Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Notes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A note on entropic force and brane cosmology

Recently Verlinde proposed that gravity is an entropic force caused by information changes when a material body moves away from the holographic screen. In this note we apply this argument to brane cosmology, and show that the cosmological equation can be derived from this holographic scenario.

79 ASTRONOMY AND ASTROPHYSICS↗

A note on the role of the boundary terms for the non-Gaussianity in general k-inflation

In this short note we clarify the role of the boundary terms in the calculation of the leading order tree-level bispectrum in a fairly general minimally coupled single field inflationary model, where the inflaton's Lagrangian is a general function of the scalar field and its first derivatives. This includes k-inflation, DBI-inflation and standard kinetic term inflation as particular cases. These boundary terms appear when simplifying the third order action by using integrations by parts. We perform the calculation in the comoving gauge obtaining explicitly all total time derivative interactions and show that a priori they cannot be neglected. The final result for the bispectrum is equal to the result present in the literature which was obtained using the field redefinition.

79 ASTRONOMY AND ASTROPHYSICS↗

Note on structure formation from cosmic string wakes

The search for cosmic strings has been of renewed interest with the advent of precision cosmology. In this note we give a quantitative description of the nonlinear matter density fluctuations that can form from a scaling network of cosmic string wakes. Specifically, we compute the distribution of dark matter halos. These halos would possess strong correlations in position space that should have survived until today. We also discuss the challenges involved in their detection due to their small size and the complex dynamics of their formation.

79 ASTRONOMY AND ASTROPHYSICS↗

Note on the Green’s function formalism and topological invariants

It has been discovered previously that the topological order parameter could be identified from the topological data of the Green's function, namely the (generalized) TKNN invariant in general dimensions, for both non-interacting and interacting systems. In this note, we show that this phenomenon has a clear geometric derivation. In conclusion, this proposal could be regarded as an alternative proof for the identification of the corresponding topological invariant and the topological order parameter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

“MODAL NOISE” IN SINGLE-MODE FIBERS: A CAUTIONARY NOTE FOR HIGH PRECISION RADIAL VELOCITY INSTRUMENTS

Exploring the use of single-mode fibers (SMFs) in high precision Doppler spectrometers has become increasingly attractive since the advent of diffraction-limited adaptive optics systems on large-aperture telescopes. Spectrometers fed with these fibers can be made significantly smaller than typical “seeing-limited” instruments, greatly reducing cost and overall complexity. Importantly, classical mode interference and speckle issues associated with multi-mode fibers, also known as “modal noise,” are mitigated when using SMFs, which also provide perfect radial and azimuthal image scrambling. However, SMFs do support multiple polarization modes, an issue that is generally ignored for larger-core fibers given the large number of propagation modes. Since diffraction gratings used in most high resolution astronomical instruments have dispersive properties that are sensitive to incident polarization changes, any birefringence variations in the fiber can cause variations in the efficiency profile, degrading illumination stability. Here we present a cautionary note outlining how the polarization properties of SMFs can affect the radial velocity (RV) measurement precision of high resolution spectrographs. This work is immediately relevant to the rapidly expanding field of diffraction-limited, extreme precision RV spectrographs that are currently being designed and built by a number of groups.

79 ASTRONOMY AND ASTROPHYSICS↗

Note on tachyon moduli and closed strings

The collective behavior of the SL(2,R) covariant brane states of noncritical c=1 string theory, found in a previous work, is studied in the Fermi liquid approximation. It is found that such states mimic the coset WZW model, whereas only by further restrictions one recovers the double-scaling limit which was purported to be equivalent to closed string models. Another limit is proposed, inspired by the tachyon condensation ideas, where the spectrum is the same of two-dimensional string theory. We close by noting some strange connections between vacuum states of the theory in their different interpretations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Note about Hamiltonian formulation of modified F(R) Horava-Lifshitz gravities and their healthy extension

This note is devoted to the study of Hamiltonian formulation of modified F(R) Horava-Lifshitz theories of gravity that were proposed recently by Chaichian and collaborators [arXiv:1001.4102]. We also study Hamiltonian formulation of the healthy extended Horava-Lifshitz gravities and show that these theories have the Hamiltonian structure that is different from Hamiltonian formulation general relativity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Brief note on Ashtekar-Magnon-Das conserved quantities in quadratic curvature theories

In this note, we correct a mistake in the mass formula in [N. Okuyama and J. i. Koga, Phys. Rev. D 71, 084009 (2005).] which generalizes the Ashtekar-Magnon-Das method to incorporate extended gravities with quadratic curvature terms. The corrected mass formula confirms that the black hole masses for recently discovered critical gravities vanish.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Technical note: The calibration of {sup 90}Y-labeled SIR-Spheresusing a nondestructive spectroscopic assay

{sup 90}Y-labeled SIR-Spheres are currently used to treat patients with hepatic metastases secondary to colorectal adenocarcinoma. In general, the prescribed activity is based on empirical data collected during clinical trials. The activity of the source vial is labeled by the manufacturer as 3.0 GBq{+-}10% and is not independently verified by the end user. This technical note shows that the results of a nondestructive spectroscopic assay of a SIR-Spheressample was 26% higher than the activity stated by the manufacturer. This difference should not impact the current empirical prescription method but may be problematic for patient-specific dosimetry applications, such as image-based dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Note: Modeling a complex micro-multileaf collimator using the standard BEAMnrc distribution

Purpose: The component modules in the standard BEAMnrc distribution may appear to be insufficient to model micro-multileaf collimators that have trifaceted leaf ends and complex leaf profiles. This note indicates, however, that accurate Monte Carlo simulations of radiotherapy beams defined by a complex collimation device can be completed using BEAMnrc's standard VARMLC component module. Methods: That this simple collimator model can produce spatially and dosimetrically accurate microcollimated fields is illustrated using comparisons with ion chamber and film measurements of the dose deposited by square and irregular fields incident on planar, homogeneous water phantoms. Results: Monte Carlo dose calculations for on-axis and off-axis fields are shown to produce good agreement with experimental values, even on close examination of the penumbrae. Conclusions: The use of a VARMLC model of the micro-multileaf collimator, along with a commissioned model of the associated linear accelerator, is therefore recommended as an alternative to the development or use of in-house or third-party component modules for simulating stereotactic radiotherapy and radiosurgery treatments. Simulation parameters for the VARMLC model are provided which should allow other researchers to adapt and use this model to study clinical stereotactic radiotherapy treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Note: Experimental determination of the effective point of measurement of two cylindrical ionization chambers in a clinical proton beam

Purpose: IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement of 0.75 times the inner cavity radius (0.75R) for heavy ion beams. Theoretical models by Palmans and by Bhullar and Watchman confirmed this value. However, the experimental results vary from author to author. The purpose of this study is to accurately measure the displacement and explain the past experimental discrepancies. Methods: In this work, we measured the EPOM of cylindrical ionization chambers with high accuracy by comparing the Bragg-peak position obtained with cylindrical ionization chambers (PTW 30013, PTW 31016) to that obtained using a plane-parallel ionization chamber (PTW 34045). Results: The EPOMs of PTW 30013 and 31016 were shifted by 0.92 ± 0.07 R with R = 3.05 mm and 0.90 ± 0.14 R with R = 1.45 mm, respectively, from the reference point toward the source. Conclusions: The EPOMs obtained were greater than the value of 0.75R proposed by the IAEA TRS-398 and the analytical results.

07 ISOTOPE AND RADIATION SOURCES↗

Technical Note: Phantom study to evaluate the dose and image quality effects of a computed tomography organ-based tube current modulation technique

Purpose: This technical note quantifies the dose and image quality performance of a clinically available organ-dose-based tube current modulation (ODM) technique, using experimental and simulation phantom studies. The investigated ODM implementation reduces the tube current for the anterior source positions, without increasing current for posterior positions, although such an approach was also evaluated for comparison. Methods: Axial CT scans at 120 kV were performed on head and chest phantoms on an ODM-equipped scanner (Optima CT660, GE Healthcare, Chalfont St. Giles, England). Dosimeters quantified dose to breast, lung, heart, spine, eye lens, and brain regions for ODM and 3D-modulation (SmartmA) settings. Monte Carlo simulations, validated with experimental data, were performed on 28 voxelized head phantoms and 10 chest phantoms to quantify organ dose and noise standard deviation. The dose and noise effects of increasing the posterior tube current were also investigated. Results: ODM reduced the dose for all experimental dosimeters with respect to SmartmA, with average dose reductions across dosimeters of 31% (breast), 21% (lung), 24% (heart), 6% (spine), 19% (eye lens), and 11% (brain), with similar results for the simulation validation study. In the phantom library study, the average dose reduction across all phantoms was 34% (breast), 20% (lung), 8% (spine), 20% (eye lens), and 8% (brain). ODM increased the noise standard deviation in reconstructed images by 6%–20%, with generally greater noise increases in anterior regions. Increasing the posterior tube current provided similar dose reduction as ODM for breast and eye lens, increased dose to the spine, with noise effects ranging from 2% noise reduction to 16% noise increase. At noise equal to SmartmA, ODM increased the estimated effective dose by 4% and 8% for chest and head scans, respectively. Increasing the posterior tube current further increased the effective dose by 15% (chest) and 18% (head) relative to SmartmA. Conclusions: ODM reduced dose in all experimental and simulation studies over a range of phantoms, while increasing noise. The results suggest a net dose/noise benefit for breast and eye lens for all studied phantoms, negligible lung dose effects for two phantoms, increased lung dose and/or noise for eight phantoms, and increased dose and/or noise for brain and spine for all studied phantoms compared to the reference protocol.

60 APPLIED LIFE SCIENCES↗

Technical Note: Statistical dependences between channels in radiochromic film readings. Implications in multichannel dosimetry

Purpose: This note studies the statistical relationships between color channels in radiochromic film readings with flatbed scanners. The same relationships are studied for noise. Finally, their implications for multichannel film dosimetry are discussed. Methods: Radiochromic films exposed to wedged fields of 6 MV energy were read in a flatbed scanner. The joint histograms of pairs of color channels were used to obtain the joint and conditional probability density functions between channels. Then, the conditional expectations and variances of one channel given another channel were obtained. Noise was extracted from film readings by means of a multiresolution analysis. Two different dose ranges were analyzed, the first one ranging from 112 to 473 cGy and the second one from 52 to 1290 cGy. Results: For the smallest dose range, the conditional expectations of one channel given another channel can be approximated by linear functions, while the conditional variances are fairly constant. The slopes of the linear relationships between channels can be used to simplify the expression that estimates the dose by means of the multichannel method. The slopes of the linear relationships between each channel and the red one can also be interpreted as weights in the final contribution to dose estimation. However, for the largest dose range, the conditional expectations of one channel given another channel are no longer linear functions. Finally, noises in different channels were found to correlate weakly. Conclusions: Signals present in different channels of radiochromic film readings show a strong statistical dependence. By contrast, noise correlates weakly between channels. For the smallest dose range analyzed, the linear behavior between the conditional expectation of one channel given another channel can be used to simplify calculations in multichannel film dosimetry.

60 APPLIED LIFE SCIENCES↗

Technical Note: Introduction of variance component analysis to setup error analysis in radiotherapy

Purpose: The purpose of this technical note is to introduce variance component analysis to the estimation of systematic and random components in setup error of radiotherapy. Methods: Balanced data according to the one-factor random effect model were assumed. Results: Analysis-of-variance (ANOVA)-based computation was applied to estimate the values and their confidence intervals (CIs) for systematic and random errors and the population mean of setup errors. The conventional method overestimates systematic error, especially in hypofractionated settings. The CI for systematic error becomes much wider than that for random error. The ANOVA-based estimation can be extended to a multifactor model considering multiple causes of setup errors (e.g., interpatient, interfraction, and intrafraction). Conclusions: Variance component analysis may lead to novel applications to setup error analysis in radiotherapy.

60 APPLIED LIFE SCIENCES↗

LHC EFT WG note: Basis for anomalous quartic gauge couplings

In this note, we give a definitive basis for the dimension-eight operators leading to quartic—but no cubic—interactions among electroweak gauge bosons. These are often called anomalous quartic gauge couplings, or aQGCs. We distinguish in particular the CP-even ones from their CP-odd counterparts.

Durieux, Gauthier (ORCID:0000000172726490)↗

Application note :

The development of the XyceTM Parallel Electronic Simulator has focused entirely on the creation of a fast, scalable simulation tool, and has not included any schematic capture or data visualization tools. This application note will describe how to use the open source schematic capture tool gschem and its associated netlist creation tool gnetlist to create basic circuit designs for Xyce, and how to access advanced features of Xyce that are not directly supported by either gschem or gnetlist.

Russo, Thomas V.↗

NESM TAG Meeting Notes

March 2015 NESM TAG Notes related to 1) Structure surface representation, 2) Structure-fluid coupling algorithm, 3) Coupled time integration scheme, 4) Coupling data exchange API, 5) Portability across platforms and builds, and 6) Testing and verification.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗