Real-time automatic fiducial marker tracking in low contrast cine-MV images

Purpose: To develop a real-time automatic method for tracking implanted radiographic markers in low-contrast cine-MV patient images used in image-guided radiation therapy (IGRT). Methods: Intrafraction motion tracking using radiotherapy beam-line MV images have gained some attention recently in IGRT because no additional imaging dose is introduced. However, MV images have much lower contrast than kV images, therefore a robust and automatic algorithm for marker detection in MV images is a prerequisite. Previous marker detection methods are all based on template matching or its derivatives. Template matching needs to match object shape that changes significantly for different implantation and projection angle. While these methods require a large number of templates to cover various situations, they are often forced to use a smaller number of templates to reduce the computation load because their methods all require exhaustive search in the region of interest. The authors solve this problem by synergetic use of modern but well-tested computer vision and artificial intelligence techniques; specifically the authors detect implanted markers utilizing discriminant analysis for initialization and use mean-shift feature space analysis for sequential tracking. This novel approach avoids exhaustive search by exploiting the temporal correlation between consecutive frames and makes it possible to perform more sophisticated detection at the beginning to improve the accuracy, followed by ultrafast sequential tracking after the initialization. The method was evaluated and validated using 1149 cine-MV images from two prostate IGRT patients and compared with manual marker detection results from six researchers. The average of the manual detection results is considered as the ground truth for comparisons. Results: The average root-mean-square errors of our real-time automatic tracking method from the ground truth are 1.9 and 2.1 pixels for the two patients (0.26 mm/pixel). The standard deviations of the results from the 6 researchers are 2.3 and 2.6 pixels. The proposed framework takes about 128 ms to detect four markers in the first MV images and about 23 ms to track these markers in each of the subsequent images. Conclusions: The unified framework for tracking of multiple markers presented here can achieve marker detection accuracy similar to manual detection even in low-contrast cine-MV images. It can cope with shape deformations of fiducial markers at different gantry angles. The fast processing speed reduces the image processing portion of the system latency, therefore can improve the performance of real-time motion compensation.

60 APPLIED LIFE SCIENCES↗

TH-AB-202-07: Radar Tracking of Respiratory Motion in Real Time

Purpose: To propose a method of real time tracking of respiratory motion in patients undergoing radiation therapy. Radar technology can be employed to detection the movement of diaphragm and thoracic anatomy. Methods: A radar transceiver was specially designed. During experiment, the radar device was securely attached to a fixed frame. Respiratory motion was simulated with: 1) Varian RPM phantom, 2) Standard Imaging Respiratory Gating Platform. Signals recorded with radar equipment were compared with those measured with Varian RPM system as a reference. Results: Motion generated by Varian RPM phantom was recorded by the radar device, and compared to the signals recorded by RPM camera. The results showed exact agreement between the two monitoring equipments. Motion was also generated by Standard Imaging Respiratory Motion Platform. The results showed the radar device was capable of measuring motion of various amplitudes and periods. Conclusion: The proposed radar device is able to measure movements such as respiratory motion. Compared to state-of-the-art respiratory detection instrument, the radar device is shown to be equally precise and effective for monitoring respiration in radiation oncology patients.

60 APPLIED LIFE SCIENCES↗

Motion Dynamics of Motile Microbes in Pore-Networks and its Implications for Reactive Transport Processes

This report outlines new methods to improve simulations of microbial transport and microbially mediated reactions in porous media. A range of experimental, modeling, and machine learning tools are introduced to make these simulations faster, more reliable, and useful for real-world applications. At the microscopic level, the study investigates how different types of bacteria move through confined spaces. A new artificial intelligence tool called DeepTrackStat, is introduced to track motions dynamics as observed in videos of particles migrating through pore networks. This tool is especially helpful for studying fast-moving microbes and requires less computing power than traditional tracking methods. At larger scales, the research looks at how microbes and chemicals interact in zones where surface water and groundwater meet. To connect the small- and large-scale findings, the study presents a neural network model called STAMNet. This tool helps scale up detailed small-scale microbial motion behaviors to predict large-scale environmental changes more efficiently. By combining lab experiments, computer models, and artificial intelligence, the research presented supports smarter environmental decision-making, especially in bioremediation of contaminated groundwater and protection of water quality.

54 ENVIRONMENTAL SCIENCES↗

Nonlinear automatic landing control of unmanned aerial vehicles on moving platforms via a 3D laser radar

This paper presents a motion tracking and control system for automatically landing Unmanned Aerial Vehicles (UAVs) on an oscillating platform using Laser Radar (LADAR) observations. The system itself is assumed to be mounted on a ship deck. A full nonlinear mathematical model is first introduced for the UAV. The ship motion is characterized by a Fourier transform based method which includes a realistic characterization of the sea waves. LADAR observation models are introduced and an algorithm to process those observations for yielding the relative state between the vessel and the UAV is presented, from which the UAV's state relative to an inertial frame can be obtained and used for feedback purposes. A sliding mode control algorithm is derived for tracking a landing trajectory defined by a set of desired waypoints. An extended Kalman filter (EKF) is proposed to account for process and observation noises in the design of a state estimator. The effectiveness of the control algorithm is illustrated through a simulation example.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Clinical development of a failure detection-based online repositioning strategy for prostate IMRT--Experiments, simulation, and dosimetry study

Purpose: To implement and evaluate clinic-ready adaptive imaging protocols for online patient repositioning (motion tracking) during prostate IMRT using treatment beam imaging supplemented by minimal, as-needed use of on-board kV. Methods: The authors examine the two-step decision-making strategy: (1) Use cine-MV imaging and online-updated characterization of prostate motion to detect target motion that is potentially beyond a predefined threshold and (2) use paired MV-kV 3D localization to determine overthreshold displacement and, if needed, reposition the patient. Two levels of clinical implementation were evaluated: (1) Field-by-field based motion correction for present-day linacs and (2) instantaneous repositioning for new-generation linacs with capabilities of simultaneous MV-kV imaging and remote automatic couch control during treatment delivery. Experiments were performed on a Varian Trilogy linac in clinical mode using a 4D motion phantom programed with prostate motion trajectories taken from patient data. Dosimetric impact was examined using a 2D ion chamber array. Simulations were done for 536 trajectories from 17 patients. Results: Despite the loss of marker detection efficiency caused by the MLC leaves sometimes obscuring the field at the marker's projected position on the MV imager, the field-by-field correction halved (from 23% to 10%) the mean percentage of time that target displacement exceeded a 3 mm threshold, as compared to no intervention. This was achieved at minimal cost in additional imaging (average of one MV-kV pair per two to three treatment fractions) and with a very small number of repositionings (once every four to five fractions). Also with low kV usage ({approx}2/fraction), the instantaneous repositioning approach reduced overthreshold time by more than 75% (23% to 5%) even with severe MLC blockage as often encountered in current IMRT and could reduce the overthreshold time tenfold (to <2%) if the MLC blockage problem were relieved. The information acquired for repositioning using combined MV-kV images was found to have submillimeter accuracy. Conclusions: This work demonstrated with a current clinical setup that substantial reduction of adverse targeting effects of intrafraction prostate motion can be realized. The proposed adaptive imaging strategy incurs minimal imaging dose to the patient as compared to other stereoscopic imaging techniques.

60 APPLIED LIFE SCIENCES↗

SU-E-T-648: Quality Assurance Using the RADPOS System for 4D Radiotherapy with CyberKnife

Purpose: The CyberKnife robotic radiosurgery system uses Synchrony respiratory motion compensation, which requires independent performance verification. In this work, the RADPOS 4D dosimetry system’s motion measurements are compared with internal fiducial position measurements. In addition, RADPOS measurements are compared with Synchrony’s predictive correlation model, which is based on internal fiducial and external LED marker position measurements. Methods: A treatment plan was created for a lung insert containing fiducials, RADPOS detector, and Solid Water tumor phantom. Two Quasar Respiratory Motion Phantoms (Q1 and Q2) and two RADPOS detectors (R1 and R2) were used: Q1 simulated lung motion with a lung insert moving in the superior/inferior direction, while Q2 simulated chest motion with a chest platform moving in the anterior/posterior direction. Before treatment, R1 was secured inside of the tumor phantom within Q1, while LED markers and R2 were positioned on the chest platform of Q2. Two treatment delivery cases were studied: isocentric plan (I) and non-isocentric patient plan (P). Four motion cases were studied: no motion (0), sinusoidal and in-phase (1), sinusoidal and out-of-phase (2), patient waveform and out-of-phase (3). A coordinate alignment algorithm was implemented, allowing RADPOS and model position data to be compared within the fiducial coordinate system. Results: The standard deviation of the differences between RADPOS and fiducial position measurements was below 0.6 mm for all experimental cases. The standard deviation of the differences between RADPOS and model position data was 1.0, 1.5, and 1.6 mm along the primary direction of motion for case I1, I2, and P3, respectively. Conclusion: Our work demonstrates that RADPOS is a useful tool for independent quality assurance of CyberKnife treatment with Synchrony respiratory compensation. RADPOS and fiducial position measurement closely match, and RADPOS confirms the effectiveness of CyberKnife’s Synchrony motion tracking. This work was supported by OCAIRO (Ontario Consortium for Adaptive Interventions in Radiation Oncology) grant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In-situ L-TEM observations of dynamics of nanometric skyrmions and antiskyrmions

Nanometer-scale magnetic skyrmions and antiskyrmions exhibit unique dynamical behaviors in response to external stimuli, which are critical for their applications in low-power-consumption spintronic devices. This review discusses recent advancements in in-situ Lorentz transmission electron microscopy (L-TEM) observations of skyrmion and antiskyrmion dynamics, and demonstrates the manipulation and evolution of these textures in various magnetic materials under electric, magnetic, and thermal stimuli. Specifically, the motion tracking of single skyrmions and their clusters, and the deformation and transformation of skyrmions has been demonstrated in chiral helimagnets FeGe, Co 9 Zn 9 Mn 2 , and Co 10 Zn 10 with precise application of electric currents. Skyrmions can undergo dynamic transitions in current-driven skyrmion motions, from pinned states to linear flows, and even exhibit deformation into elliptical shapes, underscoring their topological robustness and dynamic flexibility. In addition, the manipulation of single antiskyrmions and antiskyrmion-lattice phases in (Fe 0.63 Ni 0.3 Pd 0.07 ) 3 P with S 4 symmetry is discussed, highlighting their high mobility and unique sliding capabilities along stripe domains at room temperature, facilitated by nanosecond pulsed electric currents. Finally, the temperature gradient-driven motion and topological transformation of elliptical skyrmions and antiskyrmions in this same material are investigated. In conclusion, the comprehensive insights gained from the L-TEM imaging technique are pivotal in advancing the design and functionality of next-generation skyrmion/antiskyrmion-based spintronic devices.

(Anti)skyrmion↗

Intrafraction Prostate Translations and Rotations During Hypofractionated Robotic Radiation Surgery: Dosimetric Impact of Correction Strategies and Margins

Purpose: To investigate the dosimetric impact of intrafraction prostate motion and the effect of robot correction strategies for hypofractionated CyberKnife treatments with a simultaneously integrated boost. Methods and Materials: A total of 548 real-time prostate motion tracks from 17 patients were available for dosimetric simulations of CyberKnife treatments, in which various correction strategies were included. Fixed time intervals between imaging/correction (15, 60, 180, and 360 seconds) were simulated, as well as adaptive timing (ie, the time interval reduced from 60 to 15 seconds in case prostate motion exceeded 3 mm or 2° in consecutive images). The simulated extent of robot corrections was also varied: no corrections, translational corrections only, and translational corrections combined with rotational corrections up to 5°, 10°, and perfect rotational correction. The correction strategies were evaluated for treatment plans with a 0-mm or 3-mm margin around the clinical target volume (CTV). We recorded CTV coverage (V{sub 100%}) and dose-volume parameters of the peripheral zone (boost), rectum, bladder, and urethra. Results: Planned dose parameters were increasingly preserved with larger extents of robot corrections. A time interval between corrections of 60 to 180 seconds provided optimal preservation of CTV coverage. To achieve 98% CTV coverage in 98% of the treatments, translational and rotational corrections up to 10° were required for the 0-mm margin plans, whereas translational and rotational corrections up to 5° were required for the 3-mm margin plans. Rectum and bladder were spared considerably better in the 0-mm margin plans. Adaptive timing did not improve delivered dose. Conclusions: Intrafraction prostate motion substantially affected the delivered dose but was compensated for effectively by robot corrections using a time interval of 60 to 180 seconds. A 0-mm margin required larger extents of additional rotational corrections than a 3-mm margin but resulted in lower doses to rectum and bladder.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The total mass of the Large Magellanic Cloud from its perturbation on the Orphan stream

In a companion paper by Koposov et al., RR Lyrae from Gaia Data Release 2 are used to demonstrate that stars in the Orphan stream have velocity vectors significantly misaligned with the stream track, suggesting that it has received a large gravitational perturbation from a satellite of the Milky Way. We argue that such a mismatch cannot arise due to any realistic static Milky Way potential and then explore the perturbative effects of the Large Magellanic Cloud (LMC). We find that the LMC can produce precisely, the observed motion-track mismatch and we therefore use the Orphan stream to measure the mass of the Cloud. We simultaneously fit the Milky Way and LMC potentials and infer that a total LMC mass of |$1.38^{+0.27}_{-0.24} \times 10^{11}\, \rm {M_\odot}$| is required to bend the Orphan stream, showing for the first time that the LMC has a large and measurable effect on structures orbiting the Milky Way. This has far-reaching consequences for any technique which assumes that tracers are orbiting a static Milky Way. Furthermore, we measure the Milky Way mass within 50 kpc to be |$3.80^{+0.14}_{-0.11}\times 10^{11} \, \mathrm{M}_\odot$|. Finally, we use these results to predict that, due to the reflex motion of the Milky Way in response to the LMC, the outskirts of the Milky Way’s stellar halo should exhibit a bulk, upwards motion.

79 ASTRONOMY AND ASTROPHYSICS↗

Integration of Real-Time Internal Electromagnetic Position Monitoring Coupled With Dynamic Multileaf Collimator Tracking: An Intensity-Modulated Radiation Therapy Feasibility Study

Purpose: Continuous tumor position measurement coupled with a tumor tracking system would result in a highly accurate radiation therapy system. Previous internal position monitoring systems have been limited by fluoroscopic radiation dose and low delivery efficiency. We aimed to incorporate a continuous, electromagnetic, three-dimensional position tracking system (Calypso 4D Localization System) with a dynamic multileaf collimator (DMLC)-based dose delivery system. Methods and Materials: A research version of the Calypso System provided real-time position of three Beacon transponders. These real-time three-dimensional positions were sent to research MLC controller with a motion-tracking algorithm that changed the planned leaf sequence. Electromagnetic transponders were embedded in a solid water film phantom that moved with patient lung trajectories while being irradiated with two different plans: a step-and-shoot intensity-modulated radiation therapy (S-IMRT) field and a dynamic IMRT (D-IMRT) field. Dosimetric results were recorded under three conditions: no intervention, DMLC tracking, and a spatial gating system. Results: Dosimetric accuracy was comparable for gating and DMLC tracking. Failure rates for gating/DMLC tracking are as follows: {+-}3 cGy 10.9/ 7.5% for S-IMRT, 3.3/7.2% for D-IMRT; gamma (3mm/3%) 0.2/1.2% for S-IMRT, 0.2/0.2% for D-IMRT. DMLC tracking proved to be as efficient as standard delivery, with a two- to fivefold efficiency increase over gating. Conclusions: Real-time target position information was successfully integrated into a DMLC effector system to modify dose delivery. Experimental results show both comparable dosimetric accuracy as well as improved efficiency compared with spatial gating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tracking blobs in the turbulent edge plasma of a tokamak fusion device

Abstract The analysis of turbulence in plasmas is fundamental in fusion research. Despite extensive progress in theoretical modeling in the past 15 years, we still lack a complete and consistent understanding of turbulence in magnetic confinement devices, such as tokamaks. Experimental studies are challenging due to the diverse processes that drive the high-speed dynamics of turbulent phenomena. This work presents a novel application of motion tracking to identify and track turbulent filaments in fusion plasmas, called blobs, in a high-frequency video obtained from Gas Puff Imaging diagnostics. We compare four baseline methods (RAFT, Mask R-CNN, GMA, and Flow Walk) trained on synthetic data and then test on synthetic and real-world data obtained from plasmas in the Tokamak à Configuration Variable (TCV). The blob regime identified from an analysis of blob trajectories agrees with state-of-the-art conditional averaging methods for each of the baseline methods employed, giving confidence in the accuracy of these techniques. By making a dataset and benchmark publicly available, we aim to lower the entry barrier to tokamak plasma research, thereby greatly broadening the community of scientists and engineers who might apply their talents to this endeavor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of dMLC for implementation of dynamic respiratory-gated radiation therapy

Purpose: To simulate and evaluate the use of dynamic multileaf collimators (dMLC) in respiratory gating to compensate for baseline drift.Methods: Tumor motion tracking data from 30 lung tumors over 322 treatment fractions was analyzed with the finite state model. A dynamic respiratory gating window was established in real-time by determining the average positions during the previous two end-of-expiration breathing phases and centering the dMLC aperture on a weighted average of these positions. A simulated dMLC with physical motion constraints was used in dynamic gating treatment simulations. Fluence maps were created to provide a statistical description of radiation delivery for each fraction. Duty cycle was also calculated for each fraction.Results: The average duty cycle was 2.3% greater under dynamic gating conditions. Dynamic gating also showed higher fluences and less tumor obstruction. Additionally, dynamic gating required fewer beam toggles and each delivery period was longer on average than with static gating.Conclusions: The use of dynamic gating showed better performance than static gating and the physical constraints of a dMLC were shown to not be an impediment to dynamic gating.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Failure Detection Strategy for Intrafraction Prostate Motion Monitoring With On-Board Imagers for Fixed-Gantry IMRT

Purpose: To develop methods to monitor prostate intrafraction motion during fixed-gantry intensity-modulated radiotherapy using MV treatment beam imaging together with minimal kV imaging for a failure detection strategy that ensures prompt detection when target displacement exceeds a preset threshold. Methods and Materials: Real-time two-dimensional (2D) marker position in the MV image plane was obtained by analyzing cine-MV images. The marker's in-line movement, and thus its time-varying three-dimensional (3D) position, was estimated by combining the 2D projection data with a previously established correlative relationship between the directional components of prostate motion. A confirmation request for more accurate localization using MV-kV triangulation was triggered when the estimated prostate displacement based on the cine-MV data was greater than 3 mm. An interventional action alert followed on positive MV-kV confirmation. To demonstrate the feasibility and accuracy of the proposed method, simulation studies of conventional-fraction intensity-modulated radiotherapy sessions were done using 536 Calypso-measured prostate trajectories from 17 radiotherapy patients. Results: A technique for intrafraction prostate motion management has been developed. The technique, using 'freely available' cine-MV images and minimum on-board kV imaging (on average 2.5 images/fraction), successfully limited 3D prostate movement to within a range of 3 mm relative to the MV beam for 99.4% of the total treatment time. On average, only approximately one intervention/fraction was needed to achieve this level of accuracy. Conclusion: Instead of seeking to accurately and continuously localize the prostate target as existing motion tracking systems do, the present technique effectively uses cine-MV data to provide a clinically valuable way to minimize kV usage, while maintaining high targeting accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A framework for the correction of slow physiological drifts during MR-guided HIFU therapies: Proof of concept

Purpose: While respiratory motion compensation for magnetic resonance (MR)-guided high intensity focused ultrasound (HIFU) interventions has been extensively studied, the influence of slow physiological motion due to, for example, peristaltic activity, has so far been largely neglected. During lengthy interventions, the magnitude of the latter can exceed acceptable therapeutic margins. The goal of the present study is to exploit the episodic workflow of these therapies to implement a motion correction strategy for slow varying drifts of the target area and organs at risk over the entire duration of the intervention. Methods: The therapeutic workflow of a MR-guided HIFU intervention is in practice often episodic: Bursts of energy delivery are interleaved with periods of inactivity, allowing the effects of the beam on healthy tissues to recede and/or during which the plan of the intervention is reoptimized. These periods usually last for at least several minutes. It is at this time scale that organ drifts due to slow physiological motion become significant. In order to capture these drifts, the authors propose the integration of 3D MR scans in the therapy workflow during the inactivity intervals. Displacements were estimated using an optical flow algorithm applied on the 3D acquired images. A preliminary study was conducted on ten healthy volunteers. For each volunteer, 3D MR images of the abdomen were acquired at regular intervals of 10 min over a total duration of 80 min. Motion analysis was restricted to the liver and kidneys. For validating the compatibility of the proposed motion correction strategy with the workflow of a MR-guided HIFU therapy, an in vivo experiment on a porcine liver was conducted. A volumetric HIFU ablation was completed over a time span of 2 h. A 3D image was acquired before the first sonication, as well as after each sonication. Results: Following the volunteer study, drifts larger than 8 mm for the liver and 5 mm for the kidneys prove that slow physiological motion can exceed acceptable therapeutic margins. In the animal experiment, motion tracking revealed an initial shift of up to 4 mm during the first 10 min and a subsequent continuous shift of ∼2 mm/h until the end of the intervention. This leads to a continuously increasing mismatch of the initial shot planning, the thermal dose measurements, and the true underlying anatomy. The estimated displacements allowed correcting the planned sonication cell cluster positions to the true target position, as well as the thermal dose estimates during the entire intervention and to correct the nonperfused volume measurement. A spatial coherence of all three is particularly important to assure a confluent ablation volume and to prevent remaining islets of viable malignant tissue. Conclusions: This study proposes a motion correction strategy for displacements resulting from slowly varying physiological motion that might occur during a MR-guided HIFU intervention. The authors have shown that such drifts can lead to a misalignment between interventional planning, energy delivery, and therapeutic validation. The presented volunteer study and in vivo experiment demonstrate both the relevance of the problem for HIFU therapies and the compatibility of the proposed motion compensation framework with the workflow of a HIFU intervention under clinical conditions.

60 APPLIED LIFE SCIENCES↗

Respiratory Amplitude Guided 4-Dimensional Magnetic Resonance Imaging

Purpose: To evaluate the feasibility of prospectively guiding 4-dimensional (4D) magnetic resonance imaging (MRI) image acquisition using triggers at preselected respiratory amplitudes to achieve T{sub 2} weighting for abdominal motion tracking. Methods and Materials: A respiratory amplitude-based triggering system was developed and integrated into a commercial turbo spin echo MRI sequence. Initial feasibility tests were performed on healthy human study participants. Four respiratory states, the middle and the end of inhalation and exhalation, were used to trigger 4D MRI image acquisition of the liver. To achieve T{sub 2} weighting, the echo time and repetition time were set to 75 milliseconds and 4108 milliseconds, respectively. Single-shot acquisition, together with parallel imaging and partial k-space imaging techniques, was used to improve image acquisition efficiency. 4D MRI image sets composed of axial or sagittal slices were acquired. Results: Respiratory data measured and logged by the MRI scanner showed that the triggers occurred at the appropriate respiratory levels. Liver motion could be easily observed on both 4D MRI image datasets by sensing either the change of liver in size and shape (axial) or diaphragm motion (sagittal). Both 4D MRI image datasets were T{sub 2}-weighted as expected. Conclusions: This study demonstrated the feasibility of achieving T{sub 2}-weighted 4D MRI images using amplitude-based respiratory triggers. With the aid of the respiratory amplitude-based triggering system, the proposed method is compatible with most MRI sequences and therefore has the potential to improve tumor-tissue contrast in abdominal tumor motion imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-213-04: Application of Depth Sensing and 3D-Printing Technique for Total Body Irradiation (TBI) Patient Measurement and Treatment Planning

Purpose: To develop and validate an innovative method of using depth sensing cameras and 3D printing techniques for Total Body Irradiation (TBI) treatment planning and compensator fabrication. Methods: A tablet with motion tracking cameras and integrated depth sensing was used to scan a RANDOTM phantom arranged in a TBI treatment booth to detect and store the 3D surface in a point cloud (PC) format. The accuracy of the detected surface was evaluated by comparison to extracted measurements from CT scan images. The thickness, source to surface distance and off-axis distance of the phantom at different body section was measured for TBI treatment planning. A 2D map containing a detailed compensator design was calculated to achieve uniform dose distribution throughout the phantom. The compensator was fabricated using a 3D printer, silicone molding and tungsten powder. In vivo dosimetry measurements were performed using optically stimulated luminescent detectors (OSLDs). Results: The whole scan of the anthropomorphic phantom took approximately 30 seconds. The mean error for thickness measurements at each section of phantom compare to CT was 0.44 ± 0.268 cm. These errors resulted in approximately 2% dose error calculation and 0.4 mm tungsten thickness deviation for the compensator design. The accuracy of 3D compensator printing was within 0.2 mm. In vivo measurements for an end-to-end test showed the overall dose difference was within 3%. Conclusion: Motion cameras and depth sensing techniques proved to be an accurate and efficient tool for TBI patient measurement and treatment planning. 3D printing technique improved the efficiency and accuracy of the compensator production and ensured a more accurate treatment delivery.

60 APPLIED LIFE SCIENCES↗

SU-E-J-168: Automated Pancreas Segmentation Based On Dynamic MRI

Purpose: MRI guided radiotherapy is particularly attractive for abdominal targets with low CT contrast. To fully utilize this modality for pancreas tracking, automated segmentation tools are needed. A hybrid gradient, region growth and shape constraint (hGReS) method to segment 2D upper abdominal dynamic MRI is developed for this purpose. Methods: 2D coronal dynamic MR images of 2 healthy volunteers were acquired with a frame rate of 5 f/second. The regions of interest (ROIs) included the liver, pancreas and stomach. The first frame was used as the source where the centers of the ROIs were annotated. These center locations were propagated to the next dynamic MRI frame. 4-neighborhood region transfer growth was performed from these initial seeds for rough segmentation. To improve the results, gradient, edge and shape constraints were applied to the ROIs before final refinement using morphological operations. Results from hGReS and 3 other automated segmentation methods using edge detection, region growth and level set were compared to manual contouring. Results: For the first patient, hGReS resulted in the organ segmentation accuracy as measure by the Dices index (0.77) for the pancreas. The accuracy was slightly superior to the level set method (0.72), and both are significantly more accurate than the edge detection (0.53) and region growth methods (0.42). For the second healthy volunteer, hGReS reliably segmented the pancreatic region, achieving a Dices index of 0.82, 0.92 and 0.93 for the pancreas, stomach and liver, respectively, comparing to manual segmentation. Motion trajectories derived from the hGReS, level set and manual segmentation methods showed high correlation to respiratory motion calculated using a lung blood vessel as the reference while the other two methods showed substantial motion tracking errors. hGReS was 10 times faster than level set. Conclusion: We have shown the feasibility of automated segmentation of the pancreas anatomy based on dynamic MRI.

60 APPLIED LIFE SCIENCES↗

Development of performance specifications for hybrid modeling of floating wind turbines in wave basin tests

Hybrid modeling—combining physical testing and numerical simulation in real time$-$opens new opportunities in floating wind turbine research. Wave basin testing is an important validation step for floating support structure design, but the conventional approaches that use physical wind above the basin are limited by scaling problems in the aerodynamics. Applying wind turbine loads with an actuation system that is controlled by a simulation responding to the basin test in real time offers a way to avoid scaling problems and reduce cost barriers for floating wind turbine design validation in realistic coupled wind and wave conditions. This paper demonstrates the development of performance specifications for a system that couples a wave basin experiment with a wind turbine simulation. Two different points for the hybrid coupling are considered: the tower-base interface and the aero-rotor interface (the boundary between aerodynamics and the rotor structure). Analyzing simulations of three floating wind turbine designs across seven load cases reveals the motion and force requirements of the coupling system. By simulating errors in the hybrid coupling system, the sensitivity of the floating wind turbine response to coupling quality can be quantified. The sensitivity results can then be used to determine tolerances for motion tracking errors, force actuation errors, bandwidth limitations, and latency in the hybrid coupling system. These tolerances can guide the design of hybrid coupling systems to achieve desired levels of accuracy. An example demonstrates how the developed methods can be used to generate performance specifications for a system at 1:50 scale. Results show that sensitivities vary significantly between support structure designs and that coupling at the aero-rotor interface has less stringent requirements than those for coupling at the tower base. As a result, the methods and results presented here can inform design of future hybrid coupling systems and enhance understanding of how test results are affected by hybrid coupling quality.

16 TIDAL AND WAVE POWER↗