Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Anisotropy in Thermal Conductivity of Ga2O3 under Irradiation: Ab-initio Investigations

Ga2O3 is a wide-bandgap semiconducting material known for its high breakdown electric field and thermal stability. Its various crystalline forms have shown great potential in power electronics, optoelectronics, and high-temperature applications. Specifically, ß-Ga2O3 has been recognized for its suitability in neutron and gamma radiation detection, making it ideal for sensor and detector applications [1]. Notably, ß-Ga2O3 exhibits anisotropic thermal conductivity, meaning that the magnitude of thermal conductivity varies with the crystallographic direction [2]. Under neutron irradiation, Ga2O3 undergoes a significant phenomenon, resulting in the formation of Helium bubbles within its crystalline matrix. The presence of Helium in Ga2O3 has been found to influence the material's anisotropic thermal conductivity. In this study, the objectives were twofold: firstly, to employ Density Functional Theory (DFT) to determine the most probable sites of Helium occupation in ß-Ga2O3, and secondly, to investigate the anisotropic variation in thermal conductivity when Helium is present in the crystalline matrix of ß-Ga2O3. These ab-initio DFT studies provide crucial insights into understanding the behavior of Helium in Ga2O3 and its impact on thermal conductivity, which can contribute to further advancements in sensor and detector applications based on this wide-bandgap semiconductor.

36 MATERIALS SCIENCE↗

NIF-TAS Miniature Calibration Station

“On Aug. 8, 2021, an experiment at Lawrence Livermore National Laboratory’s (LLNL’s) National Ignition Facility (NIF) made a significant step toward ignition, achieving a yield of more than 1.3 megajoules (MJ). This advancement puts researchers at the threshold of fusion ignition, an important goal of the NIF, and opens access to a new experimental regime.” NIF experiments are conducted by symmetrically focusing 192 laser beams from NIF (three football fields in length) into the Target Chamber (10-meter diameter sphere) onto a target 2mm in size. The reaction produces a hot spot the diameter of a human hair, generating more than 10 quadrillion watts of fusion power for 100 trillionths of a second. These high pressures and temperatures created by the NIF have only been seen on the surface of the sun. To achieve fusion ignition, the target must be compressed to high pressures and temperatures, which requires symmetric compression. This symmetry requires precise alignment of the laser beams to the target. To achieve this precise symmetry a Target Alignment System (TAS) was developed to aid in aligning the beams to the target. The accomplishment on Aug 8 th could not have been accomplished without the TAS. TAS has proven to be a critical contributor to the success of NIF experiments. Each TAS is composed of several Charge Couple Device (CCD) sensors and various support electronics. Unfortunately, these CCDs are no longer available in industry as they have become outdated and obsolete. There is a limited amount of spare CCDs in the facility. As the NIF continues to increase its energy output of its fusion ignition shot experiments (heigh yield shots), more neutrons are being emitted from the Target Chamber. These neutrons are very damaging to the TAS electronics and its sensors, thus degrading and reducing its life expectancy dramatically. The increase of neutrons exceeds the damage threshold of the CCDs. This would increase the demand for more frequent TAS refurbishments and calibrations. The increase in resources to perform these refurbishments and calibrations would not be sustainable. In efforts to prolong the life of each TAS system it was determined that the TAS should be removed for every High Yield Shot and then reinstalled. The high precision fully calibrated TAS can easily be knocked out of alignment during these installs and reinstall exchanges and being transported in and out of the NIF. The Miniature Calibration Station System was developed to verify that the critical calibration parameters have been preserved during every TAS exchange. The Miniature Calibration Station System (Mini-Cal) would need to be a scaled down (in size and scope), portable version of the offline TAS calibration station to verify the critical TAS parameters are still within tolerances.

42 ENGINEERING↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Displacement Damage Induced Dark Current and Random Telegraph Signal in P-Type Deep-Trench Pinned Photogates

This study focuses on displacement damage induced dark current and Random Telegraph Signal (RTS) in STMicroelectronics P-Type photogate, a device moving away from the 4T Pinned-Photodiode, with a sensitive volume exclusively made of boron-doped P-type epitaxy, and collecting holes instead of electrons. Results show a typical trend for the shape of dark current and RTS degradation in CMOS Image Sensors with the exception that the measured generation rates seem 2 times smaller than typical literature values in irradiated silicon. Different hypothesis on the origin of this discrepancy are explored.

displacement damage dose↗

Towards Realistic and High Fidelity Models for Nuclear Reactor Power Synthesis Simulation with Self-Powered Neutron Detectors

As presented in this report, a weighting function–based inferencing method is being applied to synthesize the power distribution in next-generation and university research reactors based on simulated self power neutron detector (SPND) responses. The overall goal is to assess the impacts of sensor uncertainty and true power distribution perturbations on the error in the synthesized power distribution. Regarding sensor uncertainty, the NuScale Small Modular Reactor (SMR) and the Westinghouse AP1000 serve as testbeds for analyzing the impact of varying the sensor uncertainty, as well as varying the number of sensors per sensor string in the reactor core. The reactor models are informed by Monte Carlo N-Particle (MCNP) neutron flux tallies. For the NuScale SMR and Westinghouse AP1000, the SPND response functions (i.e., the response of the SPNDs to individual segments of fuel) were determined homogeneously. Regarding an analysis of power distribution perturbation detection, the Texas A&M Testing, Research, Isotopes, General Atomics Reactor (TAMU TRIGA) reactor was used as a demonstration case with one particular arrangement of SPNDs; the response functions for this reactor model were determined heterogeneously, making this a uniquely high-fidelity demonstration of perturbation detection. Finally, SPND models generated in the Geometry and Tracking 4 (Geant4) code have been generated and tested for comparison with traditionally implemented analytical SPND models, with the intent for Geant4 integration with the full methodological framework. SPND current outputs as a function of distance from some fuel assembly segment in the NuScale SMR are compared with the analytically determined currents. Results from the sensor uncertainty simulations for the NuScale SMR and AP1000 indicate that the average error in the inferred power distribution on the fuel assembly segment level is reasonably low, being slightly less than the random uncertainty applied to all respective SPNDs in both cores. For example, if all SPNDs in the core have a random uncertainty of 5%, then the corresponding fuel assembly segment level error (i.e. difference between the true and inferred local power) is ~2–3%. However, the maximum error in the inferred power distribution on the fuel assembly segment level can be considerably high (>15%) when SPND random uncertainties start to exceed ~3%. In general, the average and maximum errors in the inferred power distribution were slightly higher in the AP1000 as opposed to the NuScale SMR for the sensor string configurations considered herein. Another result determined from analysis of the sensor uncertainty simulations was that increasing the number of SPNDs per string does not clearly reduce inferred power distribution error and can in fact make the error large in some cases; however, this assessment may skewed due to imposed iteration limits. Results from the perturbation detection demonstration using the high-fidelity TAMU TRIGA model indicate that, given the arrangement of 17 SPND strings and 4 SPNDs per string considered herein, there is a clear, provable ability to infer a localized Gaussian-type peak perturbation in the 3D power distribution. Such a perturbation was detected with an average fuel assembly segment level error of 0.19%, and the general visualization of the detected perturbation clearly indicates that the magnitude and shape were appropriately resolved. Finally, the electrical current output generated by the Geant4 modeled SPND indicates significant magnitude differences than the analytically modeled SPND, demonstrating the need for accurate SPND models which account for finite sensor geometry effects to inform the power synthesis work described herein.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sensor Reduction for Diversion Detection in a Realistic Heat Pipe Microreactor Using Supervised Machine Learning

Microreactors are designed as a smaller, cheaper, and safer alternative to traditional nuclear power plants. Their non-traditional characteristics and prospect of mass production and deployment will likely require new approaches to nuclear safeguards. The primary proliferation concern with microreactors is the diversion of fuel material. Such diversion may produce measurable defects in key physical attributes like neutron flux, which may in turn be detectable using machine learning models. Preliminary work has demonstrated this ability for modeled nominal and diversion scenarios using large quantities of energy integrated neutron flux data. In practice, the number of available sensors for such measurements will be limited and energy integrated flux information will not be available. This work explores the ability of tree-based gradient boosted ensemble models to classify a given microreactor core is nominal or diversion, and determine the number of fuel pins diverted in the case of diversion with reduced numbers of sensors and more realistic detector responses. Classification accuracy of greater than 98% and regression errors as low as 5% of the total number of fuel pins were achieved with as few as 15 sensors, compared to 99% and 4.1% with a maximum of 240 sensors.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiation, optical, power flow, and electrical diagnostics at the Z facility: Layout and techniques utilized to operate in the harsh environment

The Z machine is a current driver producing up to 30 MA in 100 ns that utilizes a wide range of diagnostics to assess accelerator performance and target behavior conduct experiments that use the Z target as a source of radiation or high pressures. Here, we review the existing suite of diagnostic systems, including their locations and primary configurations. The diagnostics are grouped in the following categories: pulsed power diagnostics, x-ray power and energy, x-ray spectroscopy, x-ray imaging (including backlighting, power flow, and velocimetry), and nuclear detectors (including neutron activation). We will also briefly summarize the primary imaging detectors we use at Z: image plates, x-ray and visible film, microchannel plates, and the ultrafast x-ray imager. The Z shot produces a harsh environment that interferes with diagnostic operation and data retrieval. We term these detrimental processes “threats” of which only partial quantifications and precise sources are known. Finally, we summarize the threats and describe techniques utilized in many of the systems to reduce noise and backgrounds.

47 OTHER INSTRUMENTATION↗

Yeast Strain Development and Hardware Testing in Preparation of a Lunar BioSensor

With Artemis missions underway, it is clear we are going back to the Moon to stay. Before sending Astronauts for long-duration missions, it is crucial to understand the technological and biomedical countermeasures needed to protect them before they get there. We can use knowledge gained from biological CubeSats to guide the next generation of experiments to support human habitation on the Moon. Lunar Explorer Instrument for space biology Applications (LEIA) is NASA’s latest BioSensor, adapted BioSentinel, the only CubeSat to travel Beyond Low Earth Orbit. BioSentinel launched on Artemis I and is currently >50 million kilometers from Earth (as of July 2024). LEIA aims to identify biological responses to the Lunar environment, which unprotected against would pose a threat to astronauts (cancer, cardiovascular disease, neurological impairment). The suite of instruments within LEIA detects Lunar radiation using two on-board radiation sensors (ARES charged particle detector, Mini-Fast Neutron Detector), then monitors real-time biological responses to the Lunar environment via an autonomous microfluidic system, fit with 3-LED emitter and detector boards and the alamarBlue metabolic indicator dye. LEIA will use a genetic approach in addition to synthetic biology to test counter-measure production in space, with the goal to inform and protect astronauts for future Moon missions. We have conducted preliminary tests in preparation for launch to the anticipated South Pole of the Moon, optimizing the biology (strain down-selection, desiccation tolerance, radiation sensitivity) and improving the hardware (including a blue LED to detect the beta-carotene countermeasure product). Our team will discuss these findings in several parts – an overview of the LEIA mission (Mark Settles), adapting flexible CubeSat platforms for deep-space applications (Sergio Santa Maria, Kira Rienecker), developing new technologies to support LEIA ground studies (Chinmayee Govinda Raj), and yeast strain development and hardware testing in preparation for LEIA (presented here).

synthetic biology↗

Retractable Sensors for In-Core Use in Material Test Reactors - conf paper

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on friction drive wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 – 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 – 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology’s MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the high-yield time-gated x-ray hot-spot imager for OMEGA

Time-resolved x-ray self-emission imaging of hot spots in inertial confinement fusion experiments along several lines of sight provides critical information on the pressure and the transient morphology of the hot spot on the University of Rochester’s OMEGA Laser System. At least three quasi-orthogonal lines of sight are required to infer the tomographic information of the hot spots of deuterium–tritium cryogenic layered implosions. OMEGA currently has two time-gated x-ray hot-spot imagers: the time-resolved Kirkpatrick–Baez x-ray microscope and the single-line-of-sight, time-resolved x-ray imager (SLOS-TRXI). The time-gated x-ray hot-spot imager (XRHSI) is being developed for use on OMEGA as the third line of sight for the high-yield operation of up to 4 × 10 14 neutrons. XRHSI follows the SLOS-TRXI concept; however, it will have improved spatial and temporal resolutions of 5 μm and 20 ps, respectively. The simultaneous operation of the three instruments will provide 3-D reconstructions of the assembled hot-spot fuel at various times through peak thermonuclear output. The technical approach consists of a pinhole array imager and demagnifying time-dilation drift tube that are coupled to two side-by-side hybrid complementary metal–oxide semiconductor (hCMOS) image sensors. To minimize the background and to harden the diagnostics, an angled drift-tube assembly shifting the hCMOS sensors out of the direct line of sight and neutron shielding will be applied. As a result, the technical design space for the instrument will be discussed and the conceptual design will be presented.

47 OTHER INSTRUMENTATION↗

The weathered bedrock vadose zone: A hidden control on water availability in the western United States (Final Technical Report)

This report summarizes the research completed during the project entitled "The weathered bedrock vadose zone: A hidden control on water availability in the western United States" (Award: DE-SC0018039). The report covers work completed between 9/15/17 and 9/14/20. The objective of the exploratory project work was to evaluate the overarching hypothesis that the subsurface underlying actively eroding landscapes is systematically structured as a result of a balance between weathering and erosion and that this structure leads to dynamic moisture storage within weathered rock. To accomplish project objectives, we characterized hillslope weathering profile structure and conducted subsurface moisture monitoring across four study sites with comparable bedrock types but differing erosion rate and hydroclimate: The Angelo Coast Range Reserve (ACRR), Sagehorn-Russell Ranch (SRR), Antelope Valley Ranch (AVR), and the LBNL Watershed Function Scientific Focus Area (SFA). New characterization and monitoring infrastructure at the AVR and SFA sites was established through this project and enables long-term monitoring of hydrologic and carbon fluxes at the sites for comparison with long-term monitoring in other sites. Deep drilling, downhole logging, and characterization of chemistry and porosity of rock recovered from drilling reveals two weathering fronts across the sites. A shallower front is marked by the extent of pervasive fracturing and oxidation of pyrite and organic carbon. A deeper weathering front is marked by the appearance of open fractures and discoloration. At the AVR site, multiple ridge tops of different hillslope length were investigated to establish the relationship between the weathering front and topography. Drilling reveals that the fraction of the hillslope relief that is weathered scales with hillslope length, consistent with the theoretical framework that guided the project relating groundwater drainage with landscape evolution. With the establishment of new boreholes, we have documented significant water storage in weathered bedrock using low-field borehole nuclear magnetic resonance (NMR) across all four sites. In the upper 4 m of bedrock, the average water contents at ACRR, AVR, SRR, and SFA are approximately 25%, 16%, 25%, 23% respectively. At the ACRR site, where long-term monitoring via neutron probe surveys and time-domain transmission sensors are available, we have demonstrated that NMR reliably records moisture content and importantly, moisture content dynamics in weathered bedrock. Across all sites, our NMR monitoring has also revealed that a considerable fraction of the water storage occurs in fractures or pores that are significantly larger than the fine-grained bedrock matrix of the parent rock. To identify the proportion of water storage occurring in fractures and large pores, we analyzed the NMR signal by evaluating both the sum of echoes and an inversion of the NMR signal for a distribution of T2 relaxation times. Both methods reveal that at least 20% of the water storage occurs in fractures and larger pores across all sites. To constrain the interpretation of the in-situ field-scale NMR measurements, we compare the NMR response in the field to independent pore-structure information obtained via helium pycnometry. Results support the inference that dynamic seasonal water storage is dominantly restricted to the fracture network, which can reach 7% of the total volume. This dynamic range in water content is comparable to that of some soils, underscoring the need to understand how this region of the Earth System is structured, and functions as a hydrologic reservoir.

58 GEOSCIENCES↗

Fast neutron radiography-based on single-photon digital photosensor: concept and demonstration

For decades, fast neutron radiography performed using pulse-counting detectors employed PMTs coupled to plastic scintillator pixel arrays. SiPM-based systems are now sought to replace fragile PMTs, but conventional, “analog” SiPMs suffer from intrinsic limitations which limit their achievable performance. Among these limitations, a complete analog readout and digitizer chain is required, a counterintuitive approach when considering that the single-photon avalanche diode (SPAD), the basic unit cell of SiPMs, is a Boolean detector providing digital detection at the sensor level. This paper outlines a new concept for neutron radiography instrumentation by using photon-to-digital converters (PDCs, aka digital SiPMs), a fully digital solution to sense the scintillation light.

Pratte, Jean-Francois↗

Progress Towards Developing Neutron Tolerant Magnetostrictive and Piezoelectric Transducers

Current generation light water reactors (LWRs), sodium cooled fast reactors (SFRs), small modular reactors (SMRs), and next generation nuclear plants (NGNPs) produce harsh environments in and near the reactor core that can severely tax material performance and limit component operational life. To address this issue, several Department of Energy Office of Nuclear Energy (DOE-NE) research programs are evaluating the long duration irradiation performance of fuel and structural materials used in existing and new reactors. In order to maximize the amount of information obtained from Material Testing Reactor (MTR) irradiations, DOE is also funding development of enhanced instrumentation that will be able to obtain in-situ, real-time data on key material characteristics and properties, with unprecedented accuracy and resolution. Such data are required to validate new multi-scale, multi-physics modeling tools under development as part of a science-based, engineering driven approach to reactor development. It is not feasible to obtain high resolution/microscale data with the current state of instrumentation technology. However, ultrasound-based sensors offer the ability to obtain such data if it is demonstrated that these sensors and their associated transducers are resistant to high neutron flux, high gamma radiation, and high temperature. To address this need, the Advanced Test Reactor National Scientific User Facility (ATR-NSUF) is funding an irradiation, led by PSU, at the Massachusetts Institute of Technology Research Reactor to test the survivability of ultrasound transducers. As part of this effort, PSU and collaborators have designed, fabricated, and provided piezoelectric and magnetostrictive transducers that are optimized to perform in harsh, high flux, environments. Four piezoelectric transducers were fabricated with either aluminum nitride, zinc oxide, or bismuth titanate as the active element that were coupled to either Kovar or aluminum waveguides and two magnetostrictive transducers were fabricated with Remendur or Galfenol as the active elements. Pulse-echo ultrasonic measurements of these transducers are made in-situ. This paper will present an overview of the test design including selection criteria for candidate materials and optimization of test assembly parameters, data obtained from both out-of-pile and in-pile testing at elevated temperatures, and an assessment based on initial data of the expected performance of ultrasonic devices in irradiation conditions

Reinhardt1, Brian↗

Origins of radiation-induced optical attenuation in neutron-irradiated single-crystal sapphire at elevated temperatures

Sapphire (α-Al 2 O 3 ) is a candidate fiber-optic sensor material for extreme temperature environments, potentially including those of nuclear reactors. However, its optical transmission under high-dose neutron irradiation is not well understood compared with that of conventional fused silica. This study examined dimensional changes, optical transmission, and irradiation-induced defects in neutron-irradiated α-Al 2 O 3 at temperatures of 298 °C to 688 °C and doses of 3.2 to 12 dpa. Although previous studies attributed radiation-induced attenuation (RIA) at the highest irradiation temperatures to increased optical scattering from radiation-induced voids, our findings indicate that scattering from neither voids nor dislocation loops can explain the measured attenuation. Instead, absorption due to aluminum vacancy centers appears more likely based on a comparison of the spectral features of the measured optical attenuation with previous literature. Significant c-axis swelling (5.51 % ± 0.83 %) was observed in the 12 dpa, 592 °C irradiated sample, much higher than earlier measurements, suggesting temperature sensor drift of 543 °C to 1,140 °C. Void patterning was predominantly observed along the a-axis, differing from previous studies on polycrystalline samples, which showed c-axis patterning. Dislocation loops evolved into network dislocations with increasing temperature and dose; voids formed within these structures, showing no size or density changes, indicating an atypical growth mechanism.

Neutron irradiation↗

Towards Three-Dimensional Neutron Imaging with Light-field Technology

A broad range of applications in nuclear safeguards and security can benefit from compact, fast neutron imagers with large angular acceptance. However, accurate 3D multi-vertex reconstruction in a monolithic detector remains a significant barrier to realization. Current approaches, such as the centroiding approach and the use of shadow masks, have not yet resulted in a successful demonstration in a light-starved environment. This project explored the use of cutting-edge technology—a light field camera—which inherently preserves both the spatial and directional information of incident light. Such technology can, in principle, resolve multi-vertex events and offer accurate position reconstruction in 3D with relatively simple readout electronics. Since the project's inception in May 2023, we have built an experimental setup to calibrate and characterize a commercial light-field camera (Lytro Illum). We assessed its 3D event reconstruction capability in a relatively low-light intensity environment by analyzing the cross-correlation of a series of 2D images of a characterized tunable light source taken at various distances. A sub-cm resolution, lower than typical neutron interaction separations in a compact scintillator volume, was observed with the LED light source, suggesting the promising capability of its nominal optics design to provide the adequate resolution required for a compact monolithic neutron directional detector. However, using a light-field-based readout for a neutron camera requires incorporating an ultra-low-noise light sensor, which is beyond the scope of this project. We also initiated the development of a 3D light-field-based reconstruction algorithm tailored to sparse scenes, as expected from particle interactions in a scintillator medium. Additionally, we demonstrated the capability of the algorithm to replicate the ground truth. Finally, we began the development of a neutron directional detector simulation to determine the performance criteria for light-field-based reconstruction that allows for good neutron directional reconstruction. This Feasibility Study has led to a successful follow-up project under the DNN R&D innovation portfolio starting May 2024.

42 ENGINEERING↗

Ground calibration and in-flight commissioning of the Gamma-Ray and Neutron Spectrometer (GRNS) for NASA’s Psyche mission

NASA's Psyche spacecraft is currently enroute to the asteroid 16 Psyche, where it will perform an orbital investigation focused on determining the nature of the asteroid. A key part of this investigation is measurements of elemental composition to determine if the asteroid is rich in iron-nickel metal. To that end, the Psyche spacecraft payload includes a Gamma-Ray and Neutron Spectrometer (GRNS). GRNS is composed of two subsystems; a Gamma-Ray Spectrometer (GRS) with a high-purity germanium γ-ray sensor surrounded by a borated plastic scintillator Anti-Coincidence Shield (ACS), and a Neutron Spectrometer (NS) with three 3 He-filled gas proportional counters that are sensitive to different neutron energy regimes. We describe results from the pre-launch calibration campaign, along with early in-flight results from post-launch instrument commissioning. The information detailed here is focused on providing future users of GRNS data with the information needed to properly interpret the observations from the instrument.

Peplowski, Patrick N. [Johns Hopkins Univ., Baltim↗