hydrogen also can be directly converted back to electricity using either a fuel cell or turbine, or it can be sold to other markets, such as chemical synthesis, steel production, or even export. In this way, excess electricity can be upgraded to the most valuable product. Finally, its use can be actively managed between multiple off-takers; for example, local hydrogen storage can provide a specific amount of stored electricity and any excess can be exported to ammonia production. This flexibility is amplified by the fact that hydrogen storage has fully decoupled power and energy components, which allows for affordable scaling options. Together, this allows a substantial amount of creativity to enable the economic utilization of variable power resources while supporting decarbonization of the industry.

08 HYDROGEN↗

Technoeconomic Analysis of Discrete and Unitized Reversible Fuel Cells for Energy Storage Applications

Reversible Fuel Cell (RFC) systems offer promising characteristics for stationary long duration energy storage applications. Two main configurations of RFC systems exist: discrete RFC systems and unitized RFC systems. While discrete RFC systems combine independent fuel cell and electrolyzer systems for energy storage, unitized RFC systems utilize a single electrochemical stack and might share balance of plant (BOP) components for both charging and discharging processes. While this configuration reduces upfront capital costs, challenges of unitized RFC designs include potential performance trade-offs due to dual-mode stack design and operational complexities across varying loads and operating conditions. Furthermore, these tradeoffs might be different for low-temperature PEM RFCs than for high-temperature reversible solid oxide cell systems. The goal of this project is to assess unitized RFC system potential in the context of long duration grid energy storage and HFTO's technical targets for different discrete fuel cell and electrolyzer technologies. This presentation presents preliminary review of state-of-the-art unitized RFC cells and assesses how they perform relative to HFTO's technical targets. It also presents literature-derived system configurations worth investigating. This review indicates that lab-scale unitized RFCs are making good progress towards meeting HFTO's technical targets.

HYDROGEN↗

Durable Thin‐Film Porous Transport Electrodes for High Current Density PEM Water Electrolysis

Proton exchange membrane water electrolyzers rely on relatively expensive Ir-based catalysts for efficient and durable hydrogen production. To reduce system costs, Ir loadings can be reduced if performance and durability are maintained. Sputter deposition is a readily scalable method to synthesize uniform, low-loading catalyst layers with controlled composition. A catalyst applied directly to the porous transport layer can have advantages for performance, manufacturing simplicity, and catalyst recovery. Suitable porous transport layer porosity can minimize activity losses when reducing loadings. Here, methods are presented to deposit metallic Ir as well as amorphous and rutile Ir oxides. The activity and durability of these materials in the porous transport electrode architecture is evaluated. The metallic and amorphous forms have better initial activity, however, operation at 3 A cm −2 with 0.1 mg Ir cm −2 shows that only rutile IrO 2 maintains performance beyond 100 h with a 50 mV improvement after 700 h. A >10x reduced dissolution rate is shown for rutile IrO 2 . With a low-porosity transport layer and 0.4 mg Ir cm −2 , a steady-state voltage decay rate of 6 µV h −1 is achieved. The results demonstrate that sputter-deposited rutile IrO 2 porous transport electrodes with low Ir loading can be operated at high current density to reduce hydrogen production costs.

08 HYDROGEN↗

Carbon Corrosion in CO2 Electrolysis Systems

Driven by concerns over climate change, interest in CO2 conversion technologies has dramatically increased in recent years. By viewing CO2 as a readily available feedstock, many pathways for the production of carbon-neutral fuels and chemicals become available. In converting CO2, low carbon emitting energy sources must be used to ensure a low carbon footprint of the fuel and chemical products. The low-temperature electrochemical conversion of CO2 is a promising technology and allows for direct integration with renewable electricity sources. The development of low-temperature CO2 electrolysis technologies is informed by both PEM fuel cells and water electrolyzers, both of which are at a higher stage of development. However, CO2 electrolysis operates at a much higher cell voltage (-3V) than other low-temperature electrochemical processes, which can have implications for materials compatibility in the electrolyzer device. Carbon corrosion is of particular concern for the anode of CO2 electrolyzers, as a large driving force for corrosion exists due to the high required cell potentials. In this presentation, recent observations will be shared on carbon corrosion of the anode gas diffusion electrode (GDE) in low-temperature alkaline exchange membrane CO2 electrolysis. Results from ex-situ tests designed to isolate the carbon corrosion process for anode GDEs will be shared. These results will provide guidance on materials selection for CO2 utilization MEAs, which need to have a lifetime of several years to ensure industrial viability.

BIOMASS FUELS↗

Mechanical Characterization of Electrolyzer Membranes and Components Under Compression

Proton-exchange membrane (PEM) water electrolysis is a promising technology for producing clean hydrogen by electrochemically splitting water when paired with renewable energy sources. A major roadblock to improving electrolyzer durability is the mechanical degradation of the cell components, which requires an understanding of their mechanical response under device-relevant conditions. However, there is a lack of studies on the mechanical characterization of the PEM and other components, as well as and their interactions. This study aims to address this gap by using a custom-designed testing apparatus to investigate the mechanics of electrolyzer components in uniaxial compression at 25 and 80 °C. Findings show stress-strain response of components have a varying degree of nonlinearity owing to their distinct deformation mechanisms and morphologies, from porous structures to polymers. These results are used to develop an expression for compressive stress-strain response of Nafion membranes and then analyze the deformation of components under applied pressure by using a 1-D spring network model of cell assembly. This work provides a new understanding of mechanical responses of the electrolyzer membrane and cell components, which can help assess material design and cell assembly strategies for improved electrolyzer durability.

08 HYDROGEN↗

LTE-P-3 IEC PEM SOP

A procedure for measuring the ion exchange capacity (IEC) of a proton exchange membrane (PEM).

08 HYDROGEN↗

Pioneering Microporous Layers for Proton-Exchange-Membrane Water Electrolyzers via Tape Casting

The imperative shift towards decarbonization necessitates the production of clean hydrogen through water electrolysis, powered by renewable energy sources. Among electrolyzer technologies, proton-exchange-membrane (PEM) systems emerge as a promising option for large-scale hydrogen generation due to their modular design and rapid response, aligning well with the intermittency of renewable energy. In this study, we employ a tape casting method to fabricate microporous layers (MPLs), both as a single layer and as a bilayer over commercial porous transport layers (PTLs), to further enhance performance of water electrolyzers. We demonstrate that microporous layers require adequate pore sizes to facilitate gas removal, preventing gas flooding and preserving electrolyzer performance. Our single layer microporous layers exhibit lower overpotentials compared to commercial sintered Ti PTLs by 142 mV at 4 A·cm ⁻2 . Moreover, we show that having an effective microporous layer enhances electrolyzer performance irrespective of the substrate used, offering avenues for cost reduction. We also investigate novel PTL structures with reduced tortuosity and integrated MPL fabricated via phase inversion tape casting, resulting in a performance enhancement of 92 mV. Our findings unravel the critical role of microporous layer structures and their impact on electrolyzer performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanochannel electrodes facilitating interfacial transport for PEM water electrolysis

Proton-exchange membrane water electrolyzers (PEMWEs) are a promising technology for green hydrogen production; however, interfacial transport behaviors are poorly understood, hindering device performance and longevity. Here, we first utilized finite-gap electrolyzer to demonstrate the possibility of proton transfer through water in PEMWEs. The measured high-frequency resistances (HFRs) exhibit a linear trend with increasing gap distance, where extrapolation shows a lower value compared with HFRs in regular zero-gap electrolyzers, indicating that ohmic resistance could be further reduced. We introduce nanochannels to facilitate mass transport, as evidenced by both liquid-fed and vapor-fed electrolysis. Nanochannel electrodes achieve a voltage reduction of 190 mV at 9 A·cm –2 compared with the Ir-PTEs without nanochannels. Furthermore, nanochannel electrodes show negligible degradation through 100,000 accelerated-stress tests and over 2,000 h of operation at 1.8 A·cm –2 with a decay rate of 11.66 μV·h –1 . These results provide new insights into localized transport dynamics for PEMWEs and highlight the significance of interfacial engineering for electrochemical devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrolyzers for Hydrogen Production: Solid Oxide, Alkaline, and Proton Exchange Membrane

The effects of climate change have led to a push for cleaner energy sources across multiple sectors. Hydrogen has emerged as a promising energy carrier in this context, as it can be produced using various water electrolysis technologies capable of utilizing clean power (e.g., nuclear and renewable electricity). However, a comprehensive environmental assessment of these technologies requires an understanding of the environmental impacts during their complete life cycle, including the embodied emissions in their material composition and during their manufacturing stages; these emissions are often neglected. This report provides a brief overview of major water electrolysis technologies, viz., proton exchange membrane electrolyzer cell (PEMEC) or polymer electrolyte membrane (PEM), alkaline electrolysis cell (AEC) and solid oxide electrolysis cell (SOEC), along with a detailed bill of materials for these technologies that has been incorporated in the updated G reenhouse gases, R egulated E missions, and E nergy use in T ransportation (GREET ® ) 2022 model. We also provide an inventory for the intermediate materials used to produce these electrolyzers, which has not been covered in prior releases. Using these material and energy flows, the GREET model provides a detailed life cycle inventory (energy use and emissions) from raw material extraction through complete production of electrolyzers for major electrolysis technologies.

08 HYDROGEN↗

Impact of Porous Transport Layer In-Plane Conduction on Spatially Resolved Current and EIS Measurements in a Proton Exchange Membrane Water Electrolyzer

An XY segmented cell was developed for low temperature PEM water electrolysis (PEMWE). The system can assess the local performance by enabling in situ measurements of spatial currents and impedances. In this work, we show through experiments, as well as through modelling work, that the porous transport layer (PTL) must be segmented to eliminate crosstalk. Accurate measurements are only possible when crosstalk is fully eliminated. The XY segmented cell is applied to a case study characterizing the impact of a PTL platinum coating void on spatial performance. The localized performance impact of the coating void is found to be orientation specific: coating voids facing the catalyst layer reduce performance significantly more than coating voids facing the flow field. The results suggest that the tolerances for PTL coating uniformity can be lower at the side facing the flow field. The work showcases the feasibility of the XY segmented cell for impact assessment studies. The presented XY segmented cell enables the characterization of spatial phenomena in PEMWE devices and is envisioned to support modeling efforts and the investigation of manufacturing related tolerances for mass produced PEMWE devices.

08 HYDROGEN↗

Design of non-fluorinated proton exchange membranes from Poly(Terphenyl fluorenyl isatin) with fluorene-linked sulfonate groups and microblock structures

Proton exchange membranes (PEMs) are essential components in energy storage and conversion devices, such as fuel cells and electrolyzers. Here, in this study, we developed a series of non-fluorinated PEMs from poly(terphenyl fluorenyl isatin) with fluorene-pendent disulfonate groups. These polymers feature a microblock structure composed of hydrophobic blocks, hydrophilic blocks, and alternating blocks, arising from the differences in reactivity, concentration, and solubility between the hydrophobic p-terphenyl and hydrophilic disulfonated fluorene monomers. As a result, the sulfonic acid groups are unevenly distributed along the polymer chains, forming densely charged regions (IEC = 3.52 meq/g) with large ion clusters and lightly charged regions (IEC = 2.16 meq/g) with small ion clusters. This microstructure, combined with the degree of sulfonation, significantly influences the overall properties of the membranes, including robust mechanical strength (47.1–63.2 MPa), high thermal stability (up to 270 °C), low swelling ratio (18–25% at 80 °C), and high proton conductivity (136–169 mS/cm in deionized water at 80 °C). The PFLSH60 membrane demonstrated comparable fuel cell performance to Nafion 212. Its hydrogen crossover current density was more than two times lower (0.86 mA/cm 2 for PFLSH60 compared to 1.83 mA/cm 2 for Nafion 212) under testing conditions of 80 °C and 100% RH. This significantly reduced crossover improves fuel utilization in fuel cell stacks. This work offers valuable insights into the design of robust, high-performance PEMs by systematically analyzing the relationships between membrane structure, properties, and performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Performance Fuel Cell and Electrolyzer Membrane Electrode Assemblies (MEAs) for Space Energy Storage Systems

Regenerative fuel cells provide a pathway to energy storage system development that are game changers for NASA missions. The fuel cell/ electrolysis MEA performance requirements 0.92 V/ 1.44 V at 200 mA/cm2 can be met. Fuel Cell MEAs have been incorporated into advanced NFT stacks. Electrolyzer stack development in progress. Fuel Cell MEA performance is a strong function of membrane selection, membrane selection will be driven by durability requirements. Electrolyzer MEA performance is catalysts driven, catalyst selection will be driven by durability requirements. Round Trip Efficiency, based on a cell performance, is approximately 65%.

Plastic Encapsulated Microelectronics (PEM)↗

A novel unitized regenerative proton exchange membrane fuel cell

A difficulty encountered in designing a unitized regenerative proton exchange membrane (PEM) fuel cell lies in the incompatibility of electrode structures and electrocatalyst materials optimized for either of the two functions (fuel cell or electrolyzer) with the needs of the other function. This difficulty is compounded in previous regenerative fuel cell designs by the fact that water, which is needed for proton conduction in the PEM during both modes of operation, is the reactant supplied to the anode in the electrolyzer mode of operation and the product formed at the cathode in the fuel cell mode. Drawbacks associated with existing regenerative fuel cells have been addressed in work performed at Lynntech. In a first innovation, electrodes function either as oxidation electrodes (hydrogen ionization or oxygen evolution) or as reduction electrodes (oxygen reduction or hydrogen evolution) in the fuel cell and electrolyzer modes, respectively. Control of liquid water within the regenerative fuel cell has been brought about by a second innovation. A novel PEM has been developed with internal channels that permit the direct access of water along the length of the membrane. Lateral diffusion of water along the polymer chains of the PEM provides the water needed at electrode/PEM interfaces. Fabrication of the novel unitized regenerative fuel cell and results obtained on testing it will be presented.

Murphy, O. J.↗

A Novel Unitized Regenerative Proton Exchange Membrane Fuel Cell

A difficulty encountered in designing a unitized regenerative proton exchange membrane (PEM) fuel cell lies in the incompatibility of electrode structures and electrocatalyst materials optimized for either of the two functions (fuel cell or electrolyzer) with the needs of the other function. This difficulty is compounded in previous regenerative fuel cell designs by the fact that water, which is needed for proton conduction in the PEM during both modes of operation, is the reactant supplied to the anode in the electrolyzer mode of operation and the product formed at the cathode in the fuel cell mode. Drawbacks associated with existing regenerative fuel cells have been addressed. In a first innovation, electrodes function either as oxidation electrodes (hydrogen ionization or oxygen evolution) or as reduction electrodes (oxygen reduction or hydrogen evolution) in the fuel cell and electrolyzer modes, respectively. Control of liquid water within the regenerative fuel cell has been brought about by a second innovation. A novel PEM has been developed with internal channels that permit the direct access of water along the length of the membrane. Lateral diffusion of water along the polymer chains of the PEM provides the water needed at electrode/PEM interfaces. Fabrication of the novel single cell unitized regenerative fuel cell and results obtained on testing it are presented.

Murphy, O. J.↗

Grid-responsive hydrogen production: Capital utilization and current density vs. efficiency in variable electricity markets

To achieve low-cost hydrogen production from water electrolyzers, grid tied electrolysis may need to operate dynamically to minimize the cost of supplying energy to the electrolyzer stack and produce hydrogen during low-cost hours and turn off/down during high-cost hours. Operating systems in this way can decrease capital utilization (capacity factor) and electricity costs. This strategy would shift the dominant cost drivers away from electricity (and thus efficiency) to the capital costs of the system, due to the underutilized capital when operating at low-capacity factors. Increasing the operational current density of the system could, in effect, reduce the capital cost of the system while producing hydrogen at a lower efficiency on a per unit energy basis. In the variable electricity cost profiles analyzed in this paper, increasing the current density for liquid alkaline from 0.5 A/cm2 to 1.5 Ac/m2 and proton exchange membrane electrolyzers from 2 A/cm2 to 4 A/cm2 resulted in substantial reductions in the levelized cost of hydrogen. Additionally, as capacity factors and electricity costs decrease, the optimal operating current density of the electrolyzer systems analyzed increases. These findings suggest R&D efforts should focus on increasing the operational current densities, reducing the turn down ratios, and understanding the durability implications of those strategies on low-temperature liquid alkaline and proton exchange membrane electrolyzers.

08 HYDROGEN↗