Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Oxygen Consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

North‐East Peri‐Tethyan Water Column Deoxygenation and Euxinia at the Paleocene Eocene Thermal Maximum

Abstract The Paleocene–Eocene Thermal Maximum (PETM) is associated with climatic change and biological turnover. It shares features with the Oceanic Anoxic Events (OAEs) of the Mesozoic, such as transient global warming and biogeochemical perturbations. However, the PETM experienced a more muted expansion of marine anoxia compared to the Mesozoic OAEs (especially OAE2), with geographically limited evidence for photic zone euxinia (PZE). We explore the extent and drivers of marine deoxygenation during the PETM using biomarkers for water column euxinia and anoxia as well as an intermediate complexity Earth system model (cGEnIE). These reveal that the water column in the North‐East Peri‐Tethys became anoxic, with euxinic conditions reaching the photic zone (PZE) during the PETM. Our model shows that euxinia developed due to a global increase in the ocean nutrient inventory with concomitant oxygen consumption, similar to findings for OAE2. The particularly strong regional response in the NE Peri‐Tethys appears to arise from a combination of global CO 2 ‐weathering forcing, regionally restricted circulation and upwelling of sulphidic thermocline waters. Unlike OAE2, anoxia and PZE do not become widespread in our PETM simulations, consistent with new and existing geochemical and biological proxy data. This globally muted response could result from reduced biogeochemical feedbacks to climate forcing relative to the mid‐Cretaceous climate. Our observations suggest that similar mechanisms operated in response to disparate Cenozoic (PETM) and Mesozoic (OAEs) transient global warming events, while also highlighting that background conditions are crucial in modulating the sensitivity of Earth's system to them.

Behrooz, L.↗

Suppressing proximity effects during rapid serial two-photon lithography through tuning of reaction–diffusion kinetics

The ability of two-photon lithography (TPL) to print deterministic nanoporous 3D structures is highly valuable for many applications. However, it is challenging to print such structures rapidly due to the proximity effects that cause closely spaced features to enlarge and merge. A key challenge is the limited understanding of the origins and spatiotemporal dynamics of the long-range proximity effects that extend beyond the optical focal spot. Here, we empirically investigate these proximity effects in serial TPL using custom-made acrylate-based photoresists. We demonstrate that the complex spatiotemporal dynamics of the proximity effects can be explained through the kinetics of the reaction–diffusion photopolymerization mechanisms that underlie the curing process. Specifically, we show that the proximity effects arise due to comparable timescales of reaction and diffusion of oxygen. Furthermore, we demonstrate that long-range proximity effects can be suppressed by introducing phenolic inhibitors, which reduce oxygen consumption through non-inhibiting side reactions and promote faster termination of curing reactions. These insights enabled improving the linewidths from >400 to 260 nm during printing of nanoporous 3D woodpiles at scanning speeds of 50 mm s −1 . Thus, the knowledge generated here can be applied to deterministically tune the proximity effects and enable rapid printing of high-resolution nanoporous 3D structures.

36 MATERIALS SCIENCE↗

A Systematic Review and Meta-Analysis of Tai Chi Training in Cardiorespiratory Fitness of Elderly People

Objectives. The purpose of this study was to investigate the influence of Tai Chi on cardiorespiratory fitness (CRF) in elderly people using meta-analysis. Methods. This study used seven electronic databases and data retrieved from randomized controlled trials (RCTs) investigating the role of Tai Chi on CRF in the elderly. All these 24 RCTs were screened and selected from 7 literature databases. The Stata 11.2 software (StataCorp, USA) was used for the meta-analysis, subgroup analysis, and bias test, while the Cochrane Collaboration’s tool was used for the assessment of the risk of bias (RoB). 4 researchers independently participated in sample selection, data extraction, and RoB assessment. Results. Following the inclusion criteria, 24 eligible studies were included in our analysis. The meta-analysis indicated that Tai Chi practice significantly increased the maximum rate of oxygen consumption (VO2 max) (weighted mean difference (WMD) = 3.76, 95% CI: 1.25 to 6.26, P < 0.1 ), leading to an overall reduction in the heart rate (HR) (WMD = −1.84, 95% CI: −2.04 to −1.63, P ≤ 0.001 ) and an increase in the O2 pulse (WMD = 0.94, 95% CI: 0.60 to 1.28, P ≤ 0.001 ) in individuals who practiced Tai Chi regularly compared with those who did not. The subgroup analysis suggested that overall in those who practiced Tai Chi, males (WMD = 1.48, 95% CI: 0.85 to 2.12, P ≤ 0.001 ) had higher O2 pulse than females (WMD = 0.73, 95% CI: 0.33 to 1.12, P ≤ 0.001 ). The subgroup analysis also showed an increase in the vital capacity (VC) (WMD = 316.05, 95% CI: 239.74 to 392.35, P ≤ 0.001 ) in individuals practicing Tai Chi. When the samples were further stratified by Tai Chi practicing time, the subgroup analysis suggested that individuals practicing Tai Chi over a period of 24 weeks showed no significant difference in VC (WMD = 82.95, 95% CI: -98.34 to 264.23, P = 0.370 ), while those practicing Tai Chi over a period of 48 weeks showed a significant increase (WMD = 416.62, 95% CI: 280.68 to 552.56, P ≤ 0.001 ). Furthermore, the subgroup analysis demonstrated that the increase in VC is significantly correlated with the Tai Chi practicing time (WMD = 344.97, 95% CI: 227.88 to 442.06, P ≤ 0.001 ). Conclusion. Regular Tai Chi practice could improve the CRF in the elderly, as indicated by significant improvement in indicators including VO2max, O2pulse, VC, and HR. However, gender and practice time might influence the overall beneficial outcomes.

Tan, Tianyang↗

Occupational Experience Effects on Physiological and Perceptual Responses of Common Soldiering Tasks

Abstract Cohen BS, Redmond JE, Haven CC, Foulis SA, Canino MC, Frykman PN, Sharp MA. Occupational Experience Effects on Physiological and Perceptual Responses of Common Soldiering Tasks. J Strength Cond Res 37(4): 894–901, 2023—This study measured the impact of occupational experience (i.e., time spent deployed, in military service, and in job and task performance frequency in training, deployment, and study practice) on the physiological (heart rate [HR] and oxygen consumption [VO 2 ]) and perceptual (rate of perceived exertion [RPE]) responses to performance of critical physically demanding tasks (CPDTs). Five CPDTs (road march, build a fighting position, move under fire, evacuate a casualty, and drag a casualty to safety), common to all soldiers, were performed by 237 active duty soldiers. Linear regression models examined the association between measures of experience and physiological and perceptual performance responses to task demands. The level of significance was adjusted for multiple comparisons and set at ρ ≤ 0.0125 for this study. Significant and notable effect sizes included the impact of time spent deployed on the physiological measures of the road march (PostHR F = 24.84, p < 0.0001, β=-9.65), sandbag fill (PostHR F = 8.26, p = 0.005, β = −2.83), and sandbag carry (MeanHR F = 7.51, p = 0.007, β = −1.12; PostHR F = 7.35, p = 0.007, β = −0.87). For the road march task, there was a nearly 10 bpm decrease in postperformance HR for every year spent deployed. Road march, sandbag fill, and sandbag carry tasks PostHRs were also notably negatively associated with the experience measures of time in their MOS (job and time in military service but not for other physiological and perceptual responses, including VO 2 and RPE. Frequency of task performance in training, deployment, and study practice was not meaningfully associated with experience. The results suggest that increasing task familiarization through on-the-job occupational operational experience may result in greater proficiency and reduced physiological effort.

Sport Sciences↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2020 Status Report)

Leak testing experiments to monitor the aging performance of Viton GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. In addition, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 °F for 12 to 14 years or aging at 270 °F for 8.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 10 to 10.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicates margin remains for O-rings still in service. Aging and periodic leak testing will continue for the remaining PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model 9975 O Ring Fixture LongTerm Leak Performance (FY2021 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 19 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 9.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 11.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 26 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2022 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 10.4 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 12.5 years. This year, one GLT-S O-ring fixture failed after 12.4 years aging at 200 °F. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 25 mock-up PCV fixtures.

36 MATERIALS SCIENCE↗

Development of SAM Code Capabilities for Safety Analysis of GCR Air-ingress Events

Air-ingress following a depressurized loss-of-forced-cooling (DLOFC) event is a challenging, multiphysics safety scenario for High-Temperature Gas-Cooled Reactors (HTGRs), involving coupled gas composition transport, buoyancy-driven flow redistribution, graphite oxidation, and structural heat-up. Despite its importance — air ingress is a key scenario identified in the PIRT process for the HTGRs — existing system-level safety codes have lacked the integrated capability to simulate the complete event sequence with high confidence. This report documents the development, validation, and demonstration of three new capabilities in the SAM code to address this gap: (1) a multi-component gas mixture flow model with binary diffusion to track the helium-air composition and its effect on system density and flow; (2) a 0-D graphite oxidation model based on the Roes correlation, including oxygen consumption and exothermic heat release; and (3) an isentropic critical flow model for accurate representation of primary system depressurization through a break. These capabilities are validated against two benchmark experiments. The NSTF heavy-gas ingress experiment validates the multi-component flow model: SAM correctly reproduces the rapid buoyancydriven flow stagnation and subsequent natural circulation recovery driven by composition-dependent density changes. The NACOK graphite oxidation experiment validates the oxidation model: SAM predicts a bottom-level graphite weight loss of 25%, in close agreement with the measured 24%, and reproduces the strong axial nonuniformity and block-geometry dependence of oxidation, at a level comparable to the SPECTRA and TINTE codes. The validated capabilities are then exercised together in an integrated, reactor-scale simulation of a DLOFC air-ingress transient in a simplified HTR-PM pebble-bed reactor. In a single calculation spanning approximately 8 days, SAM reproduces the complete accident sequence: rapid depressurization, densityand diffusion-driven air ingress over ˜15 hours, onset of buoyancy-driven natural circulation, exothermic graphite oxidation with a peak fuel temperature at ˜62 hours, and eventual passive cooldown. These results demonstrate that SAM now provides the nuclear community with a preliminarily validated, modern systemlevel tool for HTGR air-ingress safety analysis, filling a recognized capability gap. Future extensions to broaden species tracking, improve oxidation chemistry, and refine the reactor model are discussed.

Yang, Gang↗

Potato respirometer experiment SO61

The design and manufacture of a respirometer for measuring the oxygen consumption rate of a respiring potato sprout in a Skylab experiment is reported. The device monitors low gravity effects on the biorhythmicity of organisms during space flight. Several experimental runs using bench mounted flight hardware units were inconclusive due to room temperature induced artifacts.

Taudvin, P. C.↗