Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron generators.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Neutron Generator Driven Active Nuclear Fuel Scanner

Non-Destructive Assay has long been used for active scanning of nuclear fuel. In this method, fuel rods traverse through a scanner with an activation zone in which they are subjected to neutron radiation and fission activity is subsequently measured as the rods exit the irradiator. From this and other information, the enrichment and other characteristics of each rod and pellet are determined. Californium-252 has traditionally been used as the neutron source in the activation zone, because it is an intense neutron emitter and is readily packaged in compact, portable capsules. However, a recent shift to a full cost-recovery basis for Cf-252 has led to a more than 10 times increase in cost. This increase in cost is forcing some Cf- 252 users to seek alternate neutron sources, including nuclear fuel manufacturers. Phoenix Nuclear Labs has developed a high-flux, accelerator-based neutron source that is a viable alternative for applications requiring large Cf-252 sources - on the milligram-scale or larger - such as neutron radiography, nuclear fuel rod scanning, and neutron flux detector calibration. Neutron flux modeling and expected fission rates for the complete active scanning system based on the PNL neutron generator will be presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sealed operation of a rf driven ion source for a compact neutron generator to be used for associated particle imaging

We present the recent development of a prototype compact neutron generator to be used in conjunction with the method of associated particle imaging for the purpose of active neutron interrogation. In this paper, the performance and device specifications of these compact generators that employ rf driven ion sources will be discussed. Initial measurements of the generator performance include a beam spot size of 1 mm in diameter and a neutron yield of 2x10{sup 5} n/s with air cooling.

43 PARTICLE ACCELERATORS↗

Compact deuterium-tritium neutron generator using a novel field ionization source

Active interrogation using neutrons is an effective method for detecting shielded nuclear material. A lightweight, lunch-box-sized, battery-operated neutron source would enable new concepts of operation in the field. We have developed at-scale components for a highly portable, completely self-contained, pulsed Deuterium-Tritium (DT) neutron source producing 14 MeV neutrons with average yields of 10{sup 7} n/s. A gated, field ionization ion source using etched electrodes has been developed that produces pulsed ion currents up to 500 nA. A compact Cockcroft-Walton high voltage source is used to accelerate deuterons into a metal hydride target for neutron production. The results of full scale DT tests using the field ionization source are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Cargo Inspection System for Special Nuclear Material (SNM) Based on Associated Particle Neutron Generators and Liquid-Kr Detectors

A feasibility analysis is presented of a cargo inspection system based on neutron-induced fission followed by the coincident detection of multiple prompt fission gamma rays as a signature of Special Nuclear Material (SNM). The system does not require gamma ray spectroscopy and would be capable of distinguishing U-238 from U-235 using the ratio of signals from two modes of detection: thermal neutron capture induced fission and fast neutron-induced fission. The system utilizes two deuterium-tritium (DT) associated particle neutron generators, each capable of 10{sup 9} neutrons/s at 14.1 MeV, with sub-nanosecond timing resolution ZnO:Ga alpha detectors. The expected {approx}1 MeV prompt gamma rays are detected using liquid krypton (LKr) detectors with sub-nanosecond timing resolution ({approx}600 ps) and high detection efficiency. The expected SNM signal and randomly correlated background rates are discussed using Monte Carlo N-Particle (MCNP) code.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Differential Die-Away Instrument: Report on Fuel Assembly Mock-up Measurements with Neutron Generator

Fresh fuel experiments for the differential die-away (DDA) project were performed using a DT neutron generator, a 15x15 PWR fuel assembly, and nine 3 He detectors in a water tank inside of a shielded cell at Los Alamos National Laboratory (LANL). Eight different fuel enrichments were created using low enriched (LEU) and depleted uranium (DU) dioxide fuel rods. A list-mode data acquisition system recorded the time-dependent signal and analysis of the DDA signal die-away time was performed. The die-away time depended on the amount of fissile material in the fuel assembly and the position of the detector. These experiments were performed in support of the spent nuclear fuel Next Generation Safeguards Initiative DDA project. Lessons learned from the fresh fuel DDA instrument experiments and simulations will provide useful information to the spent fuel project.

07 ISOTOPE AND RADIATION SOURCES↗

Active Interrogation Using Electronic Neutron Generators for Nuclear Safeguards Applications

Active interrogation, a measurement technique which uses a radiation source to probe materials and generate unique signatures useful for characterizing those materials, is a powerful tool for assaying special nuclear material. The most commonly used technique for performing active interrogation is to use an electronic neutron generator as the probe radiation source. Exploiting the unique operating characteristics of these devices, including their monoenergetic neutron emissions and their ability to operate in pulsed modes, presents a number of options for performing prompt and delayed signature analyses using both photon and neutron sensors. A review of literature in this area shows multiple applications of the active neutron interrogation technique for performing nuclear nonproliferation measurements. Some examples include measuring the plutonium content of spent fuel, assaying plutonium residue in spent fuel hull claddings, assaying plutonium in aqueous fuel reprocessing process streams, and assaying nuclear fuel reprocessing facility waste streams to detect and quantify fissile material. This paper discusses the historical use of this technique and examines its context within the scope and challenges of next-generation nuclear fuel cycles and advanced concept nuclear fuel cycle facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a Thermo Scientific D711 D-T neutron generator located in a low-scatter facility

A dosimetry experiment used to measure the neutron flux and spectrum of a D-T neutron generator is presented. The D-T generator at Pacific Northwest National Laboratory is installed in the middle of a large room to minimize scatter of neutrons back to the sample. The efficacy of maintaining a pure fast neutron field for the sample is investigated. Twenty-one positions within 13 cm of the neutron source contained foils or wires of Fe, Ni, Al with additional Au, and In monitors at some locations. Spectral adjustment of the neutron flux at each position based on measured reaction rates and theoretical Monte Carlo calculations show that at least 99.1% of the spectrum lies above 110 keV for all measured positions, and neutrons above 14 MeV can account for as much as 91% at locations along the axis of the generator and close to the source. The 14 MeV component drops to 77% in radial positions far from the source. The largest total flux observed was 8.29E+08 n/cm2-s (±1.4%) in the center of the cooling cap, although additional experiments have shown this value could be as high as 1.20E+09 n/cm2-s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A field evaporation deuterium ion source for neutron generators

Proof-of-principle experiments have demonstrated an electrostatic field evaporation based deuterium ion source for use in compact, high-output deuterium-tritium neutron generators. The ion source produces principally atomic deuterium and titanium ions. More than 100 ML of deuterated titanium thin film can be removed and ionized from a single tip in less than 20 ns. The measurements indicate that with the use of microfabricated tip arrays the deuterium ion source could provide sufficient ion current to produce 10{sup 9}-10{sup 10} n/cm{sup 2} of tip array area.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of compact size penning ion source for compact neutron generator

For long-life operation, easy to mount and compact in size penning type ion sources are widely used in different fields of research such as neutron generators, material research, and surface etching. One penning type ion source has been developed in our laboratory. Applying high voltage of 2 kV between two oppositely biased electrodes and using permanent magnet of 500 gauss magnetic field along the axis, we had produced the glow discharge in the plasma region. The performance of this source was investigated using nitrogen gas. Deuterium ions were produced and extracted on the basis of chosen electrodes and the angle of extraction. Using a single aperture plasma electrode, the beam was extracted along the axial direction. The geometry of plasma electrode is an important factor for the efficient extraction of the ions from the plasma ion source. The extracted ion current depends upon the shape of the plasma meniscus. A concave shaped plasma meniscus produces converged ion beam. The convergence of extracted ions is related to the extraction electrode angle. The greater the angle, the more the beam converges. We had studied experimentally this effect with a compact size penning ion source. The detailed comparison among the different extraction geometry and different electrode angle are discussed in this paper.

43 PARTICLE ACCELERATORS↗

Miniature Neutron Generator for Brachytherapy Tumor Treatment

This project will develop and commercialize a small, portable, low cost, deuterium- tritium (DT) neutron generator for treatment of cancer by fast-neutron brachytherapy (FNT). Since the instrument will be portable and relatively low in cost, many instruments can be deployed so that cancer patients in areas remote from large radiotherapy treatment centers can be treated more affordably and at their convenience.

99 GENERAL AND MISCELLANEOUS↗

High-yield and high-angular-fluence neutron generation from deuterons accelerated by laser-driven collisionless shock

Since a bright collimated neutron source is an essential tool for global security missions and fundamental scientific research. In this paper, we study a compact high-yield and high-angular-fluence neutron source particularly suitable for high-energy neutron applications utilizing the breakup reaction of laser-driven deuterons in a 9 Be converter. The neutron generation scaling from such a reaction is used to guide the choice and optimization of the acceleration process for bulk ions in a low density CD 2 foam. In particular, the collisionless shock acceleration mechanism is exploited with proper choice in the laser and target parameter space to accelerate these ions toward energies above the temperature of the distribution. Particle-in-cell and Monte Carlo simulations are coupled here to investigate this concept and possible adverse effects as well as the contribution from the surface ions accelerated and the optimal converter design. The simulation results indicated that our design can be a practical approach to increase both the neutron yield and angular fluence of laser-driven neutron sources, reaching >10 11 neutron/pulse (or >10 8 neutron/J) and >10 11 neutron/sr (or >10 8 neutron/sr/J) with present-day kJ-class high-power lasers. Such developments will advance fundamental neutron science, high precision radiography, and other global security applications with laser-driven sources.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Demonstration of an intense lithium beam for forward-directed pulsed neutron generation

Abstract As an alternative to research nuclear reactors, a compact accelerator-driven neutron generator that uses a lithium beam driver could be a promising candidate since it produces almost no undesired radiation. However, providing an intense lithium-ion beam has been difficult, and it has been thought that the practical application of such a device would be impossible. The most critical problem of insufficient ion fluxes has been solved by applying a direct plasma injection scheme. In this scheme, a pulsed high-density plasma from a metallic lithium foil generated by laser ablation is efficiently injected and accelerated by a radio-frequency quadrupole linear accelerator (RFQ linac). We have obtained a peak beam current of 35 mA accelerated to 1.43 MeV, which is two orders of magnitude higher than a conventional injector and accelerator system can deliver.

43 PARTICLE ACCELERATORS↗

Measurements of D–D fusion neutrons generated in nanowire array laser plasma using Timepix3 detector

Here, we present results of the neutron detection in laser plasma experiment with CD2 nanowire target. A hybrid semiconductor pixel detector Timepix3 covered with neutron converters was using for the detection neutrons. D-D fusion neutrons were detected in a plastic converter through recoiled protons. Both the energy of recoiled protons and time-of-flight of neutrons (and thus their energy) were determined. We report (2.4±1.8) × 10 7 neutrons generated for 1 J of incoming laser energy. Furthermore, we proved that Timepix3 is suitable for difficult operational conditions in laser experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

P497 Portable Neutron Generator for Medical Application

The primary goal of this project is the development and construction of a portable neutron generator (PNG), intended for medical use, specifically the treatment of cancer. The device should be portable and should generate approximately 109 n/s. Another important requirement is that the target should be placed at the end of a sealed tube so that neutrons can be delivered easily to the tumor for effective treatment. Since the PNG sealed tube target will be in contact with patient tissue, the power dissipation should be less than 100 watts.

99 GENERAL AND MISCELLANEOUS↗