Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupancy Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Towards Measurement of the Time-resolved Heat Release of Protein Conformation Dynamics

We present a way to observe time-resolved heat release using a laminar flow diffusional mixer coupled with a highly sensitive infrared camera which measures the temperature change of the solvent. There are significant benefits to the use of laminar flow mixers for time-resolved calorimetry: (1) The thermal signal can be made position and time- stationary to allow for signal integration; (2) Extremely small volumes (nl/s) of sample are required for a measurement; (3) The same mixing environment can be observed spectroscopically to obtain state occupation information; (4) The mixer allows one to do out of equilibrium dynamic studies. The hope is that these measurements will allow us probe the non-equilibrium thermodynamics as a protein moves along a free energy trajectory from one state to another.

Puchalla, Jason↗

Regional difference and related cooling electricity savings of air pollutant affected natural ventilation in commercial buildings across the US

Maintaining indoor air pollutants under acceptable levels is significant to protect occupants from exposure to excessive air pollutants in natural ventilation. In this paper, using the representative air pollutant concentration data, we present the natural ventilation usability with associated cooling energy saving potentials in different location settings (urban and city center, suburban and rural) of the US under the influence of local weather conditions and major outdoor air pollutants, i.e. PM2.5, PM10 and ozone. It is found that the impacts of air pollutants on natural ventilation are usually higher in urban/suburban areas than rural areas (up to 25% difference) with the PM2.5 being the most significant outdoor air pollutant affecting natural ventilation usage. Furthermore, ozone could become increasingly influential on natural ventilation as moving from urban to suburban/rural areas. As to the cooling energy saving considering the impacts of outdoor air pollutants, natural ventilation is estimated to save approximately 10%–40% cooling energy (800–2600 kWh per small commercial building) annually in different location settings of investigated areas across the US. The following economic analysis demonstrates that these electricity savings lead to approximately 80–540 dollars annual savings of building operation cost per building. If the time of use rate is adopted, these cost savings could further increase by approximately 20% (Los Angeles) to more than 50% (Albuquerque) depending on different rate structures, which further demonstrates the potential of adopting natural ventilation as a sustainability measurement with benefits for building owners without compromising occupants health.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fault Detection via Occupation Kernel Principal Component Analysis

Reliable operation of automatic systems is heavily dependent on the ability to detect faults in the underlying dynamics. While traditional model-based methods have been widely used for fault detection, data-driven approaches have garnered increasing attention due to their ease of deployment and minimal need for expert knowledge. In this letter, we present a novel principal component analysis (PCA) method that uses occupation kernels. Occupation kernels result in feature maps that are tailored to the measured data, have inherent noise-robustness due to the use of integration, and can utilize irregularly sampled system trajectories of variable lengths for PCA. The occupation kernel PCA method is used to develop a reconstruction error approach to fault detection and its efficacy is validated using numerical simulations.

42 ENGINEERING↗

Spin-orbit-splitting-driven nonlinear Hall effect in NbIrTe 4

The Berry curvature dipole (BCD) serves as a one of the fundamental contributors to emergence of the nonlinear Hall effect (NLHE). Despite intense interest due to its potential for new technologies reaching beyond the quantum efficiency limit, the interplay between BCD and NLHE has been barely understood yet in the absence of a systematic study on the electronic band structure. Here, we report NLHE realized in NbIrTe 4 that persists above room temperature coupled with a sign change in the Hall conductivity at 150 K. First-principles calculations combined with angle-resolved photoemission spectroscopy (ARPES) measurements show that BCD tuned by the partial occupancy of spin-orbit split bands via temperature is responsible for the temperature-dependent NLHE. Our findings highlight the correlation between BCD and the electronic band structure, providing a viable route to create and engineer the non-trivial Hall effect by tuning the geometric properties of quasiparticles in transition-metal chalcogen compounds.

36 MATERIALS SCIENCE↗

Vacancy-tuned magnetism in LaMn x Sb 2

The layered AMP 2 (A = alkali-earth or rare-earth atom, M = transition metal, P = Sb, Bi) compounds are widely studied for their rich magnetism and electronic structure topology. We provide a detailed characterization of the magnetic and transport properties of LaMn x Sb 2 , an understudied member of the AMP 2 family. LaMn x Sb 2 forms with intrinsic Mn vacancies, and we demonstrate that by varying the starting ratio of La, Mn, and Sb, we can synthetically control the Mn occupancy and produce single crystals with x = 0.74 – 0.97. Magnetization and transport measurements indicate LaMn x Sb 2 has a rich temperature-composition (T–x) magnetic phase diagram with physical properties strongly influenced by the Mn occupancy. LaMn x Sb 2 orders antiferromagnetically at T 1 = 130–180 K, where T 1 increases with x. Below T 1 , the T–x phase diagram is complicated. At high x, there is a second transition T 2 that decreases in temperature as x is lowered, vanishing below x ≤ 0.85. A third, first-order, transition T 3 is detected at x ≈ 0.92, and the transition temperature increases as x is lowered, crossing above T 2 near x ≈ 0.9. On moving below x < 0.79, here we find the crystal structure changes from the P 4/nmm arrangement to an I$\bar{4}$2m structure with partially ordered Mn vacancies. The change in crystal structure results in the sudden appearance of two new low-temperature phases and a crossover between regimes of negative and positive magnetoresistance when x ≤ 0.78. Finally, we provide powder neutron diffraction for x = 0.93, and find that the high-x compositions first adopt a G-type antiferromagnetic structure with the Mn moments aligned within the ab plane, which is followed upon further cooling by a second transition to a different, noncollinear structure where the moments are rotated within the basal plane. Our results demonstrate that LaMn x Sb 2 is a highly tunable material with six unique magnetically ordered phases, depending on T and x.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Archival records housed at USTUR support radium dial worker dosimetry

The American radium dial worker (RDW) cohort of over 3200 persons is being revisited as part of the Million Person Study (MPS) to include a modern approach to RDW dosimetry. An exceptional source of data and contextualization in this project is an extensive collection of electronic records (digitized from existing microfilm and microfiche) housed at the United States Transuranium and Uranium Registries (USTUR). Although the type, extent, and quality (e.g. legibility) of record(s) varies between individuals, the remarkable occupational, medical and demographic data include in vivo radiation measurements (e.g. radon breath, whole body counts), autopsy results, medical records (including copies of radiographs), interviews over the years, and correspondence. Of particular dosimetric interest are the details of radiation measurements. For example, there are some instances where hand-written and transcribed values are both available, along with notes providing context for why a particular measurement in a series of measurements was chosen to assign an intake, or if there were concerns about a particular measurement. Born prior to 1935, RDW have nearly all passed away. Thus, the updated dosimetry, especially for the skeletal tissues, will allow the correlation of lifetime cumulative dose with radiation risk. Here we review typical information available in this collection of historical records and highlight some interesting finds. Additionally, we discuss the relevance to current and ongoing work related to updating the dosimetry of the RDW in the MPS, including providing an example of the usefulness of information contained in these records. The RDW cohort provides a unique historical perspective on occupational exposure to radium, making it a valuable dataset for understanding long-term health effects and improving current radiation protection standards.

Million Person Study↗

Data-driven modeling of dynamic occupant thermostat override behavior for demand response applications

Buildings consume nearly 40% of global energy and produce similar emissions. Whiletechnological advances address efficiency, occupant behavior causes energy use variations up to 300% between identical buildings. This gap between predicted and actual building performance impacts building design, operations, and grid demand management programs. Through analyses of smart thermostat data from 1,400 single-occupant homes, the researchdemonstrates that occupants respond to 8°F thermostat setpoint changes within a median of 15 minutes, while 2°F changes trigger responses within a median of 30 minutes. This highlights an understudied temporal relationship between thermostat setbacks and response time of occupant behaviors. Models of such behavior dynamics are required to incorporate occupant impacts into building performance simulation. A key contribution of this dissertation is the Thermal Frustration Theory (TFT), which positsthat thermal discomfort driven behaviors are caused by the time-accumulation of discomfort, not simply a temperature deviation threshold or a delay from an initiating event. Using a dataset of 634 thermostats, each with 25+ manual setpoint changes, a comparative analysis of TFT and comfort zone and a delayed response theories demonstrated that personalized TFT models better predict when manual setpoint change occur. This was measured by the area under the curve statistical measure (AUC); all three models perform similarly by a Matthews Correlation Coefficient measure. Higher AUC performance is especially important for modeling occupant behavior in demand response programs where false negatives of rare occupant interactions could adversely affect grid stability. EnergyPlus based simulations were conducted with TFT-derived occupant models, demonstrating the ability to identify parameters of known TFT models from only data observable with smart thermostats, even under the presence of noise from routine overrides. Overall, the dissertation highlights that thermostat interactions are neither static,instantaneous, nor driven solely by the environment. Instead, temporal accumulation of discomfort and routine-based behavior play important roles. The methodology and results offer a pathway towards more accurate modeling of human-building interactions for policy assessment, building design, and demand response programs.

Sharma, Kunind [Northeastern University] (ORCID:00↗

Analysis of strategies to meet ASHRAE S241 infectious aerosol control targets by space type and region using EnergyPlus™ simulations

Professional organizations, such as ASHRAE, have recently proposed new voluntary standards for controlling infectious aerosols. Specifically, ASHRAE Standard 241 (S241) defines equivalent clean air targets for a range of space types that can be met through combinations of mitigation measures. This paper seeks to inform the selection of measures by space type and climate zone through building simulations that quantify the impacts of increased outdoor air ventilation; increasing filtration and/or adding germicidal ultraviolet (GUV) in the central heating, ventilation, and air-conditioning (HVAC) systems; or using portable air cleaners (PACs), upper room GUV, or whole room GUV approaches to increase equivalent clean air delivery. The measures are assessed individually and in practical combinations for their ability to meet S241 in four space types (offices, classrooms, dining areas, and healthcare waiting rooms) using prototype buildings modeled using EnergyPlus. The mitigation measures are compared holistically against baseline building operations using metrics for equivalent clean air, energy, and comfort. The results in this study show that single measures can meet S241 for offices with minimal impacts on energy and comfort, while either upper room GUV systems or combinations of measures such as MERV 13 HVAC filtration with PACs are needed to meet S241 for classrooms. The dining area and healthcare waiting room targets cannot be met in this study when assuming design occupancy and MS2 as the challenge agent, even when combining multiple measures together. This paper provides valuable considerations when designing measures to meet S241 for a range of spaces and scenarios.

GUV↗

A Review of Existing Test Methods for Occupancy Sensors

One of the key new features of connected lighting systems (CLS) is their ability to collect data from various types of integral sensors and share that data with other lighting or building systems. Occupancy and vacancy sensors have been widely adopted as an energy-saving strategy in buildings, yet published test methods for reproducibly characterizing their performance remain few and limited in their sophistication. As a result, it has been difficult to predict the performance of such sensors in a specific application, and in practice, they frequently do not meet energy-savings expectations. Occupants at times remove or otherwise bypass occupancy sensors that hinder their work or otherwise do not perform as expected, thereby compromising the sensors’ potential to reduce energy consumption. Poor performance can result from multiple causes – ranging from fundamental limitations of the sensor technology, to misconfiguration, to poor placement in the room or space. Innovative occupancy sensors, some of them combining multiple sensing technologies (i.e., multimodal), have come on the market over the years, with claims of improved performance compared to their predecessors. However, in practice, their performance has neither differed enough from the performance of previous products to necessitate a test method that facilitated comparison between them, nor has it led to high deployment or high user satisfaction in human-occupied spaces with persistent presence. While the performance of both common and novel occupancy sensors has been the subject of many published research articles, the test methods that have been employed for them typically have been loosely described and have incorporated custom equipment or techniques that render them difficult to reproduce, or have been limited in their ability to fairly characterize devices that utilize varying sensor technology. The lack of a fully described, technology-agnostic test method that yields reproducible results across different implementations has been a barrier to the commercial success of new occupancy-sensor products, as users and specifiers who have been disappointed with previous products are often unwilling to take a chance with new ones. Motivated by a desire to fairly characterize new technologies that continue to enter the market and claim not only improved occupancy detection but, in some cases, additional capabilities (e.g., the ability to measure traffic or discern between different object types), this report presents the results of a literature review of recently published fully described test methods for characterizing occupancy-sensor performance, as well as research articles containing ad-hoc test methods. The review also identifies and consolidates test conditions for characterizing sensor performance in indoor spaces and identifies apparent test method gaps that need to be filled in order to evaluate emerging technologies and products. The identified test-method conditions are intended to enable the development of a future technology-agnostic test method that facilitates occupancy-sensor performance characterization more-accurately representing performance in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of airborne RF measurements from U.S.A. urban areas

The paper presents in-situ, airborne survey radio-frequency measurements, which were made over the 400-1000 MHz range in May 1977 during the ASSESS-II Space Shuttle/Spacelab simulation aircraft flights. Measurements were made from altitudes of 10,000 to 33,000 feet with a downward-directed 70 deg wide, half-power beamwidth receiving antenna pattern. Channel occupancy percentages are given within a 50 MHz spectrum width, and continuous spectrum-scan measurements are presented for selected locations on the USA West Coast, showing the channel occupancy environment within the 806-890 MHz mobile-service band.

Taylor, R. E.↗

Occupancy of the radio frequency spectrum in the 16-23 MHz band

Measurement results are presented for actual utilization of the short wave frequency band, obtained by continuous registration of the number of radio stations in the 16-23 MHz band over an annual cycle (1965). It is shown that there is a relation between the number of radio stations and the variations of MUF-F2. During years of minimum solar activity and at night, segments free of radio stations operating by normal reflection, can be selected in the 18-23-MHz band for ionospheric-scattering links.

Ashkaliyev, Y. F.↗

Occupational Medical Trends in the 70's from Industrial View

Industrial health measures to ensure worker productivity constitute physical examinations as well as environmental control systems. Considered are automatic record keeping facilities for case histories, preventive medical and mental counselling, development of safety standards, and health insurance and disability benefit plans. Cooperation of industry health programs with community health aspects is required to eliminate the loss of manpower capability through alcoholism or mental disease.

Williamson, S. M.↗

Pu 5f Occupation in Plutonium Dioxide

Herein an actinide N 4,5 branching ratio analysis of PuO 2 and UO 2 has been performed, including measurements with a scanning transmission electron microscope at the Advanced Light Source. It is shown that the 5f occupation of the Pu in plutonium dioxide is n = 5. This is contrary to recent results from another technique.

36 MATERIALS SCIENCE↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

Influence of overhead HVAC and aerosol control strategies on coarse mode particle dispersion and exposure in a full-scale room experiment

Coarse mode respiratory aerosols can carry viral loads over long distances and have very different dynamics than submicron particles, but experimental studies under realistic conditions remain limited. Here, to study the differential impacts on exposure under different mixing conditions, we co-released 7–10 µm particles and carbon dioxide (CO 2 )—which served as an indicator of gas and submicron particle dynamics—in a 158 m 3 room at LBNL's FLEXLAB facility with an overhead heating, ventilation, and air conditioning (HVAC) system. The room was arranged as a distanced meeting then a classroom with eight heated manikins and a researcher. Spatial variability was measured using 16 particle counters and 22–26 CO 2 sensors throughout the space. Conditions included: HVAC off or supply air at 1000-1060 m 3 h -1 at neutral, cooling, or heating temperatures; with and without 20% outdoor air; and added HVAC filtration, portable air cleaners (PACs), or a physical barrier between the speaker and occupants. We found that good mixing via neutral or cooling supply air or use of PACs under heating lowered coarse particle exposure at some locations, but increased exposure for one-quarter to two-thirds of manikins compared to poor mixing under heating. A physical barrier reduced direct transfer of coarse particles during heating, but less during cooling. High spatial variability shows that a single measurement cannot represent occupant exposure. Instantaneous air mixing assumptions overstate the effectiveness of ventilation, HVAC filtration, and upper-room germicidal ultraviolet disinfection for coarse particles, as relatively few particles reach the return grille or upper room under most conditions.

Air mixing↗

A Review of Existing Test Methods for Occupancy Sensors

One of the key new features of connected lighting systems (CLS) is their ability to collect data from various types of integral sensors and share that data with other lighting or building systems. Occupancy and vacancy sensors have been widely adopted as an energy-saving strategy in buildings, yet published test methods for reproducibly characterizing their performance remain few and limited in their sophistication. As a result, it has been difficult to predict their performance in a specific application, and in practice, they frequently do not meet energy-savings expectations. Occupants at times remove or otherwise bypass occupancy sensors that hinder their work or otherwise do not perform as expected, thereby compromising the sensors’ potential to reduce energy consumption. Poor performance can result from multiple causes – ranging from fundamental limitations of the sensor technology, to misconfiguration, to poor placement in the room or space. Innovative occupancy sensors, some of them combining multiple sensing technologies, have come on the market over the years, with claims of improved performance compared to their predecessors; yet in practice, their performance has led to neither high deployment nor high user satisfaction in any significant application, nor has it differed enough from the performance of previous products to necessitate a test method that facilitated comparison between them. While the performance of both common and novel occupancy sensors has been the subject of many published research articles, the test methods that have been employed for them have typically been loosely described and incorporated custom equipment or techniques that render them difficult to reproduce, or have been limited in their ability to fairly characterize devices that utilize varying sensor technology. The lack of a well-described, technology-agnostic test method that yields reproducible results across different implementations has been a barrier to the commercial success of new occupancy sensor products, as users and specifiers who have been disappointed with previous products are often unwilling to take a chance with new ones. Motivated by a desire to fairly characterize new technologies that continue to enter the market and claim not only improved occupancy detection but, in some cases, also additional capabilities (e.g., the ability to measure traffic or discern between different object types), this report presents the results of a literature review of recent published, well-described test methods for characterizing occupancy sensor performance, as well as research articles containing ad-hoc test methods. The review also identifies and consolidates the best techniques for characterizing sensor performance in indoor spaces and identifies test method gaps that need to be filled in order to evaluate emerging technologies and products.

47 OTHER INSTRUMENTATION↗

Application of reference-free natural background–oriented schlieren photography for visualizing leakage sites in building walls

Air leakage in buildings can cause health and comfort concerns for occupants and can contribute to mold growth on building materials, or in extreme conditions, rot of building materials. Unwanted air leakage through the building envelope also contributes to approximately 4 quadrillion Btu (1172 TWh) of energy consumption per year in the building sector in the United States. Locating and sealing leakage sites can improve the energy efficiency, comfort, air quality, and moisture durability of the building stock. Typical methods of finding leakage sites, such as infrared imaging and smoke tracing, rely on concurrent blower door operation, which can also measure the total leakage rate of the building. Smoke tracing can be disruptive to occupants, and infrared imaging and smoke tracing cannot measure the contribution of individual leaks to prioritize sealing efforts. Here, an optical fluid flow imaging technique, reference-free natural background–oriented schlieren imaging, was adapted to visualize air exfiltration. This is the first step in developing a method to noninvasively locate and measure exfiltration or infiltration sites so that sealing efforts can be prioritized. Experimental results of this technique are presented, demonstrating the method's applicability to visualizing exfiltration through three common building claddings in an outdoor environment. Key variables impacting the performance of this technique when applied to building leakage are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Motion tomography via occupation kernels

The goal of motion tomography is to recover a description of a vector flow field using measurements along the trajectory of a sensing unit. In this paper, we develop a predictor corrector algorithm designed to recover vector flow fields from trajectory data with the use of occupation kernels developed by Rosenfeld et al. [9,10]. Specifically, we use the occupation kernels as an adaptive basis; that is, the trajectories defining our occupation kernels are iteratively updated to improve the estimation in the next stage. Initial estimates are established, then under mild assumptions, such as relatively straight trajectories, convergence is proven using the Contraction Mapping Theorem. We then compare the developed method with the established method by Chang et al. [5] by defining a set of error metrics. Here, we found that for simulated data, where a ground truth is available, our method offers a marked improvement over [5]. For a real-world example, where ground truth is not available, our results are similar results to the established method.

97 MATHEMATICS AND COMPUTING↗