Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear Cables”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

CORRTEX Analysis Techniques

Continuous Reflectometry for Radius versus Time Experiments, or CORRTEX, is a diagnostic that was developed during nuclear testing to measure the distance at which rock walls were disrupted by an explosive device as a function of the time at which disruption occurred. Distances recorded are dynamic measurements of cable length as the shockwaves from an explosive event crush the experiment cables, reducing their usable length. Applications of the CORRTEX diagnostic have been expanded in recent times to include instrumentation of the explosive device itself, to record phenomena such as the speed of the detonation wave in the explosive charge and the crushing or disassembly of material in the charge housing. The diagnostic has likewise been used to monitor explosive performance in rock blasting and oil well hole-clearing activities.

42 ENGINEERING↗

Uranium Single Particle Analysis for Simultaneous Fluorine and Uranium Isotopic Determinations via Laser-Induced Breakdown Spectroscopy/Laser Ablation–Multicollector–Inductively Coupled Plasma–Mass Spectrometry

Uranyl fluoride (UO 2 F 2 ) particles (<20 μm) were subjected to first-of-its-kind analysis via simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation multi-collector inductively coupled plasma–mass spectrometry (LA–MC–ICP–MS). Briefly, a nanosecond pulsed high-energy laser was focused onto the sample (particle) surface. In a single laser pulse, the UO 2 F 2 particle was excited/ionized within the microplasma volume, and the emission of light was collected via fiber optics such that emission spectroscopy could be employed for the detection of uranium (U) and fluorine (F). The ablated particle was simultaneously transported into the MC–ICP–MS for high precision isotopic (i.e., 234 U, 235 U, and 238 U) analysis. This method, LIBS/LA–MC–ICP–MS was optimized and employed to rapidly measure 80+ UO 2 F 2 particles, which were subjected to different calcination processes, which results in varying degrees of F loss from the individual particles. In measuring the particles, the average F/U ratios for the populations treated at 100 and 500 °C were 2.78 ± 1.28 and 1.01 ± 0.50, respectively, confirming loss of F through the calcination process. The average 235 U/ 238 U on the particle populations for the 100 and 500 °C were 0.007262 (22) and 0.007231 (23), which was determined to be <0.2% from the expected value. The 234 U/ 238 U ratios on the same particles were 0.000053 (11) and 0.000050 (10) for the 100 and 500 °C, respectively, <10% from the expected value. Notably, each population was analyzed in under 5 min, demonstrating the truly rapid analysis technique presented here in this paper.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

White Rabbit Time Synchronization for Radiation Detector Readout Electronics

As radiation detector arrays in nuclear physics applications become larger and physically more separated, the time synchronization and trigger distribution between many channels of detector readout electronics become more challenging. Clocks and triggers are traditionally distributed through dedicated cabling, but newer methods such as the IEEE 1588 Precision Time Protocol and White Rabbit allow clock synchronization through the exchange of timing messages over Ethernet. Consequently, we report here the use of White Rabbit in a new detector readout module, the Pixie-Net XL. Herein, the White Rabbit core, data capture from multiple digitizing channels, and subsequent pulse processing for pulse height and constant fraction timing are implemented in a Kintex 7 FPGA. The detector data records include White Rabbit time stamps and are transmitted to storage through the White Rabbit core's gigabit Ethernet data path or a slower diagnostic/control link using an embedded Zynq processor. The performance is characterized by time-of-flight style measurements and by time correlation of high energy background events from cosmic showers in detectors separated by longer distances. Software for the Zynq processor can implement "software triggering", for example to limit recording of data to events where a minimum number of channels from multiple modules detect radiation at the same time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SYSM-562: DIM Fiber Connection Improvement Analysis

The National Ignition Facility is equipped with a wide suite of diagnostics including optical, x-ray, and neutron diagnostics to analyze experiments and look for areas of improvements. NIF diagnostics are either deployed to a fixed location on the target chamber or on a Diagnostic Instrument Manipulator (DIM). DIMs are two-stage telescoping devices used to insert, retract, position, and align a diagnostic instrument in the target chamber. Additionally, DIMs provide a standard set of cables to support operation of all DIM-based diagnostic instruments.

42 ENGINEERING↗

Reflections

Flash radiography is a much used diagnostic technique for high-explosively driven hydrodynamic experiments. Two linear-induction electron accelerators (LIAs) at the Los Alamos Dual Axis Radiography of Hydrodynamic Tests (DARHT) facility provide the source spots for point projection radiography of exceptionally large and dense experiments. In these LIAs, the beam acceleration is provided by high-voltage pulses applied to a number of inductively isolated gaps. The high-voltage pulses are produced by remotely located pulsedpower generators and delivered to the gaps by long highvoltage cables. For Scorpius, these pulse generators are called line replacement units (LRUs).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wireless System Development for GaN-Based Transmitters for Advanced Nuclear Reactor Environments

The market for consumer electronics is dominated by Si-based electronics. Many Si-based complementary metal–oxide–semiconductor (CMOS) devices are reaching their limitations in terms of switching frequencies, voltages, currents, and temperatures. Furthermore, these devices are widely known to be susceptible to ionizing radiation and neutrons. Advanced nuclear reactors, especially microreactors and small modular reactors, require wireless electronics that can survive larger neutron and gamma doses than Si CMOS. Because of their size, electronics will need to be placed closer to the reactor cores, and cabling capabilities may be limited. However, GaN high-electron-mobility transistors (HEMTs) have been shown to switch faster with higher gains, and they can achieve current and voltage limits beyond traditional Si CMOS. However, they have less market maturity and have undergone less testing. These GaN HEMTs have been shown to survive ionizing radiation with little effects, but the effects of neutron radiation remain widely unknown. In this report, a wireless electronic system capable of supporting multiple radiation-hardened (rad-hard) sensors is presented. The proposed transmission scheme was designed to be simple to increase the likelihood of success in the immature GaN HEMT process and in high-radiation environments. The transmission system was tested using software-defined radios to emulate the transmission scheme before the transmitter circuitry in the GaN process was developed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A comparison of lightning and nuclear electromagnetic pulse response of a helicopter

A numerical modeling technique is utilized to investigate the response of a UH-60A helicopter to both lightning and nuclear electromagnetic pulses (NEMP). The analytical approach involves the three-dimensional time domain finite-difference solutions of Maxwell's equations. Both the external currents and charges as well as the internal electromagnetic fields and cable responses are computed. Results of the analysis indicate that, in general, the short circuit current on internal cables is larger for lightning, whereas the open-circuit voltages are slightly higher for NEMP. The lightning response is highly dependent upon the rise time of the injected current as was expected. The analysis shows that a coupling levels to cables in a helicopter are 20 to 30 dB larger than those observed in fixed-wing aircraft.

C C Easterbrook↗

(Paper) TRIPWIRE: Multi-modal Distributed Sensing For Repository Verification

Underground geological repositories for storing used nuclear fuel are being planned and developed around the world. Research is being performed to understand technical aspects of sealing entombed materials and underground repositories to ensure the radiological and nuclear materials remain contained. To support safeguards verification for these facilities research at Idaho National Laboratory (INL) is underway to develop and demonstrate a multi-modal sensor system, TRIPWIRE, for containment verification in inaccessible radiological and nuclear waste repositories. The TRIPWIRE system will continuously monitor ionizing radiation and electromagnetic fields in the vicinity of emplaced nuclear materials buried in a repository, reporting on disturbances with a real-time alarm control station. The system will use long-length scintillating fiber bundles (SFBs) to perform area radiation monitoring; these will be coupled to kilometer-scale multimodal optical communication fibers – all light sensors and electronic components used with this system will be located above ground. Electromagnetic fields, and changes in local dielectric conditions caused by intrusion and soil movement, will be monitored using commercial grade, ported "leaky" coaxial cables (PCCs), with control electronics also located above ground. Tamper-indicating self-diagnostic assessments will be done using optical and electronic time domain reflectometry in the SFBs and PCCs, respectively. The result will be a long, kilometer-scale multi-modal SFB-PCC system. Simulation and modeling are being used to inform the work and a demonstration of the system's utility is planned at a nuclear storage facility in the future.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

NRIC DOME Crane Trade Study and Recommendation

The National Reactor Innovation Center (NRIC) is a national program that was established as part of the Nuclear Energy Innovation Capabilities Act (NEICA). NRIC’s mission is to accelerate the demonstration and deployment of advanced nuclear energy through its mission to inspire stakeholders and the public, empower innovators, and deliver successful outcomes through efficient coordination of partners and resources. NRIC is designed to bridge the gap between research, development, and the marketplace to help convert some of the nation’s most promising advanced nuclear reactors into commercial applications. The NRIC Demonstration of Microreactor Experiments (DOME) facility, formerly known as Experimental Breeder Reactor II (EBR II), located at the Materials and Fuels Complex (MFC) at the Idaho National Laboratory (INL) is intended to allow industrial and other partners the opportunity to test Advanced Microreactors up to 20MW thermal power. The 75-ton capacity polar crane located in the EBR II facility was rendered inoperable to support planned facility demolition in 2015; small holes were flame cut in the girders; hoists and cables were removed; oil was drained from gear boxes; trolley drive, and then filled with absorbent; and the electrical and control umbilical’s were disconnected, removed and disposed. Subsequently, the decision was made to convert the EBR II facility into the DOME test bed.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Slow Scan Telemedicine

Originally developed under contract for NASA by Ball Bros. Research Corporation for acquiring visual information from lunar and planetary spacecraft, system uses standard closed circuit camera connected to a device called a scan converter, which slows the stream of images to match an audio circuit, such as a telephone line. Transmitted to its destination, the image is reconverted by another scan converter and displayed on a monitor. In addition to assist scans, technique allows transmission of x-rays, nuclear scans, ultrasonic imagery, thermograms, electrocardiograms or live views of patient. Also allows conferencing and consultation among medical centers, general practitioners, specialists and disease control centers. Commercialized by Colorado Video, Inc., major employment is in business and industry for teleconferencing, cable TV news, transmission of scientific/engineering data, security, information retrieval, insurance claim adjustment, instructional programs, and remote viewing of advertising layouts, real estate, construction sites or products.

Source record↗

Upgrades of the ATLAS Zero Degree Calorimeter System for Run 3 at the Large Hadron Collider

Experimental studies of ultra-relativistic heavy ion collisions at the Large Hadron Collider (LHC) depend crucially on Zero Degree Calorimeters (ZDCs) that measure neutrons produced at near-beam rapidity in nucleus-nucleus collisions. In hadronic nuclear collisions these neutrons are mainly spectator neutrons, those that do not scatter from opposing nucleons during the collision. As a result, the ZDCs provide a vital probe of heavy ion collision geometry. The ZDCs are also essential in the study of ultra-peripheral collisions that are initiated by photons associated with the electric fields of one or both nuclei. Coherent photon emission typically leaves the photon emitter intact, making the observation of no ZDC signal, on one or both sides, a tag of such processes. The ATLAS ZDCs, built prior to Run 1 were substantially upgraded for LHC Run 3. The primary upgrades included replacement of the quartz Cherenkov radiator with $\text{H}_2$-doped fused silica rods; installation of fast air-core signal cables between the ZDC and the ATLAS USA15 cavern; new LED-based calibration system; and new electronics implemented for readout and fully-digital triggering. The ZDCs were also augmented with new "Reaction Plane Detectors" (RPDs) designed to measure the transverse centroid of multi-neutron showers to allow event-by-event reconstruction of the directed-flow plane in nuclear collisions. The Run~3 ZDC detectors, including the RPDs, are described in detail with emphasis on aspects that are new for Run~3.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Upgrades of the ATLAS zero degree calorimeter system for Run 3 at the Large Hadron Collider

Experimental studies of ultra-relativistic heavy ion collisions at the Large Hadron Collider (LHC) depend crucially on Zero Degree Calorimeters (ZDCs) that measure neutrons produced at near-beam rapidity in nucleus-nucleus collisions. In hadronic nuclear collisions these neutrons are mainly spectator neutrons, those that do not scatter from opposing nucleons during the collision. As a result, the ZDCs provide a vital probe of heavy ion collision geometry. The ZDCs are also essential in the study of ultra-peripheral collisions that are initiated by photons associated with the electric fields of one or both nuclei. Coherent photon emission typically leaves the photon emitter intact, making the observation of no ZDC signal, on one or both sides, a tag of such processes. The ATLAS ZDCs, built prior to Run 1, were substantially upgraded for LHC Run 3. The primary upgrades included replacement of the quartz Cherenkov radiator with H_2-doped fused silica rods; installation of fast air-core signal cables between the ZDC and the ATLAS USA15 cavern; a new LED-based calibration system; and new electronics implemented for readout and fully-digital triggering. The ZDCs were also augmented with new “Reaction Plane Detectors” (RPDs) designed to measure the transverse centroid of multi-neutron showers to allow event-by-event reconstruction of the directed-flow plane in nuclear collisions. The Run 3 ZDC detectors, including the RPDs, are described in detail with emphasis on aspects that are new for Run 3.

43 PARTICLE ACCELERATORS↗

LWR Aging Management for Life Beyond 80

While several decades of materials degradation research enabled the current US fleet of Light Water Reactors (LWR) to plan to produce electrical power through extended operations up to 80 years of plant life, it now seems appropriate to evaluate what issues, methods, and timelines need to be considered to meet the expected electric power demands for life beyond eighty (LBE) years. To address these questions, it will be necessary to review the electrical capacity and the projected LWR fleet capacity including new builds and advanced reactors. This effort should begin with a materials degradation assessment focused on known and possible unknown issues using a reduced Expanded Materials Degradation Assessment [1], which was employed to identify knowledge gaps for a second license renewal (60-80 yrs.). The focus of the LBE assessment should include: Establishing a timeline to initiate assessments of possible materials aging issues and to ensure sufficient time to evaluate materials degradation research gaps; assessing components and materials to be evaluated, e.g., metals (reactor pressure vessels and alloys within and outside the pressure boundary), concrete, cables, as well as mitigation methods, advanced monitoring, and validation with ex-service materials; initiating a LBE research plan focused on developing an expanded mechanistic understanding of materials degradation and refined models through Codes and Standards evaluation for use by the nuclear industry; and maintaining and strengthening the nuclear materials human knowledge base to address new and as yet unknown degradation modes.

Chen, Xiang↗

Residual resistance ratio measurement system for Nb 3 Sn wires extracted from Rutherford cables

Residual resistance ratio (RRR) of superconducting strands is an important parameter for magnet electrical stability. RRR serves as a measure of the low-temperature electrical conductivity of the copper within a conductor that has a copper stabilization matrix. For Nb 3 Sn, due to the need of a reaction heat treatment, the technical requirements for high quality measurements of strands extracted from Rutherford cables are particularly demanding. Quality of wire, cabling deformation, heat treatment temperature, heat treatment atmosphere, sample handling, and measurement methods can all affect the RRR. Therefore, as an integral part of the electrical quality control (QC) of Nb 3 Sn Rutherford cables manufactured at the Lawrence Berkeley National Laboratory, it was prudent that we established a RRR measurement system that can isolate the assessment of cable-fabrication-related impacts from sample preparation and measurement factors. Here we describe a bespoke cryocooler-based measurement system, capable of measuring RRR of over 80 samples in a single cooldown. The samples are mounted on custom-designed printed circuit boards that accommodate the shape of strands extracted from a Rutherford cable without added deformation, which we will show is critical in ensuring that the measurements accurately represent the RRR values of the conductor within the cable. Using this sample mounting solution, we routinely measure the overall RRR of the strand as well as individual intra-strand sections corresponding to both cable edges and cable broad faces with high reproducibility. Such measurements provide valuable information on the variation of RRR along the length of the strands as well as across strand productions and cable runs over time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Initial Characterization and Optimization of the Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Orbitrap Mass Spectrometer for the Determination of Plutonium

Plutonium measurements are essential to the nuclear forensics and safeguards community. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled with an Orbitrap mass spectrometer is a proven platform for uranium isotope ratio determinations. Here, this work expands the LS-APGD-Orbitrap platform capabilities by reporting the first-ever analysis of plutonium with the LS-APGD and the first-ever measurement of elemental plutonium with an Orbitrap mass spectrometer. This coupling has the potential to dramatically reduce the complex sample manipulations required for traditional analysis techniques employed for actinide isotope ratio determinations. As a first step toward the goal of simultaneous uranium and plutonium isotope ratio determinations, the initial characterization and optimization of the platform for the detection of plutonium are reported. Collision-induced dissociation modality settings were optimized to reduce water-related and other molecular clusters containing plutonium, maximizing 242 Pu 16 O 2 + responses. A design of experiments study was conducted to optimize the discharge conditions of the dual-electrode LS-APGD toward the responsivity of 242 Pu 16 O 2 +. The measurement sensitivity was determined from a Pu response curve, yielding a limit of detection of 10 fg (absolute) of total analyte when data was collected and processed with a Spectroswiss FTMS Booster X2 data acquisition system. Additionally, plutonium and uranium were measured in a simultaneous acquisition, and each analyte remained unaffected by the other. It is believed that the LS-APGD-Orbitrap platform could be a valuable addition to the nuclear forensics’ toolbox and, indeed, other scientific disciplines and regulatory communities in which rapid, high-resolution plutonium determinations are paramount.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Overview of the front-end electronics of CMS HGCal - including readout and powering

The end-cap calorimeters of CMS will be upgraded to a single High Granularity Calorimeter (HG-Cal) for the HL-LHC, including both silicon sensors and scintillator tiles with on-tile SiPMs as active elements. The readout of the active elements is performed by an ASIC (HGCROC in 130 nm CMOS technology) that measures the amplitude and arrival time of the signals. The amplitude is measured over a large dynamic range to allow calibration with single particles and the measurement of TeV showers. The time of arrival of high-energy showers will be measured with a precision of around 30 ps. A second pair of “concentrator” ASICs - ECON-T and ECON-D - takes the data from the HGCROC channels and packages them for transmission via optical links to the off-detector electronics. The ECON-T transmits trigger data at 40 MHz, to form part of the level-1 trigger. The ECON-D transmits concentrated data packets at up to 1 MHz, upon reception of a level-1 trigger signal. In addition to these ASICs, HGCal will use modified versions of common HL-LHC electronics developments, for the power chain and the optical control and readout. The dense nature of the HGCal provides additional challenges for the electronic boards and cabling. In this proceedings the overall HGCal front electronics scheme, including the latest performance of the HGCROC and ECON ASICs is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Low Cost SIPM Evaluation and Control Prototyping System including accurate bias voltage generation, leakage current measurement, and temperature control using Peltier cooling

We describe an electronics system to operate SIPMs in the laboratory. The system is comprised of a single channel amplifier board (SIPM Amp) and a 4-channel control board to which up to 4 SIPM Amp boards can be connected. The control board supplies a common low voltage power for the amplifiers. All channels feature individually regulated bias and Peltier power voltages, along withPt10K RTD readout. A graphical user interface allows control of the bias voltages, amplifier voltage, Peltier voltages, and also provides for readback of leakage currents and other voltages. The GUI app has a feedback loop to measure the SIPM temperature (with the PT10K) and generate correction voltages to the Peltier to regulate the temperature. The temperatures, which can be achieved by Peltier cooling depend on the thermal design of the setup, the practical limit being about 50C below ambient. The SIPM Amp. board is a small (3x5cm) PCB that has a single SIPM readout channel. The SIPM scan be surface mounted on the pcb or connected to a 2-pin 0.100" socket. The area around the SIPM footprint is thermally isolated by perforations in the PCB. The RTD is located inside the thermal break. Onboard is BV and LV filtering. The 10X amplifier is based on MiniCircuits' GALI-S66+ integrated circuit, tweaked for a 6V power. The amplifier was selected for a combination of high bandwidth, low noise, and low power. An accoupled amplifier output is connected to an SMA connector. For best operation of this inverting amplifier the output signal should be in the range of 0 to -1V.The Amplifier board is connected to the Control board with a 10-conductor 0.025" pitch ribbon cable, carrying all the services. Peltier power for currents more than 1A should use a separate 2-contact connector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗