Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operation Reserve”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Impacts of Alternative Operations and Renewable Energy Deployment on Columbia River Hydropower

The Columbia River Treaty Tribes in the Pacific Northwest - the Nez Perce, Umatilla, Warm Springs, and Yakama - hold treaty-reserved fishing rights for the Columbia River, one of the world's most productive salmon rivers and a critical resource for these tribes. However, the tribes have expressed that current operating regimes of hydropower dams throughout the Columbia River Basin (CRB) do not fully account for tribal fishing rights and have negatively impacted fish populations. Four tribes acting together through the Columbia River Inter-Tribal Fish Commission (CRITFC)'s 2022 Energy Vision stated that current power system models often do not fully account for the many constraints faced by hydropower facilities in the CRB. As the deployment of variable renewable energy (VRE) like solar and wind continues to increase, power system flexibility will become increasingly important. As a result, there is a growing need to better understand the true capabilities of the hydropower generation fleet while accurately accounting for ecological constraints (Northwest Power and Conservation Council 2022). Understanding hydropower's role in a future grid with a higher share of VRE can inform water resources planning to address ecological needs. The goal of this study is to examine the impacts of alternative hydropower operation rules and weather variability on hydropower generation and grid operations in VRE and transmission infrastructure deployment scenarios. The study evaluates how hydropower scheduling practices can reduce ecological impacts to the region's salmon populations. More specifically, the study examines the impact of today's dam water release rules (called "adjusted base water rules" in this study) and new, ecologically informed water release rules (called "ecosystem water rules" in this study) on two VRE scenarios (current renewable energy levels and higher renewable energy levels) using six weather years for each scenario (2008-2013). CRITFC developed the ecosystem water rules, which capture a portion of the changes they recommend for CRB hydropower operations. These analyses use a water resource planning model (OASIS) and a production cost model (PLEXOS) to simulate CRB reservoir cascade and Western Interconnection power grid operation.

13 HYDRO ENERGY↗

Scheduler Modeling of Distributed Energy Resources for Providing Ancillary Services

Distribution energy resources (DERs) have been integral components of modern power systems, and their capability to provide grid services has been widely studied. To promote the deployment of these resources in providing grid services in real-world utility operations, this paper proposes a day-ahead scheduler model for a distribution system connected DER plant. A certain amount of generation capacity of this DER plant is reserved for frequency services, and some ancillary services for the distribution system-including peak load reduction, voltage regulation, and power factor control-are integrated into the model. The model is tested on a real-world distribution system. From the simulation results, the energy and reserve schedule of the solar photovoltaic (PV) unit and battery energy storage system (BESS) can be determined, and voltage and power factor are well maintained. Additionally, in order to demonstrate the specific characteristics of the co-located and hybrid operation modes for the PV and BESS, these two modes are analyzed both theoretically and through real-time simulation. Simulation results show that most of PV's variability is transferred to the net power in the co-located mode, whereas it is transferred to the BESS in the hybrid mode. This proposed scheduler model and the comparison of co-located and hybrid modes can provide practical guidance for the applications of DER plant in the real-world utility.

14 SOLAR ENERGY↗

Plasma catalytic non-oxidative methane conversion to hydrogen and value-added hydrocarbons on zeolite 13X

Non-thermal plasma has unfolded highly efficient, safe to operate novel routes for methane conversion to hydrogen. In this work, methane conversion is performed under atmospheric dielectric barrier discharge (DBD) plasma with and without 13X zeolite-based catalysts i.e., 13X, Ga/13X, Pd/13X, and Pd-Ga/13X. Experimental results indicate that the plasma catalytic process delivered almost twofold higher product yield than the plasma only route. The binary Pd-Ga catalyst possesses highest catalytic performance with about 40 % CH 4 conversion at an input flowrate of 5 cm 3 min -1 and 2W due to the formation of the Pd-Ga alloy, which acts as catalytic active centre for activating C–H bonds. Product yield can be tailored by the catalyst design where the bimetallic Pd-Ga/13X preferably favours the hydrocarbon formation while H 2 is the dominant product obtained over the Pd/13X. The cleavage of C–H bonds of methane molecule over the plasma only route is mainly governed by energetic electrons in the gaseous phase the catalyst activity, and plasma-catalyst synergism play a significant role in the plasma catalysis process. Further, the findings from this work provide significant insights into the methane activation for subsequent optimization of the methane conversion processes operated on floating production, storage, and offloading vessels (FPSOVs). Exploiting untapped offshore natural gas reserves, where conventional pipeline systems are less economical.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Occupancy schedule development and its effect on OpenStudio prototype college building model

College buildings have unique characteristics compared with school buildings. Therefore, defining the realistic occupancy schedule in a prototype college building has significant research opportunities. In this study, the actual operating schedules of each space type were collected and generated based on the class reservation schedule and compared with the previous reference schedule (primary/secondary school). Here, the schedules were analyzed for their effect on the OpenStudio prototype college building model. The findings highlight that the use of a typical school building schedule in a college building impairs the granularity of information. The analysis shows significant differences between the previous occupancy schedule and the updated occupancy schedule of the college building, leading to a considerable decrease in occupancy density. Furthermore, the effect of these occupancy pattern changes on the prototype building model is examined. The variations were observed in minimum ventilation requirements, the average mechanical ventilation rate, and energy consumption attributed to changes in occupancy density.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Valuation of Distributed Wind Turbines Providing Multiple Market Services

The role of wind turbines has traditionally been limited to providing energy capacity to the grid, but the availability of smart inverters and recent regulatory changes provide the technical and policy capability for wind turbines to also provide ancillary services. However, in contrast to the technical and policy aspects, the valuation of distributed wind turbines providing such services has not been thoroughly studied. This paper presents an optimal market-participation method for distributed wind turbines and valuates different strategies in California Independent System Operator’s balancing area. The services include energy capacity, regulation up and down, and reserves. An optimization problem is formulated to determine optimal power output for each service and demonstrated using historical data for one complete year. The revenues from multiple services are quantified, and a sensitivity analysis is performed to relate market prices with revenues. It is found that the optimal strategy generates 6% more revenue compared to the revenue from participating in the energy market only. Also, the reduced energy prices in future scenarios increase the relative importance of market participation in ancillary services.

Bhatti, Bilal Ahmad↗

Bill Savings vs. Backup Power: Evaluating operational tradeoffs for home solar+storage systems [Slides]

This study explores tradeoffs between the use of home solar+storage systems for backup power versus day-to-day utility bill savings. The study focuses specifically on the “reserve setting” available with most home battery storage systems, which allow the customer to maintain some minimum level of storage in reserve in case of an unforeseen power interruption. The more capacity that is held in reserve, the greater the customer’s ability to ride-through possible power interruptions, but less capacity is then available to manage utility bills on a day-to-day basis. This study evaluates this operational tradeoff across a diverse set of locations and residential electricity tariff structures, relying on Berkeley Lab’s PRESTO model to stochastically simulate power interruption events, and exploring a range of sensitivities, including variations in customer value of lost load (VoLL), interruption frequency, and other key drivers. The results show that, in most circumstances, the opportunity cost of holding storage capacity in reserve, in terms of foregone bill saving, tends to outweigh any gains in reliability value associated with mitigated power interruptions. This finding is robust across tariff structures and across most of the sensitivities considered, including those related to rate level, customer load level, and storage sizing. There are a limited set of circumstances where raising the reserve setting improves the overall customer value (comprised of bill savings plus reliability value). Specifically, that exception occurs when all of the following conditions apply: (a) the customer resides in a location with exceptionally poor reliability, (b) the customer has exceptionally high VoLL; (c) the customer is on a net billing rate or on a TOU rate that allows grid discharging but not grid charging; and (d), depending on the location, the price arbitrage differential on that rate is relatively small. In all other circumstances analyzed, total customer value declines with reserve level.

14 SOLAR ENERGY↗

Bi-Level Linear Programming Model for Automatic Load Shedding: A Distributed Wide-Area Measurement System-based Solution

Load shedding is currently implemented as a two-step based approach. In the first step, manual load shedding is taken place, were system operators, using estimates, inform distribution utilities of predicted stressful conditions. Information provided include the potential use of energy reserves, as well as load shedding amount. In a second step, automatic load shedding is done. The latter is realized using protection relays. While considering frequency variation, pre-defined values of load to be shed and correspondent number of stages for such to be realized are transformed into relay settings. Under-frequency protection relays use only local measurements towards decision making, thus operate in a decentralized architecture. Decision making is done in milliseconds plus breaker time. While this approach has provided much system reliability, considering the new smart grid paradigm, where system dynamics are much faster due to increasing renewable resources penetration, in some operating conditions it will generate sub-optimal solutions, such as islanding. Phasor measurement units provide a source of information which can be useful for this problem. Centralized architecture-based solutions for automatic load shedding, as present in the state-of-the-art, require though total processing times which are not acceptable for real-life implementation. In this work, considering the above, a bi-level linear programming model is presented. The model is implemented considering a distributed architecture while leveraging phasor measurement units data. The upper-level model estimates the current system state. Results of this model are embedded in a lower-level model, which decision variables are the location and load value to be shed. Easy-to-implement model, built-on the classic weighted least squares solution, highlight potential aspects towards real-life applications.

Bretas, Arturo Suman↗

Evaluating the Impact of Managed EV Charging for Reliable Operation of Bulk Power Systems with High Non-Dispatchable Generation

The growth of electric vehicles (EVs) and variable-generation (VG) sources introduces new challenges for power-system operations. This study introduces a modeling framework and evaluates five EV charging strategies under projected 2040 grid conditions in the Evergy service territory with high non-dispatchable generation. Using realistic EV behavior and generation models, their impacts on system peak demand, ramp rate, and reserve capacity are evaluated. Results show that only the peak-avoidance strategy effectively reduces system peak demand, while decentralized strategies-particularly cost based dynamic charging-can exacerbate peaks due to synchronized user behavior. However, ramp-rate minimization strategy significantly reduce the stress on dispatchable generation achieving the lowest maximum absolute ramp rate (MARR) (56.81 MW) and lowest reserve requirement (2.39 GW). In contrast, unmanaged and TOU random strategies increase the stress on dispatchable generation sources with increased MARR and reserve requirements. These findings highlight the importance of coordinated, system-aware managed charging strategies to ensure reliable and affordable grid operation in the presence of EVs and VG sources.

14 - SOLAR ENERGY↗

Unlocking Dysprosium Constraints for China’s 1.5 °C Climate Target

Some key low-carbon technologies, ranging from wind turbines to electric vehicles, are underpinned by the strong rare-earth-based permanent magnets of the Nd, Pr (Dy)–Fe–Nb type (NdFeB). These NdFeB magnets, which are sensitive to demagnetization with temperature elevation (the Curie point), require the addition of variable amounts of dysprosium (Dy), where an elevation of the Curie point is needed to meet operational conditions. Given that China is the world’s largest REE supplier with abundant REE reserves, the impact of an ambitious 1.5 °C climate target on China’s Dy supply chain has sparked widespread concern. Here, we explore future trends and innovation strategies associated with the linkage between Dy and NdFeBs under various climate scenarios in China. We find China alone is expected to exhaust the global present Dy reserve within the next 2–3 decades to facilitate the 1.5 °C climate target. By implementing global available innovation strategies, such as material substitution, reduction, and recycling, it is possible to avoid 48%–68% of China’s cumulative demand for Dy. Nevertheless, ongoing efforts in REE exploration and production are still required to meet China’s growing Dy demand, which will face competition from the United States, European Union, and other countries with ambitious climate targets. Here our analysis urges China and those nations to form wider cooperation in REE supply chains as well as in NdFeB innovation for the realization of a global climate-safe future.

54 ENVIRONMENTAL SCIENCES↗

Hydropower Role in a Power Grid with a High Proportion of Variable Renewables

The importance of hydropower increases as the power grid evolves with the higher variable renewable contribution. As conventional thermal power plants are retired, the importance of hydropower contribution increases to balance the variability of solar and wind generation. However, reservoir water resources are constrained by multiple constraints, and variability of water inflow to the reservoirs creates limitations to dam water releases for power grid needs. Coordination of multiple tools, including water resources modeling, ecological modeling, and technical and economic power grid modeling, informs dam water releases. Better representation of ecological constraints and other water use details in the suit of power grid models are required to identify the hydropower flexibility to provide multiple power grid services. Impacts of water planning and hydropower operation changes to a power grid are better understood by production cost model simulations with technical and economic data, including unserved energy, reserve failures, transmission congestion to serve load, and local marginal price increases. Similarly, PCM simulation of current and future projected power grid information, including LMP, and carbon emission rates, informs short-term water release plans and long-term investments for power plant upgrades for technical and ecological needs. Hydropower operations of several case studies are simulated to understand operation patterns, revenue, water release decisions in multiple time scales (month, day, minutes), hydropower contracts scheduling, and water variability impacts.

environmental↗

Mixed nitrate and metal contamination influences operational speciation of toxic and essential elements

Environmental contamination constrains microbial communities impacting diversity and total metabolic activity. The former S-3 Ponds contamination site at Oak Ridge Reservation (ORR), TN, has elevated concentrations of nitric acid and multiple metals from decades of processing nuclear material. To determine the nature of the metal contamination in the sediment, a three-step sequential chemical extraction (BCR) was performed on sediment segments from a core located upgradient (EB271, non-contaminated) and one downgradient (EB106, contaminated) of the S-3 Ponds. The resulting exchangeable, reducing, and oxidizing fractions were analyzed for 18 different elements. Comparison of the two cores revealed changes in operational speciation for several elements caused by the contamination. Those present from the S-3 Ponds, including Al, U, Co, Cu, Ni, and Cd, were not only elevated in concentration in the EB106 core but were also operationally more available with increased mobility in the acidic environment. Other elements, including Mg, Ca, P, V, As, and Mo, were less operationally available in EB106 having decreased concentrations in the exchangeable fraction. Here, the bioavailability of essential macro nutrients Mg, Ca, and P from the two types of sediment was determined using three metal-tolerant bacteria previously isolated from ORR. Mg and Ca were available from both sediments for all three strains; however, P was not bioavailable from either sediment for any strain. The decreased operational speciation of P in contaminated ORR sediment may increase the dependence of the microbial community on other pools of P or select for microorganisms with increased P scavenging capabilities. Hence, the microbial community at the former S-3 Ponds contamination site may be constrained not only by increased toxic metal concentrations but also by the availability of essential elements, including P.

54 ENVIRONMENTAL SCIENCES↗

Life‐Cycle Assessment Considerations for Batteries and Battery Materials

Abstract Rechargeable batteries are necessary for the decarbonization of the energy systems, but life‐cycle environmental impact assessments have not achieved consensus on the environmental impacts of producing these batteries. Nonetheless, life cycle assessment (LCA) is a powerful tool to inform the development of better‐performing batteries with reduced environmental burden. This review explores common practices in lithium‐ion battery LCAs and makes recommendations for how future studies can be more interpretable, representative, and impactful. First, LCAs should focus analyses of resource depletion on long‐term trends toward more energy and resource‐intensive material extraction and processing rather than treating known reserves as a fixed quantity being depleted. Second, future studies should account for extraction and processing operations that deviate from industry best‐practices and may be responsible for an outsized share of sector‐wide impacts, such as artisanal cobalt mining. Third, LCAs should explore at least 2–3 battery manufacturing facility scales to capture size‐ and throughput‐dependent impacts such as dry room conditioning and solvent recovery. Finally, future LCAs must transition away from kg of battery mass as a functional unit and instead make use of kWh of storage capacity and kWh of lifetime energy throughput.

25 ENERGY STORAGE↗

Optimized Dispatch of Distributed Energy Resources for Resiliency and Power Quality Improvements at the Grid-Edge

Distributed Energy Resources (DERs) installed on low-voltage distribution systems, both utility-owned and nonutility owned may be employed to make improvements to system resiliency and power quality, in addition to simply serving load demand. By selectively dispatching active and reactive power from these existing DERs, improvements in voltage profiles and service availability during adverse events may be achieved. Further benefits can be gained by optimally choosing which DERs to dispatch power from, and the distribution of power from those DERs. For a given operating condition, using Linear Programming methods, optimal power dispatch values for individual DERs can be determined, while considering variables such as voltage gains, losses in the lines and the DERs, and DER reserve capacities. One such optimization technique is developed in this paper, and results from a real-time simulation study on a modified IEEE 13-bus distribution system with three DERs, are being presented. The operation of the optimized DER selection and dispatch algorithm is shown during normal operation of the transmission system when the DERs operate in grid-connected mode. Similar analyses can drive decision making during transmission system failure when the DERs operate in grid-forming or islanded mode.

Chowdhury, Prithwiraj Roy↗

Multi-layered Energy Management Framework for Extreme Fast Charging Stations Considering Demand Charges, Battery Degradation, and Forecast Uncertainties

To achieve a cost-effective and expeditious charging experience for extreme fast charging station (XFCS) owners and electric vehicle (EV) users, the optimal operation of XFCS is crucial. It is however challenging to simultaneously manage the profit from energy arbitrage, the cost of demand charges, and the degradation of a battery energy storage system (BESS) under uncertainties. This paper, therefore, proposes a multi-layered multi-time scale energy flow management framework for an XFCS by considering long- and short-term forecast uncertainties, monthly demand charges reduction, and BESS life degradation. In the proposed approach, an upper scheduling layer (USL) ensures the overall operation economy and yields optimal scheduling of the energy resources on a rolling horizon basis, thereby considering the long-term forecast errors. A lower dispatch layer (LDL) takes the short-term forecast errors into account during the real-time operation of the XFCS. Per the latest research, monthly demand charges can be as high as 90% of the total monthly bills for EV fast charging stations; to this end, this paper takes the first attempt at the reduction of demand charges cost by considering the trade-off between the energy cost and monthly demand charges. Contrasting literature, this work allocates an energy reserve in the BESS stored energy to deal with the impact of short-term forecast errors on the optimized real-time operation of the XFCS. Moreover, degradation modeling considers the trade-off between short-term benefits and long-term BESS life degradation. As a result, case studies and a comparative analysis prove the efficacy of the proposed framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Analysis of PNM's Renewable Reserve Requirements to Meet New Mexico's Decarbonization Goals

Over the next three years, the Public Service Company of New Mexico (PNM) plans to increase utility-scale solar photovoltaic (PV) capacity from today’s roughly 330MW to about 1600MW. This massive increase in variable generation—from about 15% to 75% of peak load—will require changes in how PNM operates their system. We characterize the 5 and 30-minute solar and wind forecast errors that the system is likely to experience in order to determine the level of reserves needed to counteract such events. Our focus in this study is on negative forecast error (in other words, shortfalls relative to forecast) – whereas excess variable generation can be curtailed if needed, a shortfall must be compensated for to avoid loss of load. Calculating forecast error requires the use of the same forecasting methods that PNM uses or a reasonable approximation thereof. For wind, we use a persistence forecast on actual 5-minute 2019 wind output data (scaled up to reflect the amount of wind capacity planned for 2025). For solar, we use a formula incorporating the clear sky index (CSI) for the forecast. As the solar on the grid now is a small fraction of what is planned for 2025, we generated 5-minute solar data using 2019 weather inputs. We find that to handle 99.9% of the 5-minute negative forecast errors, a maximum of 275MW of variable generation reserve during daylight hours, and a maximum of 75MW during non-daylight hours, should be sufficient. Note that this variable generation reserve is an additional reserve category that specifies reserves over and above what are currently carried for contingency reserve. This would require a significant increase in reserve relative to what PNM currently carries or can call upon from other utilities per reserve sharing agreements. This variable generation reserve specification may overestimate the actual level needed to deal with PNM’s planned variable generation in 2025. The forecasting methodologies used in this study likely underperform PNM’s forecasting – and better forecasting allows for less reserve. To obtain more precise estimates, it is necessary to consider load and use the same forecasting inputs and methods used by PNM.

14 SOLAR ENERGY↗

The COVID-19 High-Performance Computing Consortium

In March of 2020, recognizing the potential of High Performance Computing (HPC) to accelerate understanding and the pace of scientific discovery in the fight to stop COVID-19, the HPC community assembled the largest collection of worldwide HPC resources to enable COVID-19 researchers worldwide to advance their critical efforts. Amazingly, the COVID-19 HPC Consortium was formed within one week through the joint effort of the Office of Science and Technology Policy (OSTP), the U.S. Department of Energy (DOE), the National Science Foundation (NSF), and IBM to create a unique public–private partnership between government, industry, and academic leaders. This article is the Consortium's story–how the Consortium was created, its founding members, what it provides, how it works, and its accomplishments. We will reflect on the lessons learned from the creation and operation of the Consortium and describe how the features of the Consortium could be sustained as a National Strategic Computing Reserve to ensure the nation is prepared for future crises.

97 MATHEMATICS AND COMPUTING↗

Evaluating Movement Patterns of the Rattlesnake Hills Elk Herd on Hanford for Calendar Years 2019-2024

Biologists first documented elk on the Hanford Site in 1972; since then, the elk herd known as the Rattlesnake Hills Elk Herd (RHEH) has grown substantially (PNNL-13331, Population Characteristics and Seasonal Movement Patterns of the Rattlesnake Hills Elk Herd: Status Report 2000). Through the 1990s, the core range of the RHEH was focused on the portion of the Hanford Reach National Monument known as the Fitzner-Eberhardt Arid Lands Ecology (ALE) Reserve. More recently, larger numbers of elk have been occupying the U.S. Department of Energy (DOE), Hanford Field Office (HFO), formerly the DOE, Richland Operations Office managed portion- of the Hanford Site, known as central Hanford (Figure 1-1). This began with bachelor groups of bulls occupying the site intermittently, and the herd has grown to resident herds, including bulls, cows, and calves. The Washington Department of Fish and Wildlife (WDFW) established a target herd size for the RHEH of less than 350 animals to minimize damages on adjacent private agricultural lands (Washington State Elk Herd Plan–Yakima Elk Herd [WDFW 2002]). Attempts to control the RHEH population through hunting on private lands and a relocation effort during 2000 have failed to limit growth of the population toward the WDFW target, and the herd exceeds 1,600 according to recent counts (PNNL-13331; DOE/RL- 2023-20, Hanford Annual Site Environmental Report for Calendar Year 2022). Although elk are present on central Hanford year-round, they continue to move between areas offsite, the ALE Reserve, and central Hanford throughout the year, and it is these movements that result in many of the elk-vehicle collisions (EVC) that occur along Hanford Site roads and on the Washington State highways bordering the site. In addition, changes in management strategies on the ALE Reserve, including recent and potential future tribal elk hunts, may alter herd behavior and result in additional animals transiting onto and off central Hanford.

54 ENVIRONMENTAL SCIENCES↗

Use Probabilistic Forecasts in Reliable and Economic Electricity Market Scheduling and Operations

The value of probabilistic forecasts in electricity market operations is being increasingly recognized lately, however, the use is still limited. This study demonstrates two cases of using probabilistic forecasts in scheduling and operations of the California electricity market. We first develop a data-driven method to give weather-informed estimates of ramping reserves based on short-term probabilistic solar irradiance forecasts. By using forecasts across multiple sites, our proposed method presents advantages over the real-world baseline in terms of system reliability and economics. Our second case uses probabilistic hydro power forecasts in the scheduling of a hydro power plant under economic and environmental constraints. By optimizing the bids into both the day-ahead and real-time markets, our results demonstrate considerable economic benefits.

13 HYDRO ENERGY↗