Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Phase Diagrams of a Ferrimagnetic Superlattice in a Transverse Field: a Quantum Monte Carlo Simulation

In this work, quantum Monte Carlo simulation based on the Trotter-Suzuki formalism has been used to study the phase diagrams of a superlattice formed by two ferromagnetic slabs A and B with an antiferromagnetic interfacial coupling in a Transverse field. The effect of the transverse field Ω, the exchange coupling J{sub A}, and the thickness of the two slabs A and B on the phase diagrams of the system have been investigated. A number of interesting phenomena have been found. In particular, the superlattice can exhibit a compensation temperature T{sub k} or a compensation transverse field Ω{sub k} for certain ranges of the exchange interactions. The dependence of the critical and compensation behaviors on the slabs thicknesses has been also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SQERTSS: Dynamic rank based throttling of transition probabilities in kinetic Monte Carlo simulations

Lattice based Kinetic Monte Carlo (KMC) simulations offer a powerful simulation technique for investigating large reaction networks while retaining spatial configuration information, unlike ordinary differential equations. However, large chemical reaction networks can contain reaction processes with rates spanning multiple orders of magnitude. This can lead to the problem of “KMC stiffness” (similar to stiffness in differential equations), where the computational expense has the potential to be overwhelmed by very short time-steps during KMC simulations, with the simulation spending an inordinate amount of KMC steps / cpu-time simulating fast frivolous processes (FFPs) without progressing the system (reaction network). In order to achieve simulation times that are experimentally relevant or desired for predictions, a dynamic throttling algorithm involving separation of the processes into speed-ranks based on event frequencies has been designed and implemented with the intent of decreasing the probability of FFP events, and increasing the probability of slow process events -- allowing rate limiting events to become more likely to be observed in KMC simulations. This Staggered Quasi-Equilibrium Rank-based Throttling for Steady-state (SQERTSS) algorithm designed for use in achieving and simulating steady-state conditions in KMC simulations. Lastly, as shown in this work, the SQERTSS algorithm also works for transient conditions: the correct configuration space and final state will still be achieved if the required assumptions are not violated, with the caveat that the sizes of the time-steps may be distorted during the transient period.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulations of Deep Galaxy Fields I: Monte-Carlo Simulations of Optical and Near Infrared Counts

Monte-Carlo simulations of three dimensional galaxy distributions are performed, following the prescription of Chokishi & Wright (1988), to study the photometric properties of evolving galaxy populations in the optical and near infrared bands to high redshifts. Galaxies are spatially distributed according to the spatial two point correlation function in a range of cluster to field environments andin volume elements appropriate to the cosmological model under consideration. Details of individual galaxy properties, including luminosities, morphologies, disk-to-bulge ratios, and size distributions are simulated to match local observed galaxy properties. Galaxies have evolving gas fraction, metallicity and spectral energy distributions that include both stellar emission and internal dust absorption and re-emission. The simulations result in noiseless two dimensional galaxy distributions on the sky that canbe compared to the observed deep images in the blue and near-infrared bands...

faint↗

Direct simulation Monte Carlo and Navier-Stokes simulations of blunt body wake flows

Numerical results obtained with direct simulation Monte Carlo and Navier-Stokes methods are presented for a Mach-20 nitrogen flow about a 70-deg blunted cone. The flow conditions simuulated are those that can be obtained in existing low-density hypersonic wind tunnels. Three sets of flow conditions are considered with freestream Knudsen numbers ranging from 0.03 to 0.001. The focus is on the wake structure: how the wake structure changes as a function of rarefaction, what the afterbody levels of heating are, and to what limits the continuum models are realistic as rarefaction in the wake is progressively increased. Calculations are made with and without an afterbody sting. Results for the after body sting are emphasizes in anticipation of an experimental study for the current flow conditions and model configuration. The Navier-Stokes calculations were made with and without slip boundary conditions. Comparisons of the results obtained with the two simulation methodologies are made for both flowfield structure and surface quantities.

Moss, James N.↗

Characterization of scatter in digital mammography from use of Monte Carlo simulations and comparison to physical measurements

Purpose: Monte Carlo simulations were performed with the goal of verifying previously published physical measurements characterizing scatter as a function of apparent thickness. A secondary goal was to provide a way of determining what effect tissue glandularity might have on the scatter characteristics of breast tissue. The overall reason for characterizing mammography scatter in this research is the application of these data to an image processing-based scatter-correction program. Methods: MCNPX was used to simulate scatter from an infinitesimal pencil beam using typical mammography geometries and techniques. The spreading of the pencil beam was characterized by two parameters: mean radial extent (MRE) and scatter fraction (SF). The SF and MRE were found as functions of target, filter, tube potential, phantom thickness, and the presence or absence of a grid. The SF was determined by separating scatter and primary by the angle of incidence on the detector, then finding the ratio of the measured scatter to the total number of detected events. The accuracy of the MRE was determined by placing ring-shaped tallies around the impulse and fitting those data to the point-spread function (PSF) equation using the value for MRE derived from the physical measurements. The goodness-of-fit was determined for each data set as a means of assessing the accuracy of the physical MRE data. The effect of breast glandularity on the SF, MRE, and apparent tissue thickness was also considered for a limited number of techniques. Results: The agreement between the physical measurements and the results of the Monte Carlo simulations was assessed. With a grid, the SFs ranged from 0.065 to 0.089, with absolute differences between the measured and simulated SFs averaging 0.02. Without a grid, the range was 0.28–0.51, with absolute differences averaging −0.01. The goodness-of-fit values comparing the Monte Carlo data to the PSF from the physical measurements ranged from 0.96 to 1.00 with a grid and 0.65 to 0.86 without a grid. Analysis of the data suggested that the nongrid data could be better described by a biexponential function than the single exponential used here. The simulations assessing the effect of breast composition on SF and MRE showed only a slight impact on these quantities. When compared to a mix of 50% glandular/50% adipose tissue, the impact of substituting adipose or glandular breast compositions on the apparent thickness of the tissue was about 5%. Conclusions: The findings show agreement between the physical measurements published previously and the Monte Carlo simulations presented here; the resulting data can therefore be used more confidently for an application such as image processing-based scatter correction. The findings also suggest that breast composition does not have a major impact on the scatter characteristics of breast tissue. Application of the scatter data to the development of a scatter-correction software program can be simplified by ignoring the variations in density among breast tissues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Venus resurfacing rates: Constraints provided by 3-D Monte Carlo simulations

A 3-D Monte Carlo model that simulates the evolving surface of Venus under the influence of a flux of impacting objects and a variety of styles of volcanic resurfacing was implemented. For given rates of impact events and resurfacing, the model predicts the size-frequency and areal distributions of surviving impact craters as a function of time. The number of craters partially modified by volcanic events is also calculated as the surface evolves. It was found that a constant, global resurfacing rate of approximately 0.4 km(sup 3)/yr is required to explain the observed distributions of both the entire crater population, and the population of craters partially modified by volcanic processes.

Bullock, M. A.↗

Direct simulation Monte Carlo study of effects of thermal nonuniformities in electron-beam physical vapor deposition

In a typical electron-beam physical vapor deposition system, there is limited control over how the high-power electron beam heats the metal surface. This leads to thermal nonuniformities at the melt. Three-dimensional direct simulation Monte Carlo simulations were performed with the aim of quantifying the effect of such spatial variations of source temperature in thin film depositions using an electron-beam physical vapor deposition system. The source temperature distribution from a typical deposition process was used in the direct simulation Monte Carlo simulations performed for various mass flow rates. The use of an area-averaged temperature is insufficient for all mass flow rates due to the highly nonlinear relationship between temperature and saturation number density, and hence, the mass flux. The mass flow rate equivalent temperature was determined, and the simulations performed with this temperature were compared with those corresponding to the actual nonuniform temperature distribution. For low mass flow rates, the growth rates depend very weakly on the spatial variation of temperature as long as an equivalent temperature corresponding to the same mass flow rate was used. However, as the mass flow rate increases, the error associated with this approximation increases. For deposition processes with source Knudsen numbers less than 0.05, it is not possible to account for the spatial nonuniformities in temperature using the total mass flow rate without significant errors. For a given mass flow rate, the errors associated with using an equivalent temperature decrease with increasing collector plane distance since the flow is allowed to expand further, thereby decreasing the effects of slit temperature nonuniformities.

36 MATERIALS SCIENCE↗

Monte Carlo simulation of the Neutrino-4 experiment

Monte Carlo simulation of the two-section reactor antineutrino detector of the Neutrino-4 experiment is carried out. The scintillation-type detector is based on the inverse beta-decay reaction. The antineutrino is recorded by two successive signals from the positron and the neutron. The simulation of the detector sections and the active shielding is performed. As a result of the simulation, the distributions of photomultiplier signals from the positron and the neutron are obtained. The efficiency of the detector depending on the signal recording thresholds is calculated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data Science Shows that Entropy Correlates with Accelerated Zeolite Crystallization in Monte Carlo Simulations

We have performed a data science study of Monte Carlo simulation trajectories to understand factors that can accelerate formation of zeolite nanoporous crystals, a process that can take days or even weeks. In previous work, Monte Carlo simulations predicted and experiments confirmed that using a secondary organic structure-directing agent (OSDA) accelerates crystallization of all-silica LTA zeolite, with experiments finding a three-fold speedup [PCCP 24, 142-148 (2022)]. However, it remains unclear what physical factors cause the speed-up. Here, we apply data science to analyze the simulation trajectories to discover what drives accelerated zeolite crystallization in Monte Carlo going from a one-OSDA synthesis (1OSDA) to a two-OSDA version (2OSDA). We encoded simulation snapshots using the Smooth Overlap of Atomic Positions approach, which represents all 2- and 3-body correlations within a given cutoff distance. Principal component analyses failed to discriminate datasets of structures from 1OSDA and 2OSDA simulations, while the Support Vector Machine (SVM) approach succeeded at classifying such structures with an area-under-curve (AUC) score of 0.99 (where AUC = 1 is a perfect classification) with all 3-body correlations, and as high as 0.94 with only 2-body correlations. SVM decision functions reveal relatively broad / narrow histograms for 1OSDA / 2OSDA datasets, suggesting that the two simulations differ strongly in information heterogeneity. Informed by these results, we performed pair (2-body) entropy calculations during crystallization, resulting in entropy differences that semi-quantitatively account for the speedup observed in the previous Monte Carlo simulations. We conclude that altering synthesis conditions in ways that substantially changes the entropy of labile silica networks may accelerate zeolite crystallization, and we discuss possible approaches for achieving such acceleration.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Comparison of internal dose estimates obtained using organ-level, voxel S value, and Monte Carlo techniques

Purpose: The authors’ objective was to compare internal dose estimates obtained using the Organ Level Dose Assessment with Exponential Modeling (OLINDA/EXM) software, the voxel S value technique, and Monte Carlo simulation. Monte Carlo dose estimates were used as the reference standard to assess the impact of patient-specific anatomy on the final dose estimate. Methods: Six patients injected with{sup 99m}Tc-hydrazinonicotinamide-Tyr{sup 3}-octreotide were included in this study. A hybrid planar/SPECT imaging protocol was used to estimate {sup 99m}Tc time-integrated activity coefficients (TIACs) for kidneys, liver, spleen, and tumors. Additionally, TIACs were predicted for {sup 131}I, {sup 177}Lu, and {sup 90}Y assuming the same biological half-lives as the {sup 99m}Tc labeled tracer. The TIACs were used as input for OLINDA/EXM for organ-level dose calculation and voxel level dosimetry was performed using the voxel S value method and Monte Carlo simulation. Dose estimates for {sup 99m}Tc, {sup 131}I, {sup 177}Lu, and {sup 90}Y distributions were evaluated by comparing (i) organ-level S values corresponding to each method, (ii) total tumor and organ doses, (iii) differences in right and left kidney doses, and (iv) voxelized dose distributions calculated by Monte Carlo and the voxel S value technique. Results: The S values for all investigated radionuclides used by OLINDA/EXM and the corresponding patient-specific S values calculated by Monte Carlo agreed within 2.3% on average for self-irradiation, and differed by as much as 105% for cross-organ irradiation. Total organ doses calculated by OLINDA/EXM and the voxel S value technique agreed with Monte Carlo results within approximately ±7%. Differences between right and left kidney doses determined by Monte Carlo were as high as 73%. Comparison of the Monte Carlo and voxel S value dose distributions showed that each method produced similar dose volume histograms with a minimum dose covering 90% of the volume (D90) agreeing within ±3%, on average. Conclusions: Several aspects of OLINDA/EXM dose calculation were compared with patient-specific dose estimates obtained using Monte Carlo. Differences in patient anatomy led to large differences in cross-organ doses. However, total organ doses were still in good agreement since most of the deposited dose is due to self-irradiation. Comparison of voxelized doses calculated by Monte Carlo and the voxel S value technique showed that the 3D dose distributions produced by the respective methods are nearly identical.

60 APPLIED LIFE SCIENCES↗

Technical Note: Study of the electron transport parameters used in PENELOPE for the Monte Carlo simulation of Linac targets

Purpose: The Monte Carlo simulation of electron transport in Linac targets using the condensed history technique is known to be problematic owing to a potential dependence of absorbed dose distributions on the electron step length. In the PENELOPE code, the step length is partially determined by the transport parameters C1 and C2. The authors have investigated the effect on the absorbed dose distribution of the values given to these parameters in the target. Methods: A monoenergetic 6.26 MeV electron pencil beam from a point source was simulated impinging normally on a cylindrical tungsten target. Electrons leaving the tungsten were discarded. Radial absorbed dose profiles were obtained at 1.5 cm of depth in a water phantom located at 100 cm for values of C1 and C2 in the target both equal to 0.1, 0.01, or 0.001. A detailed simulation case was also considered and taken as the reference. Additionally, lateral dose profiles were estimated and compared with experimental measurements for a 6 MV photon beam of a Varian Clinac 2100 for the cases of C1 and C2 both set to 0.1 or 0.001 in the target. Results: On the central axis, the dose obtained for the case C1 = C2 = 0.1 shows a deviation of (17.2% ± 1.2%) with respect to the detailed simulation. This difference decreases to (3.7% ± 1.2%) for the case C1 = C2 = 0.01. The case C1 = C2 = 0.001 produces a radial dose profile that is equivalent to that of the detailed simulation within the reached statistical uncertainty of 1%. The effect is also appreciable in the crossline dose profiles estimated for the realistic geometry of the Linac. In another simulation, it was shown that the error made by choosing inappropriate transport parameters can be masked by tuning the energy and focal spot size of the initial beam. Conclusions: The use of large path lengths for the condensed simulation of electrons in a Linac target with PENELOPE conducts to deviations of the dose in the patient or phantom. Based on the results obtained in this work, values of C1 and C2 larger than 0.001 should not be used in Linac targets without further investigation.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-146: Comparing Monte Carlo Simulations with Commissioning Beam Data for Mevion S250 Proton Therapy System

Purpose: To evaluate the Monte Carlo simulated beam data with the measured commissioning data for the Mevion S250 proton therapy system. Method: The Mevion S250 proton therapy system utilizes a passive double scattering technique with a unique gantry mounted superconducting accelerator and offers effective proton therapy in a compact design concept. The field shaping system (FSS) includes first scattering foil, range modulator wheel (RMW), second scattering foil and post absorber and offers two field sizes and a total of 24 treatment options from proton range of 5 cm to 32 cm. The treatment nozzle was modeled in detail using TOPAS (TOolkit for PArticle Simulation) Monte Carlo code. The timing feathers of the moving modulator wheels were also implemented to generate the Spread Out Bragg Peak (SOBP). The simulation results including pristine Bragg Peak, SOBP and dose profiles were compared with the data measured during beam commissioning. Results: The comparison between the measured data and the simulation data show excellent agreement. For pristine proton Bragg Peaks, the simulated proton range (depth of distal 90%) values agreed well with the measured range values within 1 mm accuracy. The differences of the distal falloffs (depth from distal 80% to 20%) were also found to be less than 1 mm between the simulations and measurements. For the SOBP, the widths of modulation (depth of proximal 95% to distal 90%) were also found to agree with the measurement within 1 mm. The flatness of the simulated and measured lateral profiles was found to be 0.6 % and 1.1 %, respectively. Conclusion: The agreement between simulations and measurements demonstrate that TOPAS could be used as a viable platform to proton therapy applications. The matched simulation results offer a great tool and open opportunity for variety of applications.

60 APPLIED LIFE SCIENCES↗

A practical approach to the sensitivity analysis for kinetic Monte Carlo simulation of heterogeneous catalysis

Lattice kinetic Monte Carlo simulations have become a vital tool for predictive quality atomistic understanding of complex surface chemical reaction kinetics over a wide range of reaction conditions. In order to expand their practical value in terms of giving guidelines for atomic level design of catalytic systems, it is very desirable to readily evaluate a sensitivity analysis for a given model. The result of such a sensitivity analysis quantitatively expresses the dependency of the turnover frequency, being the main output variable, on the rate constants entering the model. In the past the application of sensitivity analysis, such as Degree of Rate Control, has been hampered by its exuberant computational effort required to accurately sample numerical derivatives of a property that is obtained from a stochastic simulation method. Here in this study we present an efficient and robust three stage approach that is capable of reliably evaluating the sensitivity measures for stiff microkinetic models as we demonstrate using CO oxidation on RuO 2 (110) as a prototypical reaction. In a first step, we utilize the Fisher Information Matrix for filtering out elementary processes which only yield negligible sensitivity. Then we employ an estimator based on linear response theory for calculating the sensitivity measure for non-critical conditions which covers the majority of cases. Finally we adopt a method for sampling coupled finite differences for evaluating the sensitivity measure of lattice based models. This allows efficient evaluation even in critical regions near a second order phase transition that are hitherto difficult to control. The combined approach leads to significant computational savings over straightforward numerical derivatives and should aid in accelerating the nano scale design of heterogeneous catalysts.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monte Carlo Simulation of Sudden Death Bearing Testing

Monte Carlo simulations combined with sudden death testing were used to compare resultant bearing lives to the calculated hearing life and the cumulative test time and calendar time relative to sequential and censored sequential testing. A total of 30 960 virtual 50-mm bore deep-groove ball bearings were evaluated in 33 different sudden death test configurations comprising 36, 72, and 144 bearings each. Variations in both life and Weibull slope were a function of the number of bearings failed independent of the test method used and not the total number of bearings tested. Variation in L10 life as a function of number of bearings failed were similar to variations in lift obtained from sequentially failed real bearings and from Monte Carlo (virtual) testing of entire populations. Reductions up to 40 percent in bearing test time and calendar time can be achieved by testing to failure or the L(sub 50) life and terminating all testing when the last of the predetermined bearing failures has occurred. Sudden death testing is not a more efficient method to reduce bearing test time or calendar time when compared to censored sequential testing.

Vlcek, Brian L.↗

Electrolyte clusters as hydrogen sponges: diffusion Monte Carlo simulations

Here, we carry out Diffusion Monte Carlo simulations of up to five hydrogen molecules aggregated with two Stockmayer clusters that solvate a single lithium ion. The first one contains six point dipole solvent particles with parameters tuned to emulate nitromethane. The second cluster is a relative large system investigated recently [G. DiEmma, S. Kalette, and E. Curotto, Chem. Phys. Lett. 2019, 725, 80–86]. In both cases we find that the aggregated hydrogen molecules perturb significantly the ground state of the host cluster and form a distorted tetrahedral cage around the Li + ion. The fifth hydrogen molecule is absorbed by the larger Stockmayer cluster while remaining in the proximity of the solvated charge.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monte Carlo simulation of vibrational relaxation in nitrogen

Monte Carlo simulation of nonequilibrium vibrational relaxation of (rotationless) N2 using transition probabilities form an extended SSH theory is presented. For the range of temperatures considered, 4000-8000 K, the vibrational levels were found to be reasonably close to an equilibrium distribution at an average vibrational temperature based on the vibrational energy of the gas. As a result, they do not show any statistically significant evidence of the bottleneck observed in earlier studies of N2. Based on this finding, it appears that, for the temperature range considered, dissociation commences after all vibrational levels equilibrate at the translational temperature.

Olynick, David P.↗

Effects of surface diffusion in electrocatalytic CO 2 reduction on Cu revealed by kinetic Monte Carlo simulations

We report Kinetic Monte Carlo (KMC) methods are frequently used for mechanistic studies of thermally driven heterogeneous catalysis systems but are underused for electrocatalysis. Here, we develop a lattice KMC approach for electrocatalytic CO 2 reduction. The work is motivated by a prior experimental report that performed electroreduction of a mixed feed of 12 CO 2 and 13 CO on Cu; differences in the 13 C content of C2 products ethylene and ethanol (Δ 13 C) were interpreted as evidence of site selectivity. The lattice KMC model considers the effect of surface diffusion on this system. In the limit of infinitely fast diffusion (mean-field approximation), the key intermediates 12 CO* and 13 CO* would be well mixed on the surface and no evidence of site selectivity could have been observed. Using a simple two-site model and adapting a previously reported microkinetic model, we assess the effects of diffusion on the relative isotope fractions in the products using the estimated surface diffusion rate of CO* from literature reports. We find that the size of the active sites and the total surface adsorbate coverage can have a large influence on the values of Δ 13 C that can be observed. Δ 13 C is less sensitive to the CO* diffusion rate as long as it is within the estimated range. We further offer possible methods to estimate surface distribution of intermediates and to predict intrinsic selectivity of active sites based on experimental observations. This work illustrates the importance of considering surface diffusion in the study of electrochemical CO 2 reduction to multi-carbon products. Our approach is entirely based on a freely available open-source code, so will be readily adaptable to other electrocatalytic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗