Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Neutronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Background and Lunar Neutron Populations Detected by LEND and Average Concentration of Near-Surface Hydrogen near the Moon's Poles

Neutron flux measurements by the Lunar Exploration Neutron Detector (LEND) on the Lunar Reconnaissance Orbiter (LRO) enable quantifying hydrogen-bearing volatiles in the lunar surface from orbit. Accurately determining hydrogen abundance requires discriminating between the instrument background detection rate and the population of lunar-sourced neutrons that are sensitive to surficial hydrogen. We have investigated the detection rate for lunar and non-lunar (spacecraft-sourced) neutrons in LEND by modeling maps of measured count rate in three LEND detector systems using linear combinations of maps compiled from LEND detectors and from the Lunar Prospector Neutron Spectrometer. We find that 30% of the global-average 24.926 +/- 0.020 neutron counts per second (cps) detected by the LEND STN3 thermal-energy neutron sensor are lunar-sourced neutrons in the thermal energy range (E < 0.4 eV), 65% are lunar-sourced neutrons in the epithermal and fast energy range (E > 0.4 eV), and 5% are from spacecraft-sourced background signal. In the SETN epithermal neutron detector, 90% of the 10.622 +/- 0.002 neutron detections per second are consistent with a lunar source of epithermal and fast neutrons combined (E > 0.4 eV), with 3% due to lunar-sourced thermal neutron leakage into the detector (E < 0.4 eV), and background signal accounting for 7% of total detections. Background signal due to spacecraft-derived neutrons is substantial in the CSETN collimated detector system, accounting for 57% of the global average detection rate of 5.082 +/- 0.001 cps, greater than the 48% estimated from cruise-phase data. Lunar-sourced epithermal and fast neutrons account for 43% of detected neutrons, including neutrons in collimation as well as neutrons that penetrate the collimator wall to reach the detector. We estimate a lower limit of 17% of lunar-sourced neutrons detected by CSETN are epithermal neutrons in collimation (0.37 cps), with an upper limit estimate of 54 +/- 11% of lunar-sourced neutrons received in collimation, or 1.2 +/- 0.2 cps global average. The pole-to-equator contrast ratio in epithermal and high-energy epithermal neutron flux indicates that the average concentration of hydrogen in the polar regolith above 80deg north or south latitude is ∼105 ppmw (parts per million by weight), or 0.095 +/- 0.01 wt% water-equivalent hydrogen. Above 88deg north or south, the concentration increases to ∼140 ppmw, or 0.13 +/- 0.02 wt% water-equivalent hydrogen. The similar pattern of neutron flux suppression at both poles suggests that hydrogen concentration generally increases nearer the pole and is not closely associated with a specific feature such as Shackleton Crater at the lunar south pole that has no northern counterpart. Epithermal neutron flux decreases with increasing latitude outside the polar regions, consistent with surface hydration that increases with latitude if that hydration extends to ∼13-40 cm into the surface.

T A Livengood

Background and Lunar Neutron Populations Detected by LEND and Average Concentration of Near-Surface Hydrogen near the Moon's Poles

Neutron flux measurements by the Lunar Exploration Neutron Detector (LEND) on the Lunar Reconnaissance Orbiter (LRO) enable quantifying hydrogen-bearing volatiles in the lunar surface from orbit. Accurately determining hydrogen abundance requires discriminating between the instrument background detection rate and the population of lunar-sourced neutrons that are sensitive to surficial hydrogen. We have investigated the detection rate for lunar and non-lunar (spacecraft-sourced) neutrons in LEND by modeling maps of measured count rate in three LEND detector systems using linear combinations of maps compiled from LEND detectors and from the Lunar Prospector Neutron Spectrometer. We find that 30% of the global-average 24.926 0.020 neutron counts per second (cps) detected by the LEND STN3 thermal-energy neutron sensor are lunar-sourced neutrons in the thermal energy range (E < 0.4 eV), 65% are lunar-sourced neutrons in the epithermal and fast energy range (E > 0.4 eV), and 5% are from spacecraft-sourced background signal. In the SETN epithermal neutron detector, 90% of the 10.622 0.002 neutron detections per second are consistent with a lunar source of epithermal and fast neutrons combined (E > 0.4 eV), with 3% due to lunar-sourced thermal neutron leakage into the detector (E < 0.4 eV), and background signal accounting for 7% of total detections. Background signal due to spacecraft-derived neutrons is substantial in the CSETN collimated detector system, accounting for 57% of the global average detection rate of 5.082 0.001 cps, greater than the 48% estimated from cruise-phase data. Lunar-sourced epithermal and fast neutrons account for 43% of detected neutrons, including neutrons in collimation as well as neutrons that penetrate the collimator wall to reach the detector. We estimate a lower limit of 17% of lunar-sourced neutrons detected by CSETN are epithermal neutrons in collimation (0.37 cps), with an upper limit estimate of 54 11% of lunar-sourced neutrons received in collimation, or 1.2 0.2 cps global average. The pole-to-equator contrast ratio inepithermal and high-energy epithermal neutron flux indicates that the average concentration of hydrogen in the polar regolith above 80 north or south latitude is ~105 ppmw (parts per million by weight), or 0.095 0.01 wt% water-equivalent hydrogen. Above 88 north or south, the concentration increases to ~140 ppmw, or 0.13 0.02 wt% water-equivalent hydrogen. The similar pattern of neutron flux suppression at both poles suggests that hydrogen concentration generally increases nearer the pole and is not closely associated with a specific feature such as Shackleton Crater at the lunar south pole that has no northern counterpart. Epithermal neutron flux decreases with increasing latitude outside the polar regions, consistent with surface hydration that increases with latitude if that hydration extends to ~13-40 cm into the surface.

Livengood, Timothy A.

Neutrons in Structural Biology: Challenges and Opportunities (Workshop Report)

Gaining a thorough understanding of biological systems requires building our knowledge about biological processes from the level of atoms and electrons, and up to whole organisms. Such comprehensive knowledge will allow for a predictive understanding of complex biological systems behavior. It will guide us in the design and development of novel therapeutics and vaccines to tackle existing health threats and to prepare for future pandemics, and it will provide information necessary to create new biomaterials and bio-inspired technologies through manipulation of biological macromolecules, their assemblies, single cells and even microorganisms. Reaching these goals will require a synergistic combination of multiple experimental techniques with molecular calculations and predictive simulations, and the design and development of new techniques and capabilities that bridge current knowledge and technology gaps. Neutron scattering provides unique information about the biomacromolecular structure and function and can play a major role in achieving these goals. A workshop was held to engage the scientific community in identifying pressing challenges in biochemistry, structural biology, enzymology and structure-guided drug design not solved with the current neutron scattering technologies or utilizing other structural biology techniques such as X-ray crystallography, NMR, and cryo-EM. The workshop brought together structural biology, biochemistry and computational experts, as well as early career researchers and students, creating a forum for discussing scientific advancement and collaboration. The workshop included a one-day satellite training workshop where graduate students and postdoctoral researchers were educated in the application of neutron crystallography and small-angle scattering in structural biology. Furthermore, the Instrument Scientific Advisory Board (ISAB) for the development of a macromolecular neutron diffractometer at ORNL’s Second Target Station was introduced at the workshop. The major outcome was that neutrons can provide atomic-level understanding of biomacromolecular structure, function and dynamics which is of paramount importance for addressing the identified challenges. Neutron crystallography, in particular, can resolve long-standing biochemical issues regarding enzyme function by delineating the underlying chemistry and can have a major impact on the design of small-molecule therapeutics, especially in combination with molecular computation (quantum chemistry and molecular dynamics simulations) and the emerging artificial intelligence (AI)-assisted drug design technologies. The unique properties of neutrons, including their high sensitivity to hydrogen and their non-destructive nature, make them ideal probes of biological matter. There is a palpable need in the scientific community to expand and enhance the impact of neutron sciences on biology. Neutron crystallography is the only structural biology method capable of determining positions of all hydrogen atoms in proteins, nucleic acids and their complexes at near-physiological temperatures and of unstable species at cryogenic temperatures. Moreover, neutron analysis is non-ionizing, non-destructive and does not perturb the structure or redox chemistry of active site metal centers and clusters in proteins, which can be invaluable for studying radiation-sensitive metalloprotein complexes. Further, neutron energies used in scattering applications are similar to atomic motions, permitting neutron spectroscopies to characterize the dynamics of biomacromolecules on the picosecond to microsecond timescales. The different sensitivities of neutrons to protium (H) and deuterium (D) isotopes of hydrogen allow enhanced visibility of specific parts of biological complexes through isotopic labeling. The impact of neutrons will be most powerful when neutron scattering is combined with complementary experimental techniques that use photons and electrons, and with high-performance computing. The interconnection and mutuality of the experimental and theoretical capabilities will drive discoveries in biological and health sciences to generate more complete picture of complex biological systems. The major limitation in the field of biological neutron crystallography has been signal-to-noise, demanding large samples that are difficult to produce for the majority of biomacromolecules and limiting the applicability of this technique in biological sciences. A neutron crystallography instrument at the Second Target Station will revolutionize biological science with neutrons by engaging a large scientific community of structural biologists, enabling successful neutron diffraction experiments from radically smaller biomacromolecular crystals, resolving unanswered biochemical questions, and meaningfully contributing to rational drug design. The meeting highlighted 10 grand challenges that will be addressed with this advanced capability over the next decade and beyond, and the recommendations required to help address them are given below.

59 BASIC BIOLOGICAL SCIENCES

Conceptual Design of a Thermal–to-14-MeV Neutron Conversion Device for Use in the Advanced Test Reactor

Here, this paper details the conceptual design of a thermal-to-14-MeV neutron converter consisting of a mixture of lithium and deuterium in a blanket material. Such a device operates a two-step reaction, first generating tritons via thermal neutron absorption in the tritium breeding material, and in the second step, high-energy neutrons are produced either via deuterium-tritium fusion reaction or with tritium reacting with lithium. A thermal-to-14-MeV neutron converter significantly hardens the neutron spectrum by virtually removing thermal neutrons and adding a high-energy 14 MeV component to the neutron spectrum. While similar concepts have been previously proposed and tested in other reactors, the unique characteristics of the Advanced Test Reactor (ATR), namely its important thermal flux (up to $10^{15}$ n.cm$^{-2}$.s$^{-1}$) makes it markedly attractive for obtaining a very large fast neutron flux, usable for irradiation studies under neutron flux conditions prototypical of fusion reactors. The paper provides a description of a new computational scheme developed for handling the coupled neutron-triton transport mechanism using the Geant4 toolkit. Resulting neutron spectra and high-energy neutron yields are summarized for different irradiation positions and potential neutron breeder materials. Maximum predicted thermal-to-14-MeV neutron yields are on the order of $2.10^{-4}$, which is consistent with previous studies found in the literature. Thus, when placed inside the ATR, such a neutron converter will be providing the largest high-energy neutron source available for activation and irradiation studies of materials foreseen for use in fusion reactors. Future steps will involve qualifying the computational scheme using the ATR critical facility using activation foil measurements.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Ultrawide bandgap semiconductor h-BN for direct detection of fast neutrons

III-nitride wide bandgap semiconductors have contributed on the grandest scale to many technological advances in lighting, displays, and power electronics. Among III-nitrides, BN has another unique application as a solid-state neutron detector material because the isotope B-10 is among a few elements that have an unusually large interaction cross section with thermal neutrons. A record high thermal neutron detection efficiency of 60% has been achieved by B-10 enriched h-BN detectors of 100 μm in thickness in our group. However, direct detection of fast neutrons with energies above 1 MeV is highly challenging due to the extremely low interaction cross section of fast neutrons with matter. We report the successful attainment of 0.4 mm thick freestanding h-BN 4"-diameter wafers, which enabled the demonstration of h-BN fast neutron detectors capable of delivering a detection efficiency of 2.2% in response to a bare AmBe neutron source. Furthermore, it was shown that the energy information of incoming fast neutrons is retained in the neutron pulse-height spectra. A comparison of characteristics between h-BN fast and thermal neutron detectors is summarized. Neutron detectors are vital diagnostic instruments for nuclear and fusion reactor power and safety monitoring, oil field exploration, neutron imaging and therapy, as well as for plasma and material science research. With the outstanding attributes resulting from its ultrawide bandgap (UWBG), including the ability to operate at extreme conditions of high power, voltage, and temperature, the availability of h-BN UWBG semiconductor detectors with the capability of simultaneously detecting thermal and fast neutrons with high efficiencies is expected to open unprecedented applications that are not possible to attain by any other types of neutron detectors.

36 MATERIALS SCIENCE

Fusion Neutron Generator

The proposed code, named FROG (Fusion neutron Generator) is built upon the open-source particle transport Monte Carlo toolkit Geant4. Geant4 provides C++ classes that can be leveraged to build application-specific codes dealing with the transport of particles through matter. Geant4-based codes are applied in high-energy particle physics experiments, medical applications, shielding, and space applications for example. The FROG code allows the user to define the geometry of a neutron converter device shaped as a hollow cylinder, where a neutron breeding material such as lithium deuteride (LiD) is cladded by two concentric cylinders. Such neutron converter is then placed inside a regular nuclear fission reactor, where thermal neutrons will react with the neutron breeder material (typically, Lithium 6), and through a series of reactions, will generate high-energy neutrons – neutrons whose kinetic energy are around 14 MeV. The hollowed central portion can hold a specimen that will be bombarded by high-energy neutrons created inside the neutron breeding material. Figuratively speaking, this type of device transforms neutrons from thermal (~0.625 eV) to fusion (~14 MeV) energies and is sometimes termed “fusion-to-thermal neutron converters” in the literature. The code consists of C++ source file compiled and linked to generate an executable. The user can select the dimensions of the converter (radius, length, and thickness of the breeder material), the breeder material type, the cladding material, and the specimen material that will be activated or irradiated. As input, the neutron flux for a specific location inside a reactor, for instance, positions in ATR, is required. As output, the code predicts the number of high-energy neutrons produced, the total neutron flux and fluence as well as its detailed spectrum. The physics involved in such device is very complex, as it requires modeling neutron transport, light-ion (tritons) transport, as well as fusion reactions. The Geant4 toolkit provides the required physical models.

Martin, NicholasP. [Idaho National Laboratory (INL

Investigating Gadolinium-Lined Sodium-Iodide Neutron Detectors for Mobile Applications

For enhancing the effectiveness of nonproliferation efforts in neutron detection, most portable instruments rely on 6 Li scintillators, 10 B-based detectors, or gas-filled 3 He proportional counters. Additionally, gamma-ray detectors based on scintillators and semiconductors are often employed for search applications to find radioactive material in the field. These systems typically include dedicated detectors along with separate high voltage supplies and processing electronics for the gamma-ray and neutron detectors. Ideally, a portable radiation detection system should be lightweight, compact, and cost-effective. In the field, scintillators can serve a dual purpose: (1) detecting gamma-rays and (2) detecting neutrons. Gamma-ray detection with scintillators is based on the interaction of gamma-rays within the scintillating material, whereas neutron detection depends indirectly on neutron capture events. These capture events generate conversion electrons and gamma-rays, which can interact with the scintillator. For enhancing neutron capture, the scintillator can be surrounded by neutron absorber materials with a high neutron cross section. The resulting secondary electrons and gamma-rays from neutron interactions, depending on the absorber material used, can then be analyzed to detect the presence of neutron sources. Similarly, semiconductor-based detectors can be employed along with neutron absorbers as liners for neutron detection. 158 Gd has a significantly larger neutron cross section than 3 He, commonly used in gas-filled proportional counters, as shown in Figure 1. For thermal (0.025 eV) neutrons, the absorption cross section of 158 Gd is 10,000 times greater than that of 3 He (refer to Figure 1). This feature makes naturally occurring gadolinium, which consists of 24.8% 158 Gd, a promising neutron absorber material for use in combination with gamma-ray detectors–yielding a hybrid detector–for neutron detection.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P

Neutron dosimetry in low-earth orbit using passive detectors

This paper summarizes neutron dosimetry measurements made by the USF Physics Research Laboratory aboard US and Russian LEO spacecraft over the past 20 years using two types of passive detector. Thermal/resonance neutron detectors exploiting the 6Li(n,T) alpha reaction were used to measure neutrons of energies <1 MeV. Fission foil neutron detectors were used to measure neutrons of energies above 1 MeV. While originally analysed in terms of dose equivalent using the NCRP-38 definition of quality factor, for the purposes of this paper the measured neutron data have been reanalyzed and are presented in terms of ambient dose equivalent. Dose equivalent rate for neutrons <1 MeV ranged from 0.80 microSv/d on the low altitude, low inclination STS-41B mission to 22.0 microSv/d measured in the Shuttle's cargo bay on the highly inclined STS-51F Spacelab-2 mission. In one particular instance a detector embedded within a large hydrogenous mass on STS-61 (in the ECT experiment) measured 34.6 microSv/d. Dose equivalent rate measurements of neutrons >1 MeV ranged from 4.5 microSv/d on the low altitude STS-3 mission to 172 microSv/d on the ~6 year LDEF mission. Thermal neutrons (<0.3 eV) were observed to make a negligible contribution to neutron dose equivalent in all cases. The major fraction of neutron dose equivalent was found to be from neutrons >1 MeV and, on LDEF, neutrons >1 MeV are responsible for over 98% of the total neutron dose equivalent. Estimates of the neutron contribution to the total dose equivalent are somewhat lower than model estimates, ranging from 5.7% at a location under low shielding on LDEF to 18.4% on the highly inclined (82.3 degrees) Biocosmos-2044 mission. c2001 Elsevier Science Ltd. All rights reserved.

Flight Experiment

Evaluation of neutron dosimetry capabilities with the MC-15 portable multiplicity counter

This work proposes a preliminary neutron dose rate estimation method for a neutron multiplicity detector through measurement- and simulation-based analyses. Uncharacterized neutron-emitting sources may be encountered in situations such as nuclear emergency response, safeguards, and treaty verification. These circumstances may present irradiation risk to personnel conducting field assay, search, and characterization measurements. It is therefore of interest to provide a field neutron dosimetry capability with the existing neutron multiplicity counting (NMC) capabilities. To date, no commercially-available neutron detection systems are capable of both accurate NMC and real-time neutron dosimetry. This work will focus on estimating dose rate using input from a single fielded NMC called the MC-15. The energy-dependent neutron detection efficiency response of the MC-15 was quantified in monoenergetic neutron simulations and evaluated in response to two neutron-emitting sources and to a polyethylene-moderated source. The results were compared to existing neutron dosimeters and established the proof of concept for further investigation of the MC-15 for dose estimation. Measurement results were also replicated in simulations; additional simulations were then conducted to expand upon the limited empirical data. The initial empirical results provided a conversion factor appropriate for use when measuring 252 Cf neutrons that is independent of polyethylene shielding presence and thickness. The simulated data sets were then used to evaluate a fit equation allowing estimation of the neutron dose rate for less restricted geometric configurations and dependent only on the distance between the source and the detector. Additionally, the energy dependence of the efficiency response indicates that further empirical evaluations could provide energy-dependent conversion factors for broader neutron dosimetry capabilities with a wider range of neutron-emitting sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Polyvinyl Alcohol and Medium Density Polyethylene Composite Materials for Neutron Radiation Shielding

Manned spacecraft venturing beyond the Earth’s Van Allen Belts will be subjected to high levels of radiation from both energetic particles emanating from the sun and from galactic atomic events, such as supernovae. The metal shell of a spacecraft offers some protection from gamma radiation and high energy particles originating from both the sun and cosmic sources. The interaction of these high energy particles and radiation with the spacecraft hull create secondary radiation and neutrons, additional hazards for astronauts and electronic systems. Shielding of neutrons is the most challenging of the high energy radiation, since neutrons have zero charge and are least affected by electrical fields, magnetic fields, and atomic forces. Previous studies showed that polyethylene is an effective neutron shielding material, due to its high hydrogen content. High energy neutrons are slowed to thermal neutrons through multiple collisions with the hydrogen atoms, increasing the effectiveness of neutron capture by boron-10 atoms. This study discusses the fabrication and testing of polyvinyl alcohol (PVOH) samples as a neutron shielding material, with comparison to medium density polyethylene (MDPE) composite samples to be used for neutron shielding for spacecraft. PVOH, an aqueous polymer, was chosen for hydrogen content and for enabling the use of organic reinforcement such as cellulose for secondary structural composites. OLTARIS (On-Line Tool for the Assessment of Radiation in Space) was used for radiation shielding simulation and compared with experimental data. Modeling indicates that the most effective shielding from radiation was in an aluminum layer backed by a polymer layer, either MDPE or PVOH. Cross-linked PVOH was also included in the OLTARIS modeling. All 3 polymer cases showed shielding improvement over aluminum alone, with similar dose equivalent reduction for galactic cosmic radiation(GCR)and for radiation from a solar particle event (SPE). Fourier Transform Infrared (FTIR) Spectroscopy was used to confirm the cross-linking in the PVOH sample and to determine the uniformity through the thickness. PVOH, cross-linked PVOH, and MDPE samples were tested for neutron shielding effectiveness using a 1 curie Americium-Beryllium neutron source. Test results indicated the most shielding in the cross-linked PVOH, followed by the pristine PVOH, and MDPE. Neutron testing suggests that polyvinyl alcohol is a good alternative to polyethylene for neutron shielding. The neutron shielding materials, PVOH and cross-linked PVOH developed under this research will enable the safe operation of spacecraft beyond the Earth’s protective Van Allen Radiation Belts. It will be crucial for NASA’s manned missions to the Moon or Mars to protect the health of astronauts and equipment from the harmful effects of excessive radiation.

neutron, shielding, radiation, polyvinyl alcohol,