Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OSMOSIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Renewable Energy Forward Osmosis Desalination System

An Autonomous Desalination System (ADS) that can operate completely off-grid is described. The ADS obtains all of its energy from Concentrated Solar Power (CSP) using a thermoelectric generator to convert some of the thermal energy into electrical energy. The electrical energy and the waste thermal energy from the TEG are in turn used to power a thermally based Forward Osmosis (FO) desalination system. With no energy cost, the ADS can potentially produce water at a lower cost than commercially available desalination systems.

30 DIRECT ENERGY CONVERSION↗

Forward Osmosis-based System for Treatment of Waste Water Generated During Energy Production Using Waste Carbon Dioxide and Waste Heat

For this project, we performed initial studies investigating the feasibility of a system that would capture carbon dioxide from post-combustion flue gas and use the CO 2 to drive the treatment of wastewater. Our system can remove carbon dioxide for storage (as pure CO 2 ) using low-grade waste heat from the power plant to power the process. As an additional benefit, our system can provide clean water for reuse in the plant where the purification process is driven by carbon dioxide. The COHO (CO 2 -H 2 O) system uses a breakthrough forward osmosis membrane developed by Porifera in combination with a recyclable draw solvent developed by Idaho National Laboratory to efficiently treat wastewater and consume carbon dioxide. With this research, we determined that COHO is able to capture up to 75% of a power plant’s CO 2 emissions if supplying and treating the boiler water feed. The installation of COHO at a power plant will (1) reduce wastewater volumes, (2) reduce the energy costs to treat wastewater, (3) expand the capabilities of water treatment all while (4) reducing the cost of carbon capture from flue gas.

20 FOSSIL-FUELED POWER PLANTS↗

Acetonitrile Destruction and Fate of Organics in the Reverse Osmosis System at the ETF

The Hanford Site Effluent Treatment Facility (ETF) currently treats aqueous waste streams that include condensates from the 242-A evaporator, leachate from the Environmental Restoration Disposal Facility (ERDF), as well as laboratory wastes and, in the future, will treat liquid effluents from the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and Integrated Disposal Facility (IDF) leachate. Liquid effluents from the WTP will have significant concentrations of acetonitrile. Acetonitrile is formed by reaction of nitrates and sugar in the WTP low activity waste (LAW) melters and is prevalent in the submerged bed scrubber (SBS) and wet electrostatic precipitator (WESP) liquid effluents from WTP off-gas treatment. When these liquids are concentrated in the WTP Effluent Management Facility (EMF) evaporator in the direct feed low activity waste (DFLAW) flow-sheet, testing has shown that the majority of the acetonitrile partitions to the evaporator condensate. Since the evaporator condensate is directed to the ETF, this creates a potential issue with the ETF waste acceptance criteria. Consequently, there is a need to validate flow-sheet assumptions on the fate of acetonitrile and other organics within the ETF. The present plan includes the addition of a steam stripper to the ETF to remove acetonitrile. There is, therefore, also a need to determine a suitable method to destroy acetonitrile in the overhead condensate stream from the new steam stripper. Washington River Protection Solutions, LLC (WRPS) previously contracted with Atkins and the Vitreous State Laboratory (VSL) of The Catholic University of America (CUA) to perform development and testing work to evaluate potential methods for destruction of acetonitrile in WTP secondary liquid effluents. Based on the results of that work, WRPS requested that follow-on testing be conducted to further evaluate acetonitrile destruction in the steam stripper condensate using ultraviolet oxidation (UV/OX) with persulfate. WRPS also requested testing to assess the rejection rate of organics in the reverse osmosis (RO) system installed in the ETF. This report presents the results from testing to address those needs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Comparison of Power Take-Off Architectures for Wave-Powered Reverse Osmosis Desalination of Seawater with Co-Production of Electricity

Several power take-off (PTO) architectures for wave-powered reverse osmosis (RO) desalination of seawater are introduced and compared based on the annual average freshwater production and the size of the components, which strongly relate to the costs of the system. The set of architectures compared includes a novel series-type PTO architecture not previously considered. These seawater hydraulic PTO architectures are composed of a WEC-driven pump, an RO module, an intake charge pump driven by an electric motor, and a hydraulic motor driving an electric generator for electric power production. This study is performed using an efficient two-way coupled steady-state model for the average performance of the system in a given sea state, including freshwater permeate production, electric power production, and electric power consumption. A multi-objective design problem is formulated for the purposes of this comparative study, with the objectives of maximizing annual freshwater production, minimizing the displacement of the WEC-driven pump, and minimizing the installed RO membrane area. This establishes a framework for comparison in the absence of a mature techno-economic model. The requirement that the system produces enough electric power to meet its consumption is applied as a constraint on the operation of the system. The oscillating wave surge converter Oyster 1 is assumed as the WEC. Weights on performance of the system in a given sea state are based on historical data from Humboldt Bay, CA. This study finds that (1) architectures in a series configuration allow for a reduction in the WEC-driven pump size of 59–92% compared to prior work, (2) varying the displacement of the WEC-driven pump between sea conditions does not provide any significant advantage in performance, and (3) varying the active RO membrane area between sea condition offers improvements between 7% and 41% in each design objective.

Energy & Fuels↗

Calcium Sulfate and Calcium Carbonate Scaling of Thin-Film Composite Polyamide Reverse Osmosis Membranes with Surface-Tethered Polyacrylic Acid Chains

The gypsum and calcite scaling propensities of the thin-film composite polyamide (PA-TFC) reverse osmosis (RO) membrane, modified with a tethered surface layer of polyacrylic acid (PAA) chains, was evaluated and compared to the scaling of selected commercial RO membranes. The tethered PAA layer was synthesized onto a commercial polyamide membrane (i.e., base-PA) via atmospheric pressure plasma-induced graft polymerization (APPIGP). The PAA nano-structured (SNS) base-PA membrane (SNS-PAA-PA) was scaled to a lesser degree, as quantified by a lower permeate flux decline and surface imaging, relative to the tested commercial membranes (Dow SW30, Toray SWRO, and BWRO). The cleaning of gypsum-scaled membranes with D.I. water flushing achieved 100% water permeability recovery for both the SNS-PAA-PA and Dow SW30 membranes, relative to 92–98% permeability restoration for the Toray membranes. The calcium carbonate scaling of SNS-PAA-PA membranes was also lower relative to the commercial membranes, but permeability recovery after D.I. water cleaning was somewhat lower (94%) but consistent with the level of surface scale coverage. In contrast, the calcite and gypsum-scaled membrane areas of the commercial membranes post-cleaning were significantly higher than for the SNS-PAA-PA membrane but with 100% permeability recovery, suggesting the potential for membrane damage when mineral scaling is severe.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Hydraulic and Electric Reverse Osmosis Wave Energy Converter (HERO WEC)

The Hydraulic and Electric Reverse Osmosis Wave Energy Converter (HERO WEC) is a 6-ft wave energy device that turns seawater into drinking water. It is designed for rapid deployment in disaster response scenarios where fresh water is limited. Featuring both hydraulic and electric power takeoff systems, HERO WEC has undergone two ocean deployments at Jennette's Pier on the Outer Banks of North Carolina in addition to extensive in-lab testing. The research provides practical insights into the real-world challenges of wave energy conversion beyond modeling and dry-lab environments. Attendees will develop an understanding of the practical considerations for deploying wave energy devices and the lessons learned from real-world HERO WEC deployments.

16 TIDAL AND WAVE POWER↗

Cost-optimal selection of pH control for mineral scaling prevention in high recovery reverse osmosis desalination

Conference proceedings for Foundations of Computer Aided Process Design (FOCAPD) 2024 that details a cost optimization model for pH control to prevent mineral scaling in high recovery reverse osmosis. This work applies a framework for incorporating detailed water chemistry predictions such as precipitation, pH change, and mineral scaling tendencies with process-scale optimization. It demonstrates that the acid choice for pH control can have a significant impact on pretreatment costs.

Amusat, Oluwamayowa↗

Black-box optimization of a closed-circuit reverse osmosis system for desalination through extremum seeking control

We study the minimization of the cost function of a closed-circuit desalination reverse osmosis (CCRO) system, which is used for producing drinking water. The cost function is a trade-off between the specific energy consumption and the specific brine management cost. The extremum-seeking controller (ESC) manipulates the critical electric conductivity of the brine to minimize the cost function. Experiments were designed in which the composition of the feed salinity is increased to test the controller’s ability to converge to a new optimum. The ESC was able to shift the critical conductivity to a new optimum, which resulted in a 9% improvement in the cost function.

Chowdhury, Dhruba↗

Spectral Analysis of Regular Material Point Method and its Application to Study High Pressure Reverse Osmosis Membrane Compaction and Embossing

Material Point Method (MPM) is gaining widespread interest in applied continuum mechanics. The fact that all the continuum properties are stored on the particles (or material points) and the governing equations are solved on these material points makes MPM extremely suited to problems involving severe material deformations, such as crack propagation, soil movement, and fluid flows. Despite its popularity, only a few studies have focused on the numerical properties of MPM. This presentation introduces a global spectral analysis of the regular material point method. Contrary to previous studies, the analysis focuses on the numerical properties of the method in the spectral space. The amplification factor is derived as a function of the non- dimensional wave numbers. It provides insights into the stability and dissipative properties of the method for various CFL and Fourier numbers. The effect of the grid shape functions, number of particles per cell and their locations inside the grid cell are also analyzed. The EXAGOOP MPM solver (https://github.com/NREL/Exagoop.git) is developed at the National Renewable Energy Laboratory as a part of the NAWI UHPRO project and is based on the AMReX framework. A single-level, uniform cartesian grid is used as the background mesh, while the particle class in AMReX is used to manage the material point operations. Linear hat and B-splines are used as grid shape functions, while the time integration is performed using explicit Euler time integration. EXAGOOP is both CPU and GPU compatible and has been demonstrated to work well on multiple compute architectures. The performance of EXAGOOP on various computing architectures is presented along with its application to study compaction and embossing of high-pressure reverse osmosis membranes. The MPM solution accurately reproduces the membrane deformation. The deformed pore size and structure simulated using MPM also agree well with experimental SEM images.

material point method↗

Stimulated Raman Scattering Microscopy: Real-Time In-Situ Physical and Chemical Characterization of Reverse Osmosis Desalination Membrane Scaling

We introduce a stimulated Raman scattering (SRS) methodology designed for rapid, real-time, and in situ monitoring of RO membrane scaling adapted for bench-scale desalination flow cells. The methodology can provide new insights into membrane scaling dynamics by offering time-resolved reflection imaging of inorganic crystal growth, coupled with chemical identification from Raman spectral data. These capabilities allow for direct local measurement of the membrane surface area covered by different scalants as well as an approximation of the scalant volume using three-dimensional, integrated Raman intensity. The 2D and 3D SRS results obtained from CaSO 4 scaling experiments are compared to and are in reasonable agreement with those provided by confocal microscopy. The real-time physical and chemical characterization capabilities presented here could be extended to study combinations of inorganic, organic, and biological fouling. Overall, the SRS methodology represents an advancement in real-time sensing of membrane fouling that offers the potential for improved operation, lower cost, and more resilient RO membrane systems for sustainable water management.

42 ENGINEERING↗

Ionic Liquid-Mediated Interfacial Polymerization for Fabrication of Reverse Osmosis Membranes

This study revealed the effects of incorporating ionic liquid (IL) molecules: 1-ethyl, 1-butyl, and 1-octyl-3-methyl-imidazolium chlorides with different alkyl chain lengths, in interfacial polymerization (IP) on the structure and property (i.e., permeate-flux and salt rejection ratio) relationships of resulting RO membranes. The IL additive was added in the aqueous meta-phenylene diamine (MPD; 0.1% w/v) phase, which was subsequently reacted with trimesoyl chloride (TMC; 0.004% w/v) in the hexane phase to produce polyamide (PA) barrier layer. The structure of resulting free-standing PA thin films was characterized by grazing incidence wide-angle X-rays scattering (GIWAXS), which results were correlated with the performance of thin-film composite RO membranes having PA barrier layers prepared under the same IP conditions. Additionally, the membrane surface properties were characterized by zeta potential and water contact angle measurements. It was found that the membrane prepared by the longer chain IL molecule generally showed lower salt rejection ratio and higher permeation flux, possibly due to the inclusion of IL molecules in the PA scaffold. This hypothesis was supported by the GIWAXS results, where a self-assembled surfactant-like structure formed by IL with the longest aliphatic chain length was detected.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗