Enhanced resonant nonlinear absorption and optical limiting in Er3+ ions doped multicomponent tellurite glasses

Highlights: • Nonlinear optical properties of TPBKZFEr glasses investigated by Z-scan technique. • Optical limiting property of the TPBKZFEr glasses is studied for the first time. • Nonlinearity of the prepared glasses found to be enhanced with Er{sup 3+} concentration. • The mechanism behind the nonlinear properties is successfully explained. • It is evident that these glasses can be developed as tunable optical limiters. - Abstract: Nonlinear optical properties of multicomponent tellurite glasses doped with Er{sup 3+} ions were investigated by open aperture Z-scan measurements. Compositional and linear optical properties of the glasses were examined by the energy dispersive X-ray spectrum and UV–vis–NIR absorption spectrum analysis respectively. The mechanism behind the optical nonlinearity and optical limiting efficiency was successfully explained by evaluating the physical properties such as density, refractive index and polarizability of the glasses. The nonlinear properties critically depend on the polarizability, which is found to increase with the addition of Er{sup 3+} ions by the creation of non-bridging oxygen ions. By the systematic addition of Er{sup 3+} ions, we have dictated the physical properties and thus tuned the optical limiting efficiency of the glasses. This makes the Er{sup 3+}-doped multicomponent tellurite glasses flexible tunable optical limiters for potential device applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical Imaging and Spectroscopic Characterization of Self-Assembled Environmental Adsorbates on Graphene

Topographic studies using scanning probes have found that graphene surfaces are often covered by micron-scale domains of periodic stripes with a 4 nm pitch. These stripes have been variously interpreted as structural ripples or as self-assembled adsorbates. We show that the stripe domains are optically anisotropic by imaging them using a polarization-contrast technique. Optical spectra between 1.1 and 2.8 eV reveal that the anisotropy in the in-plane dielectric function is predominantly real, reaching 0.6 for an assumed layer thickness of 0.3 nm. Furthermore, the spectra are incompatible with a rippled graphene sheet but would be quantitatively explained by the self-assembly of chainlike organic molecules into nanoscale stripes.

36 MATERIALS SCIENCE↗

Photo-electrical and transport properties of hydrothermal ZnO

We performed the studies of optical, photoelectric, and transport properties of a hydrothermal bulk n-type ZnO crystal by using the contactless optical techniques: photoluminescence, light-induced transient grating, and differential reflectivity. Optical studies revealed bound exciton and defect-related transitions between the donor states (at ∼60 meV and ∼240 meV below the conduction band) and the deep acceptor states (at 0.52 eV above the valence band). The acceptor state was ascribed to V{sub Zn}, and its thermal activation energy of 0.43 eV was determined. A low value of carrier diffusion coefficient (∼0.1 cm{sup 2}/s) at low excitations and temperatures up to 800 K was attributed to impact the recharged deep acceptors. Electron and hole mobilities of 140 and ∼80 cm{sup 2}/Vs, correspondently, were determined at room temperature. The decrease of carrier lifetime with excitation was ascribed to increasing rate of radiative recombination at low temperatures and nonradiative recombination above the room temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase-sensitive optomechanical amplifier for quantum noise reduction in laser interferometers

The sensitivity of future gravitational wave interferometers is expected to be limited throughout the detection band by quantum vacuum fluctuations, which can be reduced by applying quantum optics techniques such as squeezed vacuum injection. However, decoherence caused by optical losses in the readout chain will severely limit the effectiveness of such schemes. It was proposed that effect of losses in the final stage of detection can be mitigated by a phase-sensitive amplifier placed in between the output port of the interferometer and the photodetector. In this paper we propose to implement such amplification using an optomechanical device, study some of its practical limitations, and finally, discuss its applicability to next-generation gravitational-wave detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Timing measurement apparatus

Methods, devices and systems for providing accurate measurements of timing errors using optical techniques are described. An example timing measurement device includes an optical hybrid that receives two optical pulse trains and produces two or more phase shifted optical outputs. The timing measurement device further includes two or more optical filters that receive the outputs of the optical hybrid to produce multiple pulse signals with distinctive frequency bands. The device also includes one or more photodetectors and analog-to-digital converters to receive to produce electrical signals in the digital domain corresponding to the optical outputs of the hybrid. A timing error associated with the optical pulse trains can be determined using the electrical signals in digital domain based on a computed phase difference between a first frequency band signal and a second frequency band signal and a computed frequency difference between the first frequency band signal and the second frequency band.

DeVore, Peter Thomas Setsuda↗

Timing measurement apparatus

Methods, devices and systems for providing accurate measurements of timing errors using optical techniques are described. An example timing measurement device includes an optical hybrid that receives two optical pulse trains and produces two or more phase shifted optical outputs. The timing measurement device further includes two or more optical filters that receive the outputs of the optical hybrid to produce multiple pulse signals with distinctive frequency bands. The device also includes one or more photodetectors and analog-to-digital converters to receive to produce electrical signals in the digital domain corresponding to the optical outputs of the hybrid. A timing error associated with the optical pulse trains can be determined using the electrical signals in digital domain based on a computed phase difference between a first frequency band signal and a second frequency band signal and a computed frequency difference between the first frequency band signal and the second frequency band.

DeVore, Peter Thomas Setsuda↗

Quantification of UV-Visible and Laser Spectroscopic Techniques for Materials Accountability and Process Control

Ultraviolet–visible spectroscopy (UV–Visible) and time-resolved laser fluorescence spectroscopy (TRLFS) optical techniques can permit on-line analysis of actinide elements in a solvent extraction process in real time. These techniques have been used for measuring actinide speciation and concentration under laboratory conditions and are easily adaptable to multiple sampling geometries, such as dip probes, fiber-optic sample cells, and flow-through cell geometries. To fully exploit these techniques, researchers must determine the fundamental speciation of target actinides and the resulting influence on spectroscopic properties. Detection limits, process conditions, and speciation of key actinide components can be established and utilized in a range of areas, particularly those related to materials accountability and process control. Through this project, researchers will develop tools and spectroscopic techniques to evaluate solution extraction conditions and concentrations of U, Pu, and Cm in extraction processes, addressing areas of process control and materials accountability. The team will evaluate UV– Visible and TRLFS for use in solvent extraction-based separations. Ongoing research is examining efficacy of UV-Visible spectroscopy to evaluate uranium and plutonium speciation under conditions found in the UREX process and using TRLFS to evaluate Cm speciation and concentration in the TALSPEAK process. A uranyl and plutonium nitrate UV–Visible spectroscopy study met with success, which supports the utility and continued exploration of spectroscopic methods for evaluation of actinide concentrations and solution conditions for other aspects of the UREX+ solvent extraction scheme. This project will examine U and Pu absorbance in TRUEX and TALSPEAK, perform detailed examination of Cm in TRUEX and TALSPEAK, study U laser fluorescence, and apply project data to contactors. The team will also determine peak ratios as a function of solution concentrations for the UV-Visible spectroscopy studies. The use of TRLFS to examine Cm and U will provide data to evaluate lifetime, peak location, and peak ratios (mainly for U). The bases for the spectroscopic techniques have been investigated, providing fundamental evidence for the application’s utility.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development and Quantification of UV-Visible and Laser Spectroscopic Techniques for Materials Accountability and Process Control

Ultraviolet-Visible Spectroscopy (UV-Visible) and Time Resolved Laser Fluorescence Spectroscopy (TRLFS) optical techniques can permit on-line, real-time analysis of the actinide elements in a solvent extraction process. UV-Visible and TRLFS techniques have been used for measuring the speciation and concentration of the actinides under laboratory conditions. These methods are easily adaptable to multiple sampling geometries, such as dip probes, fiber-optic sample cells, and flow-through cell geometries. To fully exploit these techniques for GNEP applications, the fundamental speciation of the target actinides and the resulting influence on 3 spectroscopic properties must be determined. Through this effort detection limits, process conditions, and speciation of key actinide components can be establish and utilized in a range of areas of interest to GNEP, especially in areas related to materials accountability and process control.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Towards the development of a hybrid-integrated chip interferometer for online surface profile measurements

Non-destructive testing and online measurement of surface features are pressing demands in manufacturing. Thus optical techniques are gaining importance for characterization of complex engineering surfaces. Harnessing integrated optics for miniaturization of interferometry systems onto a silicon wafer and incorporating a compact optical probe would enable the development of a handheld sensor for embedded metrology applications. In this work, we present the progress in the development of a hybrid photonics based metrology sensor device for online surface profile measurements. The measurement principle along with test and measurement results of individual components has been presented. For non-contact measurement, a spectrally encoded lateral scanning probe based on the laser scanning microscopy has been developed to provide fast measurement with lateral resolution limited to the diffraction limit. The probe demonstrates a lateral resolution of ∼3.6 μm while high axial resolution (sub-nanometre) is inherently achieved by interferometry. Further the performance of the hybrid tuneable laser and the scanning probe was evaluated by measuring a standard step height sample of 100 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessing the future of diffuse optical imaging technologies for breast cancer management

Diffuse optical imaging (DOI) is a noninvasive optical technique that employs near-infrared (NIR) light to quantitatively characterize the optical properties of thick tissues. Although NIR methods were first applied to breast transillumination (also called diaphanography) nearly 80 years ago, quantitative DOI methods employing time- or frequency-domain photon migration technologies have only recently been used for breast imaging (i.e., since the mid-1990s). In this review, the state of the art in DOI for breast cancer is outlined and a multi-institutional Network for Translational Research in Optical Imaging (NTROI) is described, which has been formed by the National Cancer Institute to advance diffuse optical spectroscopy and imaging (DOSI) for the purpose of improving breast cancer detection and clinical management. DOSI employs broadband technology both in near-infrared spectral and temporal signal domains in order to separate absorption from scattering and quantify uptake of multiple molecular probes based on absorption or fluorescence contrast. Additional dimensionality in the data is provided by integrating and co-registering the functional information of DOSI with x-ray mammography and magnetic resonance imaging (MRI), which provide structural information or vascular flow information, respectively. Factors affecting DOSI performance, such as intrinsic and extrinsic contrast mechanisms, quantitation of biochemical components, image formation/visualization, and multimodality co-registration are under investigation in the ongoing research NTROI sites. One of the goals is to develop standardized DOSI platforms that can be used as stand-alone devices or in conjunction with MRI, mammography, or ultrasound. This broad-based, multidisciplinary effort is expected to provide new insight regarding the origins of breast disease and practical approaches for addressing several key challenges in breast cancer, including: Detecting disease in mammographically dense tissue, distinguishing between malignant and benign lesions, and understanding the impact of neoadjuvant chemotherapies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE SCUBA-2 COSMOLOGY LEGACY SURVEY: MULTIWAVELENGTH COUNTERPARTS TO 10{sup 3} SUBMILLIMETER GALAXIES IN THE UKIDSS-UDS FIELD

We present multiwavelength identifications for the counterparts of 1088 submillimeter sources detected at 850 μm in the SCUBA-2 Cosmology Legacy Survey study of the UKIRT Infrared Deep Sky Survey-Ultra-Deep Survey (UDS) field. By utilizing an Atacama Large Millimeter Array (ALMA) pilot study on a subset of our bright SCUBA-2 sample as a training set, along with the deep optical–near-infrared (OIR) data available in this field, we develop a novel technique, Optical–IR Triple Color (OIRTC), using z − K, K − [3.6], [3.6] − [4.5] colors to select the candidate submillimeter galaxy (SMG) counterparts. By combining radio identification and the OIRTC technique, we find counterpart candidates for 80% of the Class = 1 ≥ 4σ SCUBA-2 sample, defined as those that are covered by both radio and OIR imaging and the base sample for our scientific analyses. Based on the ALMA training set, we expect the accuracy of these identifications to be 82% ± 20%, with a completeness of 69% ± 16%, essentially as accurate as the traditional p-value technique but with higher completeness. We find that the fraction of SCUBA-2 sources having candidate counterparts is lower for fainter 850 μm sources, and we argue that for follow-up observations sensitive to SMGs with S{sub 850} ≳ 1 mJy across the whole ALMA beam, the fraction with multiple counterparts is likely to be >40% for SCUBA-2 sources at S{sub 850} ≳ 4 mJy. We find that the photometric redshift distribution for the SMGs is well fit by a lognormal distribution, with a median redshift of z = 2.3 ± 0.1. After accounting for the sources without any radio and/or OIRTC counterpart, we estimate the median redshift to be z = 2.6 ± 0.1 for SMGs with S{sub 850} > 1 mJy. We also use this new large sample to study the clustering of SMGs and the far-infrared properties of the unidentified submillimeter sources by stacking their Herschel SPIRE far-infrared emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Overcoming diffusion-related limitations in semiconductor defect imaging with phonon-plasmon-coupled mode Raman scattering

Carrier diffusion is of paramount importance in many semiconductor devices, such as solar cells, photodetectors, and power electronics. Structural defects prevent such devices from reaching their full performance potential. Although a large carrier diffusion length indicates high material quality, it also implies increased carrier depletion by an individual extended defect (for instance, a dislocation) and obscures the spatial resolution of neighboring defects using optical techniques. For commonly utilized photoluminescence (PL) imaging, the spatial resolution is dictated by the diffusion length rather than by the laser spot size, no matter the spot is at or below the diffraction limit. We show how Raman imaging of the LO phonon-plasmon-coupled mode can be used to recover the intrinsic spatial resolution of the optical system, and we demonstrate the effectiveness of the technique by imaging defects in GaAs with diffraction-limited optics, achieving a 10-fold improvement in resolution. Furthermore, by combining Raman and PL imaging, we can independently and simultaneously determine the spatial dependence of the electron density, hole density, radiative recombination rate, and non-radiative recombination rate near a dislocation-like defect, which has not been possible using other techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preparation and characterization of germanium oxysulfide glassy films for optics

Homogeneous amorphous films in the GeS{sub 2}-GeO{sub 2} system have been deposited by a rf sputtering technique. Optical characterizations have shown that the cut-off wavelength and the linear indices increase with an increase in the S/O ratio. Raman spectroscopy indicates the presence of new modes that can be assigned to intermediate germanium oxysulfide structural units. Photo-sensitivity of the oxysulfide films has been demonstrated for irradiation near the band-gap. Diffraction gratings inscribed using 488 nm exposure displayed a limited diffraction efficiency ({<=}3%) that weakens with a corresponding decrease in the glass S/O ratio.

36 MATERIALS SCIENCE↗

Linear-optics realization of channels for single-photon multimode qudits

We propose and theoretically study a method for the stochastic realization of arbitrary quantum channels on multimode single-photon qudits. In order for our method to be undemanding in its implementation, we restrict our analysis to linear-optical techniques, vacuum ancillary states, and nonadaptive schemes, but we allow for random switching between different optical networks. With our method it is possible to deterministically implement random-unitary channels and to stochastically implement general channels. We provide an expression for the optimal probability of success of our scheme and calculate this quantity for specific examples such as the qubit amplitude-damping channel. The success probability is shown to be related to the entanglement properties of the Choi-Jamiolkowski state isomorphic to the channel.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Strain Field Analysis in Electronic Components by ESPI: Bad Thermal Contact and Damage Evaluation

Designing electronic components and devices is a complex task that must include also considerations about thermo-mechanical behavior of the component itself. This aspect, in fact, can affect the reliability of the device as a consequence of the thermal stresses that are introduced in the component while it is working. Stress concentration can arise, in fact, due to different thermal expansion coefficients of the materials involved. Determining the thermo-mechanical response by numerically methods is not simple and not always possible so that experimental methods are preferable. In this paper, specifically, the electronic speckle pattern interferometry technique was adopted to measure full-field strain of the component during exercise. By using an optical technique it is possible to get information about the behavior of the component without being in contact with the component itself so that the dissipation coefficient is not altered. The system was able to detect gradients of deformation in the component itself connected to the different distribution of internal current in the component. Moreover, it was observed, that the presence of bad thermal contact between the package and the heat sink can be revealed because it results in a different thermos-mechanical behavior of the component. Finally, a critical defect was introduced in the component and it was observed the way the presence of damage affects the in-plane displacement of the component. Very huge differences were observed leading to the consideration that this kind of approach could be conveniently adopted also as a damage detection tool.

42 ENGINEERING↗