Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Charge carrier motion and effect of fixed oxide charge in a microstructured silicon radiation detector

Signal formation in a microstructured semiconductor neutron detector is more complex than in planar diode geometry. Three-dimensional microstructures are laterally smaller than the ionization cloud length, and the electric fields may be weak enough to exhibit plasma time effects. This work is the first detailed treatment of charge carrier motion in these complex semiconductor devices to replicate the time profile and signal magnitude. Simulations were performed using COMSOL Multiphysics to investigate various parameters that affect the propagation of the charge cloud. It was observed that the size of the simulated three-dimensional structure had an impact on the induced current pulse, indicating the importance of simulation geometry optimization to accurately simulate charge cloud expansion. COMSOL Multiphysics was used to replicate accurate charge creation profiles using energy deposition information imported from radiation transport codes. A detailed simulation methodology is presented to benchmark preamplifier event pulses along with complexities in modeling the charge carrier motion along the etched microstructured trenches with Si–SiO 2 boundary conditions, including fixed oxide charge and interface trapping.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gallium oxide (Ga2O3) as a radiation detector distinguishing neutrons and gammas

Gallium oxide (Ga2O3) is a promising ultrawide bandgap semiconductor for radiation detection with the potential of integrating electronic and scintillation functions within a single crystal device. This study establishes the scintillation response of β-Ga2O3 gamma irradiation from yttrium-88 (88Y). Then, californium-252 (252Cf) is used as a spontaneous fission source of mixed neutron and gamma radiation field to measure scintillation signals. Pulse shape discrimination and constant fraction discrimination techniques were used to separate neutron and gamma interaction events. Further investigation indicates that the prompt temporal responses of β-Ga2O3 for gammas and neutrons may enable discrimination of the two by prompt pulse fitting methods, focused around the initial peak. For gamma irradiation, we observed a rise time (τr) of 2.1 ns, decay time (τd) of 9.5 ns, and a full width at half maximum (FWHM) of 6.2 ns. For neutrons, it showed a τr of 2.3 ns, a τd of 12.1 ns, 9.4 ns FWHM, and reduced peak intensity. A diamond detector exhibited a more symmetrical τr and τd for both gamma and neutron signals and therefore is less effective at discriminating between the two by this method. This draws attention to β-Ga2O3’s ability to distinguish neutron and gamma particles. These findings showcase Ga2O3’s potential as a next-generation semiconductor for applications in nuclear safety and medical imaging, where precise discrimination between neutron and gamma interactions is essential.

Valdes, D. J. (ORCID:0000000304373720)↗

Probing and controlling oxygen impurity diffusion in h -BN semi-bulk crystals

Combining its unique features of ultrawide bandgap (UWBG) and two-dimensional nature, h-BN has been explored for emerging applications such as deep ultraviolet optoelectronic devices and single photon emitters. One of the unusual applications of h-BN is for solid-state neutron detectors by utilizing the property of high thermal neutron capture cross section of B-10 as well as its UWBG properties. Although a record high detection efficiency of 59% has been attained by h-BN detectors, the understanding/minimization of defects and impurities is still needed to further advance the h-BN material and detector technologies. We report metal organic chemical vapor deposition growth and oxygen (O) impurity diffusion in thick h-BN. The diffusion coefficient (D) of O impurities has been measured via the evolution of an oxygen related emission with the etching depth, providing a value of D of ∼ 2 × 10−13 cm2/s at 1450 °C and supporting the interpretation that oxygen in h-BN is a substitutional donor. A multiple-buffer-layer approach was employed to mitigate to a certain degree the issue of oxygen diffusion from sapphire substrate during growth. It was demonstrated that the performance of h-BN neutron detectors fabricated from the wafer incorporating multiple buffer layers was significantly improved, as manifested by the enhanced thermal neutron detection efficiency. The advancement of the crystal growth technology of h-BN semi-bulk crystals creates applications in optoelectronic and power electronic devices utilizing the UWBG semiconductor properties of h-BN, while high efficiency h-BN neutron detectors have the potential to supplant the traditional He-3 gas detectors in various application areas by offering the obvious advantages of UWBG semiconductor technologies.

Physics↗

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION↗

A parallel-plate avalanche counter for the prompt fission neutron spectrum measurement

Neutrons, gamma’s, and fission fragments are among the prompt fission observables. Their precision measurements are fundamental to advance our understanding of fission and any application of fission. For our programmatic need, the χ matrix, which defines as the outgoing neutron spectrum as a function of incoming neutron energy, is sparsely populated and poorly measured for 233,235,238 U and 239,240 Pu. To improve the quality of those χ matrices, a joint LANLLLNL project was undertaken to measure their prompt fission neutron spectra at the LANSCE/WNR facility using neutron detector arrays and a charged-particle detector for the fission-fragment detection. A typical setup is shown in Fig. 1, where one of neutron detector array with a charged-particle detector is given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Differential neutron spectrum generator and related methods and systems

A neutron spectrum generator is disclosed herein including a neutron source, a scatterer positioned in a direct path between the neutron source and a neutron detector, and a material shell configured to have at least one non-uniform characteristic selected from the group consisting of a material, a thickness, a length, an angle, a layer, and combinations thereof to generate a specific spectrum at the neutron detector that is different than the spectrum of the neutron source. A related method includes measuring a first response generated by a first material shell of a neutron spectrum generator interacting with a neutron source, replacing the first material shell with a second material shell, measuring a second response generated by a second material shell of a neutron spectrum generator interacting with the neutron source, and determining a total fission response by determining a difference between the first response and the second response.

Scates, Wade↗

Experimental demonstration of a data-driven control system for subcritical nuclear facility

Here this paper presents an experimental demonstration of a data-driven control system (DCS) designed for the MIT Graphite Exponential Pile (MGEP). The DCS aims to regulate the neutron flux profile such that symmetry is preserved. Neutron flux perturbations are introduced into the MGEP to test the DCS's capabilities by the movement of an initiating control rod (ICR). To realize this functionality, a control system that relies on an artificial neural network (ANN) was developed, and then demonstrated on the MGEP. A Helium-3 ( 3 He) neutron detector and dual control rods, including their moving mechanisms, were fabricated. The perturbed flux profile was monitored by the moving neutron detector. The prediction accuracy of the neural network (NN) was examined and the DCS response was presented. Our results show that neural network regression model trained by experimental data can achieve a prediction error of less than 2.5 cm with a 95% confidence interval. The demonstration experiment also shows that a perturbation of the ICR can be captured by the control system and flux symmetry can be maintained within 1% after the response of the responding control rod (RCR).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Fuel Motion Monitoring System at TREAT - Current Status and Future Plans

An important component of the United States Nuclear Fuel Safety Transient Testing Program, the Fuel Motion Monitoring System (FMMS) at Idaho National Laboratory's Transient Reactor Test Facility (TREAT) is fast-neutron hodoscope capable of imaging the location, movement, and relocation of nuclear fuel experiments under simulated transient accident conditions. The FMMS was refurbished in parallel with the TREAT restart program starting in 2014, restoring 96-channels of fast-neutron detection. Since returning to operation in 2017 the FMMS has supported many fuel safety experiments supporting accident tolerant fuel development, light-water reactor safety, space thermal nuclear propulsion fuel development, and advanced reactor research and development. In Phase 2 of the FMMS restoration. work is now under way to expand the FMMS' field-of-view by adding an additional 96 channels of fast neutron detectors to the system's hodoscope, along with an expanded data acquisition system and associated transient timing electronics. An overview of the FMSS system and its fast-neutron detectors will be presented along with examples of current FMMS imaging performance and associated information.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Report on Field Test at INL Cask Farm of Single Detector Fast Neutron Spent Fuel Cask Verification System

Detecting diversion of spent fuel elements in dry storage casks is challenging due to the thick shielding used in cask construction. Measurements on top of the cask to map the underlying arrangement of the fuel elements and looking for anomalous changes over time has proven difficult to achieve using gamma rays due to the high scattering and attenuation from the thick steel structure, weakening information on the present or absence of fuel bundles. Simulations and laboratory experiments suggest that the high-energy neutron flux (>200 keV) measured directly above each fuel bundle is sufficient to produce a position map that enables detection of the present or absence of fuel bundles, and therefore diversion of a spent fuel bundle. A single-detector spent-fuel monitoring technique based on this principle was development at the Lawrence Livermore National Laboratory (LLNL). The INL Cask Farm in the INTEC technical area at Idaho National Laboratory (INL) offers the capability to test this technique on an MC-10 storage cask which has a distribution of full and empty fuel positions. An experimental test plan for the single-detector verification system was developed in consultation with INL personnel to be completed in FY2021. Due to travel advisories related to COVID-19, the experimental test plan was adapted to enable INL personnel to carry out the measurements in consultation with LLNL personnel following shipment of the LLNL system to INL. Field test measurements of the single detector verification system were successfully carried out at the INL cask farm on September 7-9, 2021. This document summarizes results of the field test.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Plutonium Mass Uncertainty Assessment Using a Cherenkov-Based Neutron Multiplicity Water Detector

We present a new analysis of the sensitivity of a water Cherenkov-based neutron multiplicity counter for nondestructive assay of trace quantities of 240 Pu. The multiplicity counter [water-based neutron detector (WaND)] contains 1.0 m 3 of water doped with 0.2% gadolinium in the form of a gadolinium salt (0.4% GdCl 3 ). It can be used for testing the presence of trace quantities of 240 Pu within a sample of unknown material by observing the correlated timing behavior of neutron capture candidates in the detector. The new analysis takes advantage of the fact that the detector is comprised almost entirely of a homogeneous medium, which permits the use of a simple model to reproduce the observed neutron capture timing behavior. Finally, the results of this analysis indicate that the detector has an absolute neutron detection efficiency of 23.4 ± 1.1% and is sensitive to a 240 Pu mass as small as 2.3 mg (at 1σ) after a 1-h data acquisition.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Three-dimensional reconstruction of inertial confinement fusion hot-spot plasma from x-ray and nuclear diagnostics on OMEGA

Multidimensional effects degrade the neutron yield and the compressed areal density of laser-direct-drive inertial confinement fusion implosions of layered deuterium–tritium cryogenic targets on the OMEGA Laser System with respect to 1D radiation-hydrodynamic simulation predictions. A comprehensive physics-informed 3D reconstruction effort is under way to infer hot-spot and shell conditions at stagnation from four x-ray and seven neutron detectors distributed around the OMEGA target chamber. Neutron diagnostics, providing measurements of the neutron yield, hot-spot flow velocity, and apparent ion-temperature distribution, are used to infer the mode-1 perturbation at stagnation. The x-ray imagers record the shape of the hot-spot plasma to diagnose mode-1 and mode-2 perturbations. A deep-learning convolutional neural network trained on an extensive set of 3D radiation-hydrodynamic simulations is used to interpret the x-ray and nuclear measurements to infer the 3D profiles of the hot-spot plasma conditions and the amount of laser energy coupled to the hot-spot plasma. A 3D simulation database shows that larger mode-1 asymmetries are correlated with higher hot-spot flow velocities and reduced laser-energy coupling and neutron yield. Three-dimensional hot-spot reconstructions from x-ray measurements indicate that higher amounts of residual kinetic energy are correlated with higher measured hot-spot flow velocities, consistent with 3D simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experiments with neutron induced neutron emission from U-235, Pu-239, and graphite

A neutron induced neutron emission experiment was conducted as the Los Alamos Neutron Science Center (LANSCE) facility at Los Alamos National Laboratory (LANL). In this experiment, a sample was placed in a well collimated neutron beam and was surrounded by an array of 28 fast neutron detectors (EJ-309). The experiment was performed with a neutron flight path of 21.5 m from the source to the sample, and 1 m from the sample to the detectors. The neutron emission from the sample was measured as a function of neutron time of flight covering an incident energy range from 0.7- 20 MeV. The samples included U-235, Pu-239, carbon (graphite), and blanks that matched the encapsulation of the sample. The measured samples were constantly cycled in and out of the neutron beam. This type of experiment measures neutron emission from all reactions occurring in the sample such as fission and elastic and inelastic scattering. Similar to the methodology previously developed at RPI, the measurements were compared with detailed simulations of the experiment using different cross section evaluations for the sample. The observed differences can be attributed to the evaluated neutron cross section and angular distributions. The carbon sample was used as a reference to validate both the experiment and simulation methodology and showed good agreement between experiments and simulations. A review of the experimental setup, analysis methods, and some of the results will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of a Prototype Multi-Detector Fast-Neutron Radiography Panel

A multi-detector fast neutron radiography panel was built using the previous work on scalable neutron radiography using the IDEAS ROSSPAD readout module. A new aluminum housing was built to accommodate a large number of detectors tiled together. Additional changes to startup and processing code were made to operate the detector as one cohesive unit. Spatial resolution of the full panel using Cs-137 gammas was reported to be 0.42 line pairs per centimeter at 90% MTF and 2.09 line pairs per centimeter at 10% MTF. Here, three neutron radiographs generated using a Cf-252 fission neutron source were used to determine the spatial resolution of the panel for neutrons. The experiments had 90% MTF values of 0.24, 0.3, and 0.27 line pairs per centimeter and 10% MTF values of 1.30, 1.46, and 1.40 line pairs per centimeter. An example neutron radiograph was also used to prove that the radiography panel can perform true neutron radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-barrier wellbore integrity inspection system with eccentricity correction

A downhole inspection system includes a neutron imaging device operable to generate data for detecting potential wellbore anomalies and an electromagnetic imaging device operable to generate data for detecting potential wellbore eccentricity. The neutron imaging device includes a neutron generator operable to emit neutrons, and a neutron detector fixed relative to the neutron generation unit and operable to detect backscattered neutrons from a surrounding environment. The electromagnetic imaging device includes at least one transmitter for generating electromagnetic pulse, and at least one receiver for detecting returning electromagnetic pulse. Correlation of the neutron imaging data with the electromagnetic imaging data provides additional data regarding the potential wellbore anomalies.

Kasten, Ansas Matthias↗

Probing the Isospin Composition of Short-Range Correlated Pairs at Jefferson Lab Hall B

Nucleons in short-range correlated (SRC) pairs, due to their close proximity and high relative momentum, can provide insight into the short-range part of the strong nuclear interaction. In particular, the prevalence of np pairs is due to the dominance of a tensor term for correlated nucleons with momenta of approximately 400?600 MeV/c. This dissertation comprises two studies advancing the community?s understanding of the isospin composition of SRC pairs. First, I performed a study of proton and neutron knockout from initially low-momentum and high-momentum states in 3He. Previous work has shown that protons are disproportionately represented in high-momentum states in neutron-rich nuclei. I demonstrate that spectral functions for the proton-rich nucleus 3He predict, in agreement with data, that neutrons are disproportionately represented in high-momentum states, but that 3He does not display the same strong prevalence of np pairs that is observed in larger nuclei. Second, Generalized Contact Formalism (GCF), a well-supported theory for predicting SRC behavior, predicts the transition from an isospin-dependent, tensor-dominant interaction at intermediate distances to a scalar-dominant, isospin-independent interaction at very short distances. This dissertation uses data from the CLAS12 Nuclear Targets Experiments in Hall B at Jefferson Lab to measure the relative abundances of pp and pn pairs for increasing relative momentum and decreasing separation. I provide an independent confirmation of the previously-observed increase in pp pairs at increasing momentum of the struck nucleon. I also contribute to the application of the new CLAS12 Central Neutron Detector by precisely measuring the neutron detection efficiency and developing a machine learning model for rejecting charged particle background.

Seroka, Erin↗

Scintillation light detection in polycrystalline diamond using single photon detectors

Here, this study investigates the scintillation properties of polycrystalline diamond for particle detection applications, particularly in neutron and alpha radiation environments. Polycrystalline diamonds provide a cost-effective alternative to monocrystalline diamonds while retaining essential detection properties. Photoluminescence measurements were performed to analyze emission spectra, revealing distinct characteristics based on impurity content and crystallinity. Scintillation responses were assessed using Silicon Photomultipliers (SiPMs), demonstrating the capability of polycrystalline diamond powders to respond to alpha irradiation, albeit with reduced resolution compared to traditional scintillators. A prototype neutron detector was developed by combining diamond powder with neutron-sensitive 6 LiF, and its performance was evaluated through experimental testing and Geant4 simulations. The findings indicate that polycrystalline diamond-based detectors can achieve significant detection efficiency while remaining insensitive to gamma radiation, offering potential for portable neutron detection applications.

47 OTHER INSTRUMENTATION↗

Search for Neutron-Antineutron Transition in Large Neutrino Detectors

Neutron-antineutron transition is a baryon number violation process with $\Delta B=2$, providing a unique insight into the potential explanation of the baryon asymmetry in our university, especially in the context of post-sphaleron baryogenesis. Studies have been conducted in various neutron-rich environment including free neutron sources, neutron stars, and bound neutrons in large neutrino detectors, among which the large neutrino experiments obtained the most stringent constraints.

Wan, Linyan [Fermilab] (ORCID:0000000155246137)↗