Engineering PapersSearch

SEARCH · Engineering Papers

Results for “PACE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

256 x 256 PACE-1 PV HgCdTe focal plane arrays for medium and short wavelength infrared applications

The development of two 256 by 256 hybrid HgCdTe focal plane array (FPA) families is described, and their performance is discussed. The hybrid FPAs employ a PV HgCdTe detector array and custom Si CMOS readouts. The PACE-1 process was used to fabricate the detectors, whereby the liquid phase epitaxial growth of HgCdTe occurs on sapphire substrates buffered by a layer of CdTe. The performance characteristics of the detector arrays are given. A tactical 256 by 256 CMOS readout is tested, in which a high functional yield was achieved. Updated test results are given for a 256 by 256 readout circuit developed for use in an orbital replacement instrument for the Hubble Space Telescope. The characterizations of several MWIR and SWIR FPAs were thorough and shown to be reliable. The pixel yield, maximum FPA responsivity nonuniformity, and SWIR FPA read noise for the tests are given. The high contrast and insignificant fixed pattern noise of the imagery from the MWIR 256 by 256 FPA are emphasized. These qualities were obtained when the device was operating at 80 k and utilizing f/2 optics with an 8-in. focal length and a 4.4 micron high pass filter.

Kozlowski, L. J.

PACE and EISCAT radar observations of short-lived flow bursts on the nightside

Concurrent observations from two widely spaced radar experiments of quasi periodic flow bursts in the nightside are presented. The flow bursts closely resemble single radar observations reported by Williams et al. By using the Polar Anglo-American Conjugate Experiment (PACE) HF radar array at Halley Bay in conjunction with the EISCAT Common Program (CP) 2-D experiment, the flow bursts are shown to be a global phenomenon and important information as to their development and propagation can be determined.

Freeman, M. P.

PACES Participation in Educational Outreach Programs at the University of Texas at El Paso

The University of Texas at El Paso (UTEP) is involved in several initiatives to improve science education within the El Paso area public schools. These include outreach efforts into the K- 12 classrooms; training programs for in-service teachers; and the introduction of a strong science core curricula within the College of Education. The Pan American Center for Earth and Environmental Studies (PACES), a NASA-funded University Research Center, will leverage off the goals of these existing initiatives to provide curriculum support materials at all levels. We will use currently available Mission to Planet Earth (MTPE) materials as well as new materials developed specifically for this region, in an effort to introduce the Earth System Science perspective into these programs. In addition, we are developing curriculum support materials and classes within the Geology and Computer Departments, to provide education in the area of remote sensing and GIS applications at the undergraduate and graduate levels.

Dodge, Rebecca L.

TCP Pacing Developed

Transmission control protocol (TCP) was conceived and designed to run over a variety of communication links, including wireless and high-bandwidth links. However, with recent technological advances in satellite and fiber-optic networks, researchers are reevaluating the flexibility of TCP. The TCP pacing and packet pair probing implementation may help overcome two of the major obstacles identified for efficient bandwidth utilization over communication links with large delay-bandwidth products.

Ivancic, William D.

The Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) Mission and Its Polarimeters: An Overview

Key characteristics of the PACE observatory include: the Ocean Color Instrument (OCI), built at GSFC; the Hyper Angular Rainbow Polarimeter (HARP-2), contributed by the Earth and Space Institute at the University of Maryland Baltimore County; the Spectro-polarimeter for Planetary Exploration (SPEXone), contributed by a Netherlands-based consortium consisting of the Netherlands Institute for Space Research (SRON) and Airbus Defence and Space Netherlands; 676.5 km altitude and 13:00 local Equatorial crossing time; Sun synchronous, polar, ascending orbit with 98º inclination; and fall 2022 launch, three-year design life.

Cairns, Brian

New Global Ocean Color Sensor: OCI on PACE

- OCI will provide TOA radiances at ~1km spatial resolution, from 340nm (315nm?) to 2260nm, hyperspectral from 340nm to 890nm, 2 day global coverage - OCI will continue and enhance NASA’s earth system data records for ocean color (heritage sensors: SeaWiFS, MODIS, VIIRS) - OCI flight unit is close to being ready for testing (planned for March 2022 to September 2022) - OCI ETU (Engineering Test Unit) completed testing summer 2021, results look promising (see next presentation) - On-orbit calibration will combine successful trending approaches from previous sensors (2 solar diffusers, QVD, lunar gain trending, spectral trending) - New calibration approaches for OCI: large QVD, dim diffuser for linearity trending, lunar hysteresis trending - OCI will be characterized prelaunch with an ambitious goal of 0.5% relative uncertainty; absolute uncertainty will be about 2% (before vicarious calibration); expected on-orbit gain trending accuracy is 0.2% or better - More info on PACE and OCI can be found at https://pace.oceansciences.org/

radiometer

Lessons Learned From Evaluation and Mitigation of Space Charging Threat Due to Use of Isolated (Hybrid) Bearings on the Pace Ocean Color Instrument

A high precision, high resolution Ocean Color Instrument (OCI) was developed for the Plankton, Aerosol, Cloud ocean Ecosystem (PACE) mission which required the use of electrically isolated Hybrid Bearings (silicon nitride balls). While desirable for technical performance of the instrument, this application caused portions of the instrument to become electrically isolated and come under threat of space charging effects from charged particles and the resultant differential charging. An evaluation of the environment, susceptibility of the components, such as bearings and electronics, and mitigation strategies were performed. As part of that process, simulations of the charging environment, analysis of internal mechanism charging and prediction of most likely discharge paths, testing of the bearings for susceptibility as well as resulting damage were performed and analyzed. Additionally, a novel method to deal with charging was developed. Considerations for dealing with electrically isolated mechanisms, results of the above-mentioned efforts as well as lessons learned are presented.

space charging

Instrument Level TVAC Testing of the PACE OCI Loop Heat Pipes

The Thermal Control System (TCS) of the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) Ocean Color Instrument (OCI) incorporates two propylene Loop Heat Pipes (LHP). A Thermal Vacuum (TVAC) test was conducted at NASA Goddard Space Flight Center to characterize the fully integrated OCI in the test-as-you-fly configuration. Within the constraints of movement of the OCI in the TVAC chamber, an elaborate series of trending and calibration tests have been accomplished. This paper presents the measured LHP performance along with lessons learned.

loop heat pipe

Spectral Measurement Errors due to CCD Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a hyperspectral imager with a spatial resolution of 1km x 1km and spectral resolution of 5nm in 2.5nm steps over 320-890nm. The detection system is based on two Charge-Coupled Devices (CCDs) operating in Time Delay Integration (TDI) mode to achieve high signal-to-noise ratio. The front-end optical imager is a rotating mirror-based system that images the ground-scene onto a slit with a field of view of 16km x 1km. The slit-image is re-imaged and wavelength dispersed on the CCDs. As the ground-scene moves through the slit, it moves along the CCD columns as charge is moved along with it. The accumulated charge at the end of each column is collected in a serial pixel. Each of the 16 CCD outputs read out 32 columns of the same ground scene spaced 0.625nm apart. The 32-pixel serial register is swiftly read out before the next TDI cycle. The telescope is spinning at 5.77Hz to achieve the required spatial resolution. This results in a serial pixel readout speed of 8.5MHz. Each serial read-cycle goes through a reset and video period that are each sampled to create a low-noise correlated double sample value. This only allows 59ns for the reset and video to be asserted and settled before sampling. Due to the short time period, the response of the CCD exhibits serial pixel-to-pixel readout interference as the reset and video signals do not have time to fully settle before sampling. Each serial pixel value therefore has a dependence on the value of the preceding pixel value. This leads to a spectral measurement error of up to 0.3%. We explain the operation of the detection system, the behavior of the interference and the resulting wavelength error with results from ground testing and on-orbit characterization.

Ulrik B Gliese

Spectrally Dependent Radiometric Measurement Errors Due to Ccd Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a 322 887 nm hyperspectral imager with 1 km x 1 km nadir spatial resolution and 5 nm spectral resolution utilizing charge-coupled devices (CCDs) operating in Time Delay Integration (TDI) mode where each TDI column represents a different wavelength in 0.625 nm increments. After TDI, the charge is moved into serial output pixels and read out. The spatial resolution requires an 8.5 MHz readout rate. This only allows 59 ns for the CCD reset and video to be asserted and settled before sampling. The response exhibits serial pixel-to-pixel readout interference due to the lack of full settling. Each serial pixel value has a dependence on the value of the preceding pixel value. This leads to a spectrally dependent radiometric measurement error of up to 0.3 %. We explain the operation of the detection system, the behavior of the interference, and show the resulting measurement error based on data from both ground testing and on-orbit characterization.

Remote Sensing

On-Orbit OCI Characterization Measurements from the first 6 Months of the PACE Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission has been providing data to the science community since April 2024. OCI is a hyperspectral imager, providing almost daily global coverage, at a spatial resolution of 1.2km. Its design specifications were optimized for ocean color and atmospheric applications, but terrestrial studies could benefit from its hyperspectral coverage as well. The ocean color requirements called for very high radiometric accuracy, which could benefit a wide variety of applications. This paper presents results from the first 6 months of on-orbit calibration and characterization measurements, including absolute calibration, spectral registration, temporal trending of radiometric sensitivity, signal to noise ratio, and linearity, with a focus on the commissioning results obtained in the first 2 months after launch.

calibration

On-Orbit OCI Characterization Measurements from the first 6 Months of the PACE Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission has been providing data to the science community since April 2024. OCI is a hyperspectral imager, providing almost daily global coverage, at a spatial resolution of 1.2km. Its design specifications were optimized for ocean color and atmospheric applications, but terrestrial studies could benefit from its hyperspectral coverage as well. The ocean color requirements called for very high radiometric accuracy, which could benefit a wide variety of applications. This paper presents results from the first 6 months of on-orbit calibration and characterization measurements, including absolute calibration, spectral registration, temporal trending of radiometric sensitivity, signal to noise ratio, and linearity, with a focus on the commissioning results obtained in the first 2 months after launch.

calibration

Spectrally Dependent Radiometric Measurement Errors Due to CCD Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a 322 887 nm hyperspectral imager with 1 km x 1 km nadir spatial resolution and 5 nm spectral resolution utilizing charge-coupled devices (CCDs) operating in Time Delay Integration (TDI) mode where each TDI column represents a different wavelength in 0.625 nm increments. After TDI, the charge is moved into serial output pixels and read out. The spatial resolution requires an 8.5 MHz readout rate. This only allows 59 ns for the CCD reset and video to be asserted and settled before sampling. The response exhibits serial pixel-to-pixel readout interference due to the lack of full settling. Each serial pixel value has a dependence on the value of the preceding pixel value. This leads to a spectrally dependent radiometric measurement error of up to 0.3 %. We explain the operation of the detection system, the behavior of the interference, and show the resulting measurement error based on data from both ground testing and on-orbit characterization.

Remote Sensing

PACE OCI Straylight and Crosstalk Evaluation using Moon

The Ocean Color Instrument (OCI) onboard NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission has performed three monthly lunar calibrations. The moon is an extended source over a large dark background, making it an ideal target for evaluating OCI’s straylight and crosstalk performance. The lunar data analysis showed the straylight and crosstalk to be lower than the prelaunch measurements, especially in the along-track direction, where very little straylight is detected. Based on lunar data, the prelaunch measured crosstalk coefficients were reduced, and a crosstalk correction was tested on both lunar and solar calibration data. Applying the revised crosstalk correction, the crosstalk contaminations are significantly reduced to under 0.1% at 2-3 pixels away from the lunar boundary for bands above 350 nm. Below 350 nm, the crosstalk correction residuals gradually increase due to a lack of high-quality prelaunch measurements. Lastly, applying the crosstalk correction changes the calibrated radiance for all science data. This is due to the different spectral shapes between the solar diffuser and the observed scenes. For the moon, the crosstalk correction has an impact of ~0.4% on the overall calibrated radiance for the 400 – 600 nm bands and up to 20% impact on the UV bands.

Shihyan Lee