Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Improved joint X-ray and neutron refinement procedure in Phenix

Neutron diffraction is one of the three crystallographic techniques (X-ray, neutron and electron diffraction) used to determine the atomic structures of molecules. Its particular strengths derive from the fact that H (and D) atoms are strong neutron scatterers, meaning that their positions, and thus protonation states, can be derived from crystallographic maps. However, because of technical limitations and experimental obstacles, the quality of neutron diffraction data is typically much poorer (completeness, resolution and signal to noise) than that of X-ray diffraction data for the same sample. Further, refinement is more complex as it usually requires additional parameters to describe the H (and D) atoms. The increase in the number of parameters may be mitigated by using the `riding hydrogen' refinement strategy, in which the positions of H atoms without a rotational degree of freedom are inferred from their neighboring heavy atoms. However, this does not address the issues related to poor data quality. Therefore, neutron structure determination often relies on the presence of an X-ray data set for joint X-ray and neutron (XN) refinement. In this approach, the X-ray data serve to compensate for the deficiencies of the neutron diffraction data by refining one model simultaneously against the X-ray and neutron data sets. To be applicable, it is assumed that both data sets are highly isomorphous, and preferably collected from the same crystals and at the same temperature. However, the approach has a number of limitations that are discussed in this work by comparing four separately re-refined neutron models. To address the limitations, a new method for joint XN refinement is introduced that optimizes two different models against the different data sets. This approach is tested using neutron models and data deposited in the Protein Data Bank. The efficacy of refining models with H atoms as riding or as individual atoms is also investigated.

36 MATERIALS SCIENCE↗

Critical and Subcritical Californium Source Driven Noise Analysis Experiments with Fresh PWR Fuels Pins

These experiments were performed in 1983 between August 1 and September 16 and used 35 operational days of critical facility time at the Babcock & Wilcox critical facility in Lynchburg, Va. These measurements were to assess the capability of the Cf source driven noise analysis method to measure the subcriticality of light water reactor fresh fuel configurations. This report documents the experiments of 1983 that were not reported at that time. These measurement with 2.459 wt. % 235 U enriched uranium oxide fresh fuel pins started at the delayed critical configuration of the fully assembled pressurized water reactor (PWR) core configuration with 1511 parts per million (ppm) natural boron (19.8 wt. % 10 B) in the water. This was a cylindrical configuration of 4961 fuel pins. After the initial measurements at delayed criticality, subcritical measurements by the Cf source driven noise analysis method were performed in which the number of detectors and Cf source locations were varied. Additional boron was added to the water moderator and reflector to reduce the neutron multiplication factor, with resulting boron concentrations of 1561, 1613, 1765, 1880, 2104, 2384, 2975, 3606, and 4303 ppm. After the completion of these measurements the increased, the boron concentration was returned to that at delayed critical (1511 ppm) and the reactivity was decreased by reducing the number of fuel pins in steps to 3713, 2553, 1281, 749, and 333 fuel pins and then to that (289) of a s ingle square 17 x 17 pin array, corresponding to a single PW fuel element. For all measurement that started at delayed criticality and then reduced the neutron multiplication factor to various subcritical states, inverse kinetics rod drop measurements at the higher reactivities were also performed but not reported here. At all subcritical states the break frequency noise analysis data was fitted to obtain the prompt neutron decay constant. Some data presented in this report are from notes not in the logbook. The purpose of this report is to document the experimental information for the measurements performed so that a later date someone could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (INCSBEP) or Nuclear Energy Agency (NEA) benchmark. The data from these measurements is available from the Laboratory Records Department of Oak Ridge National Laboratory and the logbook is available from INCSBEP at Idaho National Laboratory.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fast Hyperspectral Neutron Tomography

Hyperspectral neutron computed tomography is a tomographic imaging technique in which thousands of wavelength-specific neutron radiographs are measured for each tomographic view. In conventional hyperspectral reconstruction, data from each neutron wavelength bin are reconstructed separately, which is extremely time-consuming. These reconstructions often suffer from poor quality due to low signal-to-noise ratios. Consequently, material decomposition based on these reconstructions tends to produce inaccurate estimates of the material spectra and erroneous volumetric material separation. In this paper, we present two novel algorithms for processing hyperspectral neutron data: fast hyperspectral reconstruction and fast material decomposition. Both algorithms rely on a subspace decomposition procedure that transforms hyperspectral views into low-dimensional projection views within an intermediate subspace, where tomographic reconstruction is performed. The use of subspace decomposition dramatically reduces reconstruction time while reducing both noise and reconstruction artifacts. We apply our algorithms to both simulated and measured neutron data and demonstrate that they reduce computation and improve the quality of the results relative to conventional methods.

Chowdhury, Mohammad Samin Nur [Purdue University]↗

Observable properties of neutron stars

This paper reviews the information on neutron stars that has been obtained from observations of pulsars and pulsing X-ray stars, with emphasis on results from timing studies. Included are summaries of the most recent theoretical work on neutron star structure and the current evidence concerning neutron star masses and radii. Also included are discussions of large frequency jumps and small-scale timing irregularities, the description of the latter phenomenon in terms of random noise processes, and the use of both as probes of the internal structure and dynamical properties of neutron stars. Finally, some of the most promising directions for future work are briefly noted.

Lamb, F. K.↗

Probing the interiors of neutron stars

This paper reviews the information on neutron stars that has been obtained from observations of pulsars and pulsing X-ray stars, with emphasis on results from timing studies. Included are summaries of the most recent theoretical work on neutron star structure and the current evidence concerning neutron star masses and radii. Also included are discussions of large frequency jumps and small-scale timing irregularities, the description of the latter phenomenon in terms of random noise processes, and the use of both as probes of the internal structure and dynamical properties of neutron stars. Finally, some of the most promising directions for future work are briefly noted.

Lamb, F. K.↗

From noise to information: The transfer function formalism for uncertainty quantification in reconstructing the nuclear density

The neutron distribution of neutron-rich nuclei provides critical information on the structure of finite nuclei and neutron stars. Parity violating experiments—such as PREX and CREX—provide a clean and largely model-independent determination of neutron densities. Such experiments, however, are challenging and expensive, which is why sound statistical arguments are required to maximize the information gained. We introduce a new framework, the “transfer function formalism,” aimed at uncertainty quantification, model selection, and experimental design in the context of neutron densities. The transfer functions (TFs) are built analytically by expressing the linear response of the objective function (e.g., χ2) to small perturbations of the data. Using the TF formalism, we are able to analyze the expected overall uncertainty—quantified in terms of bias and variance—of the mean square radius and interior density of 48 Ca and 208 Pb. Using relativistic mean field models as a proxy for the weak-charge density—and assuming that a total of five measurements could be performed on the weak form factor of 48 Ca and 208 Pb—we identify the optimal models and experimental locations that minimize the uncertainty in the extraction of the radius and interior density. We also explore the use of the TF formalism to understand the influence of prior distributions for the model parameters, as well as the optimization of model hyperparameters not constrained by the data. Here,we establish how the choice of experimental locations and the model that is used can have a significant impact on the final uncertainties of the extracted quantities of interest. For challenging experiments such as CREX and PREX, a proper quantification of such uncertainties is critical. We have demonstrated how the TF formalism provides several advantages for this type of analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Infrared MBE-Grown HgCdTe Focal Plane Arrays and Cameras After High Energy Neutron Irradiation

HgCdTe is one of the most important materials for the fabrication of infrared detectors and focal plane arrays (FPAs) deployed in environments where high-energy particles, such as protons and neutrons, are present. We designed and fabricated HgCdTe-based FPAs that can be used in high neutron radiation environments and we measured their characteristics. The influence of the radiation on the infrared FPAs and cameras is investigated. HgCdTe material and devices are capable of maintaining high performances in a high energy neutron irradiation environment. For MWIR FPA directly facing a $2.59 × 10^8$ n/cm$^2$ s neutron flux beam (with the highest energy 66 MeV) for 1 h, the noise equivalent differential temperature (NEDT) increased ~8 times after irradiation. However, NEDT decreased to 33 mK (compared to the original value of 21 mK) after one warming-up (to room temperature) and cooling-down cycle. The NEDT for the MWIR FPAs mounted parallel to the beam did not degrade (16 mK and 28 mK before irradiation, changed to 18 mK and 26 mK after irradiation, respectively).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing the spatial resolution and gamma discrimination of SiPM-based Anger cameras

SiPM Anger cameras have been designed for use as 2-dimensional thermal neutron detectors for scientific applications such as at single crystal diffraction instruments. These cameras utilize a neutron sensitive scintillator and an array of SiPM photosensors, separated by a light spreading glass. While this optics package is very effective at detecting and positioning neutrons, it is also sensitive to gamma rays, which are a source of unwanted noise. In this work, we underwent a search of scintillator and spreader glass thicknesses to determine the optimal combination for maximizing spatial resolution. Both experimental results and GEANT4 simulations are presented. Further, to address the issue of gamma ray detection, we have also designed and presented a multi-layer scintillator that reduces the amount of scintillation light produced via gamma-ray energy deposition, allowing for easier pulse-height discrimination. A sample of this geometry has been produced that results in a factor of 2 improvement over an equivalent thickness monolithic scintillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Desmearing Bonse–Hart USANS data using Bayesian Gaussian process regression

Ultra-small-angle neutron scattering (USANS) enables access to micrometer-scale structures but is intrinsically affected by strong, anisotropic resolution smearing arising from slit-geometry optics. As a result, recovery of the intrinsic scattering intensity constitutes an ill-posed inverse problem, and commonly used iterative desmearing methods lack rigorous uncertainty quantification. We present a Bayesian desmearing framework for slit-geometry USANS based on Gaussian process regression. In this approach, the scattering intensity is modeled as a smooth random function, and the instrumental point spread function is incorporated explicitly as a forward operator. The resulting formulation yields a closed-form maximum a posteriori solution with well-defined credibility intervals. Computational benchmarks and experimental validation using combined USANS and small-angle neutron scattering (SANS) measurements demonstrate that the framework enables stable desmearing, suppresses experimental noise, and preserves physically meaningful structural features under realistic conditions.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN↗

Spontaneous superfluid unpinning and the inhomogeneous distribution of vortex lines in neutron stars

The equation of motion of the pinned superfluid which couples to the crust of neutron stars via thermal vortex creep is studied. Spontaneous unpinning at locations characterized by a very inhomogeneous distribution of vortex lines is examined as a possible mechanism for the initiation of glitches. It is suggested that structural inhomogeneities in the crust of neutron stars may be responsible for frequent microglitches which lead to pulsar timing noise. A generalization of the model shows promise for explaining the origin of the giant glitches in pulsars.

Cheng, K. S.↗

Neutron Stars and Black Holes Seen with the Rossi X-Ray Timing Explorer (RXTE)

Astrophysical X-rays bring information about location, energy, time, and polarization. X-rays from compact objects were seen in the first explorations to vary in time. Eclipses and pulsations have simple explanations that identified the importance of X-ray binaries and magnetic neutron stars in the first decade of X-ray astronomy. The dynamics of accretion onto stellar and supermassive black holes and onto neutron stars with relatively low magnetic fields shows up as more complex variations, quasi-periodic oscillations, noise with characteristic frequency spectra, broad-band changes in the energy spectra. To study these variations, RXTE instruments needed to have large area and operational flexibility to find transient activity and observe when it was present. Proportional counters and Phoswich scintillators provided it in a modest mission that has made textbook level contributions to understanding of compact objects. The first seen, and the brightest known, X-ray binary, Sco X-1 is one of a class of neutron stars with low mass companions. Before RXTE, none of these had been seen to show pulsations, though they were hypothesized to be the precursors of radio pulsars with millisecond periods and low magnetic fields. RXTE's large area led to identifying coherent millisecond pulsars in a subset which are relatively faint transients. It also led to identifying short episodes of pulsation during thermonuclear bursts, in sources where a steady signal is not seen. The X-ray stage verifies the evolution that produces millisecond radio pulsars.Masses and radii of neutron stars are being determined by various techniques, constraining the equation of state of matter at nuclear densities. Accretion should lead to a range of neutron star masses. An early stage of superstrong magnetic field neutron stars is now known to produce X-ray and gamma-ray bursts in crust quakes and magnetic field reconnection releases of energy. Soft Gamma Repeaters, Anomolous X-ray Pulsars, and high magnetic field rotation-powered pulsars are all now called magnetars, because they have pulse periods indicating they are slowing down as they would with magnetic dipole radiation for a surface field above 5x1013 gauss. The accretion disk has been connected to the launching of radio jets from black holes, and even from neutron stars. Estimates of the angular momenta of black holes are being made from different approaches, modelling a high frequency oscillation that may be related to how close the inner part of the accretion disk is to the black hole, modelling the continua spectra of the X-ray emission, and modeling the emission of red-shifted iron that may be emitted from the accretion disk. These investigations require early discovery of the black hole transient with the All Sky Monitor on RXTE or other monitoring information, frequent extended observations, and coordinated observations with missions that give higher energy resolution, or radio and infrared information.

Swank, Jean↗

Quantum Interferometry

Recently, several researchers, including yours truly, have been able to demonstrate theoretically that quantum photon entanglement has the potential to also revolutionize the entire field of optical interferometry, by providing many orders of magnitude improvement in interferometer sensitivity. The quantum entangled photon interferometer approach is very general and applies to many types of interferometers. In particular, without nonlocal entanglement, a generic classical interferometer has a statistical-sampling shot-noise limited sensitivity that scales like 1/Sqrt[N], where N is the number of particles (photons, electrons, atoms, neutrons) passing through the interferometer per unit time. However, if carefully prepared quantum correlations are engineered between the particles, then the interferometer sensitivity improves by a factor of Sqrt[N] (square root of N) to scale like 1/N, which is the limit imposed by the Heisenberg Uncertainty Principle. For optical (laser) interferometers operating at milliwatts of optical power, this quantum sensitivity boost corresponds to an eight-order-of-magnitude improvement of signal to noise. Applications are to tests of General Relativity such as ground and orbiting optical interferometers for gravity wave detection, Laser Interferometer Gravity Observatory (LIGO) and the European Laser Interferometer Space Antenna (LISA), respectively.

Dowling, Jonathan P.↗

Period variations in pulsating X-ray sources. I - Accretion flow parameters and neutron star structure from timing observations

Torque fluctuations which can lead to variations in the periods of pulsating X-ray sources are examined. A description of torque variations in terms of noise processes is developed, and the resulting noise models are applied to observations of several pulsating X-ray sources. It is shown that fluctuations in accretion torque could account for the observed period variations and spindown episodes in Her X-1 and Cen X-3. The values of the torque noise strengths inferred from either a nonresonant response or, in the case of Her X-1, a Tkachenko-mode interpretation of the data are found to be consistent with those expected from processes at the magnetospheric boundary of an accreting neutron star. Ways to distinguish among the various interpretations of the period variations are considered. It is noted that fluctuating mass-flow rates may be responsible for other phenomena observed in compact X-ray sources, such as wobble with zero initial amplitude and binary period variations in close binary systems experiencing mass transfer.

Lamb, F. K.↗

Quantification of Sub-Pixel Dynamics in High-Speed Neutron Imaging

The high penetration depth of neutrons through many metals and other common materials makes neutron imaging an attractive method for non-destructively probing the internal structure and dynamics of objects or systems that may not be accessible by conventional means, such as X-ray or optical imaging. While neutron imaging has been demonstrated to achieve a spatial resolution below 10 μm and temporal resolution below 10 μs, the relatively low flux of neutron sources and the limitations of existing neutron detectors have, until now, dictated that these cannot be achieved simultaneously, which substantially restricts the applicability of neutron imaging to many fields of research that could otherwise benefit from its unique capabilities. In this work, we present an attenuation modeling approach to the quantification of sub-pixel dynamics in cyclic ensemble neutron image sequences of an automotive gasoline direct injector at a 5 μs time scale with a spatial noise floor in the order of 5 μm.

47 OTHER INSTRUMENTATION↗

Closed-Loop Performance Measures for Flight Controllers Subject to Neutron-Induced Upsets

It has been observed that atmospheric neutrons can produce single event upsets in digital flight control hardware. The phenomenon has been studied extensively at the chip level, and now system level experiments are underway. In this paper analytical closed-loop performance measures for the tracking error are developed for a plant that is stabilized by a recoverable computer system subject to neutron induced upsets. The underlying model is a Markov jump-linear system with process noise. The steady-state tracking error is expressed in terms of a generalized observability Gramian.

Gray, W. Steven↗