Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NbS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Quantum efficiency of opaque CsI photocathodes with channel electron multiplier arrays in the extreme and far ultraviolet

The arrays are overcoated with a CsI photocathode in the VUV. The measurements are part of the development program for the Extreme Ultraviolet Explorer. Monochromatic light from a hollow cathode discharge source passing through a McPherson grazing incidence monochromator is used to illuminate the CsI photocathode. The beam diameter is kept small (approximately 2 mm) to confine it within the individual thickness strips. A bias grid is used to produce a 50-V/mm electric field to guarantee collection of all photoelectrons emitted by the CEMA (channel electron multiplier array) webbing. The CEMAs are operated with a gain of 2-3 x 10 to the 6th and are moderately saturated. A channeltron secondary transfer standard is used to determine the absolute QE in the EUV, whereas an NBS calibrated windowed photodiode is used to measure the FUV absolute QE. It is noted that the CsI gives a factor of 3 increase in the QE in the EUV and a factor of 50-5000 in the FUV.

Martin, C.↗

A compact hydrogen maser with exceptional long-term stability

A passive hydrogen maser employing a smaller microwave cavity than previous masers is described. The volume of the entire resonator package, including a conventional source, hexapole state selector, and four magnetic shields, is estimated at 20 liters. The techniques for constructing the ceramic cavity, coating it with FEP, and attaching the endcaps to achieve a stable container (to allow its use as a single vacuum system) are described in detail. Frequency stability measurements were made of four such masers, against an NBS-4 cesium primary standard, against each other, and against eight commercial cesium clocks; frequency stability level is reported as 1.7 x 10 to the -12th tau exp -1/2 from 1 to 100,000 sec, and no drift above 1 x 10 to the -15th/day was found. Pressure and temperature effects on frequency stability were found at the 1 x 10 to the -14th level. Noise behavior beyond 200,000 sec is characterized as random walk. The potential use of a compact stable maser as a clock is suggested.

Howe, D. A.↗

Heterodyne frequency measurements and frequency calibration standards for tunable diode lasers

New frequency calibration tables are required to keep abreast of the resolution attainable by currently available tunable lasers. One key to the generation of tables with requisite accuracy involves accurate heterodyne frequency measurements; another key consists of reliable fitting and analysis. Coordinated activity in NBS involves selection of suitable molecular calibration candidates, their frequency measurement and analysis, and dissemination of the results in the form of frequency calibration tables. Current status of these efforts is described.

Wells, J. S.↗

First results of GPS time transfer to Australia

A Global Positioning System time transfer unit built by NBS under contract to JPL was installed at Tidbinbilla Deep Space Communications Complex of the NASA Deep Space Network in June 1983. It has been used to estimate the relationship to UTC(USNO MC) of the Tidbinbilla frequency and time system TID(FTS) based on a hydrogen maser, and thence to estimate the performance of the Australian free-running time scale UTC(AUS). Data from the first three months has been analyzed three ways: by two-hop common view using JPL as intermediary; by long-arc interpolation of measurements against space vehicle clocks; and by long-arc interpolation of GPS-Time results. Residuals from a single quadratic fit through three months of UTC(USNO MC) - TID (FTS) results were white noise with standard error 15 ns, and a flying clock measurement gave 70 ns agreement. A straight line fit through results UTC(USNO MC) - UTC (AUS) gave 90 ns standard error and 120 bns agreement. It is proposed to use the GPS measurements to steer UTS(AUS) to UTC(BIH), and to rename the existing time scale TA(AUS).

Luck, J. M.↗

The design, fabrication and delivery of a manipulator foot restraint mockup for space telescope development testing

The Manipulator Foot Restraint (MFR) is a subsystem of the Remote Manipulator System (RMS) which plays a major role in servicing the Hubble Space Telescope (HST) in orbit. Flight drawings were used to construct the MFR to guarantee that the mockup components were functionally equivalent to the flight MFR. Material surface finishes and tolerances that were compatible to the Neutral Buoyance Simulator (NBS) environment were used. Recommendation for improvements are discussed.

Hollingsworth, M. A.↗

World-wide increase in tropospheric methane, 1978-1983

Techniques used to assess methane concentration in the troposphere are described, and data obtained during the period from 1978 to 1983 are presented in detail. Tropospheric methane concentrations in remote locations averaged a yearly world-wide increase of 0.018 + or - 0.002 parts per million by volume (ppmv). Average world-wide tropospheric concentration of methane in dry air was 1.625 ppmv at the end of 1983 measured against an NBS standard certified as 0.97 ppmv. Contributing to this steady increase in methane concentration are increases in the source strengths from cattle and rice fields, which in turn result from CO, CH4 and HO coupling. Among the physical and chemical effects is an increase in greenhouse warming of about 0.04 C per decade.

Blake, D. R.↗

Results from the Balloon Ozone Intercomparison Campaign (BOIC)

In the Balloon Ozone Intercomparison Campaign (BOIC), several in situ UV absorption photometers, two solar UV absorption photometers, electrochemical sondes, and a mass spectrometer were intercompared in three flight missions. Concurrent data from Umkehr and satellite observations are also intercompared. The National Bureau of Standards provided a 'standard' ozone source for intercomparing the in situ instruments and ground pressure. Preliminary findings indicate that the standard deviation of the sensitivities among 17 instruments against the NBS reference was about 11 percent. These differences appear in flight at the lower levels and change at higher altitudes, indicating height-dependent errors. The difference among five in-situ UV photometers flown together ranged by plus or minus 8 percent during ascent to about 41 km. During float at 42 km, the difference nearly doubled. During descent, the difference decreased to about 4 percent, which is much closer to the expected accuracy of these instruments. Results from UV solar radiometers have been systematically higher than those from UV photometers by 15 to 20 percent - a very important disagreement that needs to be resolved.

Hilsenrath, E.↗

Air- and oxygen-broadening coefficients for the O2 rotational line at 60.46/cm

Using an NBS laser-based tunable far-infrared spectrometer, the air- and oxygen-broadening coefficients were measured for the J = 10 - 10, N = 11 - 9 O2 rotational transition at 60.46/cm (1.812 THz). The air-broadening coefficient is 5.04 + or - 0.38 x 10 to the -7th/cm/Pa (0.0511 + or - 0.0039/cm/atm) (HWHM) at 245 + or - 6 K; the oxygen-broadening coefficient is 4.92 + or - 0.47 x 10 to the -7th/cm/Pa (0.0499 + or - 0.0048/cm/atm) (HWHM) at 259 + or -2 K. These direct experimental measurements of the air-broadening coefficient should improve the accuracy of retrieval calculations for far-infrared stratospheric balloon experiments which use O2 rotational lines to calibrate the viewing geometry.

Jennings, D. A.↗

The soft X-ray/EUV calibration facility at the University of Colorado

The components of the calibration facility at the University of Colorado are described. The system is capable of analyzing the performance of optical components in the wavelength range from 2.7 to 2500 A. The system uses two light sources: a water-cooled hollow cathode gas discharge source and a soft X-ray source. The 2.2-m grazing incidence monochrometer, slits, large chamber, and computer-controlled manipulator are examined. The NBS aluminum oxide photodiode, a flowing gas proportional counter, and an imaging microchannel plate device are employed to detect the light. The optics, detectors, and data acquisition system are computer controlled. The facility is applicable for evaluating the performance of diffraction gratings, multilayer mirrors, reflective coatings, spectrographs, surface roughness scattering, and absolute detector efficiencies. Examples demonstrating the capabilities of the facility and a diagram of the facility are presented.

Windt, David L.↗

Radiometric calibrations of portable sources in the vacuum ultraviolet

The primary UV radiometric calibration standards of the Atomic and Plasma Radiation Division of the NBS are the hydrogen arc and the blackbody line arc. The secondary standards are the argon mini- and maxiarcs, and the deuterium arc lamp. Calibration methods involving both spectral radiance and irradiance, as well as the evaluation of their uncertainties, are discussed. Attention is given to the establishment of an irradiance scale, and the absolute spectral irradiance, measured as a function of wavelength, at a 50-cm distance from the field aperture for five different continuum sources.

Klose, Jules Z.↗

Theoretical studies of the monoxides and monosulfides of Y, Zr, and Nb

Modified-CPF and CASSCF/multireference-CI theoretical calculations are presented for the ground and low-lying states of YO and YS, ZrO and ZS, and NbO and NbS. The techniques employed are explained, and the calculated spectroscopic constants are presented in extensive tables. Good agreement is found with published experimental data on the oxides, and it is inferred that the sulfide results are accurate as well. Particular attention is given to the high-lying quartet manifold of states in YO and the (1) 3Pi-a3Delta transition of ZrS (possibly the source of the IR Keenan bands seen in S-star spectra).

Langhoff, Stephen R.↗

Radiance standards

Two radiometric calibration sources that are utilized by various groups are maintained and operated. One source is a 6-ft diameter sphere and the other a 4-ft diameter hemisphere. Both are internally coated with multiple layers of barium sulfate and house an array of 12 tungsten filament-quartz iodine lamps that provide a uniform diffuse target of radiance traceable to NBS. The lamps are baffled and arranged so that they are not part of the scene during calibrations. Both systems have a 10-inch viewing aperture. The hemisphere is somewhat more versatile in that the aperture can be changed and the system is movable so calibrations can be done at other sites. Together, these systems have supported numerous GSFC projects and missions during this review period. They are listed.

Lester, D. L.↗

X-ray fluorescence analysis of alloy and stainless steels using a mercuric iodide detector

A mercuric iodide detector was used for the XRF analysis of a number of NBS standard steels, applying a specially developed correction method for interelemental effects. It is shown that, using this method and a good peak-deconvolution technique, the HgI2 detector is capable of achieving resolutions and count rates needed in the XRF anlysis of multielement samples. The freedom from cryogenic cooling and from power supplies necessary for an electrically cooled device makes this detector a very good candidate for a portable instrument.

Kelliher, Warren C.↗

Laboratory calibration of field reflectance panels

A method used for calibrating field reflectance panels in the visible and shortwave infrared wavelength range is described. The directional reflectance factor of painted barium sulfate (BaSO4) panels is determined. The reference for this method is the hemispherical reflectance of pressed polytetrafluoroethylene (halon) powder prepared according to National Bureau of Standards (NBS) directions. The panels and a radiometer are mounted on rotation stages to measure the reflectance factor at different incidence and view angles. The sensor can be any laboratory or field filter radiometer small enough to mount on the apparatus. The method is used to measure the reflectance factors of halon and BaSO4 panels between 0.45 and 0.85 micrometers. These reflectance factors are compared to those measured by a field apparatus. The results agree to within 0.013 in reflectance at incidence angles between 15 and 75 degrees.

Biggar, S. F.↗

The Berkeley extreme ultraviolet calibration facility

The vacuum calibration facilities of the Space Sciences Laboratory, University of California at Berkeley are designed for the calibration and testing of EUV and FUV spaceborne instrumentation (spectral range 44-2500 A). The facility includes one large cylindrical vacuum chamber (3 x 5 m) containing two EUV collimators, and it is equipped with a 4-axis manipulator of angular-control resolution 1 arcsec for payloads weighing up to 500 kg. In addition, two smaller cylindrical chambers, each 0.9 x 1.2 m, are available for vacuum and thermal testing of UV detectors, filters, and space electronics hardware. All three chambers open into class-10,000 clean rooms, and all calibrations are referred to NBS secondary standards.

Welsh, Barry Y.↗

NASA/GSFC split-rail parallel gripper

The current state of development of the NASA/GSFC (Goddard Space Flight Center) Split-Rail Parallel Gripper (SRPG) is described. The SPRG has been shown to be a high performance gripper for industrial robots. It has a precise wide throw and at the same time, it is light, simple, compact, rugged, and jam-proof against side loads. Originated at the National Bureau of Standards (NBS), this gripper is undergoing further development at NASA/GSFC in pursuit of two goals: as a potential gripper for robots in space and as the basis for sensory-interactive industrial gripper as part of NASA's technology utilization program. The gripper design features, its principles of operation and how it is constructed are described. Test results are included.

Vranish, John M.↗

Program Supplies Properties Of Parahydrogen

National Bureau of Standards Parahydrogen Properties Database (NBS+_PH2) computer program developed to provide selected thermal and transport properties of parahydrogen matching 1981 parahydrogen data of National Bureau of Standards (now called National Institute of Standards and Technology). Created to be linked with propulsion-simulation programs, which require mathematical model of parahydrogen covering wide range of pressures and temperatures. Provides data on parahydrogen for pressures from 10 kPa to 16 MPa and temperatures from 20 to 104 K. Provides following properties: density, thermal conductivity, viscosity, Prandtl number, enthalpy, specific heat, and speed of sound. Written in FORTRAN 77.

Walton, J. T.↗