Neutron detector characterization for SCINTIA array

SCINTIA is a new detector array of organic scintillators under development at the Inst. for Reference Materials and Measurements (IRMM). The present design of SCINTIA includes NE213, p-terphenyl and Li glass neutron detectors positioned in a spherical configuration around the target. The properties of a novel p-terphenyl neutron detector to be used with SCINTIA have been investigated using photon sources and neutrons from a time tagged {sup 252}Cf(sf) source. The results show that the p-terphenyl crystal has better energy resolution, increased proton light output and neutron efficiency when compared to a similar size NE213 equivalent neutron detector. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BF3 Neutron Detector Tests

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world; thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and detection capabilities are being investigated. Reported here are the results of tests of the efficiency of BF3 tubes at a pressure of 800 torr. These measurements were made partially to validate models of the RPM system that have been modified to simulate the performance of BF3-filled tubes. While BF3 could be a potential replacement for 3He, there are limitations to its use in deployed systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effects of surface recombination on the charge collection in h-BN neutron detectors

Hexagonal boron nitride (h-BN) epilayers have been recognized as a promising material for applications in solid-state neutron detectors. However, the highest detection efficiency of 58% attained so far for 1 mm 2 detectors fabricated from 50 μm thick B-10 enriched h-BN films still falls short of the expected theoretical value of 64%. This is due to the less than perfect charge collection efficiency. In this work, we have fabricated and analyzed photocurrent-voltage characteristics of 11 h-BN neutron detectors. The dependence of the charge collection efficiency ( n c ) on the charge carrier mobility-lifetime (µτ) product of the bulk trapping parameter reveals that the charge collection efficiency n c is nearly perfect at a bias voltage of 200 V if we neglect the effects of surface recombination. Our results have clearly demonstrated that the surface recombination of charge carriers is the dominant factor which prevents a further enhancement in the charge collection efficiency in our current detectors. The surface recombination field E S (= s/µ), defined as the ratio of the surface recombination velocity (s) to the carrier mobility (µ), of holes was found to have a linear relationship with that of electrons and has a magnitude on the order of 10 4 V/cm. Here the present study indicates that it is critical to reduce surface recombination E S in h-BN in order to further push the charge collection and hence the total detection efficiency of h-BN neutron detectors to 100%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Estimation of Performance of an Active Well Coincidence Counter Equipped with Boron-Coated Straw Neutron Detectors - 13401

He-3, a very rare isotope of natural helium gas, has ideal properties for the detection of thermal neutrons. As such it has become the standard material for neutron detectors and sees ubiquitous use within many radiometric applications that require neutron sensitivity. Until recently, there has been a fairly abundant supply of He-3. However, with the reduction in nuclear weapons, production of tritium ceased decades ago and the stockpile has largely decayed away, reducing the available He-3 supply to a small fraction of that needed for neutron detection. A suitable and rapidly-deployable replacement technology for neutron detectors must be found. Many potential replacement technologies are under active investigation and development. One broad class of technologies utilizes B-10 as a neutron capture medium in coatings on the internal surfaces of proportional detectors. A particular implementation of this sort of technology is the boron-coated 'straw' (BCS) detectors under development by Proportional Technologies, Inc. (PTi). This technology employs a coating of B-10 enriched boron carbide (B{sub 4}C) on the inside of narrow tubes, roughly 4 mm in diameter. A neutron counter (e.g. a slab, a well counter, or a large assay counter designed to accommodate 200 liter drums) could be constructed by distributing these narrow tubes throughout the polyethylene body of the counter. One type of neutron counter that is of particular importance to safeguards applications is the Active Well Coincidence Counter (AWCC), which is a Los Alamos design that traditionally employs 42 He-3 detectors. This is a very flexible design which can accurately assay small samples of uranium- and plutonium-bearing materials. Utilizing the MCNPX code and benchmarking against measurements where possible, the standard AWCC has been redesigned to utilize the BCS technology. Particular aspects of the counter performance include the single-neutron ('singles') detection efficiency and the time constant for the decrease in neutron population in the counter following a fission event (a.k.a. the die-away time). Results of the modeling and optimization are presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimation of Orbital Neutron Detector Spatial Resolution by Systematic Shifting of Differential Topographic Masks

We present a method and preliminary results related to determining the spatial resolution of orbital neutron detectors using epithermal maps and differential topographic masks. Our technique is similar to coded aperture imaging methods for optimizing photonic signals in telescopes [I]. In that approach photon masks with known spatial patterns in a telescope aperature are used to systematically restrict incoming photons which minimizes interference and enhances photon signal to noise. Three orbital neutron detector systems with different stated spatial resolutions are evaluated. The differing spatial resolutions arise due different orbital altitudes and the use of neutron collimation techniques. 1) The uncollimated Lunar Prospector Neutron Spectrometer (LPNS) system has spatial resolution of 45km FWHM from approx. 30km altitude mission phase [2]. The Lunar Rennaissance Orbiter (LRO) Lunar Exploration Neutron Detector (LEND) with two detectors at 50km altitude evaluated here: 2) the collimated 10km FWHM spatial resolution detector CSETN and 3) LEND's collimated Sensor for Epithermal Neutrons (SETN). Thus providing two orbital altitudes to study factors of: uncollimated vs collimated and two average altitudes for their effect on fields-of-view.

McClanahan, T. P.↗

Simulation study of a 'fission electron-collection' neutron detector

In this work, a 'fission electron-collection' neutron detector was studied using the Monte Carlo method. The detector consists of two metal electrodes mounted in a vacuum, named coated and collection electrodes, respectively. The first electrode is coated with triuranium octoxide. The detector uses the 'fission electron-collection' technique, which does not need an intermediate material but directly collects electrons from the coating. Such a detector can realize a flat energy response and a fast time response, both of which are important in the fluence measurement of pulsed neutron sources. In this paper, the physical processes of detection are presented, as well as Monte Carlo simulation studies using the Geant4 toolkit. From the results, the sensitivity of the detector is approximately 1.5 x 10{sup -21} [C/(n/cm{sup 2})], and the FWHM of response function is 2.5 nanoseconds. Additionally, the characterization of escaping electrons is also presented, and the sensitivity of the detector is determined for various coating thicknesses. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of temperature effects on self-powered neutron detectors in a gamma field

Self-powered neutron detectors (SPND) are small, robust, in-core radiation sensors that have the potential to operate in high temperature environments (above 600°C). However, previous experiments indicated temperature related effects in the form of displacement currents. Given the recent irradiation at The Ohio State University Research Reactor using a delayed-response rhodium-based SPND alongside a prompt-response tantalum-based SPND, it was concluded that only low-energy electrons from gamma interactions were the cause of these temperature effects. A series of heated gamma irradiations with temperatures up to 750°C of SPNDs were performed at the Advanced Test Reactor Gamma Facility in order to better characterize these displacement currents. The results from the experiments demonstrated a strong relation between the displacement currents that occurred during temperature ramps to thermoluminescence (TL) glow peaks—the SPND with Al2O3 insulation has one glow peak within 750°C and the SPND with MgO has three. A demonstration was performed to calculate the trap energy levels of the displacement currents through TL glow peak analysis. Unfortunately, the methods employed provided inconsistent results, requiring an updated model based on ongoing irradiation instead of post-irradiation measurements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Neutron detectors comprising ultra-thin layers of boron powder

High-efficiency neutron detector substrate assemblies comprising a first conductive substrate, wherein a first side of the substrate is in direct contact with a first layer of a powder material having a thickness of from about 50 nm to about 250 nm and comprising .sup.10boron, .sup.10boron carbide or combinations thereof, and wherein a conductive material is in proximity to the first layer of powder material; and processes of making said neutron detector substrate assemblies.

47 OTHER INSTRUMENTATION↗

Realization of highly efficient hexagonal boron nitride neutron detectors

Here, we report the achievement of highly efficient 10 B enriched hexagonal boron nitride (h- 10 BN) direct conversion neutron detectors. These detectors were realized from freestanding 4-in. diameter h- 10 BN wafers 43 μm in thickness obtained from epitaxy growth and subsequent mechanical separation from sapphire substrates. Both sides of the film were subjected to ohmic contact deposition to form a simple vertical “photoconductor-type” detector. Transport measurements revealed excellent vertical transport properties including high electrical resistivity (>10 13 Ω cm) and mobility-lifetime (μτ) products. A much larger μτ product for holes compared to that of electrons along the c-axis of h- BN was observed, implying that holes (electrons) behave like majority (minority) carriers in undoped h- BN. Exposure to thermal neutrons from a californium-252 ( 252 Cf) source moderated by a high density polyethylene moderator reveals that 43 μm h- 10 BN detectors possess 51.4% detection efficiency at a bias voltage of 400 V, which is the highest reported efficiency for any semiconductor-based neutron detector. The results point to the possibility of obtaining highly efficient, compact solid-state neutron detectors with high gamma rejection and low manufacturing and maintenance costs.

36 MATERIALS SCIENCE↗

The Versatile Array of Neutron Detectors at Low Energy (VANDLE)

The Versatile Array of Neutron Detectors at Low Energy (VANDLE) is a new array of plastic scintillator bars under development for measurements at the Holifield Radioactive Ion Beam Facility at Oak Ridge National Laboratory. The array is highly modular allowing the configuration of the individual elements to be optimized for particular experimental requirements. Proposed experiments include (d,n) reactions and beta-delayed neutron emission studies relevant to nuclear astrophysics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calibration of the neutron detectors for the cluster fusion experiment on the Texas Petawatt Laser

Three types of neutron detectors (plastic scintillation detectors, indium activation detectors, and CR-39 track detectors) were calibrated for the measurement of 2.45 MeV DD fusion neutron yields from the deuterium cluster fusion experiment on the Texas Petawatt Laser. A Cf-252 neutron source and 2.45 MeV fusion neutrons generated from laser-cluster interaction were used as neutron sources. The scintillation detectors were calibrated such that they can detect up to 10{sup 8} DD fusion neutrons per shot in current mode under high electromagnetic pulse environments. Indium activation detectors successfully measured neutron yields as low as 10{sup 4} per shot and up to 10{sup 11} neutrons. The use of a Cf-252 neutron source allowed cross calibration of CR-39 and indium activation detectors at high neutron yields ({approx}10{sup 11}). The CR-39 detectors provided consistent measurements of the total neutron yield of Cf-252 when a modified detection efficiency of 4.6 Multiplication-Sign 10{sup -4} was used. The combined use of all three detectors allowed for a detection range of 10{sup 4} to 10{sup 11} neutrons per shot.

43 PARTICLE ACCELERATORS↗

Development of a Fast-Spectrum Self-Powered Neutron Detector for Molten Salt Experiments in the Versatile Test Reactor

Abstract—The self-powered neutron detector (SPND) is a widely used flux monitor in thermal nuclear reactors. Although this is a mature technology, the current state of the art is tuned for a thermal neutron spectrum, so many of the devices currently in use lack sensitivity to fast neutrons. Because current in SPNDs is produced through nuclear reactions with the neutron flux inside a reactor, sensitivity in SPNDs is determined by the neutron cross section of the neutron-sensitive portion of the detector, termed the emitter. This neutron cross section drops by orders of magnitude between thermal and fast neutron energies for many emitters in currently used SPNDs, with a corresponding drop in current from the detector. This paper discusses efforts to develop a fast-spectrum self-powered neutron detector (FS-SPND) that is sensitive to neutrons with energies ranging from 0.025 eV up to 1 MeV. An in-depth analysis of Evaluated Nuclear Data File (ENDF)/B-VII.1 neutron-capture cross sections was performed, and four new materials were identified that are suitable emitter candidates for use in measuring fast neutrons. All four materials are stable mid-shell nuclei in the region between doubly magic 132Sn and 208Pb. Each candidate was simulated with the Geant4 Monte Carlo simulation toolkit to optimize overall detector efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-dose neutron detector project update

These are the slides for a progress review meeting by the sponsor. This is an update on the high-dose neutron detector project. In summary, improvements in both boron coating and signal amplification have been achieved; improved boron coating materials and procedures have increased efficiency by ~ 30-40% without the corresponding increase in the detector plate area; low dead-time via thin cell design (~ 4 mm gas gaps) and fast amplifiers; prototype PDT 8” pod has been received and testing is in progress; significant improvements in efficiency and stability have been verified; use commercial PDT 10 B design and fabrication to obtain a faster path from the research to practical high-dose neutron detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Fast-Spectrum Self-Powered Neutron Detector for Molten Salt Experiments in the Versatile Test Reactor

The self-powered neutron detector (SPND) is a widely used flux monitor in thermal nuclear reactors. Although this is a mature technology, the current state of the art is tuned for a thermal neutron spectrum, so many of the devices currently in use lack sensitivity to fast neutrons. Because current in SPNDs is produced through nuclear reactions with the neutron flux inside a reactor, sensitivity in SPNDs is determined by the neutron cross section of the neutron-sensitive portion of the detector, termed the emitter. This neutron cross section drops by orders of magnitude between thermal and fast neutron energies for many emitters in currently used SPNDs, with a corresponding drop in current from the detector. This paper discusses efforts to develop a fast-spectrum self-powered neutron detector (FS-SPND) that is sensitive to neutrons with energies ranging from 0.025 eV up to 1 MeV. An in-depth analysis of Evaluated Nuclear Data File (ENDF)/B-VII.1 neutron-capture cross sections was performed, and four new materials were identified that are suitable emitter candidates for use in measuring fast neutrons. All four materials are stable mid-shell nuclei in the region between doubly magic 132Sn and 208Pb. Each candidate was simulated with the Geant4 Monte Carlo simulation toolkit to optimize overall detector efficiency.

Goetz, Callie↗

Lithium and Zinc Sulfide Coated Plastic Neutron Detector Test

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. In addition, a few other companies have detector technologies that might be competitive in the near term as an alternative technology. Reported here are the results of tests of 6Li/ZnS(Ag)-coated scintillator paddles. This testing measured the required performance for neutron detection efficiency and gamma ray rejection capabilities of a system manufactured by Symetrica.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Sensitivity Fast Neutron Detector KNK-2-8M

The design of the fast neutron detector KNK-2-8M is outlined. The results of he detector study in the pulse counting mode with pulses from {sup 238}U nuclei fission in the radiator of the neutron-sensitive section and in the current mode with separation of functional section currents are presented. The possibilities of determination of the effective number of {sup 238}U nuclei in the radiator of the neutron-sensitive section are considered. The diagnostic capabilities of the detector in the counting mode are demonstrated, as exemplified by the analysis of reference data on characteristics of neutron fields in the BR-1 reactor hall. The diagnostic capabilities of the detector in the current mode are demonstrated, as exemplified by the results of measurements of {sup 238}U fission intensity in the power startup of the BR-K1 reactor in the fission pulse generation mode with delayed neutrons and the detector placed in the reactor cavity in conditions of large-scale variation of the reactor radiation fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of Spontaneous Fission Neutron Emission Energy on Neutron Detector Response

A parametric study was simulated in MCNP to investigate the impact of spontaneous fission neutron energy on neutron detector response. A total of 880 configurations were simulated by varying 3 He pressure and polyethylene reflector thickness for 8 different isotopes. Results showed that deviations between the simulated isotopes become more prevalent at higher energies with 238 U showing the greatest deviation. It was also observed that configurations comparable to most detection setups, 10 atm and 6 - 8 cm polyethylene, were closer to the upper bound of deviations from a 252 Cf. 240 Pu, a common spontaneous fission source of interest, ranged from 2% - 3% within this space. This suggests that further investigation is required to determine exact correction factors when calibrating neutron detectors with a 252 Cf. Although demonstrated here for a 4π-detection system, future plans include simulating a more detailed model of the MC-15 detection setup to determine exact correction factors for future experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗