At least 109 records · Page 6

A proposed experimental search for chameleons using asymmetric parallel plates

Light scalar fields coupled to matter are a common consequence of theories of dark energy and attempts to solve the cosmological constant problem. The chameleon screening mechanism is commonly invoked in order to suppress the fifth forces mediated by these scalars, sufficiently to avoid current experimental constraints, without fine tuning. The force is suppressed dynamically by allowing the mass of the scalar to vary with the local density. Recently it has been shown that near future cold atoms experiments using atom-interferometry have the ability to access a large proportion of the chameleon parameter space. In this work we demonstrate how experiments utilising asymmetric parallel plates can push deeper into the remaining parameter space available to the chameleon.

79 ASTRONOMY AND ASTROPHYSICS↗

Estimation of Cs Migration under an Unsaturated Condition by Parallel-plate Experiments and 2D Advection-dispersion Model - 17188

For the assessment of the radioactive waste facility in the near-surface underground, it is important to consider the influence of the unsaturated condition flow field (hereinafter referred to as unsaturated condition) on the migration of radionuclides through the porous medium. The unsaturated condition, which is not completely saturated with liquid phase, will change the retardation effect for the migration of nuclides by interrupting the interaction of nuclides and solid phase, and by clogging flow paths with gas phase. In this study, considering the spatial distribution of the water saturation, the migration of radionuclides in the two-dimensional (2D) porous medium under the saturated flow field (hereinafter referred to as saturated condition) and unsaturated condition was examined by using the parallel-plate type's packed bed and the 2D advection-dispersion model. Besides, for comparison, the one-dimensional (1D) flow experiment using the column type's packed bed was also examined. In the experiments, a 1 mM Cs solution was injected into the beds packed with silica sand under a given constant pressure condition controlled by an overflow system. The overall effective values of retardation coefficient were estimated by applying the theoretical models to the experimental results. As a result, the overall retardation coefficient under the unsaturated condition became smaller than that under the saturated condition. This means the decrease in the effective surface area for the sorption of tracer ions in the presence of gas phase. Furthermore, under the unsaturated condition, the retardation coefficient of the 2D flow condition was estimated smaller than that of the 1D condition. That is, in the 2D flow system, the tracer ions migrate through more selective flow-paths caused by the heterogeneous spatial-distribution of water saturation which is the ratio of the volume of water to the volume of pores. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The heat transfer coefficient associated with a moving packed bed of silica particles flowing through parallel plates

Concentrating Solar Power (CSP) with thermal energy storage has the potential to be a renewable energy technology with long duration, inexpensive energy storage. Higher temperature operation increases the conversion efficiency and reduces the cost of energy storage. Several emerging CSP designs utilize particles as the solar receiver due to their high temperature stability and low cost. In some designs, the particles are also used as the thermal energy storage (TES) media. In either configuration, an energy transfer is required between the hot particles and the working fluid in the power cycle in a Particle-to-Fluid Heat Exchanger (PtFHX). Understanding the heat transfer between a moving packed bed and a stationary surface is critical to the successful design of a PtFHX. In this paper, a test facility is described in which a moving packed bed of silica sand with particle size 100–600 μm is introduced into the channel formed by two parallel plates, one of which is heated. The effective static thermal conductivity of the particles used for the test are separately measured over the entire range of test temperatures. The inlet and outlet bulk temperatures of the particle flow are measured as are the surface temperatures at several axial locations along the centerline of the plate. The result is the measurement of heat transfer coefficient as a function of temperature for several velocities. The uncertainty of the measurements is presented and the results are compared to model results found in the literature.

14 SOLAR ENERGY↗

CHICO2, a two-dimensional pixelated parallel-plate avalanche counter

CHICO 2 (Compact Heavy Ion COunter), is a large solid-angle, charged-particle detector array developed to provide both θ and Φ angle resolutions matching those of GRETINA (Gamma-Ray Energy Tracking In-beam Nuclear Array). CHICO 2 was successfully tested at the Argonne National Laboratory where it was fielded as an auxiliary detector with GRETINA for γ-ray spectroscopic studies of nuclei using a 252 Cf spontaneous fission source, stable beams, and radioactive beams from CARIBU. In field tests of the 72,76Ge beams on a 0.5 mg/cm 2 208Pb target at the sub-barrier energy, CHICO 2 provided charged-particle angle resolutions (FWHM) of 1.55° in θ and 2.47° in Φ. This achieves the design goal for both coordinates assuming a beam-spot size (>3 mm) and the target thickness (>0.5 mg/cm 2 ). The combined angular resolution of GRETINA/CHICO 2 resulted in a Doppler-shift corrected energy resolution of 0.60% for 1 MeV coincident de-excitation γ-rays. This is nearly a factor of two improvements in resolution and sensitivity compared to Gammasphere/CHICO. Kinematically-coincident detection of scattered ions by CHICO 2 still maintains the mass resolution (ΔM/M) of ~5% that enhanced isolation of scattered weak beams of interest from scattered contaminant beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Beam quality conversion factors for parallel-plate ionization chambers in MV photon beams

Purpose: To investigate the behavior of plane-parallel ion chambers in high-energy photon beams through measurements and Monte Carlo simulations. Methods: Ten plane-parallel ion chamber types were obtained from the major ion chamber manufacturers. Absorbed dose-to-water calibration coefficients are measured for these chambers and k{sub Q} factors are determined. In the process, the behaviors of the chambers are characterized through measurements of leakage currents, chamber settling in cobalt-60, polarity and ion recombination behavior, and long-term stability. Monte Carlo calculations of the absorbed dose to the air in the ion chamber and absorbed dose to water are obtained to calculate k{sub Q} factors. Systematic uncertainties in Monte Carlo calculated k{sub Q} factors are investigated by varying material properties and chamber dimensions. Results: Chamber behavior was variable in MV photon beams, especially with regard to chamber leakage and ion recombination. The plane-parallel chambers did not perform as well as cylindrical chambers. Significant differences up to 1.5% were observed in calibration coefficients after a period of eight months although k{sub Q} factors were consistent on average within 0.17%. Chamber-to-chamber variations in k{sub Q} factors for chambers of the same type were at the 0.2% level. Systematic uncertainties in Monte Carlo calculated k{sub Q} factors ranged between 0.34% and 0.50% depending on the chamber type. Average percent differences between measured and calculated k{sub Q} factors were - 0.02%, 0.18%, and - 0.16% for 6, 10, and 25 MV beams, respectively. Conclusions: Excellent agreement is observed on average at the 0.2% level between measured and Monte Carlo calculated k{sub Q} factors. Measurements indicate that the behavior of these chambers is not adequate for their use for reference dosimetry of high-energy photon beams without a more extensive QA program than currently used for cylindrical reference-class ion chambers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Theoretical and experimental investigation of heat transfer by laminar natural convection between parallel plates

Results are presented of a theoretical and experimental investigation of heat transfer involving laminar natural convection of fluids enclosed between parallel walls oriented in the direction of the body force, where one wall is heated uniformly, and the other is cooled uniformly. For the experimental work, parallel walls were simulated by using an annulus with an inner-to-outer diameter ratio near 1. The results of the theoretical investigation are presented in the form of equations for the velocity and temperature profiles and the ratio of actual temperature drop across the fluid to the temperature drop for pure conduction. No experimental measurements were made of the velocity and temperature profiles, but the experimental results are compared with theory on the basis of the ratio of the actual temperature drop to the temperature drop for pure conduction. Good agreement was obtained between theory and experiment for axial temperature gradients of 10 degrees F. per foot or larger.

Lietzke, A F↗

Parallel-plate viscometer

Viscometer consists of movable vertical rod with one optical flat fixed to its lower end and centered over second optical flat held rigidly parallel to moveable flat. Two perforated diaphragms of thin metal permit limited amount of vertical movement of rod carrying movable flat, but resist lateral movement.

Fearnehough, H. T.↗

Lateral distribution of pulse height in a parallel-plate avalanche counter

The nuclear γ-ray spectroscopy enters a new era when the first engineering run of GRETINA [1], a new generation of γ-ray tracking arrays, was successfully carried out at LBNL in early April, 2011. A parallel effort has been setup to develop the auxiliary charged-particle detector arrays with a matching position resolution to fully exploit the potential of GRETINA. Improving the position resolution of the existing charged-particle detector array, CHICO [2], is a part of this coordinated effort. The proposal to upgrade CHICO was approved by DOE/SC at the end of FY10. The goal is to redesign the cathode board and amplifier to improve the resolution for both and coordinates to better than one degree to match that of GRETINA. This project is scheduled to complete by the summer of 2012.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of the Mutual Inductance between Two Parallel Plates for the Detection of Surface Flaws

There has recently been much effort behind the development of NDE methods applicable to the detection of surface/subsurface flaws in thin metallic structures with a rapid scan capability. One such method, an electromagnetic technique using a current-sheet parallel to the surface of a specimen in order to induce eddy current flow shows a high potential for satisfying the rapid scan requirement stated above. The technique is based on the detection of flaw-induced magnetic field components normal to the specimen surface by an appropriate detection mechanism positioned above the current-sheet as shown schematically in Fig. 1. As indicated in this figure, the current-sheet separates the source of the normal magnetic field components from the detector in such a way that the electric and magnetic properties of the current-sheet can be a major factor affecting the strength of the detected signals. The purpose of the present study is, therefore, to perform a detailed investigation on the effect of the material properties of the current-sheet on the detected signal strength and to establish a simple theoretical model for the detection mechanism.

Namking, M.↗

Parallel-plate submicron gap formed by micromachined low-density pillars for near-field radiative heat transfer

Near-field radiative heat transfer has been a subject of great interest due to the applicability to thermal management and energy conversion. In this letter, a submicron gap between a pair of diced fused quartz substrates is formed by using micromachined low-density pillars to obtain both the parallelism and small parasitic heat conduction. The gap uniformity is validated by the optical interferometry at four corners of the substrates. The heat flux across the gap is measured in a steady-state and is no greater than twice of theoretically predicted radiative heat flux, which indicates that the parasitic heat conduction is suppressed to the level of the radiative heat transfer or less. The heat conduction through the pillars is modeled, and it is found to be limited by the thermal contact resistance between the pillar top and the opposing substrate surface. The methodology to form and evaluate the gap promotes the near-field radiative heat transfer to various applications such as thermal rectification, thermal modulation, and thermophotovoltaics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Flow of a binary mixture of linearly incompressible viscous fluids between two horizontal parallel plates

In this paper, we use the classical Mixture Theory and present exact solutions to the equations of motion for the steady flow of two linearly viscous fluids between two horizontal plates. We show that for a saturated mixture and under very special conditions, namely when the body forces are assumed negligible, the only interaction force is due to relative velocity (drag force), and if the two velocities are assumed to be related to each other in a linear fashion, then it is possible to integrate the coupled ordinary differential equations and obtain analytical expressions for the velocities and the volume fraction.

42 ENGINEERING↗

Design and performance of A 3 He-free coincidence counter based on parallel plate boron-lined proportional technology

Thermal neutron counters utilized and developed for deployment as non-destructive assay (NDA) instruments in the field of nuclear safeguards traditionally rely on 3He-based proportional counting systems. 3 He-based proportional counters have provided core NDA detection capabilities for several decades and have proven to be extremely reliable with range of features highly desirable for nuclear facility deployment. Facing the current depletion of 3He gas supply and the continuing uncertainty of options for future resupply, a search for detection technologies that could provide feasible short-term alternative to 3 He gas was initiated worldwide. As part of this effort, Los Alamos National Laboratory (LANL) designed and built a 3 He-free full scale thermal neutron coincidence counter based on boron-lined proportional technology. The boronlined technology was selected in a comprehensive inter-comparison exercise based on its favorable performance against safeguards specific parameters. This paper provides an overview of the design and initial performance evaluation of the prototype High Level Neutron counter – Boron (HLNB). The initial results suggest that current HLNB design is capable to provide ~80% performance of a selected reference 3 He-based coincidence counter (High Level Neutron Coincidence Counter, HLNCC). Similar samples are expected to be measurable in both systems, however, slightly longer measurement times may be anticipated for large samples in HLNB. The initial evaluation helped to identify potential for further performance improvements via additional tailoring of boron-layer thickness.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Two-Fluid and Discrete Element Modeling of a Parallel Plate Fluidized Bed Heat Exchanger for Concentrating Solar Power

A novel high-temperature particle solar receiver is developed using a light trapping planar cavity configuration. As particles fall through the cavity, the concentrated solar radiation warms the boundaries of the receiver and in turn heats the particles. Particles flow through the system, forming a fluidized bed at the lower section, leaving the system from the bottom at a constant flowrate. Air is introduced to the system as the fluidizing medium to improve particle heat transfer and mixing. A laboratory scale cavity receiver is built by collaborators at the Colorado School of Mines and their data are used for model validation. In this experimental setup, near IR quartz lamp is used to provide flux to the vertical wall of the heat exchanger. The system is modeled using the discrete element method and a continuum two-fluid method. The computational model matches the experimental system size and the particle size distribution is assumed monodisperse. A new continuum conduction model that accounts for the effects of solid concentration is implemented, and the heat flux boundary condition matches the experimental setup. Radiative heat transfer is estimated using a widely used correlation during the post-processing step to determine an overall heat transfer coefficient. The model is validated against testing data and achieves less than 30% discrepancy and a heat transfer coefficient greater than 1000 W/m2 K.

concentrating solar power↗