Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OUTDOORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Effects of wind on turbofan engines in outdoor static test stands

Wind can affect measured thrust and can cause turbofan engine speed to fluctuate during outdoor testing. Techniques used at an outdoor test stand at NASA Lewis Research Center to make testing easier and faster and to improve data repeatability include using an inflow control device (ICD) to make fan speed steadier, taking many raw data samples for better averaging, and correcting thrust for wind direction and speed. Data from engine tests are presented to show that the techniques improve repeatability of thrust and airflow measurements under various wind conditions. Previously announced in STAR as N83-34945

Mcardle, J. G.↗

Sensor fusion of range and reflectance data for outdoor scene analysis

In recognizing objects in an outdoor scene, range and reflectance (or color) data provide complementary information. Results of experiments in recognizing outdoor scenes containing roads, trees, and cars are presented. The recognition program uses range and reflectance data obtained by a scanning laser range finder, as well as color data from a color TV camera. After segmentation of each image into primitive regions, models of objects are matched using various properties.

Kweon, In SO↗

Autonomous robot using infrared thermal camera to discriminate objects in outdoor scene

A complete autonomous legged robot is beig designed at Carnegie Mellon University to perform planetary exploration without human supervision. This robot must traverse unknown and geographically diverse areas in order to collect samples of materials. This paper describes how thermal imaging can be used to identify materials in order to find good footfall positions and collection sites of material. First, a model developed for determining the temperature of materials in an outdoor scene is presented. By applying this model, it is shown that it is possible to determine a physical characteristic of the material: thermal inertia. Second, experimental results are described that consist in recording thermal images of an outdoor scene constituted with sand and rock. Third, results and limitations of applying the model to experimental images are analyzed. Finally, the paper analyzes how basic segmentation algorithms can be combined with the thermal inertia segmentation in order to improve the discrimination of different kinds of materials.

Caillas, C.↗

The Impact of Indoor and Outdoor Radiometer Calibration on Solar Measurements: Preprint

Accurate solar radiation data sets are critical to reducing the expenses associated with mitigating performance risk for solar energy conversion systems, and they help utility planners and grid system operators understand the impacts of solar resource variability. The accuracy of solar radiation measured by radiometers depends on the instrument performance specification, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of calibration methodologies and the resulting calibration responsivities provided by radiometric calibration service providers such as the National Renewable Energy Laboratory (NREL) and manufacturers of radiometers. Some of these radiometers are calibrated indoors, and some are calibrated outdoors. To establish or understand the differences in calibration methodology, we processed and analyzed field-measured data from these radiometers. This study investigates calibration responsivities provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The reference radiometer calibrations are traceable to the World Radiometric Reference. These different methods of calibration demonstrated 1% to 2% differences in solar irradiance measurement. Analyzing these values will ultimately assist in determining the uncertainties of the radiometer data and will assist in developing consensus on a standard for calibration.

14 SOLAR ENERGY↗

Lab Simulates Outdoor Algae Growth

Algae can be turned into renewable biofuel, which is why scientists want to discover an inexpensive, fast-growing strain of algae. Scientists at Pacific Northwest National Laboratory have developed a system to speed up this search. The unique climate-simulating system uses temperature controls and multi-colored LED lights to mimic the constantly changing conditions of an outdoor algae pond. By simulating outdoor climates inside the lab, the system saves researchers time and expense.

09 BIOMASS FUELS↗

Chilled water temperature set-point reset based on outdoor air temperature and its cooling energy performance in an office building

Here, in this study, the cooling energy performance of two strategies for controlling ChWT (chilled water temperature) are compared: the conventional control strategy of constantly fixing ChWT and the OAT (outdoor air temperature) compensation control strategy that adjusts ChWT according to the changes in OAT. OAT compensation control strategy was modeled and realized based on Appendix G of ASHRAE Standard 90.1. It was confirmed that applying OAT compensation control strategy can significantly reduce chiller energy consumption, which accounts for the largest portion of total cooling energy consumption. It was found that the difference in total cooling energy consumption between applying the conventional control of constantly fixing ChWT to 6 °C and applying the OAT compensation control was approximately 8 % and 3 % during spring (March to May) and summer (June to August), respectively. Additionally, during the fall (September–November) period, about 7 % of total cooling energy consumption could be saved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Outdoor annual algae productivity improvements at the pre-pilot scale through crop rotation and pond operational management strategies

The Development of Integrated Screening, Cultivar Optimization, and Verification Research (DISCOVR) collaborative consortium operated pre-pilot scale outdoor ponds to deliver much-needed multi-year, long-term and consistent, algae cultivation data relevant to understanding the current state of technology in terms of expected seasonal algae biomass productivity. Over the course of four years from 2018 to 2021, twelve identical 4.2 m 2 mini-ponds were run in triplicate sets to test strains and operational strategies demonstrated in small-, indoor photobioreactors, in pursuit of increasing overall algae areal productivity and projected farm yield. Fourteen different cultivars derived from a strain screening pipeline were tested. Through deliberate seasonal crop rotation and improvements in operational strategies, annual biomass productivity increased from 11.6 to 17.6 g m -2 day -1 , a > 50% increase over the 2018 baseline. Both brackish and marine strains were included and four out of the fourteen strains consistently yielded high productivity across multiple years; brackish strains Monoraphidium minutum (26BAM) and Scenedesmus obliquus (UTEX393), and marine strains Tetraselmis striata (LANL1001) and Picochlorum celeri (TG2). These freely available datasets, which represent nearly complete annual daily coverage of cultivation metrics including weather, pond temperature and pH, nutrients, and productivity, are unique in the public domain and seek to fill agronomic and operational knowledge gaps to help in the eventual commercialization of algal biofuels and bioproducts.

09 BIOMASS FUELS↗

Model calibration of a variable refrigerant flow system with a dedicated outdoor air system: A case study

With increased use of variable refrigerant flow (VRF) systems in the U.S. building sector, interests in capability and rationality of various building energy modeling tools to simulate VRF systems are rising. This paper presents the detailed procedures for model calibration of a VRF system with a dedicated outdoor air system (DOAS) by comparing to detailed measured data from an occupancy emulated small office building. The building energy model is first developed based on as-built drawings, and building and system characteristics available. The whole building energy modeling tool used for the study is U.S. DOE’s EnergyPlus version 8.1. The initial model is, then, calibrated with the hourly measured data from the target building and VRF-DOAS system. In a detailed calibration procedures of the VRF-DOAS, the original EnergyPlus source code is modified to enable the modeling of the specific VRF-DOAS installed in the building. After a proper calibration during cooling and heating seasons, the VRF-DOAS model can reasonably predict the performance of the actual VRF-DOAS system based on the criteria from ASHRAE Guideline 14-2014. The calibration results show that hourly CV-RMSE and NMBE would be 15.7% and 3.8%, respectively, which is deemed to be calibrated. As a result, the whole-building energy usage after calibration of the VRF-DOAS model is 1.9% (78.8 kWh) lower than that of the measurements during comparison period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tackling the mortality from long-term exposure to outdoor air pollution in megacities: Lessons from the Greater Cairo case study

Highlights: • Mortality due to long-term exposure to air pollution in Greater Cairo is estimated. • Air-suspended matter (PM2.5) is the most severe problem. • At least from 10240 to 15930 people die each year of exposure to PM2.5. • From 7850 to 10470 die of exposure to NO{sub 2}. The poor outdoor air quality in megacities of the developing world and its impact on health is a matter of concern for both the local populations and the decision-makers. The objective of this work is to quantify the mortality attributable to long-term exposure to PM2.5, NO{sub 2}, and O{sub 3} in Greater Cairo (Egypt).

54 ENVIRONMENTAL SCIENCES↗

Generation of a Parabolic Trough Collector Efficiency Curve from Separate Measurements of Outdoor Optical Efficiency and Indoor Receiver Heat Loss

The thermal efficiency of a parabolic trough collector is a function of both the fraction of direct normal radiation absorbed by the receiver (the optical efficiency) and the heat lost to the environment when the receiver is at operating temperature. The thermal efficiency can be determined by testing the collector under actual operating conditions or by separately measuring these two components. This paper describes how outdoor measurement of the optical efficiency is combined with laboratory measurements of receiver heat loss to obtain the thermal efficiency curve. This paper describes this approach and also makes the case that there are advantages to plotting collector efficiency versus the difference between the operating temperature and the ambient temperature at which the receiver heat loss was measured divided by radiation to a fractional power (on the order of 1/3 but obtained via data regression) - as opposed to the difference between operating and ambient temperatures divided by the radiation. The results are shown to be robust over wide ranges of ambient temperature, sky temperature, and wind speed.

14 SOLAR ENERGY↗

Floodplain Assessment for the Proposed Outdoor Fire Range Upgrades at TA-72 in Lower Sandia Canyon, Los Alamos National Laboratory

Los Alamos National Laboratory (LANL) is preparing to implement actions in Sandia Canyon at Technical Area (TA) 72. Los Alamos National Security (LANS) biologists conducted a floodplain determination and this project is partially located within a 100-year floodplain. The proposed project is to upgrade the existing outdoor shooting range facilities at TA-72. These upgrades will result in increased safety and efficiencies in the training for Protective Force personnel. In order to remain current on training requirements, the firing ranges at TA-72 will be upgraded which will result in increased safety and efficiencies in the training for Protective Force personnel (Figure 1). These upgrades will allow for an increase in class size and more people to be qualified at the ranges. Some of these upgrades will be built within the 100-year floodplain. The upgrades include: concrete pads for turning target systems and shooting positions, new lighting to illuminate the firing range for night fire, a new speaker system for range operations, canopies at two locations, an impact berm at the far end of the 300-yard mark, and a block wall for road protection.

Basic Biological Sciences(59)↗

Safety of Hydrogen Systems Installed in Outdoor Enclosures

The Hydrogen Safety Panel brings a broad cross-section of expertise from the industrial, government, and academic sectors to help advise the U.S. Department of Energy’s (DOE) Fuel Cell Technologies Office through its work in hydrogen safety, codes, and standards. The Panel’s initiatives in reviewing safety plans, conducting safety evaluations, identifying safety-related technical data gaps, and supporting safety knowledge tools and databases cover the gamut from research and development to demonstration and deployment. The Panel’s recent work has focused on the safe deployment of hydrogen and fuel cell systems in support of DOE efforts to accelerate fuel cell commercialization in early market applications: vehicle refueling, material handling equipment, backup power for warehouses and telecommunication sites, and portable power devices. This paper resulted from observations and considerations stemming from the Panel’s work on early market applications. This paper focuses on hydrogen system components that are installed in outdoor enclosures. These enclosures might alternatively be called “cabinets,” but for simplicity, they are all referred to as “enclosures” in this paper. These enclosures can provide a space where a flammable mixture of hydrogen and air might accumulate, creating the potential for a fire or explosion should an ignition occur. If the enclosure is large enough for a person to enter, and ventilation is inadequate, the hydrogen concentration could be high enough to asphyxiate a person who entered the space. Manufacturers, users, and government authorities rely on requirements described in codes to guide safe design and installation of such systems. Except for small enclosures used for hydrogen gas cylinders (gas cabinets), fuel cell power systems, and the enclosures that most people would describe as buildings, there are no hydrogen safety requirements for these enclosures, leaving gaps that must be addressed. This paper proposes that a technical basis be developed to enable code bodies to write requirements for the range of enclosures from the smallest to the largest.

08 HYDROGEN↗

Resources for National Water Savings for Outdoor Water Use

In support of efforts by the U.S. Environmental Agency's (EPA's) WaterSense program to develop a spreadsheet model for calculating the national water and financial savings attributable to WaterSense certification and labeling of weather-based irrigation controllers, Lawrence Berkeley National Laboratory reviewed reports, technical data, and other information related to outdoor water use and irrigation controllers. In this document we categorize and describe the reviewed references, highlighting pertinent data. We relied on these references when developing model parameters and calculating controller savings. We grouped resources into three major categories: landscapes (section 1); irrigation devices (section 2); and analytical and modeling efforts (section 3). Each category is subdivided further as described in its section. References are listed in order of date of publication, most recent first.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Outdoor Irrigation Measurement and Verification Protocol

This measurement and verification (M&V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings resulting from water conservation measures (WCMs) in energy performance contracts associated with outdoor irrigation efficiency projects. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M&V plan, and details the procedures to use to determine water savings.

13 HYDRO ENERGY↗

Outdoor Irrigation Measurement and Verification Protocol

This measurement and verification (M&V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings resulting from water conservation measures (WCMs) in energy performance contracts associated with outdoor irrigation efficiency projects. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M&V plan, and details the procedures to use to determine water savings.

13 HYDRO ENERGY↗

Outdoor Lighting Challenges and Solution Pathways

This document describes outdoor lighting solutions that municipalities are adopting to help create a safe environment for residents and business owners. The report describes the accelerated market adoption of LED streetlights.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Key Accomplishments & Results: Outdoor Lighting Accelerator

This document provides a high-level summary of the results of the Better Buildings Outdoor Lighting Accelerator, which worked with states, cities, regional energy networks, and utilities to accelerate the deployment of high-performance street and area lighting in the public sector.

Lighting, Exterior Lighting, Outdoor Lighting, LED↗