Micro cavity fission chamber radiation detection system

A radiation detector to monitor the neutron flux of a nuclear reactor or other high-radiation environment, that can withstand the high temperatures and radiation fields of such environment, is provided. A small dielectric substrate with a low neutron-activation cross section is provided. The substrate is coated with a neutron conversion material, such as uranium oxide or thorium oxide. One or more substrates form a micro-sized detection cavity that is filled with a detection gas. A voltage is provided across anode and cathode wires in the detection cavity. A neutron absorbed in the conversion material may release reaction products into the gas, causing ionization of the gas which then produces a current or voltage signal. The small detector volume minimizes energy deposition into the detection gas by competing particles such as gamma rays, fast electrons, and beta particles, and therefore minimizes false counts while retaining large signals from neutron interactions.

McGregor, Douglas S.↗

Polyethylene Upcycling to Liquid Alkanes in Molten Salts under Neat and External Hydrogen Source-Free Conditions

Development of facile approaches to convert plastic waste into liquid fuels under neat conditions is highly desired but challenging, particularly without noble metal catalysts and an external hydrogen source. Herein, highly efficient and selective polyethylene-to-gasoline oil (branched C 6 –C 12 alkanes) conversion was achieved under mild conditions (<170 °C) using commercially available AlCl 3 -containing molten salts as reaction media and to provide catalytic sites (no extra solvents, additives, or hydrogen feeding). The high catalytic efficiency and selectivity was ensured by the abundant active Al sites with strong Lewis acidity (comparable to the Al type in acidic zeolite) and highly ionic nature of the molten salts to stabilize the carbenium intermediates. Dynamic genesis of the Al sites was elucidated via time-resolved Al K-edge soft X-ray and 27 Al NMR, confirming the tricoordinated Al 3+ as active sites and its coordination with the as-generated alkene/aromatic intermediates. Further, the carbenium formation and polyethylene chain variation was illustrated by inelastic neutron scattering (INS) and an isotope-labeling experiment. Theoretical simulations further demonstrated the successive hydride abstraction, β-scission, isomerization, and internal hydrogen transfer reaction pathway with AlCl 3 as active sites. This facile catalytic system can further achieve the conversion of robust, densely assembled, and high molecular weight plastic model compounds to liquid alkane products in the diesel range.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantifying Burst Repeatability for Godiva IV

The minimum resolvable relative change in the neutron source emission of Godiva IV between bursts, i.e., burst repeatability, was quantified using a combination of activation monitors and a resistance temperature detector (RTD). Measurements support changes in the neutron source emission between bursts can be determined with a precision of 2.7%. The measurements were performed during a series of twelve Godiva IV bursts and were a collaborative effort between Los Alamos National Laboratory, Sandia National Laboratories, and Pacific Northwest National Laboratory. Gold, iron, nickel, and sulfur activation monitors were positioned in a sample holder in the central cavity of Godiva IV for each burst. The RTD is part of the Godiva burst diagnostic system and is in a fixed location in the safety block of Godiva IV. It is used to determine the temperature rise of the burst, i.e., the difference between the maximum temperature recorded during the burst and the initial temperature prior to the burst. Differences in either the specific activity of the activation monitor reactions, or the temperature rise can be used to determine the relative change in the neutron source emission for separate bursts, but historic results have proven that each method is susceptible to various sources of biases which generally cannot be isolated using a single method. We address this issue by applying both measurement methods and analyzing the correlation between them. The results presented in this work will be used to support future experiments with Godiva IV at the National Criticality Experiments Research Center (NCERC).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CNRS Molten Salt Reactor Benchmark Analysis Using Griffin-Pronghorn Coupled Multi-physics Code System

Molten salt reactors (MSRs) with flowing fuel have the unique feature of utilizing the fuel salt for heat generation and extraction at the same time, since the fuel salt is circulating through the whole primary loop. This movement of fuel salt results in a partial decay of the delayed neutron precursors (DNPs) outside the core and the corresponding redistribution of the DNPs in the active region of the core. To capture this effect, neutronics and thermal-hydraulics (T/H) codes need to be able to handle the movement of DNPs and their decay [1, 2]. Idaho National Laboratory (INL) is actively working on developing the neutronics and T/H codes to model the MSRs with flowing fuel. As one of the efforts, the neutronics code Griffin [3] and the T/H code Pronghorn [4] that are built upon the MOOSE framework [5] have been extended to handle the flowing fuel involving the drift of DNPs, and this capability is being tested and verified with MSR benchmark problems including the CNRS benchmark problem [6]. Additionally, a multi-physics analysis of the molten salt reactor experiment (MSRE) is being conducted to verify and validate the codes against available experimental data [7]. This work presents the analysis of the CNRS benchmark problem using the Griffin-Pronghorn coupled multi-physics code system of INL. Both steady-state and transient problems are analyzed, and the results are compared with those of other participants presented in [6]. The following section provides a description of the benchmark, along with input parameters and observables for each step. Then, the results for each step are presented in comparison with other participants’ results, followed by summary and conclusion.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of the Rossi-alpha method to simulations of HEU and organic scintillators

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook contains thousands of high-quality benchmark measurements that include detailed descriptions of experiment designs and exhaustive accounting of uncertainties. These benchmarks are used extensively by the criticality safety and nuclear data communities. A subcritical benchmark involving bare, highly enriched uranium (HEU) has yet to be accepted to the handbook. The Measurement of Uranium Subcritical and Critical (MUSiC) was proposed to address this gap. MUSiC will be performed at the National Criticality Experiments Research Center (NCERC) and will leverage bare HEU hemisphere shells that can be assembled in a variety of configurations. The measurement has the following key benefits: it will be the first set of fast, subcritical measurements of HEU to be submitted to ICSBEP; ten configurations will be measured spanning from nearly no multiplication to critical (e.g., it is a measurement of similar systems with different re activities); measurements of an all-HEU system will be of value for nuclear data validation, providing results that assist in determining biases in both measurements and simulations. A variety of detector systems will be used including a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (#8960;) × 7.59 cm 3He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), and an array of eight 5.08 cm (#8960;) × 5.08 cm EJ-309 organic scintillator detectors. The focus of this work is the simulation of the subcritical MUSiC configurations including the EJ-309 detectors and the application of the Rossi-α method. The EJ-309 organic scintillator detector array is a new detection system that will be deployed at NCERC. Organic scintillators are ideal for measurements of fast, subcritical systems due to their short time response on the order of nanoseconds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Short-Lived Isotope Counting System (SLICS) to measure reaction cross sections producing light, beta-decaying nuclei on OMEGA

A new activation detector optimized for short-lived isotopes was designed, installed, and tested on OMEGA. The Short-Lived Isotope Counting System (SLICS) can be positioned as close as 35 cm from the OMEGA target chamber center in a ten-inch-manipulator. Stable target samples can be mounted on the front end of the detector assembly to undergo triton-, deuteron-, or neutron-induced reactions that produce short-lived reaction products that beta decay. The emitted betas are detected in a phoswich configuration to eliminate the gamma background. The detector is optimized for isotopes with half-lives from 150 ms to 20 s, filling a gap in OMEGA’s current activation detectors for isotopes with half-lives >5 min. In a pilot study, SLICS achieved an efficiency of 24.5% ± 2.0% for counting 8Li, with a total of 505.8 ± 4.4 qualifying events. Using the existing triton laser-ion acceleration platform on OMEGA, this detector can be used to measure rarely studied tritium-induced reactions on light nuclei with an estimated uncertainty of 12%. As a result, the design of the detector and its performance during a first experiment employing deuterium as a surrogate will be discussed.

Beta spectrometry↗

Measurements of the emanation of 37Ar and 39Ar from irradiated rocks and powders

The emanation fraction of radionuclides has been highlighted as a known source of uncertainty in the estimation of radionuclide source signatures from underground nuclear tests and other nuclear activities, particularly in the case of activation products. A system was developed at Pacific Northwest National Laboratory to quantify the emanation fraction of argon from samples ranging in particle size from powder to small rocks. Seven materials, two powders and five rock types, were neutron irradiated and the emanation fraction of 37Ar was measured. Additional measurements were made of the 39Ar emanation for four of these materials.

Johnson, Christine M.↗

High-temperature 205 Tl decay clarifies 205 Pb dating in early Solar System

Radioactive nuclei with lifetimes on the order of millions of years can reveal the formation history of the Sun and active nucleosynthesis occurring at the time and place of its birth. Among such nuclei whose decay signatures are found in the oldest meteorites, 205 Pb is a powerful example, as it is produced exclusively by slow neutron captures (the s process), with most being synthesized in asymptotic giant branch (AGB) stars. However, making accurate abundance predictions for 205 Pb has so far been impossible because the weak decay rates of 205 Pb and 205 Tl are very uncertain at stellar temperatures. To constrain these decay rates, we measured for the first time the bound-state β - decay of fully ionized 205 Tl 81+ , an exotic decay mode that only occurs in highly charged ions. The measured half-life is 4.7 times longer than the previous theoretical estimate and our 10% experimental uncertainty has eliminated the main nuclear-physics limitation. With new, experimentally backed decay rates, we used AGB stellar models to calculate 205 Pb yields. Propagating those yields with basic galactic chemical evolution (GCE) and comparing with the 205 Pb/ 204 Pb ratio from meteorites, we determined the isolation time of solar material inside its parent molecular cloud. We find positive isolation times that are consistent with the other s-process short-lived radioactive nuclei found in the early Solar System. Our results reaffirm the site of the Sun’s birth as a long-lived, giant molecular cloud and support the use of the 205 Pb– 205 Tl decay system as a chronometer in the early Solar System.

79 ASTRONOMY AND ASTROPHYSICS↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Ultra-rapid, physics-based development pathway for reactor-relevant RF antenna materials

This paper presents a rapid, atomistically-informed, experimental development pathway for fusion reactor-relevant radio frequency (RF) antenna materials in the Cu-Cr-(Nb,Al,Zr) composition system, with the goal of improving upon GRCop-84. RF antennas in a tokamak fusion reactor will face a unique set of challenges as both structural and functional materials. The desired material must simultaneously achieve and maintain high electrical conductivity, high strength, high thermal conductivity, resist high temperatures, possess low nuclear activation, and incur low damage due to neutron bombardment. The GRCop-84 alloy serves as a starting point for iterative improvement, with the desire to reduce or eliminate Nb from the material to minimize nuclear activation. The rapid development pathway makes use of a multi-target combinatorial thick film sputtering process to produce full ternary phase diagrams on a Si wafer substrate. Transient grating spectroscopy (TGS), a laser-ultrasonic method, will determine spatially-varying thermo-elastic properties, while four terminal electrical conductivity measurements will map out the best per- forming regions of the sample for in-depth study at larger length scales. High energy proton and self-ion irradiation emulates the effects of neutron damage on the thermal/electric properties. With rapid turnaround time (∼days) in terms of mapping radiation damage-induced material property changes in the full ternary system, these techniques allow rapid iteration towards an optimal material, testing hundreds of nearby compositions in the time it took to test one. Focused testing of larger, single composition samples (produced in an arc furnace or by laser sintering) provides data on structural and high power RF properties, and validates our thick-film based workflow.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pervasive symmetry-lowering nanoscale structural fluctuations in the cuprate La 2−𝑥 ⁢Sr 𝑥 ⁢Cu⁢O 4

The cuprate superconductors are among the most widely studied quantum materials, yet there remain fundamental open questions regarding their electronic properties and the role of structural degrees of freedom. Recent neutron and x-ray scattering measurements uncovered exponential scaling with temperature of the strength of orthorhombic fluctuations in the tetragonal phase of La 2−𝑥⁢ Sr 𝑥 ⁢Cu⁢O 4 and Tl 2 ⁢Ba 2 ⁢Cu⁢O 6+𝛿 , unusual behavior that closely resembles prior results for the emergence of superconducting fluctuations, and that points to a common origin rooted in inherent correlated structural inhomogeneity. Here, in this study, we use neutron and x-ray diffuse scattering to provide further insight into structural fluctuations in La 2−𝑥 ⁢Sr 𝑥 ⁢Cu⁢O 4 . We perform measurements up to temperatures that approach the melting point of the undoped parent compound, and we investigate the effects of in situ in-plane uniaxial elastic stress and plastic deformation. Our neutron scattering results for the parent compound La 2 ⁢Cu⁢O 4 reveal that short-range orthorhombic fluctuations persist to the maximum experimental temperature of nearly 1000 K, i.e., to a significant fraction of the crystallization temperature. At this temperature, the spatial characteristic length extracted from the momentum-space data is still about three lattice constants. The neutron scattering experiment enables quasistatic discrimination and reveals that the response is increasingly dynamic at higher temperatures. We also find that neither compressive elastic stress along the tetragonal [110] direction nor irreversible plastic deformation activating the ⟨100⟩⁢[001] slip system significantly alter the robust orthorhombic fluctuations. Overall, these results support the notion that these fluctuations couple to subtle, underlying inhomogeneity that underpins the cuprate phase diagram. Finally, in La 1.8⁢ Sr 0.2⁢ Cu⁢O 4 , we uncover low-energy structural fluctuations at a nominally forbidden reflection that are distinct from the orthorhombic distortions. While the origin of these fluctuations is not clear, they might be related to the presence of extended defects such as dislocations or stacking faults.

Spieker, R. J. [Univ. of Minnesota, Minneapolis, M↗

Tritium Extraction from FLiBe using a Permeation Against Vacuum (PAV): Impact of Surface Potentials, Currents, and Coupling PAV to Sacrificial Anodes

Savannah River National Laboratory (SRNL) is exploring a concept of pairing a LiF-BeF2 (FLiBe) immersed Permeation Against Vacuum (PAV) tritium extraction system with a sacrificial anode. Several fusion concepts utilize FLiBe for tritium breeding, and breeding of tritium would occur from neutron interactions with the Li component, creating corrosive TF and/or T2. In absence of a redox buffered system, the TF would be able to attack containment materials until neutralized. One way to neutralize TF is to contact it with an active metal such as Be or Li which would preferentially combine with the fluorine in the TF to form BeF2 or LiF, respectively, and resulting in T2. When the active metal (e.g., Be) is oxidized, it will provide electrons, when T in TF is reduced and forms T2, it needs electrons. SRNL proposes to electrically link these two reactions and with the PAV to help drive the reactions faster than on their own and potentially increase T2 dissociation. In a soluble redox salt buffered system, it is expected that with sufficient buffering, T2, may form more rapidly and the core components would be more protected, but the soluble redox salt buffer would need to be occasionally regenerated, which could be accomplished by again contacting the salt with an active metal such as Be or Li, although in this case the cathodic reaction would be electrons coming from the shift in oxidative state of the redox buffer. The exploration of potential and current effects on the PAV and impacts of redox agents will be discussed.

Olson, Luke C.↗

Detecting and characterizing special nuclear material for nuclear nonproliferation applications

Abstract There is an urgent need for new, better instrumentation and techniques for detecting and characterizing special nuclear material (SNM), i.e., highly enriched uranium and plutonium. The development of improved instruments and techniques requires experiments performed with the SNM itself, which is of limited availability. This paper describes the findings of experiments performed at the National Criticality Experiments Research Center conducted using new instruments and techniques on unclassified, kg-quantity SNM objects. These experiments, performed in the framework of the Department of Energy, National Nuclear Security Administration Consortium for Monitoring, Technology, and Verification, focused on detecting, characterizing, and localizing SNM samples with masses ranging from 3.3 to 13.8 kg, including plutonium and highly enriched uranium using prototype detectors and techniques. The work demonstrates SNM detection and characterization using recently-developed prototype detection systems. Specifically, we present new results in passive detection and imaging of plutonium and uranium objects using gamma-ray and dual particle (fast neutron and gamma-ray) imaging. We also present a new analysis of the delayed neutron emissions during active interrogation of uranium using a neutron generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of emanation of Ar-37 and Ar-39 from irradiated rocks and powders

The emanation fraction of radionuclides has been highlighted as a known source of uncertainty in the estimation of radionuclide source signatures from underground nuclear tests and other nuclear activities, particularly in the case of activation products. A system was developed at Pacific Northwest National Laboratory to quantify the emanation fraction of argon from samples ranging in particle size from powder to small rocks. Seven materials, two powders and five rock types, were irradiated with fission spectrum neutrons and the emanation fraction of 37 Ar was measured. Additional measurements were made of the 39 Ar emanation for four of these materials.

36 MATERIALS SCIENCE↗

A comparison of machine learning methods to classify radioactive elements using prompt-gamma-ray neutron activation data

The detection of illicit radiological materials is critical to establishing a robust second line of defence in nuclear security. Neutron-capture prompt-gamma activation analysis (PGAA) can be used to detect multiple radioactive materials across the entire Periodic Table. However, long detection times and a high rate of false positives pose a significant hindrance in the deployment of PGAA-based systems to identify the presence of illicit substances in nuclear forensics. In the present work, six different machine-learning algorithms were developed to classify radioactive elements based on the PGAA energy spectra. The model performance was evaluated using standard classification metrics and trend curves with an emphasis on comparing the effectiveness of algorithms that are best suited for classifying imbalanced datasets. We analyse the classification performance based on Precision, Recall, F1-score, Specificity, Confusion matrix, ROC-AUC curves, and Geometric Mean Score (GMS) measures. The tree-based algorithms (Decision Trees, Random Forest and AdaBoost) have consistently outperformed Support Vector Machine and K-Nearest Neighbours. Based on the results presented, AdaBoost is the preferred classifier to analyse data containing PGAA spectral information due to the high recall and minimal false negatives reported in the minority class.

97 MATHEMATICS AND COMPUTING↗

Frontier system-on-chip (SoC) technology for microwave diagnostics (invited)

The next generation of fusion reactors, exemplified by projects such as the Demonstration Power Plant following the International Thermonuclear Experimental Reactor, faces the monumental challenge of proving the viability of generating electricity through thermonuclear fusion. This pursuit introduces heightened complexities in diagnostic methodologies, particularly in microwave-based diagnostics. The increased neutron fluence necessitates significant reductions in vessel penetrations and the elimination of internal diagnostics, posing substantial challenges. SoC technology offers a promising solution by enabling the miniaturization, modularization, integration, and enhancing the reliability of microwave systems. After seven years of research, our team successfully pioneered the V- and W-band system-on-chip approach, leading to the development of active transmitters and passive receiver modules applied in practical settings, notably within the DIII-D tokamak project. Arrays of these modules have supported microwave imaging diagnostics. New physics measurement results from the Electron Cyclotron Emission Imaging system on DIII-D provide compelling evidence of improved diagnostics following the adoption of SoC technology. Furthermore, we achieved a breakthrough in developing an F-band SoC, advancing higher frequency capabilities for fusion devices. These achievements represent a significant leap forward in fusion diagnostic technology, marking substantial progress toward establishing reliable and efficient plasma diagnostics for future fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Secondary-Source Core Reload Modeling with VERA

The CASL reactor simulation package VERA has been adapted to provide high-fidelity simulation capabilities for modeling source range detector response during subcritical reactor configurations. New features include the activation and shuffling of secondary-source assemblies, use of burned fuel neutron emission data from the ORIGEN depletion solver to the MPACT deterministic neutron transport solver, allowance of user-defined sources in MPACT based on material composition, ability to solve the subcritical source-driven system with neutron multiplication using the MPACT diffusion solver, and transfer of the calculated fission source from MPACT to the continuous-energy Monte Carlo solver Shift for final detector response evaluation using the CADIS methodology for variance reduction. These new capabilities were benchmarked against Watts Bar Unit 1 plant operating data for the first few fuel loading steps and were found to demonstrate excellent agreement with the measured data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Glass-bonded ceramic waste forms for immobilization of radioiodine from caustic scrubber wastes

Glass-bonded sodalite composite waste forms have been developed for the immobilization of liquid radioactive wastes resulting from off-gas treatment during aqueous reprocessing of used nuclear fuel, with a particular focus on 129I. The proposed composite waste form is comprised of aluminosilicate ceramic phases containing volatile radionuclides bonded with a glassy matrix. In this work, a suite of ten candidate low-temperature glass binders (ZnO-Bi2O3-based glasses and a Na2O-B2O3-SiO2 glass) were examined. Six glasses were mixed with caustic scrubber waste simulant previously converted into a sodalite-rich material (to provide glass fractions of 10 and 20 wt.%), uniaxially pressed into pellets, and sintered at 350 °C or 550 °C for 8 h in air. Iodine retention after heat treatment was assessed by neutron activation analysis, showing retention of 67-100 % of expected iodine. The aqueous durabilities of the resulting materials were then determined, following the ASTM C1308 standard test, showing iodine releases of 1 to 23 g m-2 after 4 d. The cumulative iodine release for the best performing system (a zinc-bismuth-borate glass binder) was <1 g m-2, and its iodine retention from processing was 67 %. The iodine releases compared favorably with other waste forms. In parallel, this best-performing composition was also consolidated via hot isostatic pressing (HIP) in a stainless-steel canister at 550 °C for 2 h under 100 MPa pressure. The HIPed sample was produced at the ~20 g scale and showed improved densification and minimal reaction with the canister.